• 제목/요약/키워드: precast concrete panel

검색결과 125건 처리시간 0.038초

Simulation of cyclic response of precast concrete beam-column joints

  • Adibi, Mahdi;Talebkhah, Roozbeh;Yahyaabadi, Aliakbar
    • Computers and Concrete
    • /
    • 제24권3호
    • /
    • pp.223-236
    • /
    • 2019
  • Experience of previous earthquakes shows that a considerable portion of concrete precast buildings sustain relatively large damages especially at the beam-column joints where the damages are mostly caused by bar slippage. Precast concrete buildings have a kind of discontinuity in their beam-column joints, so reinforcement details in this area is too important and have a significant effect on the seismic behavior of these structures. In this study, a relatively simple and efficient nonlinear model is proposed to simulate pre- and post-elastic behavior of the joints in usual practice of precast concrete building. In this model, beam and column components are represented by linear elastic elements, dimensions of the joint panel are defined by rigid elements, and effect of slip is taken into account by a nonlinear rotational spring at the end of the beam. The proposed method is validated by experimental results for both internal and external joints. In addition, the seismic behavior of the precast building damaged during Bojnord earthquake 13 May 2017, is investigated by using the proposed model for the beam-column joints. Damage unexpectedly inducing the precast building in the moderate Bojnord earthquake may confirm that bearing capacity of the precast building was underestimated without consideration of joint behavior effect.

고성능 섬유쉬트를 부착시킨 경량 프리캐스트 복합패널로 보강된 RC보의 휨거동 (Flexural Behaviors of RC Beams Strengthened by Light Concrete Precast Composite Panel with an Advanced Fiber Sheet)

  • 안상호;윤정배
    • 콘크리트학회논문집
    • /
    • 제14권4호
    • /
    • pp.483-491
    • /
    • 2002
  • 본 연구는 경량 콘크리트 프리캐스트 패널에 고성능 섬유쉬트를 접착시킨 복합패널로 철근 콘크리트 보 하부에 휨 보강하여 보강보의 구조적 성능을 분석하였다. 보강보의 구조적 고찰은 항복하중, 최대하중, 각 하중에서 처짐 그리고 휨강성과 연성을 비교 분석하였다. 그 결과 39개 보를 실험하여 복합패널로 보강한 경우에 휨강도가 균일되게 향상됨을 보였다. 또한 실험결과 복합패널로 보강한 철근 콘크리트 보는 구조적으로 우수한 특성을 보였고, 섬유쉬트 부착공법으로 보강된 보와 비교할 경우에도 보강보의 강도가 더 개선되는 것으로 나타났다.

프리캐스트 콘크리트 벽체의 상하부에 C형강 보가 결합된 복합 패널의 개발 (Development of Hybrid Panel with C-shaped Steel Beam at Top and Bottom of Precast Concrete Wall)

  • 이상섭;박금성
    • 한국강구조학회 논문집
    • /
    • 제29권6호
    • /
    • pp.435-442
    • /
    • 2017
  • 모듈러 건축물을 중고층화하기 위해 횡력저항시스템은 반드시 필요한 구조 요소로 10~20층 규모에서 콘크리트 코어는 가장 전형적인 횡력저항시스템으로 알려져 있다. 습식 공법인 콘크리트 코어 공사는 모듈의 오염과 파손 가능성으로 모듈 적층과의 동시 작업이 곤란하다. 이에 모듈 적층과 콘크리트 코어의 동시 시공이 가능한 복합 PC 패널 공법을 개발하였다. 복합 PC 패널은 일정 간격을 두고 웨브가 마주보는 한 쌍의 C형강을 콘크리트 벽체의 상부와 하부에 결합한 구조 부재로 볼트로 접합하여 적층하는 건식 공법으로 콘크리트 코어를 구축할 수 있다. 이 연구에서는 복합 PC 패널이 콘크리트 벽체와 동등한 성능을 갖도록 해석을 통해 상세 개선 과정을 제시하였다.

