• Title/Summary/Keyword: precision validation

Search Result 556, Processing Time 0.034 seconds

Validated HPLC Method for the Pharmacokinetic Study of Atenolol and Chlorthalidone Combination Therapy in Korean Subjects

  • Kang, Hyun-Ah;Kim, Hwan-Ho;Kim, Se-Mi;Yoon, Hwa;Cho, Hea-Young;Oh, Seaung-Youl;Choi, Hoo-Kyun;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.36 no.5
    • /
    • pp.331-338
    • /
    • 2006
  • A rapid, selective and sensitive reverse-phase HPLC methods for the determination of atenolol and chlorthalidone in human serum and whole blood were validated, and applied to the pharmacokinetic study of atenolol and chlorthalidone combination therapy. Atenolol and an internal standard, pindolol, were extracted from human serum by liquid-liquid extraction, and analyzed on a $\mu$-Bondapak C18 $10-{\mu}$ column in a mobile phase of methanol-0.01 M potassium dihydrogenphosphate(30:70, v/v, adjusted to pH 3.5) and fluorescence detection(emission: 300 nm, excitation: 224 nm). Chlorthalidone and an internal standard, probenecid, were extracted form human whole blood by liquid-liquid extraction, and analyzed on a Luna C18 $5-{\mu}$ column in a mobile phase of acetonitrile containing 77% 0.01 M sodium acetate and UV detection at 214 nm. These analysis were performed at three different laboratories using the same quality control(QC) samples. The chromatograms showed good resolution, sensitivity, and no interference by human serum and whole blood, respectively. The methods showed linear responses over a concentration range of 10-1,000 ng/mL for atenolol and 0.05-20 ${\mu}g/mL$ for chlorthalidone, with correlation coefficients of greater than 0.999 at all the three laboratories. Intra- and inter-day assay precision and accuracy fulfilled international requirements. Stability studies(freeze-thaw, short-, long-term, extracted sample and stock solution) showed that atenolol and chlorthalidone were stable. The lower limit of quantitation of atenolol and chlorthalidone were 10 ng/mL and 0.05 ${\mu}g/mL$, respectively, which was sensitive enough for pharmacokinetic studies. These methods were applied to the pharmacokinetic study of atenolol and chlorthalidone in human volunteers following a single oral administration of Hyundai $Tenoretic^{\circledR}$ tablet(atenolol 50 mg and chlorthalidone 12.5 mg) at three different laboratories.

The Development of Growth and Yield Models for the Natural Broadleaved-Korean Pine Forests in Northeast China (중국(中國) 동북부(東北部) 지방(地方) 활엽수(闊葉樹)-잣나무 천연림(天然林)의 생장(生長) 모델과 수확(收穫) 모델 개발(開發))

  • Li, Fengri;Choi, Jung-Kee;Kim, Ji-Hong
    • Journal of Korean Society of Forest Science
    • /
    • v.90 no.5
    • /
    • pp.650-662
    • /
    • 2001
  • The growth and yield models for five different kinds of natural forest types were systemically developed in the natural Broadleaved-Korean pine Forests in Northeast China. The data were collected from 359 temporary plots and 58 permanent plots with area ranged from 0.06 ha to 1.0 ha, ranging in stand age from 43 to 364 years. The Site Class Index (SCI) was introduced to evaluate site quality and the Crown Competition Factor (CCF) was selected as a measure of stand density for the mixed natural forest. The Chapman-Richards function was adopted to develop SCI equation and height-diameter curve. The Schumacher growth function was selected as base model to develop the DBH, basal area, and stand volume growth models by using re-parameterized method. In modeling mean DBH and basal area growth, it was found that the asymptotic parameter A of Schumacher function was exponentially related to site quality (SCI) and stand density (CCF). The rate parameter k was related to stand density and it was independent of SCI. Several validation measures for predicted stand variables were evaluated in the growth and yield models using independent data sets. The results indicated that relative mean errors (RME) in predicted stand attributes were less than ${\pm}5%$ and the estimated precision values of the stand variables were all greater than 95%.

