• Title/Summary/Keyword: predicted mean vote

Search Result 89, Processing Time 0.025 seconds

Evaluation on Thermal Environment Installed Ventilating Fans in the Rotunda at New National Museum of Korea (기류유인팬을 이용한 새 국립중앙박물관 로튠다에서의 열환경 평가)

  • 이승철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.3
    • /
    • pp.303-309
    • /
    • 2004
  • In order to improve thermal comfort in the Rotunda, which is high and wide visiting space of the new national museum of Korea, eight ventilating fans were installed near the ceiling of Rotunda. It has been analyzed thermal comfort of Rotunda with/without ventilating fans by numerical simulation. To evaluate thermal comfort of the Rotunda, well-known indices, PMV and PPD were introduced. The results of present investigation show that temperature distribution of the case with fans is closer to target temperature than the case with-out fans at the breathing zone. In the case without fans, thermal stratification with 16$^{\circ}C$ of temperature difference occurs along the height of the Rotunda which makes the thermal environment worse and the PPD values reach up to 50% in the 6th floor connection passage. In the case with fans, however, the vertical temperature difference were reduced to 9$^{\circ}C$ and the PPD values were lower below 20%. Consequently, the ventilating fans adopted on this study are effectively used for improving the thermal comfort in large space structure with thermal stratification.

Evaluation of Thermal Comfort and Cooldown Performance inside Automotive Cabin according to Air-conditioning Vent Location (인체모델을 고려한 자동차 실내의 에어컨 토출구 위치 변화에 따른 냉방성능 및 온열쾌적성 평가)

  • Seo, Jin-Won;Park, Jae-Hong;Choi, Yun-Ho
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.20 no.5
    • /
    • pp.120-129
    • /
    • 2012
  • As the recent advancement of automobile industry, there has been a great interest in the thermal comfort of the passengers inside the cabin of an automobile. Thermal comfort is affected by temperature, velocities, and mean radiation temperature of air, thermal resistance of clothes and physical active level of human. The present study performed computational analysis to select the location of air-conditioning vent that improves thermal comfort inside the cabin. In order to do this, we considered various air vent positions, and thermal flow analysis of each case is performed using CFD for the cabin with four passengers. The thermal comfort is evaluated using the computational results and the optimum location of air vent is suggested.

Comparison of Thermal Effects of Different School Ground Surface Materials - A Case of Yooljeon Elementary School- (학교운동장 피복물질 간의 온열효과 비교 - 율전초등학교를 대상으로 -)

  • LIM, Joong-Bin;YU, Jinhang;LEE, Ju-Yeol;LEE, Kyoo-Seock
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.18 no.2
    • /
    • pp.28-44
    • /
    • 2015
  • Granite soil has been used traditionally as a school playground surface. Natural turf has also been used in some schools. Recently artificial turf has come into common use instead of granite soil or natural turf. Artificial turf playgrounds are used at 174 schools in Seoul, Korea. More than 3,500 artificial turf fields are installed in the United States. Because of the increase of artificial turf usage, there are many studies about the estimation of artificial turf effects to environment. Compared with artificial turf material effects such as characterization of substances released from material, and recognition of volatility of heavy metal into the surrounding environment - air or the percolating rainwater -, less studies for thermal effects of artificial turf playground have been done. Especially, the corresponding studies in Korea are few. Thus, the purpose of this research is to compare the thermal effects of artificial turf on school playground between natural turf and granite soil. In this study, air temperature and Predicted Mean Vote (PMV) were compared in three scenarios by Computational Fluid Dynamics (CFD) model. Additionally, the results were validated through a field measurement. Air temperature decreasing effects by natural turf are greater than those by artificial turf and granite soil at 14:30 on 20th, July 2011. It shows the same decreasing effects at 23:30. However, the difference is less than that of daytime. PMV differences between natural turf and the other two surface covers are large at daytime while those are much less at nighttime. Consequently, air temperature and PMV of artificial turf are the highest among three school playground surface pavements.

