• 제목/요약/키워드: power spectral density ratio

검색결과 55건 처리시간 0.02초

전신 마취 중 심박동변이도와 맥파전달시간 변화의 비교 (Comparison of Heart Rate Variability with Pulse Transit Time during General Anesthesia)

  • 백승완;김태균;김재형;전계록;예수영
    • 한국전기전자재료학회논문지
    • /
    • 제21권8호
    • /
    • pp.770-775
    • /
    • 2008
  • Autonomic nervous system of the anesthetized patients can be influenced by the many kinds of stimulations such as intubation, surgical incision and so on. The changes of the heart rates and blood pressures are surrogates of responses of the autonomic system to the external stimulations. Recently, the power spectral analysis of the heart rate variability (HRV) made it easy to know the fractions and changes of sympathetic and parasympathetic autonomic systems. In this study, the changes of pulse transit time, one of the response of vessels to stimulations, was investigated in relation to the HRV. Ten patients were examined and average age is 22.5 $\pm$ 11.04, average weight is 63 $\pm$ 14.4 kg. The patients were anesthetized only by sevoflurane inhalation. Pulse transit time is determined by calculating the difference of the time between the R peak of ECG and the characteristic point of the plethysmography. Power spectral density (PSD) of the HRV was achieved in the frequency of 0.04-0.15 (LF) and 0.15-0.4 (HF). Compared to preanesthetic period the values of LF and LF/HF ratio of HRV were decreased (p<0.05). HF and PTT was increased in anesthetic state with sevoflurane. Otherwise, after intubation, the HF was decreased and LF, LF/HF ratio and PTT were increased. PSD of the HRV is well-known for the index of the autonomic nervous activity. Not only HRV but PTT analysis also is a useful index reflecting the autonomic responses to various stimulations. And this analysis is useful in bed side monitoring because the calculating method is simple and it takes shorter processing time compared to the HRV analysis.

長方形柱 後流에 關한 實驗的 硏究 (An experimental Study of the Wake Flow Past a Rectangular Cylinder)

  • 남청도
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제15권3호
    • /
    • pp.45-56
    • /
    • 1991
  • This paper describes characteristics of the flow pattern of the flow past a rectangular cylinder experimentally investigated. The width-to-length ratio of the section varried from 2 to4. For the statistical treatment, autocorrelation coefficient, probability density function and power spectral density function are obtained by the digital processing technic through on-line system with a hot wire anemometer. As a results, it was found that strong periodic coherent eddies structure is sustained to about 20H downstream from the cylinder. And nearer the cylinder in the wake, the number of turbulent eddies of a large scale coherent structure are comparatively much more dominant than that of a small scale one. By the analysis of power spectrum, It was cleared that there exists a certain range of the width to length ratio between 2.5 and 3 of which the flow pattern changes abruptly with a sudden discontinuity in Strouhal number.

  • PDF

전신 마취 중 전력스펙트럼 분석을 이용한 마취심도 파라미터 개발 (Development of Parameters on Depth of Anesthesia using Power Spectrum Density Analysis during General Anesthesia)

  • 백승완;예수영;박준모;전계록
    • 한국전기전자재료학회논문지
    • /
    • 제22권6호
    • /
    • pp.537-545
    • /
    • 2009
  • In this paper, new parameters were developed to estimate the depth of anesthesia during a general anesthesia using EEG. Power spectral density(PSD) analysis was used for these parameters because EEG became slow wave during anesthesia. The new parameters were DTR, ATR, TDR, ADR, BTR and BDR applied to PSD. These parameters were compared with SEF which is conventionally used at clinic and confirmed clinical value. As the results, DTR, ATR, TDR, ADR among parameters were not useful compared with SEF but BTR and BDR is valuable for clinic. 15 patents, at pre-operation BDR the value is $265.36{\pm}25.29$, at induction the value is $129.23{\pm}34.92$, at operation the value is $154.99{\pm}38.34$, at awaked the value is $283.83{\pm}39.80$ and at post-operation the value is $234.80{\pm}23.46$. Also at pre-operation BTR value is $183.38{\pm}13.59$, at induction the value is $104.09{\pm}25.11$, at operation the value is $115.38{\pm}23.42$, at awaked the value is $190.33{\pm}23.31$ and at post-operation the value is $172.38{\pm}19.08$. Trend of BDR and BTR is similar to change of SEF, so two parameters are useful. to estimate the depth of anesthesia.

