• 제목/요약/키워드: precast panel

검색결과 143건 처리시간 0.03초

Development of analytical modeling for an energy-dissipating cladding panel

  • Maneetes, H.;Memari, A.M.
    • Structural Engineering and Mechanics
    • /
    • 제32권5호
    • /
    • pp.587-608
    • /
    • 2009
  • Modern earthquake-resistant design aims to isolate architectural precast concrete panels from the structural system so as to reduce the interaction with the supporting structure and hence minimize damage. The present study seeks to maximize the cladding-structure interaction by developing an energy-dissipating cladding system (EDCS) that is capable of functioning both as a structural brace, as well as a source of energy dissipation. The EDCS is designed to provide added stiffness and damping to buildings with steel moment resisting frames with the goal of favorably modifying the building response to earthquake-induced forces without demanding any inelastic action and ductility from the basic lateral force resisting system. Because many modern building facades typically have continuous and large openings on top of the precast cladding panels at each floor level for window system, the present study focuses on spandrel type precast concrete cladding panel. The preliminary design of the EDCS was based on existing guidelines and research data on architectural precast concrete cladding and supplemental energy dissipation devices. For the component-level study, the preliminary design was validated and further refined based on the results of nonlinear finite element analyses. The stiffness and strength characteristics of the EDCS were established from a series of nonlinear finite element analyses and are discussed in detail in this paper.

전단키를 갖는 프리캐스트 콘크리트 패널 수직접합부의 전단강도 (Shear Strength of Vertical Joints in Precast Concrete Panel with Shear Key)

  • 이상섭;박금성;배규웅
    • 대한건축학회논문집:구조계
    • /
    • 제35권9호
    • /
    • pp.151-158
    • /
    • 2019
  • A concrete core is used widely as lateral stability systems in high-rise modular buildings. As an alternative to traditional cast in-situ core, the precast concrete(PC) method can accelerate the construction of reinforced concrete cores. A core composed of precast elements differs from a in-situ core in having connections between the precast elements. The typical vertical connection between PC panels is consisted of shear keys, loop bars, lacer bars and grout. In this study, the effect of vertical connection components on shear strength is investigated experimentally. The test results show that the contribution to the shear strength is greater in order of grout strength, shear keys, lacer bars and loop bars. In addition, the numerical models to estimate the shear strength according to two crack patterns in the vertical joint of the PC panels are derived. The feasibility of the numerical models is evaluated by comparing the estimated shear strength and the test results.

A new precast wall connection subjected to monotonic loading

  • Vaghei, Ramin;Hejazi, Farzad;Taheri, Hafez;Jaafar, Mohd Saleh;Ali, Abang Abdullah Abang
    • Computers and Concrete
    • /
    • 제17권1호
    • /
    • pp.1-27
    • /
    • 2016
  • Final construction project cost is significantly determined by construction rate. The Industrialized Building System (IBS) was promoted to enhance the importance of prefabrication technology rather than conventional methods in construction. Ensuring the stability of a building constructed by using IBS is a challenging issue. Accordingly, the connections in a prefabricated building have a basic, natural, and essential role in providing the best continuity among the members of the building. Deficiencies of conventional precast connections were observed when precast buildings experience a large induced load, such as earthquakes and other disasters. Thus, researchers aim to determine the behavior of precast concrete structure with a specific type of connection. To clarify this problem, this study investigates the capacity behavior of precast concrete panel connections for industrial buildings with a new type of precast wall-to-wall connection (i.e., U-shaped steel channel connection). This capacity behavior is compared with the capacity behavior of precast concrete panel connections for industrial buildings that used a common approach (i.e., loop connection), which is subjected to monotonic loading as in-plane and out-of-plane loading by developing a finite element model. The principal stress distribution, deformation of concrete panels and welded wire mesh (BRC) reinforcements, plastic strain trend in the concrete panels and connections, and crack propagations are investigated for the aforementioned connection. Pushover analysis revealed that loop connections have significant defects in terms of strength for in-plane and out-of-plane loads at three translational degrees of freedom compared with the U-shaped steel channel connection.