Effect of Thermal Environment and Illuminance on the Occupants Works based on the Electroencephalogram and Electrocardiogram Analysis (뇌파와 심전도 분석을 기반으로 한 온열환경 및 조도가 재실자의 업무에 미치는 영향)

  • Kim, Hyung-Sun;Lim, Jae-Hyun;Kim, Hyoung-Tae;Kim, Hyoung-Sik;Kuwak, Won-Tack;Kim, Jin Ho
    • Science of Emotion and Sensibility
    • /
    • v.17 no.3
    • /
    • pp.95-106
    • /
    • 2014
  • This research analyzed biosignals associated with the change of emotion from lighting felt by the occupants and task type under various indoor thermal environments and illuminance, and examined the biosignals' impacts on work. To this end, the indoor thermal environment was constructed on the basis of PMV (predicted mean vote) index value, and various indoor environments were created by changing the brightness of LED stands. In this manner, a variety of indoor environments were constructed, and experiments were carried out. This research evaluates the sensibility response to lighting through a questionnaire survey in the given environment and incorporates different types of error searches. In this way, changes were analyzed by measuring electroencephalogram (EEG) and electrocardiograms (ECG). As a result, all biosignals on the task type showed significant differences from the thermal environment change. When PMV index value was 0.8 (temperature: $25^{\circ}C$, humidity: 50 %), concentration and attention were the most activated. However, the biosignals did not show significant differences from the illuminance change. Concentration on an occupant's work capability was confirmed to be closely related to the thermal environment. As for the subjective emotional response to lighting, the occupants felt comfort as illuminance was lower, while they felt discomfort as illuminance was higher. However, there were no significant differences from the thermal environment change.

Thermal Comfort and the Physiological and Psychological Effects of Spending Time in Broad-Leaved Forests in Summers (여름철 활엽수림에서의 휴식이 온열환경 쾌적성 및 인체의 생리ᐧ심리적 반응에 미치는 영향)

  • Juhyeon Kim;Injoon Song;Choyun Kim;Dawou Joung;Yunjeong Yi;Bum-Jin Park;Chorong Song
    • Journal of Korean Society of Forest Science
    • /
    • v.112 no.4
    • /
    • pp.544-553
    • /
    • 2023
  • The purpose of this study was to reveal the thermal comfort and physiological and psychological effects of spending time in broad-leaved forests in suumer. Thirty-one university students (with an average age of 21.4 ± 2.1 years) participated in the study, and a within-subjects experimental design methodology was used. The participants moved to an experimental site (with a crown closure of 76.6%) or a control site (25.9%), sat on a chair to eliminate the impact of movement, and rested for 5 minutes with closed eyes. At this time, thermal comfort, heart rate variability, heart rate, and forehead temperature were continuously measured. After that, blood pressure and pulse rate were measured, and a subjective evaluation was conducted. As a result, spending time at an experimental site showed a statistically significant decrease in the predicted mean vote and the percentage of dissatisfied values, enhancement of parasympathetic nerve activity, decrease of forehead temperature, diastolic blood pressure, heart rate, pulse rate, and improvement of personal thermal sensation (thermal sensation vote and comfort sensation vote). In conclusion, it was found that a forest with high crown closure reduces thermal stress and induces physiological and psychological relaxation.

Evaluation of Thermal Comfort and Ventilation Performance in the Lecture Room with Ventilation System and Two Different Air-conditioning Systems: System Air-conditioner or Fan Coil Unit (환기시스템 설치 강의실에서 시스템에어컨과 팬코일유닛의 열쾌적성 및 환기성능 평가)

  • Han Chang-Woo;Noh Kwang-Chul;Oh Myung-Do
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.11
    • /
    • pp.1079-1087
    • /
    • 2005
  • In this paper, thermal comfort and ventilation performance characteristics in the lecture room with the ventilation system and two different air-conditioning systems, system air-conditioner or fan coil unit, were evaluated by experimental and numerical methods. We compared the measured data with the computational results of the predicted mean vote and carbon dioxide concentration. Additionally the ventilation effectiveness was calculated numerically. From a viewpoint of the uniformity of PMVs in the lecture room, the thermal distribution performance of the system air-conditioner was more effective than the fan coil unit. Carbon dioxide concentration and ventilation effectiveness were barely affected by the type of the air-conditioning system.

