• 제목/요약/키워드: precast r.c. structure

검색결과 5건 처리시간 0.013초

Seismic design of a precast r.c. structure equipped with viscous dampers

  • Silvestri, Stefano;Gasparini, Giada;Trombetti, Tomaso
    • Earthquakes and Structures
    • /
    • 제2권3호
    • /
    • pp.297-321
    • /
    • 2011
  • The seismic design of a two-storey precast reinforced-concrete building structure equipped with viscous dampers is presented in this paper with twofold purpose. The first goal is to verify the applicability of a practical procedure for the identification of the mechanical characteristics of the viscous dampers which allow to achieve target performance levels, originally proposed by the authors for moment-resisting building frames, also with reference to "pendular" structures. The second goal is to investigate the effectiveness of the use of viscous dampers (as compared with traditional lateral-resisting stiff braces) for the seismic design of precast not moment-resisting concrete structures.

Performance evaluation of a seismic retrofitted R.C. precast industrial building

  • Nastri, Elide;Vergato, Mariacristina;Latour, Massimo
    • Earthquakes and Structures
    • /
    • 제12권1호
    • /
    • pp.13-21
    • /
    • 2017
  • Recent seismic events occurred in Italy (Emilia-Romagna 2012, Abruzzo 2009) and worldwide (New Zealand 2010 and 2011) highlighted some of the weaknesses of precast concrete industrial buildings, especially those related to the connecting systems traditionally employed to fasten the cladding panels to the internal framing. In fact, one of the most commons fails it is possible to observe in such structural typologies is related to the out-of-plane collapse of the external walls due to the unsatisfactory behaviour of the connectors used to join the panels to the perimeter beams. In this work, the strengthening of a traditional industrial building, assumed as a case study, made by precast reinforced concrete is proposed by the adoption of a dual system allowing the reinforcement of the structure by acting both internally; by pendular columns and, externally, on the walls. In particular, traditional connections at the top of the walls are substituted by devices able to work as a slider with vertical axis while, the bottom of the walls is equipped with two or more hysteretic dampers working on the uplift of the cladding panels occurring under seismic actions. By means of this approach, the structure is stiffened; obtaining a reduction of the lateral drifts under serviceability limit states. In addition, its seismic behaviour is improved due to the additional source of energy dissipation represented by the dampers located at the base of the walls. The effectiveness of the suggested retrofitting approach has been checked by comparing the performance of the retrofitted structure with those of the structure unreinforced by means of both pushover and Incremental Dynamic Analyses (IDA) in terms of behaviour factor, assumed as a measure of the ductility capacity of the structure.

1/3축소 3층 삼환까뮤 P.C 모델의 진동대 실험 (Shaking Table Test of 1/3-Scale 3-Story Sam-Hwan Camus Precast Concrete Model)

  • 이한선
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1992년도 가을 학술발표회 논문집
    • /
    • pp.140-154
    • /
    • 1992
  • The objective of the research stated here was aimed at providing the information needed to establish the Korean Seismic Design Code Recommendations and Guides for precast concrete (P.C) large panel apartment buildings. This was accomplished by investigation and analysis of the response of P.C large panel structures subjected to shaking table excitation simulating earthquake ground motion. one of the test specimens used was 1/3-scaled 3-story box P.C model provided by Sam-Hwan Camus Corporation. The 4m $\times$4m shaking table was used to simulate the earthquake ground motion. the employed input accelerogram was the one recorded as Taft N21E component and the peak ground acceleration(PGA) was scaled depending on the desired level of seismic severity and the time according to dynamic similitude rule. Based on results obtained from shaking table test of this P.C model, the following conclusions were drawn . (1) As far as test specimen is concerned, the seismic safety factors turns out to be 7~8. (2)P.C model has damping ratio of about8% which is twice larger than in-situ R.C. structure. And (3)this model has global displacement ductility ratio of 2~3 through the energy dissipation by opening and sliding of joints.

  • PDF

PC 구조물 부재간 접합부에 적용되는 실링재의 수밀성 평가방안 마련을 위한 기초적 연구 (A Basic Study to Prepare a Watertightness Evaluation Plan for Sealant Applied to Joints Between Members of PC Structures)

  • 김태호;김용로;고효진;박진상;김동범;이상욱
    • 한국건축시공학회지
    • /
    • 제23권1호
    • /
    • pp.45-56
    • /
    • 2023
  • 본 연구는 PC공법에 적용되는 실링재를 대상으로 수밀성 측면의 내구성 평가방안 마련의 타당성을 검토하기 위하여 진행하였다. 이를 위해 관련 KS표준의 품질기준에 동일하게 만족하는 실링재 5종을 선정하여 시험을 진행하였으며, 시험결과 5종의 실링재 중 3개 실링재가 바탕면과의 탈락 및 균열 등 수밀성 저하를 나타냈으며, 2종의 경우 육안관찰 상 큰 변화는 없었으나, 추가분석을 통해 소재의 응력 저하율의 차이가 크게 발생하는 것을 확인할 수 있었다. 이에 상기 결과를 근거로 향후 실링재 간 수밀성 측면의 성능검토 필요성을 확인하였으며, 이를 기반하여 제품 선정 시 활용 가능한 수밀성 평가방안의 타당성을 정량적으로 확인하였다.

마이크로파일로 보강된 프리캐스트 콘크리트 옹벽의 최적보강형태에 관한 연구 (A Study on Optimal Reinforcing Type of Precast Retaining Wall Reinforced by Micropiles)

  • 김홍택;박준용;유찬호
    • 한국지반공학회논문집
    • /
    • 제22권11호
    • /
    • pp.89-99
    • /
    • 2006
  • 프리캐스트 콘크리트 옹벽은 현장타설 콘크리트 옹벽에 비해 공기 단축효과, 품질의 우수성, 교통 및 인접구조물과의 간섭 최소화 등 많은 장점을 가지고 있다. 하지만 지반조건이 비교적 양호한 직접기초형태의 경우에는 별도의 보강조치를 고려하지 않으면 자중만으로 저항하게 됨에 따라 옹벽의 단면이 증가하게 되고 그에 따른 운반상의 어려움 및 공사비 증가 등의 단점이 있다. 본 연구에서는 이러한 문제점을 보완하기 위한 방법으로 마이크로파일공법의 적용성을 평가해 보았다. 마이크로파일공법은 소형장비로 시공이 가능하므로 작업공간의 제약이 없고, 저비용 및 고효율의 장점을 가지고 있으나 보강효과를 높이기 위해 설치한 마이크로파일의 역학적 거동특성이 명확히 규명되지 않은 상태이며, 마이크로파일의 길이, 직경, 설치각도 및 설치위치 등에 대한 설치기준이 없고 경험에 의존하고 있는 실정이다. 따라서 본 연구에서는 프리캐스트 콘크리트 옹벽에 보강된 마이크로파일의 최적보강형태 및 보강효과를 규명 제시하기 위하여 활동 및 전도거동에 대한 실내모형실험을 각각 시행하였다. 또한 실내모형실험 결과를 토대로 제시된 마이크로파일의 최적보강형태를 검증하기 위한 목적으로 유한요소해석 및 한계평형해석 등의 수치해석을 수행하여 마이크로파일의 최적 보강형태를 제시하였다. 실내모형실험과 수치해석으로 프리캐스트 콘크리트 옹벽에 보강되는 마이크로파일의 최적보강형태를 평가한 결과, 마이크로파일은 옹벽높이의 0.4배 저판길이의 0.04배 일 때가, 최적의 보강효율을 보이는 것으로 평가되었다.