• Title/Summary/Keyword: pressure capsule

Search Result 56, Processing Time 0.044 seconds

Influence of the Mars atmosphere model on aerodynamics of an entry capsule: Part II

  • Zuppardi, Gennaro
    • Advances in aircraft and spacecraft science
    • /
    • v.7 no.3
    • /
    • pp.229-249
    • /
    • 2020
  • This paper is the logical follow-up of four papers by the author on the subject "aerodynamics in Mars atmosphere". The aim of the papers was to evaluate the influence of two Mars atmosphere models (NASA Glenn and GRAM-2001) on aerodynamics of a capsule (Pathfinder) entering the Mars atmosphere and also to verify the feasibility of evaluating experimentally the ambient density and the ambient pressure by means of the methods by McLaughlin and Cassanto respectively, therefore to correct the values provided by the models. The study was carried out computationally by means of: i) a code integrating the equations of dynamics of an entry capsule for the computation of the trajectories, ii) two Direct Simulation Monte Carlo (DSMC) codes for the solution of the 2-D, axial-symmetric and 3-D flow fields around the capsule in the altitude interval 50-100 km. The computations verified that the entry trajectories of Pathfinder from the two models, in terms of the Mach, Reynolds and Knudsen numbers, were very different. The aim of the present paper is to continue this study, considering other aerodynamic problems and then to provide a contribution to a long series of papers on the subject "aerodynamics in Mars atmosphere". More specifically, the present paper evaluated and quantified the effects from the two models of: i) chemical reactions on aerodynamic quantities in the shock layer, ii) surface temperature, therefore of the contribution of the re-emitted molecules, on local (pressure, skin friction, etc.) and on global (drag) quantities, iii) surface recombination reactions (catalyticity) on heat flux. The results verified that the models heavily influence the flow field (as per the shock wave structure) but, apart from the surface recombination reactions, the effects of the different conditions on aerodynamics of the capsule are negligible for both models and confirmed what already found in the previous paper that, because of the higher values of density from the NASA Glenn model, the effects on aerodynamics of a entry capsule are stronger than those computed by the GRAM-2001 model.

Effect of geometrical parameters of reentry capsule over flowfield at high speed flow

  • Mehta, R.C.
    • Advances in aircraft and spacecraft science
    • /
    • v.4 no.4
    • /
    • pp.487-501
    • /
    • 2017
  • The main purpose of the paper is to analyze effect of geometrical parameters of the reentry capsules such as radius of the spherical cap, shoulder radius, back shell inclination angle and overall length on the flow field characteristics. The numerical simulation with viscous flow past ARD (Atmospheric Reentry Demonstrator), Soyuz (Russian) and OREX (Orbital Reentry EXperimental) reentry capsules for freestream Mach numbers range of 2.0-5.0 is carried out by solving time-dependent, axisymmetric, compressible laminar Navier-Stokes equations. These reentry capsules appear as bell, head light and saucer in shape. The flow field features around the reentry capsules such as bow shock wave, sonic line, expansion fan and recirculating flow region are well captured by the present numerical simulations. A low pressure is observed immediately downstream of the base region of the capsule which can be attributed to fill-up in the growing space between the shock wave and the reentry module. The back shell angle and the radius of the shoulder over the capsule are having a significant effect on the wall pressure distribution. The effects of geometrical parameters of the reentry capsules will useful input for the calculation of ballistic coefficient of the reentry module.

Development of an Irradiation Device for High Temperature Materials in HANARO (하나로에서의 고온재료 조사장치 개발)

  • Cho, Man Soon;Choo, Kee Nam
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.2
    • /
    • pp.145-153
    • /
    • 2011
  • The irradiation tests of materials in HANARO have been performed usually at temperatures below $300^{\circ}C$ at which the RPV(Reactor Pressure Vessel) materials of the commercial reactors such as the light water reactor and CANDU are operated. As VHTR(Very High Temperature Reactor) and SFR(Sodium-cooled Fast Reactor) projects are being carried as a part of the present Gen-IV program in Korea, the requirements for irradiation of materials at temperatures higher than $500^{\circ}C$ are recently being gradually increased. To overcome the restriction in the use at high temperature of the existing Al thermal media, a new capsule with double thermal media composed of two kinds of materials such as Al-Ti and Al-graphite was designed and fabricated more advanced than the single thermal media capsule. At the irradiation test of the capsule, the temperature of the specimens successfully reached $700^{\circ}C$ and the integrity of Al, Ti and graphite material was maintained.

