• 제목/요약/키워드: power transfer capability

검색결과 186건 처리시간 0.026초

Development of a Computer Code for Low-and Intermediate-Level Radioactive Waste Disposal Safety Assessment

  • Park, J.W.;Kim, C.L.;Lee, E.Y.;Lee, Y.M.;Kang, C.H.;Zhou, W.;Kozak, M.W.
    • Journal of Radiation Protection and Research
    • /
    • 제29권1호
    • /
    • pp.41-48
    • /
    • 2004
  • A safety assessment code, called SAGE (Safety Assessment Groundwater Evaluation), has been developed to describe post-closure radionuclide releases and potential radiological doses for low- and intermediate-level radioactive waste (LILW) disposal in an engineered vault facility in Korea. The conceptual model implemented in the code is focused on the release of radionuclide from a gradually degrading engineered barrier system to an underlying unsaturated zone, thence to a saturated groundwater zone. The radionuclide transport equations are solved by spatially discretizing the disposal system into a series of compartments. Mass transfer between compartments is by diffusion/dispersion and advection. In all compartments, radionuclides ate decayed either as a single-member chain or as multi-member chains. The biosphere is represented as a set of steady-state, radionuclide-specific pathway dose conversion factors that are multiplied by the appropriate release rate from the far field for each pathway. The code has the capability to treat input parameters either deterministically or probabilistically. Parameter input is achieved through a user-friendly Graphical User Interface. An application is presented, which is compared against safety assessment results from the other computer codes, to benchmark the reliability of system-level conceptual modeling of the code.

Improvement in Plume Dispersion Formulas for Stack Emissions Using Ground-based Imaging-DOAS Data

  • Lee, Hanlim;Ryu, Jaeyong;Jeong, Ukkyo;Noh, Youngmin;Shin, Sung Kyun;Hong, Hyunkee;Kwon, Soonchul
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권12호
    • /
    • pp.3427-3432
    • /
    • 2014
  • This study introduces a new method of combining Imaging Differential Optical Absorption Spectroscopy (Imaging-DOAS) data and plume dispersion formulas for power plant emissions to determine the three-dimensional structure of a dispersing pollution plume and the spatial distributions of trace gas volume mixing ratios (VMRs) under conditions of negligible water droplet and aerosol effects on radiative transfer within the plume. This novel remote-sensing method, applied to a power plant stack plume, was used to calculate the two-dimensional distributions of sulfur dioxide ($SO_2$) and nitrogen dioxide ($NO_2$) VMRs in stack emissions for the first time. High $SO_2$ VMRs were observed only near the emission source, whereas high $NO_2$ VMRs were observed at locations several hundreds of meters away from the initial emission. The results of this study demonstrate the capability of this new method as a tool for estimating plume dimensions and trace gas VMRs in power plant emissions.

First Simultaneous Visualization of SO2 and NO2 Plume Dispersions using Imaging Differential Optical Absorption Spectroscopy

  • Lee, Hanlim;Noh, Youngmin;Kwon, Soonchul;Hong, Hyunkee;Han, Kyung-Soo
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권4호
    • /
    • pp.1191-1194
    • /
    • 2014
  • Imaging Differential Optical Absorption Spectroscopy (Imaging-DOAS) has been utilized in recent years to provide slant column density (SCD) distributions of several trace gas species in the plume. The present study introduces a new method using Imaging-DOAS data to determine two-dimensional plume structure from the plume emissions of power plant in conditions of negligible aerosol effects on radiative transfer within the plume. We demonstrates for the first time that two-dimensional distributions of sulfur dioxide ($SO_2$) and nitrogen dioxide ($NO_2$) in power plant emissions can be determined simultaneously in terms of SCD distribution. The $SO_2$ SCD values generally decreased with increasing distance from the stack and with distance from the center of the plume. Meanwhile, high $NO_2$ SCD was observed at locations several hundred meters away from the first stack due to the ratio change of NO to $NO_2$ in NOx concentration, attributed to the NO oxidation by $O_3$. The results of this study show the capability of the Imaging-DOAS technique as a tool to estimate plume dimensions in power plant emissions.

해석적 근사해에 근거한 스터링기관의 2차단열해석법 (A Second-Order Adiabatic Analysis Method of Stirling Engines Based on the Approximate Analytical Solution)

  • 유호선
    • 대한기계학회논문집
    • /
    • 제16권4호
    • /
    • pp.787-794
    • /
    • 1992
  • 본 연구에서는 이미 알려진 이상적인 단열모델에 대한 해석적 근사해를 기본 해로 취하고, 열교환과정의 손실 및 작동유체의 유동손실 등 성능에 미치는 영향이 비교적 큰 인자만을 고려하여, 성능을 쉽게 예측할 수 있는 2차단열해석법의 하나를 개발하고자 한다. 방법의 타당성및 적용예를 보이기 위하여 기존의 스터링기관중 각 종제원및 실험결과가 발표되어 있어 비교의 기준으로서 적합한 GPU-3(ground power unit)기관을 대상으로 해석방법을 실제 적용하고 결과를 고찰하기로 한다.

