• Title/Summary/Keyword: power recorder

Search Result 53, Processing Time 0.036 seconds

Design of Voltage Equalizer of Li-ion Battery Pack (리튬-이온 배터리팩의 전압안정화회로 설계)

  • 황호석;남종하;최진홍;장대경;박민기
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.2
    • /
    • pp.187-193
    • /
    • 2004
  • For a power source of usual electronic devices such as PDA, smart phone, UPS and electric vehicle, the battery made of serially connected multiple cells is generally used. In this case, if there are some unbalanced among cell voltages, the total lifetime and the total capacity of the battery are limited to a lower value. To maintain a balanced condition in cells, an effective method of regulating the cell voltage in indispensable. In this paper, we propose the design of a balancing circuit for electronic appliances. The balancing system was controlled by a micro-controller which enables to implement the balancing action during charging period. Proposed method has been verified by the experiment using the charger and recorder. The experimental results show that the individual battery equalization can improve battery capacity and battery lifetime and performance through an extended operational time.

Calculation of Transient Recovery Voltage on the Transmission Line due to High Impedance Arc Fault and Analysis of it's waveform (고저항 아크 지락에 의한 송전선로 과도회복전압 계산과 고장전류 파형 분석)

  • Shim, Eung-Bo
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.527-528
    • /
    • 2011
  • 송전선로에서 발생하는 고장의 대부분은 낙뢰에 의한 상-대지간 섬락이나 외물접촉, 혹은 애자련의 오손에 의한 절연파괴 등이 대부분이다. 그리고 대분의 고장은 큰 고장전류를 흘리게 되어 보호계전기가 동작하여 고장구간을 신속하게 분리하게 된다. 그러나, 본 고장사례는 매우 희귀한 고장 사례로서, 고저항 아크 지락에 의하여 발생하는 과도회복전압(TRV: Transient Recovery Voltage)이 애자련에 섬락을 일으킨 경우이다. 본 연구에서는 EMTP (Electro-Magnetic Transient Program)를 이용하여 고저항 지락시 아크의 단속에 의하여 과도회복전압이 발생할 가능성이 있음을 보였으며, 고장기록장치(Fault Recorder)에 나타난 파형 기록과의 유사성을 확인하였다. 또한, 고저항 지락에 의하여 직류분이 초기에 방전됨으로써 고장전류 파형에 직류분 오프셋이 나타나지 않게 됨을 밝혔다.

  • PDF

CONSTRUCTION OF 21CM COSMIC RADIO ANTENNA (21CM 우주전파 수신용 안테나의 제작)

  • Park, Jong-Ae;Yang, Jong-Man;Han, Seok-Tae;Park, Yong-Seon
    • Publications of The Korean Astronomical Society
    • /
    • v.8 no.1
    • /
    • pp.1-15
    • /
    • 1993
  • We made a pyramidal horn antenna system for 21cm cosmic radio wave. The antenna system has a rectangular waveguide with $TE_{10}$ mode and a copper probe to detect the electromagnetic wave in waveguide. The parameters of the probe are obtained by experiments using two waveguides. Pyramidal horn antenna is designed to get a gain of 20dB. The size of the aperture of this horn is $94cm{\times}74cm$. The beam width of half power is about $14.7^{\circ}$ for the frequency of 1.4GHz. The horn is made of aluminum plate with a thickness of 2mm. The signal from horn and waveguide is amplified in a receiver system and is converted into DC in the detecter. The intensity of the signal is recorded on a chart recorder. We observed the sun using this simple radio telescope and obtained the brightness temperature of $2.2{\times}10^5K$, which indicates that the sun is quiet at 21cm.

  • PDF

Technical Trend on Excitation Capacitors on Harmonic Amplification of Wind Induction Generator (풍력 유도발전기의 여자 축전지에 따른 고주파 증폭에 관한 기술 동향)

  • Rho, Sang-Pil;Park, Jung-Seok;Lee, Young-Gil;Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1976-1977
    • /
    • 2007
  • This paper introduce the electrical quantities of a three-phase-connected wind induction generator (WIG) under sudden connection of static loads. An intelligent power-system recorder/monitor is employed to measure threephase voltages and currents of the studied system at WIG's terminals and load's terminals for 5 minutes. A laboratory 300 W wound-rotor induction machine driven by a blushless DC motor is utilized as the studied WIG. Since the generated harmonic currents are randomly varied, total harmonic distortion (THD) of current using cumulative probability density function is employed to determine the penetration of harmonic distortion. The results show that the harmonic currents generated by the studied WIG may be severely amplified to a high level by the connected self-excited capacitance at the stator's terminals.