Pressure Monitoring System in Gastro-Intestinal Tract

  • Kim, Byung-Kyu;Kim, Yong-In;Park, Suk-Ho;Jo, Jin-Ho;Park, Gwi-Tae
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.196-201
    • /
    • 2005
  • Diseases in the gastro-intestinal tract are on an increasing trend. In order to diagnose a patient, various signals of the digestive organ, such as temperature, pH, and pressure, can offer the helpful information. Among the above mentioned signals, we choose the pressure variation as a monitoring signal. The variation of a pressure signal of the gastro-intestinal tract can offer the information of a digestive trouble or some clues of the diseases. In this paper, a pressure monitoring system for the digestive organs of a living pig is presented. This is why a pig's gastro-intestinal tract is very similar as human's. This system concept is to transmit the measured biomedical signals from a transmitter in a living pig to a wireless receiver that is positioned out of body. The integrated solution includes the swallow type pressure capsule and the receiving set consisting of a receiver, decoder circuit. The merit of the proposed system is that the monitoring system can supply the precise and a durable characteristic to measure and to transmit a signal in the gastro-intestinal tract. We achieved the pressure tracings in digestive organs and verified the validity of system after several in-vivo tests using the pressure monitoring system. Through various experiments, we found each organ has its own characterized pressure fluctuation.

  • PDF

Performance Tests and Development of the Cyclic Load Device Using a Bellows (벨로우즈를 이용한 반복 하중부과장치의 개발 및 성능시험)

  • Choi, Myoung-Hwan;Cho, Man-Soon;Park, Sung-Jae;Kim, Bong-Goo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.9
    • /
    • pp.903-909
    • /
    • 2007
  • A fatigue capsule is one of the special capsules to investigate the fatigue characteristics of the nuclear materials during an irradiation test in a research reactor, HANARO. In this study, the performance test and the preliminary fatigue test results by using a cyclic load device newly developed for a fatigue capsule are described. In order to obtain the characteristics such as a realization and a controllability of the periodic wave shape and the relationship between the pressure and the load, a spring and rigid bar specimens are used. The fatigue test for the 316L stainless steel specimen with 1.8mm in diameter and 12.5mm in gage length is also performed under the same conditions as the temperature($550^{\circ}C$) of the specimen during irradiation tests. As a result of the test, the fracture of the specimen occurs at a total of 70,120 cycles(about 12 days), and the displacement in this case is 2.02 mm. It is expected that these results will be used for determining test conditions and a comparison of the in-pile fatigue test results.

(A) Study on Natural Dyeing of polyester(I) - Ginseng Microcapsules - (폴리에스테르의 천연염색 처리 방법에 관한 연구(I) - 인삼 마이크로캡슐을 중심으로 -)

  • Min, Kyung-Hae
    • Fashion & Textile Research Journal
    • /
    • v.10 no.4
    • /
    • pp.560-565
    • /
    • 2008
  • Plantae of the natural material has been broadly used on cloth dyeing by it's specific properties such as eco-friendly and innoxious. However dyeing with natural material on synthetic fiber is nearly impossible due to poor affinity between natural material and synthetic fiber. The method which is binding with micro-capsulized natural material to cloth, used in this study, has low change on quality by external influence. Also this method has high ability in spray effect by broken capsule which comes to pressure and friction when the treated cloth was dressed. And this method is applicable widely from natural fiber to synthetic fiber. The purpose of this study is to develop the multi-functional synthetic material with micro-capsulized Ginseng on PET. Moreover, it was driven by comparison of colormetric properties and fastness between regular dip-dyeing method and binding with micro-capsulized material method. Dyeability showed a little bit low exhaustion but the PET treated by micro-capsule was more or less better than the dip dyed PET. Through the SEM(Scanning Electron Microscope) of PET treated by micro-capsule, it has good residence of capsules even after 5 or 10 times washing. Wash and light fastness were revealed some different grades by each condition but showed high level, in most and the micro-capsulized PET was more improver than regular dip dyed PET.

Natural Dyeing of Polyester Fabric with Microcapsules(II) - Scutellaria baicalensis - (마이크로캡슐에 의한 폴리에스테르 직물의 천연염색에 관한 연구(II) - 황금을 중심으로 -)

  • Min, Kyung-Hae
    • Fashion & Textile Research Journal
    • /
    • v.10 no.6
    • /
    • pp.1045-1050
    • /
    • 2008
  • Developing of high technology, productivity of the fiber product has being rapidly increased and also various kinds of advanced treatment process lead consumer's needs to more high functional, clean and healthy goods. Moreover, increasing in the concern of eco-friendly material and processing, it has been getting popular that the dyeing method like as using natural dyes is more eco-friendly and natural-friendly treatment process. The method, used in this study, adhesion by binding with micro-capsulized natural material to fabric has low change in quality by external influence and high ability in spray effect by broken capsule which comes to pressure and friction when it dressed. Also it has wide application from natural fiber to synthetic fiber. The purpose of this study is development of multi-functional synthetic material with micro-capsulized Scutellaria baicalensis on PET. Moreover, it was driven by comparison of colormetric properties and fastness between regular dip-dyeing method and binding with micro-capsulized material method. Dye ability was arranged mostly low exhaustion but the PET treated by micro-capsule was more or less better than the dip-dyeing PET. Through the SEM(Scanning Electron Microscope) of PET treated by micro-capsule, it has good residence of capsules even after 5 or 10 times washing. Wash and light fastness was arranged some different grade by each condition but mostly high achievement and the micro-capsulized PET was more improved than regular dip-dyed PET.