• Title/Summary/Keyword: pre-echo

Search Result 57, Processing Time 0.026 seconds

Convergence Analysis of Multiple Constrained Subband Affine Projection Algorithm (다중제한조건을 갖는 부밴드 AP 알고리즘의 수렴해석)

  • Kim, Young-Min;Sohn, Sang-Wook;Choi, Hun;Bae, Hyeon-Deok
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.474-476
    • /
    • 2009
  • In the radio communication, such as echo cancellation and channel equalization, adaptive filtering is very practical. Its convergence behavior that is used for updating the weights depends on the correlation of the input signal and length of adaptive filter. Highly correlated input and long length of adaptive filter deteriorate the convergence behavior. To solve this problem, recently, subband affine projection algorithm which pre-whiten the correlation of the input and update the weights in subband structure has been presented. This paper presents convergence analysis method of multiple constrained subband affine projection algorithm.

  • PDF

Artifacts Improvement by using the Echo Planar Imaging and Pre-Saturation Pulse Band techniques of Reduced Field-Of-View in Breast Magnetic Resonance Imaging Examination (유방 자기공명영상검사에서 감소된 영상영역의 에코평면영상기법과 사전포화기법 사용에 의한 인공물 개선)

  • Lee, Jaeheun;Kim, Hyunjin;Im, Inchul
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.5
    • /
    • pp.307-314
    • /
    • 2015
  • This study was conducted in reducing the involuntary motion artifacts because of lungs and heart movements as well as the aliasing artifacts generated during the use of the reduced-FOV EPI technique while performing breast MRI. Performed on a total of 38 obesity female subjects who visited the clinic for pre-examination before surgery within the period from August 1 to November 30, 2014. The 3.0T MRI scanner equipped with a breast scanning coil. Qualitative and quantitative analyses were each used for the evaluation of the acquired images while an Paired T-test and Wilcoxon rank test were performed to check the statistical significance. The variation ratio rose by 15.69% with the additional application of a pre-saturation pulse in the lesion, by 13.72% near the lesion, and 20.63% in the fat and the contrast-to-noise ratio rose by 10.58% in and near the lesion and by 12.03% in the lesion and fat, respectively. there were increases of 22.05% and 21.42% at 0 and 1000 respectively in qulitative evaluation and growth of 16.10% in apparent diffusion coefficient. it showed a statistically significant result(p<0.05) in signal to noise ratio, contrast to noise ratio, diffusion slope coefficient and apparent diffusion coefficient. The involuntary movements artifacts that occur in the phase encoding direction and the aliasing artifacts are considered to be reduced to obtain the best image in the additional use of the pre-saturation pulse as DWI is acquired.

Chemical Saturation Breath-hold Fast MR Imaging for characterization of Regional Fatty Changes in Liver (화학적 포화 호흡정지 급속 자기공명영상에서 국소적 간지방병변의 특성화)

  • 김동국;유정식;김태훈;오세정;김지형
    • Investigative Magnetic Resonance Imaging
    • /
    • v.1 no.1
    • /
    • pp.135-141
    • /
    • 1997
  • Purpose: To assess the usefulness of breath-hold fast MR imaging of liver with fat suppression (FS) by application of chemical saturation technique in the diagnosis of regional fatty changes suspected in sonography. Materials and Methods: Thirteen patients who had focal lesions with diffuse, homogeneous signal changes after FS through chemical saturation technique without additional changes of imaging parameter during MR imaging of liver were selected. T1-weighted fast low-angle shot and T2-weighted turbo spin-echo sequences were obtained with or without FS during each single breath-holding session. Subjective changes of signal intensity between the pre-FS and the FS images were compared with the sonographic findings in each lesion. Results: Seven lesions of decreased signal intensity after FS on T1 or T2-weighted images, including three lesions only at FS T1 images, were regarded as focal fat infiltration. All seven lesions had compatible sonographic findings as homogenously echogenic areas. Another six lesions of subjectively increased signal intensity including two lesions only at FS T2 images were regarded as focal fat sparing. All six lesions had sonographic findings as homogenous echo poor areas suggesting focal fat sparing. In cases regarded as fat infiltration, score changes were more prominent at FS T1 images than FS T2 images(p=0.0002). In cases regarded as fat sparing, score changes were more prominent at FS T2 images than FS T1 images(p=0.042). Conclusion: Breath-hold fast T1 and T2-weighted MR imaging with and without chemical saturation pre-pulse may be sufficient for characterization of regional fatty changes in the differential diagnosis of focal hepatic lesion found at sonography.