  • PDF

A Study on Standardization of Shinbaro Pharmacopuncture Using Herbal Medicines Identification Test and HPLC-DAD (신바로 약침의 한약재 확인시험 및 HPLC-DAD를 통한 표준화 연구)

  • Lee, Jin Ho;Kim, Min Jeong;Lee, Jae Woong;Kim, Me Riong;Lee, In Hee;Kim, Eun Jee
    • Journal of Acupuncture Research
    • /
    • v.32 no.2
    • /
    • pp.1-9
    • /
    • 2015
  • Objectives : The present study was an evaluation and standardization of herbal components in order to establish the efficacy and safety of Shinbaro pharmacopuncture. Methods : Among the raw materials of Shinbaro pharmacopuncture, the components Cibotii Rhizoma, Eucommiae Cortex, and Ledebouriellae Radix were assessed through ingredient verification experiments using thin-layer chromatography(TLC) and ultraviolet rays(UV) lamps. In addition, we standardized Acanthopanacis Cortex and Achyranthis Radix through validation using high performance liquid chromatograph-diode array detector(HPLC-DAD). Results : As result appeared a blue-white fluorescence under ultraviolet rays; changed to dark green after adding 1 % ferric chloride solution(due to Cibotii Rhizoma), and presented a yellow-green fluorescence when mixed with an ethyl ether under UV lamps by way of the ethyl ether layer, confirming Eucommiae Cortex. Ledebouriellae Radix was confirmed as dark brown spots at Rf values of 0.56 and 0.71 using TLC. Additionally, Acanthopanacis Cortex and Achyranthis Radix HPLC test results showed that linearity was $R^2{\geq}0.99$, and detection limit and quantitation limit were 0.23 to $1.29{\mu}g/mL$, and 0.71 to $3.90{\mu}g/mL$, respectively. Furthermore, precision and accuracy were confirmed to have relative standard deviation(RSD) values of 0.10 to 1.89 % and 96.19 to 103.72 %, respectively. Shinbaro pharmacopuncture did not have any overlapping or interference from other peaks in detection under the abovementioned analysis conditions. Conclusions : In conclusion, we confirmed that maintenance of Shinbaro pharmacopuncture validity was possible by means of quality control of Cibotii Rhizoma, Eucommiae Cortex, and Ledebouriellae Radix through ingredient identification and Acanthopanacis Cortex and Achyranthis Radix through high performance liquid chromatograph(HPLC) analysis. Further, we hope to contribute to the development strategy of herbal industry acupuncture.

Analysis of Methamphetamine and Amphetamine in Oral Fluid of Eleven Drug Abusers (마약남용자 11명의 타액 중 메스암페타민의 분석)

  • Kim, Eun-Mi;Lee, Ju-Seon;Choi, Hye-Young;Choi, Hwa-Kyung;Chung, Hee-Sun
    • YAKHAK HOEJI
    • /
    • v.52 no.6
    • /
    • pp.419-425
    • /
    • 2008
  • A qualitative and quantitative analytical method was developed for detection of methamphetamine (MA) and its main metabolite amphetamine (AM) in oral fluid. Oral fluids of eleven drug abusers were provided by Police, specimens were collected by stimulation with a cotton swab treated with 20 mg of citric acid ($Salivette^{(R)}$; Sarstedt, USA). As the preliminary test, oral fluid samples were screened for amphetamines by Fluorescence Polarization Immunoassay (TDxFLx, Abbott Co.). Extraction for MA was performed using solid-phase extraction (SPE) by $RapidTrace^{TM}$ (Zymark, USA) with mixed mode cation exchange cartridge, CLEAN $SCREEN^{(R)}$ (130 mg/3 ml, UCT) after dilution with phosphate buffer. Samples were evaporated and derivatized by pentafluoropropionic acid anhydride (PFPA). Quantitation of MA and AM was performed by gas chromatography-mass spectrometry (GC-MS) using selective ion monitoring (SIM), the quantitation ions were m/z 204 (MA), 208 (MA-$D_5$), 190 (AM) and 194 (AM-$D_5$). The selectivity, linearity of calibration, limit of detection (LOD) and quantification (LOQ) within- and between day precision, accuracy and recoveries were examined as parts of the method validation. All oral fluid samples gave positive results to immunoassay for MA (cut-off level, 50 ng/ml as d-amphetamine). Concentrations of MA and AM by GC-MS in eleven samples were ranged 104.2${\sim}$4603.3 ng/ml and 32.4${\sim}$268.6 ng/ml, respectively. Extracted calibration curves of MA and AM were linear over the two concentration range of 1${\sim}$100 and 50${\sim}$1000 ng/ml with correlation coefficient of above 0.999. LOQ of MA and AM was 1 and 3 ng/ml, respectively. The intraand inter-day run precisions (CV) for MA and AM were less than 10%, and the accuracies (bias) for MA and AM were also less than 10% at the two different concentrations 5 and 100 ng/ml at low calibration range, 50 and 1000 ng/ml at high calibration range. The absolute recoveries of MA and AM at low and high calibration ranges were more than 82% and 75%, respectively. In this study the qualitative and quantitative analytical method of MA in oral fluid was established. Oral fluid testing may detect drug use in past hours because of its shorter detection window than urine, and be useful in post-accident situations. So oral fluids will be most useful for testing drug abuse in the driving under the influence of drug (DUID) as the alternative specimens of urine.

