• Title/Summary/Keyword: predictive power control

Search Result 281, Processing Time 0.029 seconds

Development of predictive model for pollutants emission from the power plant in a steel plant (제철소내 발전소에서의 대기오염 물질 배출 패턴 모델링)

  • 김민석;이창형;양대륙;장근수
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1993.10a
    • /
    • pp.601-606
    • /
    • 1993
  • From the power plants in a steel plant, environment pollutants such as SOx, NOx, CO are emitted by the combustion reaction between the fuels those are by-product gases and oil. To reduce the amounts of the pollutants, it must be important that build the predictive models for the emission of the pollutants. In this paper, the model that predict the amount of future fuel consumption and the model that predict the amount of generated pollutants for the used fuel amounts is developed by using Gibb's free energy minimization method with the temperature correction techniques and neural network back propagation method. For some data set, the calculation results from this models are compared with the real emission amounts of SOx, NOx and result of the calculation by the ASPEN plus which is a commercial software. The result from this model is better than the result by ASPEN plus for this problem.

  • PDF

Single Sensor Current Control of a Three-Phase Voltage-Source PWM Converter Using Predictive State Observer (예측 상태 관측기를 이용한 3상 전압 원 PWM 컨버터의 단일 센서 전류 제어)

  • 이우철;현동석
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.3
    • /
    • pp.249-256
    • /
    • 1999
  • 본 논문에서는 DC link단에 단일 전류 센서를 사용한 3상 전압 원 PWM 컨버터의 제어방법에 대해서 제안하고, DC link 전류로부터 3상 전류를 재 구축하는 PWM 변조 전략을 제시한다. 단일 전류 센서를 사용하여 3상 전류를 재 구축시 문제점은 2개의 유효 벡터중 1개 또는 2개의 유효벡터가 아주 짧은 시간 동안 인가 되었을 때로 이 경우에는 3상 전류를 적절히 재 구축할 수 없게 된다. 이런 경우에는 예측 전류 제어기를 사용하여 모든 동작 조건에서 믿을만한 3상 전류를 재 구축한다. 또한 디지털 제어로 인한 지연에 대한 보상도 제시된다. 본 논문에서는 3상 PWM 컨버터 제어시 예측 상태 관측기를 사용한 단일 센서 전류 제어가 논의되며 실험 결과로 입증된다.

  • PDF

Control of Three-Phase PWM Rectifiers Using Only DC-Side Sensors (직류측 센서만을 이용한 3상 PWM 정류기의 제어)

  • 이동춘
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.278-281
    • /
    • 2000
  • In this abstract a novel control scheme of voltage-source PWM rectifiers using only dc-side sensors is proposed. The phase currents are reconstructed from switching states of the rectifier and the dc output current. For effective current control the currents are estimated by a predictive state observer. Also both the phase angle and the magnitude of th source voltage are estimated by phase estimator and magnitude estimator respectively. The validity of the proposed ac sensorless technique is verified by experimental results.

  • PDF

Low Parameter Sensitivity Deadbeat Direct Torque Control for Surface Mounted Permanent Magnet Synchronous Motors

  • Zhang, Xiao-Guang;Wang, Ke-Qin;Hou, Ben-Shuai
    • Journal of Power Electronics
    • /
    • v.17 no.5
    • /
    • pp.1211-1222
    • /
    • 2017
  • In order to decrease the parameter sensitivity of deadbeat direct torque control (DB-DTC), an improved deadbeat direct torque control method for surface mounted permanent-magnet synchronous motor (SPMSM) drives is proposed. First, the track errors of the stator flux and torque that are caused by model parameter mismatch are analyzed. Then a sliding mode observer is designed, which is able to predict the d-q axis currents of the next control period for one-step delay compensation, and to simultaneously estimate the model parameter disturbance. The estimated disturbance of this observer is used to estimate the stator resistance offline. Then the estimated resistance is required to update the designed sliding-mode observer, which can be used to estimate the inductance and permanent-magnetic flux linkage online. In addition, the flux and torque estimation of the next control period, which is unaffected by the model parameter disturbance, is achieved by using predictive d-q axis currents and estimated parameters. Hence, a low parameter sensitivity DB-DTC method is developed. Simulation and experimental results show the validity of the proposed direct control method.

A Study on the Fault-Tolerant and Bumpless Switching Control for Boiler Systems in the Power Plant (발전용 보일러 시스템의 이상허용 및 과도상태의 유연한 제어에 관한 연구)

  • Kwon, Oh-Kyu;Lee, Young-Sam
    • Proceedings of the KIEE Conference
    • /
    • 1998.11c
    • /
    • pp.1037-1040
    • /
    • 1998
  • In this research a fault-tolerant and bumpless switching control is proposed for boiler systems used in the power plants. Firstly, three operating points are selected to control the nonlinear boiler through the full operational range, and the $H_{\infty}$ loop shaping controller and the model-based predictive controller(MBPC) are designed. To prevent the windup and bump problems which are caused by the actuator saturation and the controller switching, an anti-windup and bumpless transfer technique is adopted to the $H_{\infty}$ loop shaping controller. Also the constrained gain-scheduling technique is applied to MBPC to achieve the same objective. Secondly, the fault-tolerant control technique is proposed to continue the control action without stopping the boiler operation even in case of some faults. Through various simulation studies, the performances of the proposed control techniques are demonstrated.