  • PDF

Phantom-Validated Reference Values of Myocardial Mapping and Extracellular Volume at 3T in Healthy Koreans

  • Lee, Eunjin;Kim, Pan Ki;Choi, Byoung Wook;Jung, Jung Im
    • Investigative Magnetic Resonance Imaging
    • /
    • v.24 no.3
    • /
    • pp.141-153
    • /
    • 2020
  • Purpose: Myocardial T1 and T2 relaxation times are affected by technical factors such as cardiovascular magnetic resonance platform/vendor. We aimed to validate T1 and T2 mapping sequences using a phantom; establish reference T1, T2, and extracellular volume (ECV) measurements using two sequences at 3T in normal Koreans; and compare the protocols and evaluate the differences from previously reported measurements. Materials and Methods: Eleven healthy subjects underwent cardiac magnetic resonance imaging (MRI) using 3T MRI equipment (Verio, Siemens, Erlangen, Germany). We did phantom validation before volunteer scanning: T1 mapping with modified look locker inversion recovery (MOLLI) with 5(3)3 and 4(1)3(1)2 sequences, and T2 mapping with gradient echo (GRE) and TrueFISP sequences. We did T1 and T2 mappings on the volunteers with the same sequences. ECV was also calculated with both sequences after gadolinium enhancement. Results: The phantom study showed no significant differences from the gold standard T1 and T2 values in either sequence. Pre-contrast T1 relaxation times of the 4(1)3(1)2 protocol was 1142.27 ± 36.64 ms and of the 5(3)3 was 1266.03 ± 32.86 ms on the volunteer study. T2 relaxation times of GRE were 40.09 ± 2.45 ms and T2 relaxation times of TrueFISP were 38.20 ± 1.64 ms in each. ECV calculation was 24.42% ± 2.41% and 26.11% ± 2.39% in the 4(1)3(1)2 and 5(3)3 protocols, respectively, and showed no differences at any segment or slice between the sequences. We also calculated ECV from the pre-enhancement T1 relaxation time of MOLLI 5(3)3 and the post-enhancement T1 relaxation time of MOLLI 4(1)3(1)2, with no significant differences between the combinations. Conclusion: Using phantom-validated sequences, we reported the normal myocardial T1, T2, and ECV reference values of healthy Koreans at 3T. There were no statistically significant differences between the sequences, although it has limited statistical value due to the small number of subjects studied. ECV showed no significant differences between calculations based on various pre- and post-mapping combinations.

Intelligent Architectural Design Module for Process Automation of Hanok Constructions (한옥 건축공정 자동화를 위한 지능형 설계모듈의 구현)

  • Ahn, Eun-Young
    • Journal of Korea Multimedia Society
    • /
    • v.15 no.9
    • /
    • pp.1156-1164
    • /
    • 2012
  • Hanok is a cultural heritage containing our ancestor's life style intact and breathing alive with us until now. As Hanok has been concerned as a echo-friendly architecture, a new methodology for efficient construction without damaging the traditional construction process comes into request. The goal of this research is development of a architectural design tool based on the BIM(Building Information Modeling) for satisfying these demands. It will be usable to support whole process of the traditional building from digital design to production and construction. Firstly, we take a consideration of the traditional architecture reflecting the spirit of the age and suggest efficient design method for architectural components. Each components is pre-fabricated as a template representing similar components. All pre-fabricated components are designed by object-oriented concepts so, many variations for a component can be derived from the pre-fabricated component. Our method is helpful for reducing design errors because that it considers combining rule between connecting components in the template design. Moreover it is plugged in the commercial architectural CAD, so it can supports digital design not only traditional architecture but also fusion style mixed with modern architecture.