윤하중 시험 차량을 활용한 프리캐스트 콘크리트 바닥판의 거동 특성 (Behavioral Characteristics of Precast Concrete Slab using Wheel Load Tester)

  • 박석순;김낙석
    • 한국방재학회 논문집
    • /
    • 제10권1호
    • /
    • pp.29-34
    • /
    • 2010
  • 본 연구에서는 차량의 주행으로 인한 동적하중이 프리캐스트 바닥판의 손상에 미치는 영향에 대하여 살펴보았다. 실제 주행조건에 근접한 윤하중 시험차량 및 프리캐스트 바닥판을 제작하였으며, 정적재하시험 및 반복 윤하중 시험을 통하여 패널의 접합부, 시험시편의 처짐량, 베딩 층, 전단 포켓부의 거동을 분석하였다. 프리캐스트 바닥판 패널-1, 패널-2, 패널-3을 연결, 정적재하시험과 윤하중 재하시험 결과를 분석하면 변형률과 처짐의 경우 최대값에는 큰 차이가 없으나 정적재하시험은 패널-2에서 처짐이 가장 크게 발생한 반면, 윤하중 재하시험은 변형률이 전단 포켓부에서 가장 많이 발생하였으며, 중앙부 패널-2에서보다 패널-1과 패널-3에서 최대 처짐이 발생하는 차이를 보였다.

Free vibrations of precast modular steel-concrete composite railway track slabs

  • Kimani, Stephen Kimindiri;Kaewunruen, Sakdirat
    • Steel and Composite Structures
    • /
    • 제24권1호
    • /
    • pp.113-128
    • /
    • 2017
  • This paper highlights a study undertaken on the free vibration of a precast steel-concrete composite slab panel for track support. The steel-concrete composite slab track is an evolvement from the slab track, a form of ballastless track which is becoming increasingly attractive to asset owners as they seek to reduce lifecycle costs and deal with increasing rail traffic speeds. The slender nature of the slab panel due to its reduced depth of construction makes it susceptible to vibration problems. The aim of the study is driven by the need to address the limited research available to date on the dynamic behaviour of steel-concrete composite slab panels for track support. Free vibration analysis of the track slab has been carried out using ABAQUS. Both eigenfrequencies and eigenmodes have been extracted using the Lanczos method. The fundamental natural frequencies of the slab panel have been identified together with corresponding mode shapes. To investigate the sensitivity of the natural frequencies and mode shapes, parametric studies have been established, considering concrete strength and mass and steel's modulus of elasticity. This study is the world first to observe crossover phenomena that result in the inversion of the natural orders without interaction. It also reveals that replacement of the steel with aluminium or carbon fibre sheeting can only marginally reduce the natural frequencies of the slab panel.

Damped frequencies of precast modular steel-concrete composite railway track slabs

  • Kaewunruen, Sakdirat;Kimani, Stephen Kimindiri
    • Steel and Composite Structures
    • /
    • 제25권4호
    • /
    • pp.427-442
    • /
    • 2017
  • This paper presents unprecedented damped oscillation behaviours of a precast steel-concrete composite slab panel for track support. The steel-concrete composite slab track is an innovative slab track, a form of ballastless track which is becoming increasingly attractive to asset owners as they seek to reduce lifecycle costs and deal with increasing rail traffic speeds. The slender nature of the slab panel due to its reduced depth of construction makes it susceptible to vibration problems. The aim of the study is driven by the need to address the limited research available to date on the dynamic behaviour of steel-concrete composite slab panels for track support. Free vibration analysis of the track slab has been carried out using ABAQUS. Both undamped and damped eigenfrequencies and eigenmodes have been extracted using the Lancsoz method. The fundamental natural frequencies of the slab panel have been identified together with corresponding mode shapes. To investigate the sensitivity of the natural frequencies and mode shapes, parametric studies have been established, considering concrete strength and mass and steel's modulus of elasticity. This study is the world first to observe crossover phenomena that result in the inversion of the natural orders without interaction. It also reveals that replacement of the steel with aluminium or carbon fibre sheeting can only marginally reduce the natural frequencies of the slab panel.

