• Title/Summary/Keyword: power quality

Search Result 5,333, Processing Time 0.034 seconds

A Study on the Quality Characteristics of Feedstocks for Power Bio-Fuel Oil (발전용 바이오중유용 원료물질의 품질특성 연구)

  • Jang, Eun-Jung;Lee, Mi-Eun;Park, Jo-Yong;Min, Kyung-Il;Yim, Eui-Soon;Ha, Jong-Han;Lee, Bong-Hee
    • Journal of the Korean Applied Science and Technology
    • /
    • v.32 no.1
    • /
    • pp.136-147
    • /
    • 2015
  • As it carry out RPS(Renewable Portfolio Standards), power producers are using the power bio-fuel oil to meet their RPS quota. In this study, we test the quality characteristics of raw materials for power bio-fuel oil and the property changes of power bio-fuel oil by the kind of feedstocks. The power bio-fuel oil and feedstocks were analyzed for item of quality standard such as acid number, viscosity and metal contents. And it was analyzed for composition distribution by FT-IT and HPLC. Such as low priced palm oil series has high acid number and ash contents due to high free-fatty acid and metal contents. And by-product of biodiesel have a tendency of high viscosity. The fuel properties of power bio-fuel oil, such as viscosity, acid number and metal contents are correlated with the constituent and the mixing ratio of the feedstocks.

Power Quality Impacts of an Electric Arc Furnace and Its Compensation

  • Esfandiari Ahmad;Parniani Mostafa;Mokhtari Hossein
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.2
    • /
    • pp.153-160
    • /
    • 2006
  • This paper presents a new compensating system, which consists of a shunt active filter and passive components for mitigating voltage and current disturbances arising from an Electric Arc Furnace (EAF). A novel control strategy is presented for the shunt active filter. An extended method based on instantaneous power theory in a rotating reference frame is developed for extraction of compensating signals. Since voltages at the point of common coupling contain low frequency interharmonics, conventional methods cannot be used for dc voltage regulation. Therefore, a new method is introduced for this purpose. The passive components limit the fast variations of load currents and mitigate voltage notching at the Point of Common Coupling (PCC). A three-phase electric arc furnace model is used to show power quality improvement through reactive power and harmonic compensation by a shunt active filter using the proposed control method. The system performance is investigated by simulation, which shows improvement in power quality indices such as flicker severity index.

Customer Nodal Cost Calculation considering Power Quality (전력품질을 고려한 수용가 모선 가격 계산)

  • Jeong, Sung-Won;Park, In-Duck;Gim, Jae-Hyeon;Lee, Geun-Joon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.3
    • /
    • pp.82-87
    • /
    • 2007
  • This paper measures power quality of bus in case electric charges about customer are imposed by each bus, supposed that can calculate this cost. When reflected this in system planning, expected cost proposed following method through sample system. To calculate nodal cost operating condition of power equipment calculates nodal cost[$/MVAH] supposing by situation that is optimized by OPF(optimal power flow) in system. The damage cost that is shed by fault that happen during year of loads in system that is linked on each bus was produced. As a result, proposed method was very effective in case of calculating bus total cost including power quality cost.

A Study on the Detection Algorithm of Voltage Sag using Wavelet Transform (Wavelet 변환을 이용한 voltage sag의 검출기법에 관한 연구)

  • Kim, C.H.;Lee, J.P.;Yeo, S.M.;Kang, Y.S.;Kang, J.S.;Chai, Y.M.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.276-278
    • /
    • 2001
  • In recent years, both electric utilities and end users have expressed their deep concerns about the quality of electric power. Especially, voltage sag which is one of power quality disturbance is very serious power quality problem on the power system. Voltage sag is a decrease to between 0.1 and 0.9 pu in rms voltage magnitude on the power system for durations from 0.5 cycles to 1 minute. These voltage sags are usually caused by fault conditions, overloads, and starting of large motors. The wavelet transform has attracted considerable attention in the field of power quality analysis recently. It has proved to be a powerful tool to study those transients that have time-localized information. In this paper, different types of voltage sags are simulated by using EMTP. This paper proposes the effective technique for voltage sag detection using wavelet transform.

  • PDF

Relationship between residential district and health-related quality of life in Chungnam industrial complex area

  • Kim, Heechan;Roh, Sangchul
    • Environmental Analysis Health and Toxicology
    • /
    • v.31
    • /
    • pp.17.1-17.7
    • /
    • 2016
  • Objectives This study aimed to evaluate the relationship between residential district of people, such as power plant, steel-mill and petrochemical industries, and health-related quality of life (HRQoL). Methods Using a cross-sectional study design, we randomly recruited participants for our study from industrial areas (thermoelectric power plant, steel-mill, petrochemical industry) and rural areas. Logistic regression analysis was used to identify the relationships between Euro quality of life-5 dimension (EQ-5D) scores and living region, while controlling for sociodemographic characteristics. Results In adjusted model, quality of life decreased with increasing category of age and were lower for females than males. EQ-5D scores of people living in the vicinity of thermoelectric power plant were significant lower than those of people living the vicinity of comparison region (odds ratio, 1.59; 95% confidence interval, 1.00 to 2.53). Conclusions Living region of thermoelectric power plant, was strongly associated with scores on the EQ-5D. More research is needed to elucidate the mechanisms which makes the relationship with the living regions and HRQoL.