  • PDF

Development of ECO Driving Meter System for Diesel Locomotives (디젤기관차 연료사용량 측정장치 개발)

  • Park, Tae-Gi;Lee, Eul-Jae
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2357-2364
    • /
    • 2011
  • Diesel locomotive operates the generator with the power from the diesel engine, and it consists of the typical serial-hybrid system which operates the train wheels by converting its generated electric energy into the torque of DC (or AC) motor. However, the technology of locomotives is only focused on trains' controlling power generation mechanism. Hence, it is a current issue that the efficiency of its engine and its generator is relatively lower than that of auto vehicles'. Particularly, since there are no proper equipment to measure the amount of fuel which is essentially necessary for the efficient use of fuel, it is not easy to confirm the instant amount of fuel use as well as the exact average fuel consumption per an hour. Due to those difficulties, it is urgent to develop the device that measures the fuel consumption. Plus, this use of the developed measuring device allows the various and useful analysis relating to the fuel consumption, and this could lead to establishing the efficient driving pattern regarding to fuel saving. This device consists of two flux (fuel level) measuring censors, MCU for calculating the measured values, the information recorder for saving measured values, and the display device for indicating the fuel amount consumed during driving.

  • PDF

Nurse's Power and Tactics in Nursing Practice (간호사의 업무수행상의 권한과 행사전략)

  • Han, Hye-Ja
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.5 no.1
    • /
    • pp.23-37
    • /
    • 1999
  • This study is to understand and to describe the power that a nurse experiences on nursing practice and then. to present a basic data for nurse's power-development, power improving and empowering. Ethnography was used to understand and to describe experience on exercising various powers occurred on nursing practice. and to analyze and to understand the meaning of a nurse's power. The objects was nurses. Ten nurses who have more than three year's experience were selected as objects from Cuniversity's hospital in Seoul from May of 1996 to August of 1997 through in-depth interview. participant observation, and phone interview. Instruments werw a portable recorder and field notes. I described a case appeared in a data using Agar's 'Pencil and scissors' method right after collecting materials. Then, Idescribed a theme discovered commonly. Followings are the results of the study. 1. There were three categories of relationships with main objects when nurses exercised their power on their practices: a therapeutic caring relationship with patients, a relationship of companion, vertical cooperation, and a constituent person with a doctor, and a relationship of cooperation, and a constituent person with administrative workers and medical technicians. 2. There were many types of nurse's power, tactics and various patient's responses about them. 1) Types of nurse's power to patients were giving information, controling environment, helping for cure, emotional support, and performing discretion. 2) Nurse's tatics for performing power were positive tactics neutral tactics, and negative tactics. 3) Patient's responses were appeared as compliance and noncompliance. Compliance were agreeing. taking nurse's advice, trusting, understanding, being admitted, exposuring himself, and appreciating. 3. There were types of nurse's power and performing tactics. 1) Types of power to a doctor were advice, informing, demanding and mediation. 2) Performings of tactics to a doctor were positive tactics, neutral tactics, and negative tactics. 3) Doctor's responses were appeared as accepting and unaccepting. Acceptings were taking in and appreciating, and unacceptings were denying nurse's advice and authoritative. 4. There were types of nurse's power and tactics about administrative workers and medical technicians and responses about them. 1) Types of power about administrative workers and medical technicians were suggestions and demands. 2) Power performings tactics were positive tactics.neutral tactics, and negative tactics. 3) Responses of administrative workers and medical technicians about nurse's power performing were appeared appeared as accepting and unacce pting. Acceptings were taking in, and unacceptings were denying. Therefore, it can be said that types of nurse's power and performing tactics on nursing practice and nurse's power based on responses of a patient, a doctor, an administrative worker, and a medical technicians are power or influence for agreeing, taking advice, trusting, understanding, exposuring himself, appreciating, and taking in to objects. The results of this study helped to understand nurse's power. I expect that this study will improve nure's power by using expert power, referent power, and legitimate power effectively among powers acmpanied with the origin and that nurses make ef-ort to improve professional knowledge and human nature so that they use this study as a chance to develope expert nursing practice.

  • PDF

Frequency Estimation Method using Recursive Discrete Wavelet Transform for Fault Disturbance Recorder (FDR를 위한 RDWT에 의한 주파수 추정 기법)

  • Park, Chul-Won;Ban, Yu-Hyeon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.8
    • /
    • pp.1492-1501
    • /
    • 2011
  • A wide-area protection intelligent technique has been used to improve a reliability in power systems and to prevent a blackout. Nowadays, voltage and current phasor estimation has been executed by GPS-based synchronized PMU, which has become an important way of wide-area blackout protection for the prevention of expending faults in power systems. As this technique has the difficulties in collecting and sharing of information, there have been used a FNET method for the wide-area intelligent protection. This technique is very useful for the prediction of the inception fault and for the prevention of fault propagation with accurate monitoring frequency and frequency deviation. It consists of FDRs and IMS. It is well known that FNET can detect the dynamic behavior of system and obtain the real-time frequency information. Therefore, FDRs must adopt a optimal frequency estimation method that is robust to noise and fault. In this paper, we present comparative studies for the frequency estimation method using IRDWT(improved recursive discrete wavelet transform), for the frequency estimation method using FRDWT(fast recursive discrete wavelet transform). we used the Republic of Korea 345kV power system modeling data by EMTP-RV. The user-defined arbitrary waveforms were used in order to evaluate the performance of the proposed two kinds of RDWT. Also, the frequency variation data in various range, both large range and small range, were used for simulation. The simulation results showed that the proposed frequency estimation technique using FRDWT can be the optimal frequency measurement method applied to FDRs.