  • PDF

A Study on the Fault-Tolerant and Bumpless Switching Control for Boiler Systems in the Power Plant (발전용 보일러 시스템의 이상허용 및 과도상태의 유연한 제어에 관한 연구)

  • Kwon, Oh-Kyu;Lee, Young-Sam
    • Proceedings of the KIEE Conference
    • /
    • 1998.11b
    • /
    • pp.689-692
    • /
    • 1998
  • In this research a fault-tolerant and bumpless switching control is proposed for boiler systems used in the power plants. Firstly, three operating points are selected to control the nonlinear boiler through the full operational range, and the $H_{\infty}$ loop shaping controller and the model-based predictive controller(MBPC) are designed. To prevent the windup and bump problems which are caused by the actuator saturation and the controller switching, an anti-windup and bump less transfer technique is adopted to the $H_{\infty}$ loop shaping controller. Also the constrained gain-scheduling technique is applied to MBPC to achieve the same objective. Secondly, the fault-tolerant control technique is proposed to continue the control action without stopping the boiler operation even in case of some faults. Through various simulation studies, the performances of the proposed control techniques are demonstrated.

  • PDF

A Study en the Fault-Tolerant and Bumpless Switching Control for Boiler Systems in the Power Plant (발전용 보일러 시스템의 이상허용 및 과도상태의 유연한 제어에 관한 연구)

  • Kwon, Oh-Kyu;Lee, Young-Sam
    • Proceedings of the KIEE Conference
    • /
    • 1998.11a
    • /
    • pp.369-372
    • /
    • 1998
  • In this research a fault-tolerant and bumpless switching control is proposed for boiler systems used in the power plants. Firstly, three operating points are selected to control the nonlinear boiler through the full operational range, and the $H_{\infty}$ loop shaping controller and the model-based predictive controller(MBPC) are designed. To prevent the windup and bump problems which are caused by the actuator saturation and the controller switching, an anti-windup and bumpless transfer technique is adopted to the $H_{\infty}$ loop shaping controller. Also the constrained gain-scheduling technique is applied to MBPC to achieve the same objective. Secondly, the fault-tolerant control technique is proposed to continue the control action without stopping the boiler operation even in case of some faults. Through various simulation studies, the performances of the proposed control techniques are demonstrated.

  • PDF

three phase current reconstruction method applying predictive current in three shunt sensing PWM inverter (예측 전류를 적용한 3 션트 PWM 인버터의 전류 복원 기법)

  • Hong, Sung-Woo;Kim, Do-Yun;Won, Il-Kuen;Kim, Young-Real;Won, Chung-yuen
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.99-100
    • /
    • 2016
  • In a AC motor used by three phase inverter, the phase current must be measured to control instantaneous torque. It is expensive to use current sensor for measuring current in low cost motor. So, shunt resistor is used to measure current. But, the method sensing the phase current using shunt resistor cannot perform the vector control in high speed because of the area that impossible to restore three phase current. In this paper, predictive current is proposed for reconstructing the current in the impossible current sensing area that reduce the current ripple in TSSI(Three shunt sensing inverter) for PMSM.

  • PDF

Optimal Zero Vector Selecting Method to Reduce Switching Loss on Model Predictive Control of VSI (전압원 인버터의 모델 예측 제어에서 스위칭 손실을 줄이기 위한 최적의 제로 벡터 선택 방법)

  • Park, Jun-Cheol;Kwak, Sangshin
    • Proceedings of the KIPE Conference
    • /
    • 2014.11a
    • /
    • pp.23-24
    • /
    • 2014
  • 본 논문은 전압원 인버터를 모델 예측 제어 (Model Predictive Control)를 하는데 있어 스위칭 손실을 줄이기 위한 제로 벡터 (zero-vector) 선택 방법을 제안한다. 기존의 전압원 인버터의 모델 예측 제어는 제로 벡터의 중복을 선택하는 방법이 제시되지 않아, 이에 대한 연구가 필요하다. 본 논문에서는 제로 벡터의 중복을 선택하는 방법으로 스위칭 손실을 줄이기 위한 제로 시퀀스 전압을 생성하고, 생성된 제로 시퀀스 전압의 부호를 통해 제로 벡터의 중복을 선택하였다. 따라서 전류의 품질은 그대로 유지시키는 동시에 스위칭 손실을 감소시킬 수 있다. 이를 시뮬레이션으로 검증하였다.

  • PDF

ESS Optimal Charge-Discharge Schedule Generation Method Using Model Predictive Control Framework (모델예측제어 프레임워크를 이용한 ESS 최적 충방전스케줄 생성기법)

  • Sim, Jin-Yong;Lim, Jong-Mok;Jung, Sug-In;Kim, Jae-Hyun;Hong, Seung-Pyo;Shin, Jae-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2019.11a
    • /
    • pp.232-233
    • /
    • 2019
  • ESS(Energy Storage System)의 도입을 통해 첨두부하의 경감(Peak Shaving)과 일종의 차익거래(Arbitrage) 효과를 실현할 수 있다. 본 논문에서는 경제적 이득의 극대화를 지향하는 ESS 최적 충방전스케줄 생성기법을 제안한다. 제안 기법은 모델예측제어(MPC: Model Predictive Control) 프레임워크를 기반으로 하였고 매트랩 시뮬레이션을 통하여 그 타당성을 검증하였다.

  • PDF