• Title/Summary/Keyword: precision safety inspection

Search Result 65, Processing Time 0.018 seconds

Optical Fiber-Based Hybrid Nerve Measurement System for Static and Dynamic Behavior of Structures (구조물의 정적 및 동적 거동 모니터링을 위한 광섬유 기반 하이브리드 신경망 계측 시스템)

  • Park, Young-Soo;Song, Kwang-Yong;Jin, Seung-Seop;Park, Young-Hwan;Kim, Sung-Tae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.2
    • /
    • pp.33-40
    • /
    • 2020
  • Various studies have been conducted on the structural health monitoring using optical fiber. Optical fibers can be used to measure multiple and distributed strain. Among the optical fiber sensors, FBG sensor has advantages of dynamic response measurement and high precision, but the number of measurement points is limited. Distributed fiber sensors, represented by distributed Brillouin sensors, usually have more than 1000 measurement points, but the low sampling rate makes dynamic measurements impossible. In this study, a hybrid nerve sensor system using only the advantages of the FBG sensor and the distributed Brillouin sensor has been proposed. Laboratory experiments were performed to verify the proposed system, and the accuracy and reproducibility were verified by comparing with commercial sensors. Applying the proposed system, dynamic response ambient measurements are used to evaluate the global state of the structure. When an abnormal condition is detected, the local condition of the structure is evaluated by static response measurement using the distributed measurement system. The proposed system can be used for efficient structural health monitoring.

A Review of the Deterioration and Damage of the Top Flange of the Highway PSC Box Girder Bridge based on the Condition Assessment Results (상태평가 결과 기반 고속도로 PSC Box 거더교 상부플랜지 열화·손상 실태 고찰)

  • Ku, Young-Ho;Han, Sang-Mook
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.6
    • /
    • pp.23-32
    • /
    • 2022
  • Although PSCB girder bridges account for 4% of the bridges in use on highways, they do not account for much, but 98% of PSCB girder bridges are 1st type and 2nd type of bridge. Also, the total length of the PSCB girder bridge is 16% (192km) of the total length of the highway bridge. Thus, the PSCB girder bridge can be one of the bridge types where maintenance is important. In order to analyze the damage types of PSCB girder bridges, a detailed analysis was conducted by selecting 62 places (477 spans) precision safety diagnosis reports considering ratio of the construction method and snow removal environment exposure class. Analysis of report and a field investigation was conducted, and as a result, most of the causes of deterioration damage were caused by rainwater (salt water) flowing into the bridge pavement soaking in between the top flange and the interface. After concrete slab deteriorate occurred then bridge pavement cracking and breaking increased and exfoliation of concrete occurred by corrosion and expansion of the reinforcing bars occurred. In addition, the cause of cracks in the longitudinal direction on the bottom of the top flange is considered to be cracks caused by restrained drying shrinkage. In conclusion, for reasonable maintenance considering the characteristics of PSCB girder bridges, it should be suggested in the design aspect that restrained drying shrinkage crack on top flange. Also, it is believed that differentiated maintenance method should be proposed according to snow removal environment exposure class.

Prediction of Crack Distribution for the Deck and Girder of Single-Span and Multi-Span PSC-I Bridges (단경간 및 다경간 PSC-I 교량의 바닥판 및 거더의 균열분포 예측)

  • Hyun-Jin Jung;Hyojoon An;Jaehwan Kim;Kitae Park;Jong-Han Lee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.6
    • /
    • pp.102-110
    • /
    • 2023
  • PSC-I girder bridges constitute the largest proportion among highway bridges in Korea. According to the precision safety diagnosis data for the past 10 years, approximately 41.3% of the PSC-I bridges have been graded as C. Furthermore, with the increase in the aging of bridges, preemptive management is becoming more important. Damage and deterioration to the deck and girder with a long replacement cylce can have considerable impacts on the service and deterioration of a bridge. In addition, the high rate of device damages, including expansion joints and bearings, necessitates an investigation into the influence of the device damage in the structural members of the bridge. Therefore, this study defined representative PSC-I girder bridges with single and multiple spans to evaluate heterogeneous damages that incorporate the damage of the bridge member and device with the deterioration of the deck. The heterogeneous damages increased a crack area ratio compared to the individual single damage. For the single-span bridge, the occurrence of bearing damage leads to the spread of crack distribution in the girder, and in the case of multi-span bridges, expansion joint damage leads to the spread of crack distribution in the deck. The research underscores that bridge devices, when damaged, can cause subsequent secondary damage due to improper repair and replacement, which emphasizes the need for continuous observation and responsive action to the damages of the main devices.

Tracking the History of the Three-story Stone Pagoda from the Goseonsa Temple Site in Gyeongju throughan Analysis of Component (부재 해석을 통한 경주 고선사지 삼층석탑의 연혁 추적)

  • Jeon, Hyo Soo
    • Conservation Science in Museum
    • /
    • v.21
    • /
    • pp.41-52
    • /
    • 2019
  • The findings of a 2017 safety inspection of the Three-story Pagoda from the Goseonsa Temple site in Gyeongju suggested the possibility that the stone for the second story of the pagoda may have been rotated after the pagoda was disassembled for removal from its original site in 1975. The materials from the pagoda were investigated using photographs and other relevant data from both the Japanese colonial period and from around 1975. The analysis found that the materials of the pagoda were not changed after analleged reconstruction in 1943, but that during the process of relocating the pagoda in 1975 the body of the second story was indeed rotated counter clockwise by 90 degrees and one of the four stone elements making up the first-story roof was exchanged with a part from the second-story roof. In order to discover whether the materials had been incorrectly placed, each part of the pagoda was precisely measured and the elements of the roofs were virtually reconstructed using 3D scanning data. The investigation did not find any singularities with in the components of each roof; the four part sof the first-story roof were 75 to 76 centimeters thick and those for the second-story roof were 78 to 79 centimeters thick. The connections between each part of the roofs also appeared natural. This seems to indicate that there was indeed an undocumented repair of the pagoda at some point between its creation and 1943 and an error that took place during this repair was corrected in 1975. In addition, the study suggested a possibility that the body of the second story was rotated counter clockwised to a change in the locations of parts of the two roofs.

Image-Data-Acquisition and Data-Structuring Methods for Tunnel Structure Safety Inspection (터널 구조물 안전점검을 위한 이미지 데이터 취득 및 데이터 구조화 방법)

  • Sung, Hyun-Suk;Koh, Joon-Sub
    • Journal of the Korean Geotechnical Society
    • /
    • v.40 no.1
    • /
    • pp.15-28
    • /
    • 2024
  • This paper proposes a method to acquire image data inside tunnel structures and a method to structure the acquired image data. By improving the conditions by which image data are acquired inside the tunnel structure, high-quality image data can be obtained from area type tunnel scanning. To improve the data acquisition conditions, a longitudinal rail of the tunnel can be installed on the tunnel ceiling, and image data of the entire tunnel structure can be acquired by moving the installed rail. This study identified 0.5 mm cracked simulation lines under a distance condition of 20 m at resolutions of 3,840 × 2,160 and 720 × 480 pixels. In addition, the proposed image-data-structuring method could acquire image data in image tile units. Here, the image data of the tunnel can be structured by substituting the application factors (resolution of the acquired image and the tunnel size) into a relationship equation. In an experiment, the image data of a tunnel with a length of 1,000 m and a width of 20 m were obtained with a minimum overlap rate of 0.02% to 8.36% depending on resolution and precision, and the size of the local coordinate system was found to be (14 × 15) to (36 × 34) pixels.