Study on Production of Power Monitoring Unit for Electric Propulsion UAV (전기동력 무인항공기용 PMU의 개선 및 제작에 대한 연구)

  • Kang, Jin-Myeong;Jeong, Jin-Seok;Kang, Beom-Soo;Kim, Jang-Mok
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.45 no.2
    • /
    • pp.140-147
    • /
    • 2017
  • This paper describes the design and implementation of previously developed PMU (Power Monitoring Unit) for LiPB (Lithium-ion Polymer Battery) that is electric propulsion used as unmanned aerial vehicle's power source. Improved PMU provides stable voltage and current to various sensors and elctric motors necessary during flight. Voltage and current monitoring function that is measured by improved PMU more precisely be enhanced and the monitoring channel and temperature sensor is added. To verify the improved performance of the equipment, it is integrated to electric propulsion system of unmanned aerial vehicle. PMU is calibrated through the ground test. And PMU's performance is checked through the flight test.

Combustion Condition Monitoring of the Marine Diesel Engine using Acceleration Signal of Cylinder Head (실린더 헤더의 가속도 신호를 이용한 선박용 디젤엔진의 연소 상태 모니터링)

  • Seo, Jong-Cheol;Kim, Sang-Hwan;Lee, Don-Chool
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.10a
    • /
    • pp.607-610
    • /
    • 2009
  • The abnormal combustion in the running engine results to knocking which increases the pressure and temperature in the cylinder, thereby decreasing the generated power by reducing the thermal efficiency. When the temperature and pressure in the cylinder increased rapidly by knocking, abnormal combustion takes place and the engine power is decreased. To investigate the knocking phenomenon, accelerometers are installed in the cylinder head to monitor and diagnose the vibration signal. As method of signal analysis, the time-frequency analysis method was adapted for acquisition of vibration signal and analyzes engine combustion in the short time. In this experiment, after analyzing time data which is stored in the signal recorder in one unit work (4 strokes: 2 revolutions), the signal with frequency and Wavelet methods with extracted one engine combustion data was also analyzed. Then, normal condition with no knocking signal is analyzed at this time. Hereafter, the experiments made a standard for distinguishing normal and abnormal condition to be carried out in acquisition of vibration signal at all cylinders and extracting knocking signal. In addition, analyzing methods can be diverse with Symmetry Dot Patterns (SDP), Time Synchronous Average (TSA), Wigner-Ville Distribution (WVD), Wigner-Ville Spectrum (WVS) and Mean Instantaneous Power (MIP) in the cold test [2]. With signal processing of vibration from engine knocking sensor, the authors adapted a part of engine /rotor vibration analysis and monitoring system for marine vessels to prevent several problems due to engine knocking

  • PDF

Performance Analysis of Water-Water Heat Pump System of 100 kW Scale for Cooling Agricultural Facilities

  • Kang, Youn Ku;Ryou, Young Sun;Jang, Jae Kyung;Kim, Young Hwa;Kim, Jong Goo;Kang, Geum Chun
    • Journal of Biosystems Engineering
    • /
    • v.39 no.1
    • /
    • pp.34-38
    • /
    • 2014
  • Purpose: In this study, the performance of cooling system with the water-water heat pump system of 100kW scale made for cooling agricultural facilities, especially for horticultural facilities, was analyzed. It was intended to suggest performance criteria and performance improvement for the effective cooling system. Methods: The measuring instruments consisted of two flow meters, a power meter and thermocouples. An ultrasonic and a magnetic flow meter measured the flow rate of the water, which was equivalent to heat transfer fluid. The power meter measured electric power in kW consumed by the heat pump system. T-type thermocouples measured the temperature of each part of the heat pump system. All of measuring instruments were connected to the recorder to store all the data. Results: When the water temperature supplied into the evaporator of the heat pump system was over $20^{\circ}C$, the cooling Coefficient Of Performance(COP) of the system was higher than 3.0. As the water temperature supplied into the evaporator, gradually, lowered, the cooling COP, also, decreased, linearly. Especially, when the water temperature supplied into the evaporator was lower than $15^{\circ}C$, the cooling COP was lower below 2.5. Conclusions: In order to maintain the cooling COP higher than 3.0, we suggest that the water temperature supplied into evaporator from the thermal storage tank should be maintained above $20^{\circ}C$. Also, stratification in the thermal storage tank should be formed well and the circulating pumps and the pipe lines should be arranged in order for the relative low-temperature water to be stored in the lower part of the thermal storage tank.