무선 에너지 전송을 위한 Class-E 전력증폭기 설계 (Design of Class-E Power Amplifier for Wireless Energy Transfer)

  • 고승기;서철헌
    • 대한전자공학회논문지TC
    • /
    • 제48권2호
    • /
    • pp.85-89
    • /
    • 2011
  • 본 논문에서는 메타구조를 이용하여 하나의 RF LDMOS로 새로운 Class-E 전력증폭기를 구현하였다. CRLH 구조는 Class-E 전력증폭기 특성을 갖는 메타물질 전송 선로를 만들 수 있다. CRLH 전송 선로는 전력증폭기의 정합 회로를 구현을 위하여 주파수 오프셋과 CRLH 전송 선로의 비선형 위상 기울기에 의해 얻을 수 있다. 또한, 제안된 전력증폭기의 효율을 향상 시키기 위하여 출력 정합 회로에 CRLH 구조를 이용하여 구현하였다. 동작 주파수는 13.56MHz로 정하였다. Class-E 전력 증폭기의 측정된 출력 전력은 39.83dBm, 이득은 11.83 dB이다. 이 지점에서 얻은 전력효율(PAE)은 73%이다.

전자장비 캐비넷의 냉각특성에 관한 실험적 연구 (An experimental study on the cooling characteristics of electronic cabinet)

  • 박종흥;이재헌
    • 대한기계학회논문집B
    • /
    • 제20권7호
    • /
    • pp.2356-2366
    • /
    • 1996
  • High-power electronic chips have been advanced to such an extent that the heat dissipation capability of a system design has become one of the primary limiting factors. Therefore, thermal design must be considered in the early stage of the electronic system development. In present paper, the results of an experimental study on the forced convection cooling are presented to evaluate cooling performance of an electronic cabinet which in generally used for telecommunication system. Temperatures and thermal resistances are applied to compare the heat transfer characteristics for various locations of a fan unit as well as various configuration of non-uniform powering modules. As a result, the optimal configuration of a fan unit and powering configuration is suggested for the effective thermal design of telecommunication system.

Evolution, Fields of Research, and Future of Chemical-Looping Combustion (CLC) process: A Review

  • Shahrestani, Masoumeh Moheb;Rahimi, Amir
    • Environmental Engineering Research
    • /
    • 제19권4호
    • /
    • pp.299-308
    • /
    • 2014
  • This study presents a review on Chemical looping combustion (CLC) development, design aspects and modeling. The CLC is in fact an unmixed combustion based on the transfer of oxygen to the fuel by a solid oxygen carrier material avoiding the direct contact between air and fuel. The CLC process is considered as a very promising combustion technology for power plants and chemical industries due to its inherent capability of $CO_2$ capturing, which avoids extra separation costs of the of $CO_2$ from the rest of flue gases. This review covers the issues related to oxygen carrier materials. The modeling works are reviewed and different aspects of modeling are considered, as well. The main drawbacks and future research and prospects are remarked.

계통의 종합적 미소신호 안정도 해석 알고리듬과 ATC 산정에의 응용에 관한 연구 (A Unified Framework for Small Signal Stability Analysis of Power Systems and Its Application to Available Transfer Capability)

  • 김상암;송화창;이병준;권세혁
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권10호
    • /
    • pp.1222-1230
    • /
    • 1999
  • This paper presents the framework for analysis of small-signal stability. In this framework the equilibrium points of system DAE model are traced using continuation method and instability points are determined on the solution path. Especially Implicit shift QR-modified Arnoldi method is utilized to calculated the rightmost eigenvalues. Small-signal stability is becoming one of the major factors that affect the ATC in the environment of deregulation. Stability limited ATC is easily evaluated in this stability analysis process.

  • PDF

기존 교류선로의 직류변환 송전방식에 있어서 선정기법에 관한 연구 (A Study of Selection of Existing A.C. Transmission Facilities for Use with D.C.)

  • 김동준;문영환;이동일;윤재영;양광호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.283-285
    • /
    • 2002
  • The paper describes a study of selection of existing a.c. Transmission facilities converted fur use with d.c. system. In order to increasing the power transfer capability of existing a.c. transmission facilities, d.c. is one of good alternatives. Some advantages and disadvantages of this method are discussed, and the selection method of existing transmission facilities for use with d.c. considering economics and stability is presented in this paper.

  • PDF

전력구 내 지중선을 이용한 2W급 상용주파수 무선전력 수신장치 개발 (Development of 2W-Level Wireless Powered Energy Harvesting Receiver using 60Hz power line in Electricity Cable Tunnel)

  • 장기찬;최보환;임춘택
    • 전력전자학회논문지
    • /
    • 제21권4호
    • /
    • pp.296-301
    • /
    • 2016
  • Using high magnetic flux from a 60 Hz high-current cable, a 2 W wireless-powered energy harvesting receiver for sensor operation, internet of things (IoT) devices, and LED lights inside electrical cable tunnels is proposed. The proposed receiver comprises a copper coil with a high number of turns, a ring-shaped ferromagnetic core, a capacitor for compensating for the impedance of the coil in series, and a rectifier with various types of loads, such as sensors, IoT devices, and LEDs. To achieve safe and easy installation around the power cable, the proposed ring-shaped receiver is designed to easily open or close using a clothespin-shaped handle, which is made of highly-insulated plastic. Laminated silicon steel plates are assembled and used as the core because of their mechanical robustness and high saturation flux density characteristic, in which the thickness of each isolated plate is 0.3 mm. The series-connected resonant capacitor, which is appropriate for low-voltage applications, is used together with the proposed receiver coil. The concept of the figure of merit, which is the product weight and cost of both the silicon steel plate and the copper wire, is used for an optimized design; therefore, the weight of the fabricated receiver and the price of raw material is 750 gf and USD $2 each, respectively. The 2.2 W powering capability of the fabricated receiver was experimentally verified with a power cable current of $100A_{rms}$ at 60Hz.