• 제목/요약/키워드: power spectral density ratio

검색결과 55건 처리시간 0.022초

페이딩과 재밍 환경에서 LDPC 부호화된 OFDM/DS 시스템의 성능 (Performance of LDPC Coded OFDM/DS Under Fading and Jamming Environment)

  • 서동철;이우찬;김종훈
    • 한국군사과학기술학회지
    • /
    • 제11권5호
    • /
    • pp.23-33
    • /
    • 2008
  • In this paper, we verify the performance of LDPC coded OFDM/DS system by Monte-Carlo simulation of BER on Eb/No. The simulation results show that LDPC coded OFDM/DS has a strong anti-jamming characteristic over pulse-noise jammer and partial-band noise jammer. The performance of LDPC coded OFDM/DS system is evaluated on both faded waveforms and non-faded waveforms. For non-faded waveforms, high coding gain is attained due to LDPC, even when waveforms have short PN sequence and JSR is only 5dB. Especially, the increase in the repeated number of LDPC decoding enhances coding gain. However, faded waveforms cannot achieve sufficient average effect when PN sequence is short. High coding gain of faded waveforms can be achieved by extending length of PN sequence. In addition, we compare LDPC coded OFDM/DS system with Convolutional coded OFDM/DS system. The simulation results illustrate that when LDPC coded OFDM/DS system with short PN sequence has sufficient average effects, the system shows lower BER than Convolutional coded OFDM/DS system with long PN sequence.

일렬관군에서의 난류 후류특성에 관한 연구 (Turbulent Wake Flow around Tubes in Single Row Tube Banks)

  • 조석호;부정숙
    • 대한기계학회논문집
    • /
    • 제13권5호
    • /
    • pp.1023-1031
    • /
    • 1989
  • 본 연구에서는 격자관군(in-line tube banks)과 엇갈림관군(staggered tube banks)에서의 유동특성을 해명하기 위한 기초로서, 일렬관군에 대해 유동특성을 통계적으로 조사한다. 이를 위해, 먼저 유동의 가시화와 관의 표면압력 측정실험이 행해진다. 또한, 통계적 기법의 도입을 통하여 관 주위의 평균속도, 난류강도, 파워 스펙트럼 밀도함수, 스트로홀수(strouhal number), 자기상관계수, 활률 밀도함수 등의 측정이 수행된다.

Performance Analysis of Decode-and-Forward Relaying with Partial Relay Selection for Multihop Transmission over Rayleigh Fading Channels

  • Bao, Vo Nguyen Quoe;Kong, Hyung-Yun
    • Journal of Communications and Networks
    • /
    • 제12권5호
    • /
    • pp.433-441
    • /
    • 2010
  • Multihop transmission is a promising technique that helps in achieving broader coverage (excellent network connectivity) and preventing the impairment of wireless channels. This paper proposes a cluster-based multihop wireless network that makes use of the advantages of multihop relaying, i.e., path loss gain, and partial relay selection in each hop, i.e., spatial diversity. In this partial relay selection, the node with the maximum instantaneous channel gain will serve as the sender for the next hop. With the proposed protocol, the transmit power and spectral efficiency can be improved over those in the case of direct transmission and conventional multihop transmission. Moreover, at a high signal-to-noise ratio (SNR), the performance of the system with at least two nodes in each cluster is dependent only on the last hop and not on any of the intermediate hops. For a practically feasible decode-and-forward relay strategy, a compact expression for the probability density function of the end-to-end SNR at the destination is derived. This expression is then used to derive closed-form expressions for the outage probability, average symbol error rate, and average bit error rate for M-ary square quadrature amplitude modulation as well as to determine the spectral efficiency of the system. In addition, the probability of SNR gain over direct transmission is investigated for different environments. The mathematical analysis is verified by various simulation results for demonstrating the accuracy of the theoretical approach.

Feasibility study of using triple-energy CT images for improving stopping power estimation

  • Yejin Kim;Jin Sung Kim ;Seungryong Cho
    • Nuclear Engineering and Technology
    • /
    • 제55권4호
    • /
    • pp.1342-1349
    • /
    • 2023
  • The planning accuracy of charged particle therapy (CPT) is subject to the accuracy of stopping power (SP) estimation. In this study, we propose a method of deriving a pseudo-triple-energy CT (pTECT) that can be achievable in the existing dual-energy CT (DECT) systems for better SP estimation. In order to remove the direct effect of errors in CT values, relative CT values according to three scanning voltage settings were used. CT values of each tissue substitute phantom were measured to show the non-linearity of the values thereby suggesting the absolute difference and ratio of CT values as parameters for SP estimation. Electron density, effective atomic number (EAN), mean excitation energy and SP were calculated based on these parameters. Two of conventional methods were implemented and compared to the proposed pTECT method in terms of residuals, absolute error and root-mean-square-error (RMSE). The proposed method outperformed the comparison methods in every evaluation metrics. Especially, the estimation error for EAN and mean excitation using pTECT were converging to zero. In this proof-of-concept study, we showed the feasibility of using three CT values for accurate SP estimation. Our suggested pTECT method indicates potential clinical utility of spectral CT imaging for CPT planning.