Metabolic Rate Estimation for ECG-based Human Adaptive Appliance in Smart Homes (인간 적응형 가전기기를 위한 거주자 심박동 기반 신체활동량 추정)

  • Kim, Hyun-Hee;Lee, Kyoung-Chang;Lee, Suk
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.20 no.5
    • /
    • pp.486-494
    • /
    • 2014
  • Intelligent homes consist of ubiquitous sensors, home networks, and a context-aware computing system. These homes are expected to offer many services such as intelligent air-conditioning, lighting control, health monitoring, and home security. In order to realize these services, many researchers have worked on various research topics including smart sensors with low power consumption, home network protocols, resident and location detection, context-awareness, and scenario and service control. This paper presents the real-time metabolic rate estimation method that is based on measured heart rate for human adaptive appliance (air-conditioner, lighting etc.). This estimation results can provide valuable information to control smart appliances so that they can adjust themselves according to the status of residents. The heart rate based method has been experimentally compared with the location-based method on a test bed.

An Analysis of Human Reaction & IAQ Analysis by Changing the Floor Temperature & Ventilation (바닥온도와 실내 환기에 따른 인체반응 및 실내공기질 분석)

  • Lee, Ji-Weon;Chin, Kyung-Il;Kim, Se-Hwan
    • KIEAE Journal
    • /
    • v.15 no.1
    • /
    • pp.97-102
    • /
    • 2015
  • Recently many buildings are airtight, deterioration takes the high stage. As this room ventilation is increasingly difficult, the importance of indoor air was emphasized. And Got a few provisions on the indoor ventilation, the building is used for other purposes also requires a lot of careful research. In this study, consisting of floor heating ventilation in the room and wants to know the impact on the human body react with the carbon dioxide concentration in the indoor air were investigated PMV. We have get the data through the experimental study like this. It can be inferred correlations of ventilation and temperature according to human comfort that you should consider when using the work of residential buildings in accordance with the changing social conditions and social. It is also determined that in the future through additional experiments related data can be established basic experimental data.

Experimental Analysis of Thermal Comfort of an Office Space for Ceiling and Floor Supply Air Conditioning Systems (사무실 공간의 냉방시 천장 및 바닥 급기 공조 방식에 따른 열환경 평가 실험)

  • Cho, Yong;Kwon, Hyurk-Seung;Kim, Sung-Hyun;Kim, Young-Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.9
    • /
    • pp.810-816
    • /
    • 2000
  • Thermal comfort plays an important role in modern office buildings. Four major factors affecting thermal comfort are air temperature, velocity, humidity and radiation temperature. Distribution of these thermal factors in indoor space depends largely on the air flow which is related to the method of supplying and extracting air. In this study, an experimental analysis on indoor thermal comfort is conducted to study the difference between a ceiling supply cooling system and a floor supply one. The two cooling systems are applied to an office space during summer season and the distributions of temperature, velocity, radiation temperature and PMV are measured. Results show that the floor supply cooling system is superior in terms of thermal comfort and energy saving. Studies need to be done, however, to reduce the vertical temperature difference of a floor supply air conditioning system.

  • PDF

Evaluation of Environmental Comfort of Tractor Cabs (트랙터 안전캡의 환경 쾌적성 평가)

  • Hwang, Ki-Young;Kim, Kyeong-Uk
    • Journal of Biosystems Engineering
    • /
    • v.34 no.1
    • /
    • pp.1-7
    • /
    • 2009
  • In order to evaluate environmental comfort of tractor cabs, temperature, relative humidity and noise within the cab were taken from 31 tractors during plowing and rotovating operations. The temperature and humidity were evaluated with regard to the comfort zone of KS B ISO 14269-2 and PMV of ISO 7730. The noise was evaluated with regard to the permissible sound level of OSHA for daily exposure of 8 hours. The collected data indicated that thermal environment of the cabs was out of the comfort zone, which meant tractor operators worked under uncomfortable thermal conditions. Difference in the thermal comfort by tractor power and maker, and type of works was not found. However, 25% of the studied tractors showed PMV in a range of -0.5 to +0.5, which indicated their operators worked under the comfort criteria. PMV was improved when the cab was air-conditioned. Levels of measured cab noise were lower than the permissible criteria, and 76.7% of the studied tractors had cab noise ranged from 75 to 85 dBA. There was a tendency that high powered tractors, rotovating operations and locally-made tractors had greater cab noise levels. However, their differences were insignificant.