• 제목/요약/키워드: pre-stressed structure

검색결과 36건 처리시간 0.018초

탄성지반상에 놓인 철근 콘크리트 축대칭 쉘의 정적 및 동적 해석(IV) -축대칭 쉘의 동적 응답에 대한 철근의 영향을 중심으로- (Static and Dynamic Analysis of Reinforced Concrete Axisymmetric Shell on the Elastic Foundation -Effect of Steel on the Dynamic Response-)

  • 조진구
    • 한국농공학회지
    • /
    • 제39권4호
    • /
    • pp.106-113
    • /
    • 1997
  • Dynamic loading of structures often causes excursions of stresses well into the inelastic range, and the influence of the geometric changes on the dynamic response is also significant in many cases. Therefore, both material and geometric nonlinearity effects should be considered in case that a dynamic load acts on the structure. A structure in a nuclear power plant is a structure of importance which puts emphasis on safety. A nuclear container is a pressure vessel subject to internal pressure and this structure is constructed by a reinforced concrete or a pre-stressed concrete. In this study, the material nonlinearity effect on the dynamic response is formulated by the elasto-viscoplastic model highly corresponding to the real behavior of the material. Also, the geometrically nonlinear behavior is taken into account using a total Lagrangian coordinate system, and the equilibrium equation of motion is numerically solved by a central difference scheme. The constitutive relation of concrete is modeled according to a Drucker-Prager yield criterion in compression. The reinforcing bars are modeled by a smeared layer at the location of reinforcements, and the steel layer model under Von Mises yield criteria is adopted to represent an elastic-plastic behavior. To investigate the dynamic response of a nuclear reinforced concrete containment structure, the steel-ratios of 0, 3, 5 and 10 percent, are considered. The results obtained from the analysis of an example were summarized as follows 1. As the steel-ratio increases, the amplitude and the period of the vertical displacements in apex of dome decreased. The Dynamic Magnification Factor(DMF) was some larger than that of the structure without steel. However, the regular trend was not found in the values of DMF. 2. The dynamic response of the vertical displacement and the radial displacement in the dome-wall junction were shown that the period of displacement in initial step decreased with the steel-ratio increases. Especially, the effect of the steel on the dynamic response of radial displacement disapeared almost. The values of DMF were 1.94, 2.5, 2.62 and 2.66, and the values increased with the steel-ratio. 3. The characteristics of the dynamic response of radial displacement in the mid-wall were similar to that of dome-wall junction. The values of DMF were 1.91, 2.11, 2.13 and 2.18, and the values increased with the steel-ratio. 4. The amplitude and the period of the hoop-stresses in the dome, the dome-wall junction, and the mid-wall were shown the decreased trend with the steel-ratio. The values of DMF were some larger than those of the structure without steel. However, the regular trend was not found in the values of DMF.

  • PDF

Research on prefabricated concrete beam-column joint with high strength bolt-end plate

  • Shufeng, Li;Di, Zhao;Qingning, Li;Huajing, Zhao;Jiaolei, Zhang;Dawei, Yuan
    • Structural Engineering and Mechanics
    • /
    • 제74권3호
    • /
    • pp.395-406
    • /
    • 2020
  • Many prefabricated concrete frame joints have been proposed, and most of them showed good seismic performance. However, there are still some limitations in the proposed fabricated joints. For example, for prefabricated prestressed concrete joints, prefabricated beams and prefabricated columns are assembled as a whole by the pre-stressed steel bar and steel strand in the beams, which brings some troubles to the construction, and the reinforcement in the core area of the joints is complex, and the mechanical mechanism is not clear. Based on the current research results, a new type of fabricated joint of prestressed concrete beams and confined concrete columns is proposed. To study the seismic performance of the joint, the quasi-static test is carried out. The test results show that the nodes exhibit good ductility and energy dissipation. According to the experimental fitting method and the "fixed point pointing" law, the resilience model of this kind of nodes is established, and compared with the experimental results, the two agree well, which can provides a certain reference for elasto-plastic seismic response analysis of this type of structure. Besides, based on the analysis of the factors affecting the shear capacity of the node core area, the formula of shear capacity of the core area of the node is proposed, and the theoretical values of the formula are consistent with the experimental value.