프리캐스트 콘크리트 대형 패널을 이용한 조립식 아파트 공사 (Prefabricated Apartments Project Using Precast Concrete Large Panel System)

  • 박의식
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1989년도 가을 학술발표회 논문집
    • /
    • pp.49-52
    • /
    • 1989
  • This report introduces the large scale prefabricated apartment project in Saudi Arabia designed and built by Hyundai Engineering and construction Co. as turn-key basis from ministry of Public works and ltousing of Saudi Arabia. This project using precast large panel system is 7,600 dwelling unit, total building area 1.8 mil sguare meters. Large panel system is a kind of industrialized building method which classified as monolithic system, total system and structural system. Hyundai Engineering and Construction Co. develop his own prefabricated large panel system for this project and named "HYUNDAI SYSTEM". The key point of this system is vertical and horizontal joints between panels. Also stability of whole building structure is especially important for this kind of prefabricated building. building.

  • PDF

대형판 프리캐스트 콘크리트 구조 수평접합부의 전단내력에 대한 실험적 연구 (An Experimental Study on the Shear Resistance of Horizontal Joints in Precast Concrete Large Panel Structures)

  • 정창용;현원창;엄철환;어양석;김상식
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1992년도 가을 학술발표회 논문집
    • /
    • pp.208-213
    • /
    • 1992
  • This research is related to the experimental verification of the shear resistance of horizontal joint in precast concrete large panel structures. a total of 9 spicemens was tested to assess their shear resistance. In the tests lateral forces have been applied to the specimen to cause shear failure while keeping the axial compression consistantly. The shear resistances of the specimens have been evaluated by investigating the deformations and failure modes of the specimens. From the test results, it is observed that the shear resistance of the horizontal joints of P.C panel structures are closely connected with shear friction mechanism.

  • PDF

대형판 PC 구조 시스템의 수평접합부 충전부위 구조성능에 관한 실험연구 (Compressive Strength of Horizontal Joints Pocket in Precast Concrete Large Panel System)

  • 유성훈;조승호;박현수;어양석;정란
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 가을 학술발표회 논문집
    • /
    • pp.597-602
    • /
    • 1997
  • The compressive strength of horizontal joints in precast concrete large panel structures depends on parameters such as grout and panel strength, detail of joint, joint moment, width of grout column etc. As the panels are only connected at the pocket, it results in the reduction of compressive strength area. The purposes of this study are to develop the suitable grout material the joint pocket and to enable us to evaluate structural capacity. The validity of the design formulas provides us more economic system in construction. Test results of 15 specimens show that the proper construction procedure and grouting material develop the sufficient compressive strength of the wall as monolithic system.

  • PDF

프리캐스트 콘크리트 대형판 구조물의 1/5 축소모델 제작 및 실험기법 연구 (A Study on Manufacturing and Experimental Techniques for the 1/5th Scale Model of Precast Concrete Large Panel Structure)

  • 김상규;이한선
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1995년도 가을 학술발표회 논문집
    • /
    • pp.198-203
    • /
    • 1995
  • The objective of this study is to provide the information on the techniques of manufacturing and experiment in small scale modeling of precast concrete(P.C.)large panel structures. The adopted scale was 1/5th 4types of experiments were performed : material tests for model concrete and model reinforcement, compressive test of horizontal joint, shear test of vertical joint and cyclic static test of 2-story subassemblage structure. Based on the experimental results, the following conclusions are drawn: (1)Model concrete may have in general larger compressive strength than expected. (2) Model reinforcement can show less ductility if the annealing processes were performed without using vaccuum tube. (3) Failure modes of horizontal and vertical joints were almost same for both prototype and model. But the strength of model appears to be higher than required by similitude law. (4)Hysteretic behavior of 1/5 scale subassemblage model can be made quite similar to prototype's if the ductility of model reinforcement and compressive strength of model concrete could be representative of those of prototype.

  • PDF