Effect of Total Collimation Width on Relative Electron Density, Effective Atomic Number, and Stopping Power Ratio Acquired by Dual-Layer Dual-Energy Computed Tomography

  • Jung, Seongmoon;Kim, Bitbyeol;Yoon, Euntaek;Kim, Jung-in;Park, Jong Min;Choi, Chang Heon
    • 한국의학물리학회지:의학물리
    • /
    • 제32권4호
    • /
    • pp.165-171
    • /
    • 2021
  • Purpose: This study aimed to evaluate the effect of collimator width on effective atomic number (EAN), relative electron density (RED), and stopping power ratio (SPR) measured by dual-layer dual-energy computed tomography (DL-DECT). Methods: CIRS electron density calibration phantoms with two different arrangements of material plugs were scanned by DL-DECT with two different collimator widths. The first phantom included two dense bone plugs, while the second excluded dense bone plugs. The collimator widths selected were 64 mm×0.625 mm for wider collimators and 16 mm×0.625 mm for narrow collimators. The scanning parameters were 120 kVp, 0.33 second gantry rotation, 3 mm slice thickness, B reconstruction filter, and spectral level 4. An image analysis portal system provided by a computed tomography (CT) manufacturer was used to derive the EAN and RED of the phantoms from the combination of low energy and high energy CT images. The EAN and RED were compared between the images scanned using the two different collimation widths. Results: The CT images with the wider collimation width generated more severe artifacts, particularly with high-density material (i.e., dense bone). RED and EAN for tissues (excluding lung and bones) with the wider collimation width showed significant relative differences compared to the theoretical value (4.5% for RED and 20.6% for EAN), while those with the narrow collimation width were closer to the theoretical value of each material (2.2% for EAN and 2.3% for RED). Scanning with narrow collimation width increased the accuracy of SPR estimation even with high-density bone plugs in the phantom. Conclusions: The effect of CT collimation width on EAN, RED, and SPR measured by DL-DECT was evaluated. In order to improve the accuracy of the measured EAN, RED, and SPR by DL-DECT, CT scanning should be performed using narrow collimation widths.

절삭력 신호를 이용한 공구운동의 모델링과 고정도 표면생성에 관한 연구 (A study on the Modeling of Tool Motion and High Accuracy Surface Generation by Use of Cutting Force Signal)

  • 김정두;이은복
    • 대한기계학회논문집
    • /
    • 제17권8호
    • /
    • pp.1951-1962
    • /
    • 1993
  • The creation process of a typical machined surface is treated here as a dynamic system. An investigation is carried out to establish a relationship between the characteristics of cutting force fluctuations that cause vibration response of the tool-workpiece system and the formation of surface in face cutting by sintered carbide cutting tool. Cutting force is measured and analyzed in frequency domain. The power spectral densities of cutting force give a useful information in surface generation and it can be used to find out the control factor of surface roughness. The terms, PSD ratio & Normalized spindle frequency PSD, are defined and when the value of power in spindle frequency is absolutely little but relatively large, it is obtained high accuracy surface roughness. The aim of this research is to find surface profile by measured and analyzed cutting force signals. The simulation of surface generation gives the comprechension of its mechanism and help to predict and control the surface quality. In this study, it is suggested what informations about surface generation can be acquired from the cuttuing force signal and an way of generating a better surface.

OFDM 시스템의 PAPR 감소를 위한 Adaptive Sine Soft Clipping 기법에 관한 연구 (A Study on Adaptive Sine Soft Clipping Method for PAPR Reduction in OFDM System)

  • 유선용;김완태;조성준
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2007년도 추계종합학술대회
    • /
    • pp.340-343
    • /
    • 2007
  • OFDM (Orthogonal Frequency Division Multiplexing) 방식은 주파수 선택적 페이딩 (frequency selective fading)과 협대역 간섭 (narrowband interference)에 강한 전송 방식으로 고속 데이터 통신에 적합하다. 하지만, OFDM 신호는 독립적으로 변조된 많은 부반송파들로 구성되므로 이들이 동위상으로 더해질 때 신호의 진폭이 증가하여 PAPR (Peak-to-Average Power Ratio) 문제가 발생한다. 본 논문에서는 OFDM의 PAPR 감소는 물론 고주파 성분 제어를 통하여 대역 외 스펙트럼 방출을 줄이고 clipping에 의한 왜곡을 감소시킬 수 있다. 시뮬레이션 과정을 통해 OFDM 시스템에 제안하는 알고리즘을 적용했을 경우, PAPR의 감소 정도와 PSD (Power Spectral Density), BER (Bit Error Rate)을 분석한다.

  • PDF

Across-wind dynamic loads on L-shaped tall buildings

  • Li, Yi;Li, Qiu-Sheng
    • Wind and Structures
    • /
    • 제23권5호
    • /
    • pp.385-403
    • /
    • 2016
  • The across-wind dynamic loads on L-shaped tall buildings with various geometric dimensions were investigated through a series of wind tunnel testing. The lift coefficients, power spectral densities and vertical correlation coefficients of the across-wind loads were analyzed and discussed in details. Taking the side ratio and terrain category as key variables, empirical formulas for estimating the across-wind dynamic loads on L-shaped tall buildings were proposed on the basis of the wind tunnel testing results. Comparisons between the predictions by the empirical formulas and the wind tunnel test results were made to verify the accuracy and applicability of the proposed formulas. Moreover, a simplified procedure to evaluate the across-wind dynamic loads on L-shaped tall buildings was derived from the proposed formulas. This study aims to provide a simple and reliable way for the estimation of across-wind dynamic loads on L-shaped tall buildings.