Fabrication and Evaluation of Digital Signal Processor for Multi-Lane Energy Measurement System (개별 전로 전력 계측을 위한 디지털 신호처리 프로세서 기반 전력 관제 시스템의 제작 및 평가)

  • Kim, Geun-Jun;Kang, Bongsoon
    • Journal of IKEEE
    • /
    • v.22 no.3
    • /
    • pp.619-623
    • /
    • 2018
  • Due to the development of society, the demand for electric power has increased and the quality control of electric power has become an important issue. In order to efficiently perform such power management, we propose a DSP based power measurement system for multi-wire power measurement. Since the conventional power measurement system can measure only the power of one line, a power quality measurement device is required for each line in order to measure the power quality of the individual line. Respectively. The system proposed in this paper proposes a system capable of real-time measurement of power quality at up to 12 points using digital signal processing algorithm, and the prototype based on this system was evaluated through the official test report of Korea Electrotechnology Research Institute. As a result of the performance test, it was evaluated that the error range is excellent at ${\pm}0.3%$.

Power Quality Warning of High-Speed Rail Based on Multi-Features Similarity

  • Bai, Jingjing;Gu, Wei;Yuan, Xiaodong;Li, Qun;Chen, Bing;Wang, Xuchong
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.92-101
    • /
    • 2015
  • As one type of power quality (PQ) disturbance sources, high-speed rail (HSR) can have major impacts on the power supply grid. Providing timely and accurate warning information for PQ problems of HSR is important for the safe and stable operation of traction power supply systems and the power supply grid. This study proposes a novel warning approach to identify PQ problems and provide warning prompts based on the monitored data of HSR. To embody the displacement and status change of monitored data, multi-features of different sliding windows are computed. To reflect the relative importance degree of these features in the overall evaluation, an analytic hierarchy process (AHP) is used to analyse the weights of multi-features. Finally, a multi-features similarity algorithm is applied to analyse the difference between monitored data and the reference data of HSR, and PQ warning results based on dynamic thresholds can be analysed to quantify its severity. Cases studies demonstrate that the proposed approach is effective and feasible, and it has now been applied to an actual PQ monitoring platform.

Power Quality Monitoring with Electronic Watt-hour meter and Wireless communication module (전자식 전력량계와 무선모듈을 이용한 전력품질 표시 및 모니터링)

  • Jung, Deug-Il;Son, Young-Dae
    • Proceedings of the KIEE Conference
    • /
    • 2007.10c
    • /
    • pp.172-174
    • /
    • 2007
  • An electronic watt-hour meter with high-precision measurement technology can provide many valuable metering data of a real-time system measurements, such as per-phase voltage, ampere, active power, reactive power, apparent power, power factor, and system frequency. Also many of accumulated metering data such as active energy, reactive energy, apparent energy, and load profile can be gettable from an electronic watt-hour meter[1]. This paper presents an approach of the small-sized AMR (Automatic Meter Reading) that provides customers with a very valuable electrical service. This AMR service transmits lots of a valuable metering data by using ZigBee communication module, so that users resided in their premises can use the information to audit a power quality and improve their electrical conditions by using the PQ monitoring device equipped with ZigBee receiver. This PQ monitoring device shows metering data on LCD and transmits to the PC through an internal network. Also, the device can keep the valuable meter data into a built-in non-volatile memory. The final goal of this paper is to better understand the power quality of electrical systems and offer the power qualify information for the convenience of all power consumers.

  • PDF

The Power Quality about Wind/Diesel combined power generation in isolated area (고립지역의 풍력/디젤 복합발전 전력품질 특성)

  • Ko, Seok-Whan;Kim, Seok-Woo;Lee, Youn-Seop
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.245-249
    • /
    • 2009
  • Antarctic King Sejong Station was established in King George Island, the South Pole in 1988, and has been executing the monitoring studies on the change of antarctic natural environment. As an available power, the wind energy generator has been used in the form of hybrid with mainly diesel generator. Because the wind generation power sharply changes by wind energy, it must be careful during the system operation. When the power system becomes stable, the output performance of wind energy generator becomes stable. But, in case of unstable system, the errors frequently occur on the wind energy generator and it badly impacts the power system by output of wind energy generator. The purpose of this paper is to analyze suitability while operating the system of 10kW wind energy generator at Antarctic King Sejong Station, an isolated area, and to analyze the problem and improvements by power quality.

  • PDF

Precise Modeling and Adaptive Feed-Forward Decoupling of Unified Power Quality Conditioners

  • Wang, Yingpin;Obwoya, Rubangakene Thomas;Li, Zhibo;Li, Gongjie;Qu, Yi;Shi, Zeyu;Zhang, Feng;Xie, Yunxiang
    • Journal of Power Electronics
    • /
    • v.19 no.2
    • /
    • pp.519-528
    • /
    • 2019
  • The unified power quality conditioner (UPQC) is an effective custom power device that is used at the point of common coupling to protect loads from voltage and current-related PQ issues. Currently, most researchers have studied series unit and parallel unit models and an idealized transformer model. However, the interactions of the series and parallel converters in AC-link are difficult to analyze. This study utilizes an equivalent transformer model to accomplish an electric connection of series and parallel converters in the AC-link and to establishes a precise unified mathematical model of the UPQC. The strong coupling interactions of series and parallel units are analyzed, and they show a remarkable dependence on the excitation impedance of transformers. Afterward, a feed-forward decoupling method based on a unified model that contains the uncertainty components of the load impedance is applied. Thus, this study presents an adaptive method to estimate load impedance. Furthermore, simulation and experimental results verify the accuracy of the proposed modeling and decoupling algorithm.