Impact of cable sag on the efficiency of an inertial mass damper in controlling stay cable vibrations

  • Wang, Zhi-hao;Gao, Hui;Xu, Yan-wei;Chen, Zheng-qing;Wang, Hao
    • Smart Structures and Systems
    • /
    • 제24권1호
    • /
    • pp.83-94
    • /
    • 2019
  • Passive negative stiffness dampers (NSDs) that possess superior energy dissipation abilities, have been proved to be more efficient than commonly adopted passive viscous dampers in controlling stay cable vibrations. Recently, inertial mass dampers (IMDs) have attracted extensive attentions since their properties are similar to NSDs. It has been theoretically predicted that superior supplemental damping can be generated for a taut cable with an IMD. This paper aims to theoretically investigate the impact of the cable sag on the efficiency of an IMD in controlling stay cable vibrations, and experimentally validate superior vibration mitigation performance of the IMD. Both the numerical and asymptotic solutions were obtained for an inclined sag cable with an IMD installed close to the cable end. Based on the asymptotic solution, the cable attainable maximum modal damping ratio and the corresponding optimal damping coefficient of the IMD were derived for a given inertial mass. An electromagnetic IMD (EIMD) with adjustable inertial mass was developed to investigate the effects of inertial mass and cable sag on the vibration mitigation performance of two model cables with different sags through series of first modal free vibration tests. The results show that the sag generally reduces the attainable first modal damping ratio of the cable with a passive viscous damper, while tends to increase the cable maximum attainable modal damping ratio provided by the IMD. The cable sag also decreases the optimum damping coefficient of the IMD when the inertial mass is less than its optimal value. The theoretically predicted first modal damping ratio of the cable with an IMD, taking into account the sag generally, agrees well with that identified from experimental results, while it will be significantly overestimated with a taut-cable model, especially for the cable with large sag.

복부 파형강판을 갖는 복합교량의 비틀림 거동에 대한 비선형 해석 모델 개발 (Development of Non-linear Analysis Model for Torsional Behavior of Composite Box-Girder with Corrugated Steel Webs)

  • 고희중;문지호;이학은
    • 대한토목학회논문집
    • /
    • 제31권3A호
    • /
    • pp.153-162
    • /
    • 2011
  • 복부 파형강판을 갖는 복합교량은 기존 PSC 박스 거더의 콘크리트 복부판을 파형강판으로 대체함으로써 상부구조의 경량화를 유도하고 프리스트레싱 효율성을 향상시킬 수 있어 국외에서 널리 이용되고 있다. 하지만 이러한 장점에도 불구하고 복부 파형강판을 갖는 복합교량은 기존 연구가 거더의 전단과 휨 거동에 국한되어 있어 비틀림 거동에 대한 이해는 부족한 상황이다. 국내외의 연구자들에 의하여 복부 파형강판을 갖는 복합교량의 비선형 해석 방법이 개발되었으나, 이러한 연구는 콘크리트의 인장 강도를 무시하여 균열 모멘트 및 비틀림 강성과 같은 콘크리트 교량의 사용성에 영향을 미치는 요소들에 대한 이해가 부족한 실정이다. 본 논문에서는 콘크리트의 인장 거동을 고려한 복부 파형강판을 갖는 복합교량의 비선형 비틀림 거동 해석 방법에 대한 연구를 수행하였다. 제안된 이론을 적용하여 해석 프로그램을 제작하였으며, 실험 연구를 통하여 개발된 해석 방법의 타당성을 검증하였다. 마지막으로 변수 해석을 실시하여 콘크리트의 인장 강도가 비틀림 거동에 미치는 영향을 분석하였다.