Investigation of light stimulated mouse brain activation in high magnetic field fMRI using image segmentation methods

  • Kim, Wook;Woo, Sang-Keun;Kang, Joo Hyun;Lim, Sang Moo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.21 no.12
    • /
    • pp.11-18
    • /
    • 2016
  • Magnetic resonance image (MRI) is widely used in brain research field and medical image. Especially, non-invasive brain activation acquired image technique, which is functional magnetic resonance image (fMRI) is used in brain study. In this study, we investigate brain activation occurred by LED light stimulation. For investigate of brain activation in experimental small animal, we used high magnetic field 9.4T MRI. Experimental small animal is Balb/c mouse, method of fMRI is using echo planar image (EPI). EPI method spend more less time than any other MRI method. For this reason, however, EPI data has low contrast. Due to the low contrast, image pre-processing is very hard and inaccuracy. In this study, we planned the study protocol, which is called block design in fMRI research field. The block designed has 8 LED light stimulation session and 8 rest session. All block is consist of 6 EPI images and acquired 1 slice of EPI image is 16 second. During the light session, we occurred LED light stimulation for 1 minutes 36 seconds. During the rest session, we do not occurred light stimulation and remain the light off state for 1 minutes 36 seconds. This session repeat the all over the EPI scan time, so the total spend time of EPI scan has almost 26 minutes. After acquired EPI data, we performed the analysis of this image data. In this study, we analysis of EPI data using statistical parametric map (SPM) software and performed image pre-processing such as realignment, co-registration, normalization, smoothing of EPI data. The pre-processing of fMRI data have to segmented using this software. However this method has 3 different method which is Gaussian nonparametric, warped modulate, and tissue probability map. In this study we performed the this 3 different method and compared how they can change the result of fMRI analysis results. The result of this study show that LED light stimulation was activate superior colliculus region in mouse brain. And the most higher activated value of segmentation method was using tissue probability map. this study may help to improve brain activation study using EPI and SPM analysis.

Performance Analysis of Audio Data Hiding Method based on Phase Information with Various Window Length (주파수 변환의 길이에 따른 위상 기반 오디오 정보 은닉 기술의 음질 및 성능 분석)

  • Cho, Kiho;Kim, Nam Soo
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.12
    • /
    • pp.232-237
    • /
    • 2013
  • The role of the window length of time-frequency transformation is important for the audio data hiding methods utilizing phase information. In this paper, the experiments for our audio data hiding method were conducted in order to evaluate the audio quality and robustness against reverberant environment. The experimental results showed the tendency that the worse audio quality but better robustness were obtained when the lengthy window was applied. The important reason for quality degradation was pre-echo which flatters the percussive sound. The results also indicated that the wireless communication theory related to the length of time-frequency transform can be applied in the field of audio data hiding and acoustic data transmission.

Improvement of non-negative matrix factorization-based reverberation suppression for bistatic active sonar (양상태 능동 소나를 위한 비음수 행렬 분해 기반의 잔향 제거 기법의 성능 개선)

  • Lee, Seokjin;Lee, Yongon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.4
    • /
    • pp.468-479
    • /
    • 2022
  • To detect targets with active sonar system in the underwater environments, the targets are localized by receiving the echoes of the transmitted sounds reflected from the targets. In this case, reverberation from the scatterers is also generated, which prevents detection of the target echo. To detect the target effectively, reverberation suppression techniques such as pre-whitening based on autoregressive model and principal component inversion have been studied, and recently a Non-negative Matrix Factorization (NMF)-based technique has been also devised. The NMF-based reverberation suppression technique shows improved performance compared to the conventional methods, but the geometry of the transducer and receiver and attenuation by distance have not been considered. In this paper, the performance is improved through preprocessing such as the directionality of the receiver, Doppler related thereto, and attenuation for distance, in the case of using a continuous wave with a bistatic sonar. In order to evaluate the performance of the proposed system, simulation with a reverberation model was performed. The results show that the detection probability performance improved by 10 % to 40 % at a low false alarm probability of 1 % relative to the conventional non-negative matrix factorization.

Usefulness of High-B-value Diffusion - Weighted MR Imaging for the Pre-operative Detection of Rectal Cancers (B-values 변환 자기공명영상: 국소 직장암 수술 전 검출을 위한 적합한 b-value 유용성)