차기 군 위성통신망 체계에서 이기종 단말 운용을 고려한 전력제어 기반 MF-TDMA 자원할당 기법 (A Power Control-Based MF-TDMA Resource Allocation Scheme for Next Generation Military Satellite Communication Systems)

  • 우순;박형원;이호섭;유연상;정병기
    • 한국통신학회논문지
    • /
    • 제37C권11호
    • /
    • pp.1138-1147
    • /
    • 2012
  • 본 논문에서는 차기 군 위성통신망 체계에서 서로 다른 통신 능력을 갖는 이기종 단말을 동일 중계기 대역폭내에서 효과적으로 통합하여 운용하기 위해 전력제어를 적용한 MF-TDMA 자원할당기법을 제안한다. 제안하는 알고리즘은 burst 크기 결정 단계와 burst 구조 결정단계의 2단계로 수행된다. 먼저 burst 크기 결정 단계에서는 각 단말의 채널 상태를 기반으로 링크 버짓을 분석하여 적용 가능한 ACM 레벨과 이에 따른 burst 크기를 결정한다. 다음으로 burst 구조 결정단계에서는 앞서 도출된 각 단말 별 burst 크기를 기반으로 시간-주파수 축 상에서 할당 가능한 burst 구조를 도출하고 각 구조 별 가용 Power spectral density(PSD) 구간을 계산한다. 이기종 단말을 단일 중계기로 통합하기 위해 각 burst의 가용 PSD 구간 내에서 전력제어를 수행하며, 동일 PSD 구간을 갖는 burst를 그룹화하여 MF-TDMA 프레임 내에 할당한다. 추가적으로 할당되지 못하고 남는 슬롯에 대한 자원할당 효율을 향상시키기 위해 설정된 PSD 구간 내에서 ACM 레벨을 조절하여 빈 슬롯을 활용할 수 있는 방안을 적용하였다. 제안하는 알고리즘은 주파수 사용효율, 슬롯할당 거부율 및 burst packing 효율 측면에서 기존 방식과 비교하였으며, 기존 방식에 비해 우수한 성능을 제공함을 확인하였다.

Passive control of seismically excited structures by the liquid column vibration absorber

  • Konar, Tanmoy;Ghosh, Aparna Dey
    • Structural Engineering and Mechanics
    • /
    • 제36권5호
    • /
    • pp.561-573
    • /
    • 2010
  • The potential of the liquid column vibration absorber (LCVA) as a seismic vibration control device for structures has been explored in this paper. In this work, the structure has been modeled as a linear, viscously damped single-degree-of-freedom (SDOF) system. The governing differential equations of motion for the damper liquid and for the coupled structure-LCVA system have been derived from dynamic equilibrium. The nonlinear orifice damping in the LCVA has been linearized by a stochastic equivalent linearization technique. A transfer function formulation for the structure-LCVA system has been presented. The design parameters of the LCVA have been identified and by applying the transfer function formulation the optimum combination of these parameters has been determined to obtain the most efficient control performance of the LCVA in terms of the reduction in the root-mean-square (r.m.s.) displacement response of the structure. The study has been carried out for an example structure subjected to base input characterized by a white noise power spectral density function (PSDF). The sensitivity of the performance of the LCVA to the coefficient of head loss and to the tuning ratio have also been examined and compared with that of the liquid column damper (LCD). Finally, a simulation study has been carried out with a recorded accelerogram, to demonstrate the effectiveness of the LCVA.

바이모달 스펙트럼 특성을 가지는 정상확률과정에 대한 다점계류라인의 피로손상도 조합기법 연구 (Fatigue Damage Combination for Spread Mooring System under Stationary Random Process with Bimodal Spectrum Characteristics)

  • 임유창;김경수;정준모
    • 대한조선학회논문집
    • /
    • 제47권6호
    • /
    • pp.813-820
    • /
    • 2010
  • The spread mooring system for FPSO is developed to explore deep sea area, in which swell is dominant. It is known that the tension response of mooring lines in this sea area shows bimodal spectrum. Assuming normal distribution of tension profile and Rayleigh distribution of tension amplitude, the power spectral density function (PSD) of the mooring tension under the bimodal stationary random process is applied for the calculation of spectrum fatigue. Three popular methods, which are simple summation method, combined spectrum method and Jioa-Moan method, are used to combine fatigue damages from bimodal spectrum characteristics. Each damage value is compared with damage using Rainflow Cycle Counting (RCC) method which is believed to be close to exact solution. Vanmarcke' parameter and RMS(Root Mean Square) ratio are employed to assess relative damage variations between from RCC method and from three combination methods. Finally the most reliable fatigue damage combining method for spread mooring system is suggested.