Determination of 10${\alpha}$-Methoxy-9,10-dihydrolysergol (MDL), Main Metabolite of Nicergoline, in Human Plasma by HPLC-MS and Applicability to Oral Bioavailability in Korean Healthy Male Volunteers (HPLC-MS를 이용한 생체시료 중 니세르골린의 주대사체인 10${\alpha}$-Methoxy-9,10-dihydrolysergol(MDL)의 분석 및 이를 이용한 한국인 성인 남성에 대한 생체이용률 응용)

  • Lim, Hyon-Kyun;Yoo, Sun-Dong;Kim, Kyeong-Ho;Han, Sang-Beom;Youm, Jeong-Rok
    • YAKHAK HOEJI
    • /
    • v.51 no.2
    • /
    • pp.133-139
    • /
    • 2007
  • A simple and sensitive HPLC-MS method for quantitation of 10${\alpha}$-methoxy-9,10-dihydrolysergol (MDL), the main metabolite of nicergoline, in human plasma was developed and the bioavailability parameters of MDL was assessed in Korean healthy male volunteers. Clomipramine was used as an internal standard. MDL and internal standard in plasma sample were extracted using ethyl acetate. A centrifuged upper layer was then evaporated and reconstituted with mobile phase of 10 mM ammonium acetate-acetonitrile (10 : 90, v/v). The reconstituted samples were injected into a Zorbax SB-C8 column (2.1${\times}$150 mm,5 ${\mu}$m) at a flow-rate of 0.3 ml/min. Using MS with selected ion monitoring (SIM) mode, MDL and clomipramine were detected without severe interference from human plasma matrix. MDL produced a protonated molecular ion ([M+H]$^+$) at m/z 287. Internal standard produced a protonated molecular ion ([M+H]$^+$) at m/z 315. A linear relationship for MDL was found in the range of 2.5${\sim}$100 ng/ml. The lower limit of quantitation (LLOQ) was 2.5 ng/ml with acceptable precision and accuracy. The intra- and inter-day validation for all coefficients of variation (R.S.D.%) were found less than 15%. Main pharmacokinetic parameters of 30 mg of nicergoline were revealed as follows: AUC$_t$ 321.1${\pm}$64.5 ng${\cdot}$hr/ml, C$_{max}$, 51.2${\pm}$25.3 ng/ml, T$_{max}$ 3.6${\pm}$1.5 hr, K$_{el}$ 0.12${\pm}$0.07 hr$^{-1}$ and t$_{1/2}$ 7.6${\pm}$3.4 hr. Inter subject variations and race differences were shown in comparison with the published data in the literature.

Replacement of the in vivo Bioassay for Erythropoietin with the in vitro Bioassay (Erythropoietin in vivo 시험법의 in vitro 대체 시험법 확립)