반단면 프리캐스트 패널을 적용한 RC 슬래브의 내화성능 평가 (Evaluation of Fire Performance of RC Slabs with Half-Depth Precast Panels)

  • 정철헌;임초롱;김현준;주상훈
    • 대한토목학회논문집
    • /
    • 제30권4A호
    • /
    • pp.391-398
    • /
    • 2010
  • 본 연구에서는 반단면 프리캐스트 패널을 갖는 RC 슬래브에 대해서 비재하 상태에서 ISO-834 화재곡선을 적용한 가열시험을 수행하였다. 가열시험시 PP섬유 혼입되지 않은 실험체에서는 콘크리트의 폭렬이 발생되고, PP섬유가 혼입된 실험체에서는 폭렬이 발생되지 않았다. PP섬유가 혼입된 반단면 프리캐스트 패널을 적용한 RC 슬래브의 발생온도는 PP섬유가 혼입되지 않은 경우보다 낮은 수준을 보였다. 화재 가열실험 후 상온상태로 냉각된 RC 슬래브의 극한하중을 평가하기 위하여 3점 휨실험을 수행하였다. 실험결과, PP섬유가 혼입되지 않은 RC 슬래브는 PP섬유가 혼입된 실험체와 비교해 약 32.5% 정도 극한하중이 감소하는 결과를 보였다. 또한, PP섬유가 혼입된 반단면 프리캐스트 패널을 갖는 RC 슬래브의 극한하중은 PP섬유가 혼입된 전두께 RC 슬래브보다 큰 수준을 보였다. 이상의 결과에서 PP섬유의 혼입과 반단면 프리캐스트 패널 적용시 화재에 대한 저항능력이 향상됨을 확인하였다.

프리캐스트 콘크리트 대형 패널을 이용한 조립식 아파트 공사 (Prefabricated Apartments Project Using Precast Concrete Large Panel System)

  • 박의식
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1989년도 가을 학술발표회 논문집
    • /
    • pp.49-52
    • /
    • 1989
  • This report introduces the large scale prefabricated apartment project in Saudi Arabia designed and built by Hyundai Engineering and construction Co. as turn-key basis from ministry of Public works and ltousing of Saudi Arabia. This project using precast large panel system is 7,600 dwelling unit, total building area 1.8 mil sguare meters. Large panel system is a kind of industrialized building method which classified as monolithic system, total system and structural system. Hyundai Engineering and Construction Co. develop his own prefabricated large panel system for this project and named "HYUNDAI SYSTEM". The key point of this system is vertical and horizontal joints between panels. Also stability of whole building structure is especially important for this kind of prefabricated building. building.

  • PDF

수평접합부의 비탄성 특성을 고려한 프리캐스트 대형판넬 구조물의 비선형 해석에 관한 연구 (Nonlinear Analysis of Precast Large Panel Structures Considering the Inelastic Properties of Horizontal Joints)

  • 정일영;최완철;송진규;강해관
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1995년도 봄 학술발표회 논문집
    • /
    • pp.45-52
    • /
    • 1995
  • The stability and integrity of precast large panel structures are analyzed with nonlinear mathematical model considering the inelastic properties of horizontal joints. In this research, an analysis for cyclic loading test was carried out by the macro model that idealized the horizontal joints as inelastic-nonlinear spring systems. As a results, the strain hardening ratio of shear slip element was estimated as about 0.05%- 0.2% of initial shear stiffness. And under lateral load, the rocking motion due ti overturning moment was dominant rather than shear slip motion in the behavior of precast structures.

  • PDF

PSC보의 박스화 보강방법의 신뢰성해석 (A Reliability Analysis on the To-Box Reinforcement Method of PSC Beam Bridges)

  • 방명석
    • 한국안전학회지
    • /
    • 제21권3호
    • /
    • pp.94-100
    • /
    • 2006
  • The goal of this study is to show the way to increase the safety of deteriorated PSC beam bridges by the to-box reinforcing method. This method is to change the open girder section into the closed box section by connecting bottom flanges of neighboring PSC girders with the precast panels embedding PS tendons at the anchor block. The box section is composed of three concrete members with different casting ages, RC slab, PSC beam, precast panel. This different aging requires a time-dependent analysis considering construction sequences. Reliability index and failure probability are produced by the AFOSM reliability analysis. Transversely five schemes and longitudinally two schemes are considered. The full reinforcing scheme, transversely and longitudinally, shows the highest reliability index, but it requires more cost for retrofit. The partial reinforcing scheme 4, 4-1 are recommended in this study as the economically best scheme.