Growth and Photoconductive Characteristics of $CdS_{1-x}Se_x$ Thin Films by the Hot Wall Epitaxy

  • Youn, Seuk-Jin;Hong, Kwang-Joon
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.1
    • /
    • pp.349-352
    • /
    • 2004
  • The $CdS_{1-x}Se_x$ thin films were grown on the GaAs(100) wafers by a Hot Wall Epitaxy method(HWE). The temperatures the source and the substrate temperature are $580^{\circ}C\;and\;440^{\circ}C$ respectively. The crystalline structure of thin films was investigated by double crystal X-tay diffraction(DCXD). Hall effect on the sample was measured by the van der Pauw method and studied on the carrier density and mobility dependence on temperature. In order to explore the applicability as a photoconductive cell, we measured the sensitivity($\gamma$), the ratio of photocurrent to darkcurrent(pc/dc), maximum allowable power dissipation(MAPD), spectral response and response time.

  • PDF

Detrended fluctuation analysis of magnetic parameters of solar active regions

  • Lee, Eo-Jin;Moon, Yong-Jae
    • 천문학회보
    • /
    • 제41권1호
    • /
    • pp.81.2-81.2
    • /
    • 2016
  • Many signals in the nature have power-law behaviors, namely they are "scale-free". The method of detrended fluctuation analysis (DFA), as one of the popular methods (e.g., Rescaled range analysis and Spectral analysis) for determining scale-free nature of time series, has a very important advantage that the DFA can be applied to both stationary and non-stationary signals. The analysis of time series using the DFA has been broadly used in physiology, finance, hydrology, meteorology, geology, and so on. We performed the DFA of 16 Spaceweather HMI Active Region Patch (SHARP) parameters for 38 HMI Active Region Patches (HARPs) obtained by Solar Dynamics Observatory (SDO) from May 2010 to June 2014. The main results from this study are as follows. (1) The most of the time series data are non-stationary. (2) The DFA scaling exponents of "mean vertical current density" for 38 HARPs have a negative correlation coefficient (-0.41) with flare index. (3) The DFA scaling exponents of parameters such as "Sum of the absolute value of net currents per polarity", "Absolute value of the net current helicity", and "Mean photospheric excess magnetic energy density" for the most active HARPs having more than 10 major flares, have positive correlation coefficients (0.64, 0.59, and 0.53, respectively) with the ratio of "the number of CMEs associated with major flares" to "the number of major flares". Physical interpretations on our results will be discussed.

  • PDF

Growth and Photoconductive Characteristics of $AgInS_2$ Single Crystal Thin Films by the Hot Wall Epitaxy

  • Hong, Kwang-Joon
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.1
    • /
    • pp.381-384
    • /
    • 2004
  • The stochiometric nix of evaporating materials for the $AgInS_2$ single crystal thin films were prepared from horizontal furnace. The polycrystal structure obtaind from the power x-ray diffraction was chalcopyrite. The lattice costants $a_0\;and\;c_0$ were $a_0=5.86(5.82)\;A,\;c_0=11.355(11.17)\;A$. To obtains the single crystal thin films, $AgInS_2$ mixed crystal were deposited on throughly etched GaAs(100) by the Hot Wall Epitaxy(HWE) system. The temperates of the source and the substrate were $590^{\circ}C\;and\;450^{\circ}C$, respectively. The crystalline structure of single crystal thin films was investigated by the double crystal X-ray diffraction(DCXD). Hall effect on this sample was measured by the method of van der Pauw and studied on carrier density and mobility dependence on temperature. In order to explore the applicability as a photoconductive cell, we measured the sensitivity($\gamma$), the ratio of photocurrent to dark current (pc/dc), maximum allowable power dissipation(MAPD), spectral response and response time.