  • 백상훈;김진만;권기성;박송용;허재욱
    • KSBB Journal
    • /
    • v.18 no.4
    • /
    • pp.255-260
    • /
    • 2003
  • In vivo bioassays for biological medicines have been considered final resort to unequivocally assess the biological activities for them because there are some cases in which the biological activities obtained from in vivo bioassay and in vitro bioassay quite differ each other. The in vivo biological activity of EPO depends on its sialic acid contents which confer microheterogeneity-isoforms to this protein. We have devise a method which consists of a in vitro bioassay using BaF3 cell line and a capillary zone electrophoresis (CZE) for the measurement of the EPO isoform distribution. The biological activity of EPO obtained using in vitro bioassay with BaF3 cell line showed good correlation (C.V.(%) 7.34, 5.85, 8,16, 8.08, 8.8) to EPO content measured either spectrophotometric assay (A280 0.1 % =0.743) or radio immunoassay. The assay validation results of in vitro bioassay with 3 lot of in house EPO showed good results to EPO content measured either in vivo assay or radio immunoassay. and also showed good results the robustness of our method in terms of precision, accuracy, repeatability. The isoform distribution for EPO-BRP (1 : 1 mixture of epoetin-${\alpha}$ and epoetin-${\beta}$, European Pharmacopoeia) by CZE method resulted in isoform 2 through isoform 8. The major peaks in electrophoregram were composed of isoform 3 through 7. Our recombinant EPO (epoetin-${\alpha}$) having equivalent in vivo biological activity showed the isoform distribution of isoform 3 through 9. The major peaks consisted of isoform 4 through 8. The peak area of isoform 4 was always smaller than that of isoform 5. The preparations of recombinant epoetin-${\alpha}$ with lower in vivo biological activity than EPO-BRP showed the isoform 2 through 8 in their electrophoregrams whose major peaks consisted of the isoform 3 through 7. The peak area of isoform 4 was larger than that of isoform 5.

Bioequivalence of Atorva Tablet® to Lipitor Tablet® (Atorvastatin 20 mg) (리피토정® (아토르바스타틴 20 mg)에 대한 아토르바정®의 생물학적동등성)

  • Lim, Hyun-Kyun;Lee, Tae-Ho;Lee, Jae-Hyun;Youm, Jeong-Rok;Song, Jin-Ho;Han, Sang-Beom
    • Journal of Pharmaceutical Investigation
    • /
    • v.38 no.2
    • /
    • pp.135-142
    • /
    • 2008
  • The present study describes the evaluation of the bioequivalence of two atorvastatin tablets, Lipitor $Tablet^{(R)}$ (Pfizer, reference drug) and Atorva $Tablet^{(R)}$ (Yuhan, test drug), according to the guidelines of Korea Food and Drug Administration (KFDA). Forty-nine healthy male Korean volunteers received each medicine at the atorvastatin dose of 40 mg in a $2{\times}2$ crossover study with a two weeks washout interval. After drug administration, serial blood samples were collected at a specific time interval from 0-48 hours. The plasma atorvastatin concentrations were monitored by an high performance liquid chromatography -tandem mass spectrometer (LC-MS/MS) employing electrospray ionization technique and operating in multiple reaction monitoring (MRM) and positive ion mode. The total chromatographic run time was 4.5 min and calibration curves were linear over the concentration range of 0.1-100 ng/mL for atorvastatin. The method was validated for selectivity, sensitivity, linearity, accuracy and precision. $AUC_t$ (the area under the plasma concentration-time curve from time zero to 48hr) was calculated by the linear log trapezoidal rule method. $C_{max}$ (maximum plasma drug concentration) and $T_{max}$ (time to reach $C_{max}$) were complied trom the plasma concentration-time data. Analysis of variance was carried out using logarithmically transformed $AUC_t$ and $C_{max}$. No significant sequence effect was found for all of the bioavailability parameters indicating that the crossover design was properly performed. The 90% confidence intervals of the $AUC_t$ ratio and the $C_{max}$ ratio for Atorva $Tablet^{(R)}$ / Lipitor $Tablet^{(R)}$ were ${\log}\;0.9413{\sim}{\log}\;1.0179$ and ${\log}\;0.831{\sim}{\log}\;1.0569$, respectively. These values were within the acceptable bioequivalence intervals of ${\log}\;0.8{\sim}{\log}\;1.25$. Based on these statistical considerations, it was concluded that the test drug, Atorva $Tablet^{(R)}$ was bioequivalent to the reference drug, Lipitor $Tablet^{(R)}$.