  • Lee, Jae-Seung;Goo, Eun-Hoe;Lee, Sun-Yeob;Park, Cheol-Soo;Choi, Ji-Won
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.12
    • /
    • pp.683-690
    • /
    • 2009
  • The purpose of this study is to evaluate the usefulness of high-b-values diffusion weighted magnetic resonance imaging for the preoperative detection of focal rectum cancers. 60patients with diffusion weighted imaging were evaluated for the presence of rectal cancers. Forty were male and twenty were female, and their ages ranged from 38 to 71 (mean, 56) years. Used equipment was 1.5Tesla MRI((GE, General Electric Medical System, Excite HD). Examination protocols were used the fast spin echo T2, T1 weighted imaging. All examination protocols were performed by the same location with diffusion weighted imaging for accuracy detection. The b-values used in DWI were 250, 500, 750, 1000. 1500, 2000$(s/mm^2)$. The rectum, bladder to tumor contrast-to-noise ratio (CNR) of MR images were quantitativlely analyzed using GE software Functool tool, four experienced radiologists and three radiotechnologists qualitatively evaluated image quality in terms of image artifacts, lesion conspicuity and rectal wall. These data were analysed by using ANOVA and Freedman test with each b-value(p<0.05). Contrast to noise ratio of rectum, bladder and tumor in b-value 1000 were 27.21, 24.44, respectively(p<0.05) and aADC value was $0.73\times10^{-3}$. As a qualitative analysis, the conspicuity and discrimination from the rectal wall of lesions were high results as $4.0\pm0.14$, $4.4\pm0.16$ on b-value 1000(p<0.05), image artifacts were high results as $4.8\pm0.25$ on b-value 2000(p<0.05). In conclusion, DWI was provided useful information with depicting the pre-operative detection of rectal cancers, High-b-value 1000 image was the most excellent DWI value.

A Study on Sexual Function of Women with Coronary Artery Disease (관상동맥질환 여성의 성기능에 관한 연구)

  • Kim, Choon Shim;So, Hyang Sook
    • Korean Journal of Adult Nursing
    • /
    • v.12 no.1
    • /
    • pp.99-111
    • /
    • 2000
  • The purpose of this study was to identify risk factors related to sexual function of women with coronary artery disease, and to determine the predictors of sexual function. The study design, a descriptive correlational study, was done through structural questionnaire and interview. A total of 50 subjects from C University Hospital at Kwang-ju city who have undergone coronary angiography at department of cardiology were observed and interviewed from Feb. 22, 1999 to March. 23, 1999. The number of affected vessels, the level of total serum cholesterol, and the ejection fraction of 2-D echo cardiography were analyzed to evaluate the severity of coronary artery disease. And also type A behavior pattern, health behavior, Brief Index of Sexual Functioning for Women (BISF-W) were measured. The data obtained were analyzed using percentage, mean and standard deviation, t-test, ANOVA, Pearson's correlation coefficient, and stepwise multiple regression analysis via SPSS PC+. The results of this study were as follows: 1. The mean age of the subjects were 58.1 and 72.0% of those have been married over 30 years. Seventy two percentage were unemployed and monthly family income of 56.6% was less than 1,000,000 won (approximately $ 840). Eighty percent were in their postmenopausal state, and the frequency of sexual intercourse of 84.0% were two to three times per month. 2. The scores of type A behavior pattern were from 16 to 38(mean 24.94) and health behavior ranged from 21 to 43(mean 31.2). Abstinence from smoking, alcohol, and caffeine were best compliant factors and weight control and exercise were least abided ones. The result of 2D-ECHO EF showed that the half of the subjects were abnormal, and 24% had more than 240mg/dl of total serum cholesterol. The coronary angiography showed that 64% of the subjects had more than one affected vessels. 3. The predictors to explain the factor score of 'orgasm' were number of health examination, the pre- or post-menopausal state, protestant, number of coronary vessel affected, level of serum total cholesterol, and comorbid group of hypertension and diabetes, and it's total variance accounted for 52.4%. The predictors to explain the factor score of 'sexual activity' were comorbid group of hypertension and diabetes and type A behavior pattern, which accounted for 22.4% of total variance. The predictors to explain the factor score of 'sexual satisfaction' were type A behavior pattern, no religion, exercise, level of serum total cholesterol, and pre or post menopausal state, which accounted for 52.1%. The predictors to explain the factor score of 'sexual desire' were the period of marriage, type A behavior, employment or unemployment, and weight control, which accounted for 43.2%. The predictors to explain the factor score of 'external force of sexual functioning' were physical overload and exercise, which accounted for 41.1%. The predictors to explain the factor score of 'sexual activity' were family monthly income, catholics, and exercise, and which accounted for 35.4%. Above results lead us to some consensus that sexual function of women with coronary artery disease is related to various factors including vasogenic factors such as total serum cholesterol level, number of coronary vessel affected, an endocrinal factor such as menopausal state, and type A behavior pattern as a sociopshychological factor. And also health behaviors such as fitness care, overwork, weight control, and emotional tension are contributed to sexual function.

  • PDF