  • PDF

Mode identifiability of a cable-stayed bridge based on a Bayesian method

  • Zhang, Feng-Liang;Ni, Yi-Qing;Ni, Yan-Chun
    • Smart Structures and Systems
    • /
    • 제17권3호
    • /
    • pp.471-489
    • /
    • 2016
  • Modal identification based on ambient vibration data has attracted extensive attention in the past few decades. Since the excitation for ambient vibration tests is mainly from the environmental effects such as wind and traffic loading and no artificial excitation is applied, the signal to noise (s/n) ratio of the data acquired plays an important role in mode identifiability. Under ambient vibration conditions, certain modes may not be identifiable due to a low s/n ratio. This paper presents a study on the mode identifiability of an instrumented cable-stayed bridge with the use of acceleration response data measured by a long-term structural health monitoring system. A recently developed fast Bayesian FFT method is utilized to perform output-only modal identification. In addition to identifying the most probable values (MPVs) of modal parameters, the associated posterior uncertainties can be obtained by this method. Likewise, the power spectral density of modal force can be identified, and thus it is possible to obtain the modal s/n ratio. This provides an efficient way to investigate the mode identifiability. Three groups of data are utilized in this study: the first one is 10 data sets including six collected under normal wind conditions and four collected during typhoons; the second one is three data sets with wind speeds of about 7.5 m/s; and the third one is some blind data. The first two groups of data are used to perform ambient modal identification and help to estimate a critical value of the s/n ratio above which the deficient mode is identifiable, while the third group of data is used to perform verification. A couple of fundamental modes are identified, including the ones in the vertical and transverse directions respectively and coupled in both directions. The uncertainty and s/n ratio of the deficient mode are investigated and discussed. A critical value of the modal s/n ratio is suggested to evaluate the mode identifiability of the deficient mode. The work presented in this paper could provide a base for the vibration-based condition assessment in future.

CDMA 기지국에서 Pilot $E_c/I_o$ 보상기법을 이용한 수신감도 측정에 관한 연구 (A Study on Receiver Sensitivity Measurement using Pilot $E_c/I_o$ Compensation Method at CDMA Communication Network)

  • 정기혁;나극환
    • 대한전자공학회논문지TC
    • /
    • 제44권8호
    • /
    • pp.9-16
    • /
    • 2007
  • 운용중인 기지국에서 각종 RF 파라미터의 측정은 매우 제한적으로 이루어지고 있으며, 일부 수행되고 있는 측정에서 조차 비교적 측정이 용이한 순방향 항목에 집중되고 있다. 본 논문에서는 기지국에 설치된 순방향 모니터링 포트를 이용하여 기지국의 역방향의 무선 품질을 측정이 기능한 측정장치를 설계하여 실제 운용 중인 기지국에서 검증시험을 실시함으로써 연구의 완성도 향상을 꾀하였다. 수신감도의 측정은 내장된 CDMA 모뎀을 이용하여 기지국과 음성호가 연결된 상태에서 폐루프 전력제어에 의한 모뎀의 출력을 감시함으로써 이루어질 수 있도록 하였다. 보다 정확한 계측을 위하여 모뎀의 TxAdj 파라미터와 함께 디텍터에 의한 실측 데이터를 이용하였다. 정확한 수신감도의 측정을 위해서는 트래픽이 없는 상황에서 측정이 이루어져야 하지만, 운용중인 시스템에서는 상황재현이 어려우므로 통화량 증가에 의한 수신감도의 열화정도를 보상함으로써 시간에 구애받지 않고 정확한 측정값을 얻을 수 있도록 $E_c/I_o$에 의한 보상기법을 적용하였다.

HWE에 의한 $Cd_{1-x}Zn_xS $박막의 성장과 광전도 특성 (Growth of $Cd_{1-x}Zn_xS $ Thin films Using Hot Wall Epitaxy Method and Their Photoconductive Characteristics)

  • 홍광준;유상하
    • 한국결정학회지
    • /
    • 제9권1호
    • /
    • pp.53-63
    • /
    • 1998
  • HWE 방법에 의해 Cd1-xZnxS 박막을 (100)방향을 Si 기판 위에 성장시켰다. 증발원과 기판의 온도를 각각 600℃, 440℃로 하여 성장시킨 Cd1-xZnxS 박막의 이중 결정 X-선 요동곡선(DCRC)의 반폭치(FWHM)값이 265 arcsec로 가장 작았다. Van der Pauw 방법으로 Hall효과를 측정하여 운반자 농도와 Hall 이동도의 온도 의존성을 조사하였다. 광전도 셀의 특성으로 spectral response, 최대 허용소비전력(MAPD), 광전류와 암전류(pc/dc)의 비 및 응답시간을 측정하였다. Cd0.53Zn0.47S광전도 셀을 Cu증기 분위기에서 열처리한 경우 감도(γ)는 0.99, pc/dc은 1.65 ×10 7 그리고 최대 허용소비전력(MAPD)은 338mW, 오름시간 (rise time)은 9.7ms, 내림시간(decay time)은 9.3ms로 가장 좋은 광전도 특성을 얻었다.

  • PDF