PSC Beam 교량의 설계단계 환경부하량 산정을 위한 공종 및 설계정보 특성 분석 (An Analysis of the Characteristics of Standard Work and Design Information on Estimating Environmental Loads of PSC Beam Bridge in the Design Phase)

  • 윤원건;하지광;김경주
    • 대한토목학회논문집
    • /
    • 제37권4호
    • /
    • pp.705-716
    • /
    • 2017
  • 산업화 시대를 지나며 많은 환경오염문제가 발생함에 따라, 친환경적이며 지속 가능한 발전을 위해 건설 산업계에도 환경성 평가 관련한 다양한 연구가 수행되고 있다. 그러나 설계단계 활용을 목적으로 토목시설물의 부위별 설계 대안에 대한 신속한 환경부하 산정 방법론은 부재하다. 이에 본 연구는 Pre-Stressed Concrete (PSC) beam교량을 대상으로 구조물 주요 부위별 표준단면을 이용한 환경부하 산정을 위한 선행연구로서, 설계초기 단계에서의 대표물량정보 기반 환경부하량을 효율적으로 산정할 수 있는 설계부위 및 공종정보 기준을 구축하는 것을 목표로 하였다. 이를 위해 25개 PSC Beam교량 사례에 대한 상세설계자료를 기반으로 ISO 14040의 전과정평가(Life Cycle Assessment, LCA) 수행절차를 통한 상세환경부하량 데이터베이스를 구축하였으며, 목적 및 범위는 교량의 자원제조 및 수송단계와 시공단계만으로 한정하였다. 또한, 환경부하발생에 영향이 높은 부위별 대표공종을 선정하여, 이러한 부위 및 공종분류에 따른 소요자원 및 8대 영향범주 별 환경부하량 특성분석을 수행하였다. 그 결과 교량의 특성상 상부공이 전체 42.91%의 환경부하량으로, 상부공중에서는 주요 자재인 레미콘이 53.13%, PSC beam공이 31.25%로 나타났다. 또한, 하부 교대 교각공에서는 주요 자재인 레미콘, 철근, 시멘트가 93%이상으로 대부분을 차지하였다. 향후 이러한 교량 부위별 대표공종 및 자재 정보들은 설계단계에서 구조물의 특성이 반영된 개략 환경부하량 모델 구축시 활용될 수 있을 것이다.

전기적 신호의 반사파 측정법을 적용한 부식 진단 기술의 개발 및 시뮬레이션 (Development and Simulation of a Detecting Method using Reflectometry of Electrical Signal)

  • 윤승현;방수식;신용준;임윤묵
    • 한국전산구조공학회논문집
    • /
    • 제31권6호
    • /
    • pp.367-372
    • /
    • 2018
  • 오래된 구조물의 내부 결함은 그 구조물의 안전에 큰 영향을 미친다. 따라서 안전에 문제가 생기기 전에 미리 검사를 진행하고 발견하는 것이 중요하다. 가장 쉽고 효율적인 방법은 육안으로 구조물을 진단하는 것이나, 프리스트레스트 콘크리트(PSC) 교량과 같은 구조물에서 부식이나 공극 같은 결함들은 피복으로 감싸져 있어 육안으로는 확인이 불가하다. 따라서 내부 결함도 진단할 수 있는 비파괴검사방법을 이용하여 진단해야 한다. 본 연구에서 사용되는 기술은 전력용 케이블을 진단할 때 주로 사용되는 시간 영역의 반사파 계측법과 시간-주파수 영역의 반사파를 적용하여 종단지점에 부착된 측정기계에서 인가한 신호가 이동하는 중 전기적 임피던스 변화에 의해 발생하는 반사파를 분석하는 기술로 측정시간 단축, 검사의 간편 성과 같은 측면에서 훨씬 큰 효율성을 가진다. 하지만 토목 구조물은 전력용 케이블과 달리 내부 구조가 복잡하여, 실제 진단을 진행하는데 어려움이 있기에 본 연구에서는 실제 실험과 COMSOL을 이용한 시뮬레이션의 결과를 확인 및 비교하여 시뮬레이션의 정확도와 적용가능성을 확인하였고, 반사파 계측법이 복잡한 구조물을 대상으로도 사용 가능한지 그 가능성 또한 보았다. 또한 더 나아가, 시뮬레이션을 통해 프리스트레스트 콘크리트(PSC) 교량의 덕트 내부에 공극 및 부식과 같은 결함이 생겼을 때, 그 결함들이 반사파에 미치는 영향을 보았다.