콘크리트 슬래브 궤도의 3차원 거동해석 (3- D Analysis of Concrete Slab Track System)

  • 김정일;장승엽
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 춘계학술대회 논문집
    • /
    • pp.955-960
    • /
    • 2004
  • In this study, three dimensional FE analysis of concrete slab track has been performed in order to develop the realistic design of precast concrete slab track. The precast slab track system including the precast concrete slab panel and the grout layer is modeled using the three dimensional solid element with crack softening effect. The input load is computed from the one dimensional beam element model constituting the rail and several discrete springs. To investigate the effect of the longitudinal connection of slab panels, two different systems-continuous and discrete systems - are modeled. The analytical results show that the stresses of both the slab panel and the grout layer are in the range of linear elastic, and, at the interface between two adjacent panels, the primary stresses of the grout layer of the discrete system are higher than those of the continuous system. However, The overall stress levels of the grout layer are very low relative to the strength of th grout.

  • PDF

P.C. 대형판 구조물의 수평접합부 유효강성에 대한 정량적 분석 (Quantitative Analysis on Effective Stiffness of Horizontal Joints in Precast Concrete Large Panel Structures)

  • 이한선;장극관;신영식
    • 콘크리트학회지
    • /
    • 제6권3호
    • /
    • pp.142-151
    • /
    • 1994
  • 프리캐스트 콘크리트 대형판 구조물에 있어서 접합부의 강성은 일반적으로 일체식 철근 콘클리트 벽식구조물에 비하여 떨어지는 것으로 알려져있으나 이들 강성에 대한 정량적인 값에 대한 정보가 매우 부족한 실정이다. 이 논문은 몇가지 실험으로부터 도출된 해석적 결과에 근거하여 특히 수평접합부의 압축강도에 관한 정량적 정보를 제공하는 것을 목적으로 한다. 또한 접촉문제로부터의 접근에 의해 구해진 수평접합부의 압축강성값이 위에서 얻은 값들과 매우 유사함을 보여주고 있다.

U형 프리캐스트 콘크리트 벽패널로 채운 기존 철근 콘크리트 보-기둥 구조물의 전단 거동 분석 (Analysis on the Shear Behavior of Existing Reinforced Concrete Beam-Column Structures Infilled with U-Type Precast Wall Panel)

  • 하수경;손국원;유승룡;주호성
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제19권6호
    • /
    • pp.18-28
    • /
    • 2015
  • 이 연구의 목표는 학교 건물과 같은 저층 보-기둥 철근콘크리트 구조 건물에서 프리캐스트 벽패널을 사용한 새로운 내진보강 방법을 개발하는데 있다. 1개의 무 보강 보-기둥 실험체와 U형 PC 패널로 보강한 2개의 보강 보-기둥 실험체에 대한 정적 이력 하중실험을 진행하였다. 앵커 접합부 실험체는 전단 파괴될 것으로 해석되었고 철판 용접 접합부 실험체는 휨 파괴할 것으로 예측되었다. 실험체의 종국 내력은 상부 접합부의 전단 내력과 PC 패널 절곡 부 휨 위험단면에서 휨 내력 중 약한 것으로 결정되었다. 이 실험체에서, 한쪽 RC기둥이 가 하중(미는 실험 하중)을 받아 PC 패널 부재를 밀게 된다면, 다른 쪽 내부 수직부재는 상부 전단 접합부로부터 부 하중(당기는 실험 하중)을 받게 되어있었다. 가 하중을 받는 2개의 부재는 합성 휨 거동이 지배적이므로 합성단면의 휨 내력이 실험체의 최종 내력을 결정하게 되지만, 이 경우 최종 내력에 대하여 상부 전단 접합부 강도의 직접적인 영향은 없다고 볼 수 있다. 그러나 부 하중(당기는 하중)을 받는 RC 기둥과 PC 패널 부재는 비합성 거동이 지배적이고 실험체의 최종 내력은 상부 전단 접합부 전단내력의 크기에서 직접 영향을 받는 것으로 파악되었다. ACI 318M-11 Appendix-D 앵커 전단설계에 기초한 전단내력 그리고 실험에서 얻은 최대하중을 적용하여 마이다스 젠 탄성설계에 의하여 계산한 전단 외력에 대한 비교 해석결과는 실험결과와 일치하는 해석결과를 보여주었다.