Development of HPLC-UV method for detection and quantification of seven organic acids in animal feed (사료 중 유기산 7종 동시분석법 개발 및 유통 사료의 모니터링)

  • Kim, Jin kug;Lee, Mi Jin;Lee, Ye Ji;Kim, Hye Jin;Jeong, Min Hee;Kim, Ho Jin
    • Analytical Science and Technology
    • /
    • v.29 no.4
    • /
    • pp.202-208
    • /
    • 2016
  • 본 연구에서는 사료 첨가제로 이용되고 있는 유기산 7종(formic acid, malic acid, lactic acid, acetic acid, citric acid, fumaric acid, propionic acid)의 동시분석법 개발을 위한 연구를 실시하였다. 7종의 화합물은 표준물질의 Retention time과 UV spectra를 통해 구별하였고, 분석법 검증은 직선성, 민감성, 선택성, 정확성, 정밀성을 통하여 검증하였다. 그 결과로 LOD와 LOQ의 범위가 각각 43~26,755 μg/kg, 12-8,026 μg/kg으로 설정하였고, 평균 회수율이 79.3~95.2%로 우수하게 보였으며, intra-day, inter-day에 대한 전반적인 상대 표준 편차(%RSD)는 3.2% 미만으로 나타났다. 이와 같이 검증된 자료를 통해 유기산의 동시분석에 대한 직선성, 민감성, 선택성, 정확성 및 정밀성을 확인하였고, 높은 수준을 나타냄을 알 수 있었다. 이를 바탕으로 유기산이 검출되는 단미사료 46 가지를 분석에 적용하여 진행하였고, 정량과 동시분석 검출을 위한 방법은 RP-HPLC/UV 검출기를 이용하여 성공적으로 개발되었다. 따라서 본 연구결과를 바탕으로 하여 사료 중의 유기산의 분석이 신속하고 정확해졌을 뿐 아니라, 다른 종류의 사료 또한 이를 적용하여 효율적으로 이용할 수 있을 것으로 판단된다.

Screening of anti-obesity drugs, their analogues and prohibited ingredients in slimming foods (식품 중 부정 혼입된 비만치료제 및 사용금지 성분 실태조사)

  • Yun, Jisuk;Choi, Jangduck;Kwon, Kisung;Jo, Cheon-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.48 no.5
    • /
    • pp.424-429
    • /
    • 2016
  • Globally, obesity has been recognized as a serious health problem. Recently, slimming foods for weight loss and maintenance were found to contain anti-obesity drugs, their analogues, and prohibited ingredients. To avoid inspections by the Government, structurally modified analogs have been continuously synthesized. For rapid determination of adulterated slimming products, we simultaneously analyzed 21 illegal compounds using liquid chromatography (LC) equipped with photo diode array, and LC coupled with tandem mass spectrometry. The validation of the method was performed with regard to selectivity, linearity, limit of detection, limit of quantification, precision, and accuracy. We purchased 128 samples from the Korean market and online sources in the year 2015. In 31 samples, 3 illegal compounds were detected as follows: 9.9-135.3 mg/g of sibutramine, 0.2-17.5 mg/g of yohimbine, and 1.8 mg/g of icariin. This simultaneous detection method might prove to be a simple and rapid analysis for monitoring illegal compounds in slimming foods.

Protein Interaction Possibility Ranking Method based on Domain Combination (도메인 조합 기반 단백질 상호작용 가능성 순위 부여 기법)

  • Han Dong-Soo;Kim Hong-Song;Jong Woo-Hyuk;Lee Sung-Doke
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.11 no.5
    • /
    • pp.427-435
    • /
    • 2005
  • With the accumulation of protein and its related data on the Internet, many domain based computational techniques to predict protein interactions have been developed. However, most of the techniques still have many limitations to be used in real fields. They usually suffer from a low accuracy problem in prediction and do not provide any interaction possibility ranking method for multiple protein pairs. In this paper, we reevaluate a domain combination based protein interaction prediction method and develop an interaction possibility ranking method for multiple protein pairs. Probability equations are devised and proposed in the framework of domain combination based protein interaction prediction method. Using the ranking method, one can discern which protein pair is more probable to interact with each other than other protein pairs in multiple protein pairs. In the validation of the ranking method, we revealed that there exist some correlations between the interacting probability and the precision of the prediction in case of the protein pair group having the matching PIP(Primary Interaction Probability) values in the interacting or non interacting PIP distributions.