• Title/Summary/Keyword: power mode transition

Search Result 115, Processing Time 0.029 seconds

Development of submersion sensors using multi-mode fibers spliced with a fiber Bragg grating (다중모드 광섬유 융착형 침수 감지 센서 개발)

  • Sohn, Kyung-Rak;Key, Kwang-Hyun;Shim, Joon-Hwan;Cho, Seok-Je
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.6
    • /
    • pp.925-931
    • /
    • 2009
  • This paper reports a preliminary experimental investigation and characterization of an optical fiber-based submersion sensor system for applications in water flooding and leakage. The sensor system comprises a multi-mode fiber spliced with fiber Bragg grating and an intensity-based interrogator. Submersion tests were conducted in water-air and Glycerin-air environments. By the refractive index of the fiber-probe surrounding materials, the reflectance and the detecting power level is determined. When the probe is dipped into the water, the optical output power dramatically decreases from -7.5dBm to -17.5dBm. But, the center of Bragg wavelength is not affected in spite of external material changes. Temporal response characteristics of the sensor system is investigated to verify the real-time reaction. When the probe is immersed into the liquid, there is no transition time.

A Study on Design and Analysis of Piezoelectric Transformer for Resonance Mode (공진모드의 변화에 따른 압전변압기의 특성에 관한 연구)

  • 정현호;이상기;박태곤;김명호;이원재
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.432-435
    • /
    • 2000
  • This paper present a new sort of multilayer piezoelectric ceramic transformer for the application to AC-adapters. This piezoelectric transformers operate in the second and third length extensional vibration mode. And the output performance of two types of piezoelectric transformers are compared by ANSYS, which is one of the FEM analysis program. As a result the minimum displacement was occurred at the two points in second length extensional vibration mode and three point in third length extensional vibration mode. One is the middle of input and the other is middle of output parts. And output voltage was inversely decreased by increasing number of output layers. Also The third mode type is shown higher power transition ratio than the second mode type.

  • PDF

Control Method of Distributed-Module Type Photovoltaic Power Conditioners under Stand-alone Operation (분산모듈형 태양광 전력조절기의 독립운전 제어)

  • Seo, Jung-Won;Park, Joung-Hu;Kim, Hye-Rim
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.5
    • /
    • pp.448-457
    • /
    • 2013
  • This paper proposes a control method under stand-alone operating mode for distributed-module type photovoltaic power conditioners. In conventional schemes, there are some problems of a controller saturation in the DC-link (or load) voltage controller when overly-heavy load, light load, and the generated PV power reduction occurs, as well as when a transition occurs from an overly-loaded to normal conditions. To overcome these problems, the proposed controller method switches the main control target from DC-link voltage to the maximum power point, which is closer to the stable operating point when it returns to normal operating conditions. For the analysis, a state-plane trajectory was given and the circuit analysis by PSIM simulation was done. For the verification, a prototype hardware with 110[W] and 50[W] dual photovoltaic modules has been implemented. From the results, it can be seen that PV power tracking is successfully done with the proposed method even under a stand-alone operation mode.

ZVT-PWM Amplifier for Audio Applications (소프트 스위칭 기술을 이용한 오디오용 파워앰프)

  • Seo, D.H.;Cho, B.H.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07f
    • /
    • pp.2145-2147
    • /
    • 1998
  • This paper presents a Class-D type switched mode audio power amplifier employing ZVT(Zero-Voltage-Transition) soft switching technique. In order to obtain a wide bandwidth and lower distortion for an audio amplifier a high switching frequency is essential. The ZVT switching scheme enables a high frequency switching without sacrificing the efficiency much as in a hard switching. A prototype amplifier is built to demonstrate the feasibility of this technique for the audio power amplifier.

  • PDF

Transient Air-fuel Ratio Control of the Cylinder Deactivation Engine during Mode Transition (Cylinder Deactivation 엔진의 동작모드 전환 시 과도상태 공연비 제어)

  • Kwon, Min-Su;Lee, Min-Kwang;Kim, Jun-Soo;SunWoo, Myoung-Ho
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.19 no.2
    • /
    • pp.26-34
    • /
    • 2011
  • Hybrid powertrain systems have been developed to improve the fuel efficiency of internal combustion engines. In the case of a parallel hybrid powertrain system, an engine and a motor are directly coupled. Because of the hardware configuration of the parallel hybrid system, friction and the pumping losses of internal combustion engines always exists. Such losses are the primary factors that result in the deterioration of fuel efficiency in the parallel-type hybrid powertrain system. In particular, the engine operates as a power consumption device during the fuel-cut condition. In order to improve the fuel efficiency for the parallel-type hybrid system, cylinder deactivation (CDA) technology was developed. Cylinder deactivation technology can improve fuel efficiency by reducing pumping losses during the fuel-cut driving condition. In a CDA engine, there are two operating modes: a CDA mode and an SI mode according to the vehicle operating condition. However, during the mode change from CDA to SI, a serious fluctuation of the air-fuel ratio can occur without adequate control. In this study, an air-fuel ratio control algorithm during the mode transition from CDA to SI was proposed. The control algorithm was developed based on the mean value CDA engine model. Finally, the performance of the control algorithm was validated by various engine experiments.

A Control Strategy for Flywheel Energy Storage / Recovery System with Induction Machine (유도기를 이용한 플라이휠 에너지 저장 및 재생 시스템 제어 기법)

  • Son Jang-Kyung;Lee Hong-Hee;Nho Eui-Cheol;Kim Heung-Gun;Chun Tae-Won
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.5
    • /
    • pp.494-500
    • /
    • 2005
  • The paper proposed a control strategy for flywheel energy/recovery system with induction machine at the dynamic UPS system using the flywheel stored mechanical energy. The performances for the vector controlled induction generator are compared with those for the induction generator using slip control method. The strategy to improve the transient responses for dc link capacitor voltage is suggested at the transition from the motoring mode to the generating mode. The strategy Proposed by the paper is verified with experiment results using 32bit DSP.

Influence of AC Frequency on the Liquid Breakup in Electrohydrodynamic Atomization (전기수력학적 미립화에서 교류 주파수가 액적 분열에 미치는 영향)

  • Sung, K.A.;Lee, C.S.
    • Journal of ILASS-Korea
    • /
    • v.9 no.2
    • /
    • pp.41-49
    • /
    • 2004
  • Liquid breakup under the variation of AC frequency has been studied experimentally in the electrohydrodynamic atomization. The effect of parameters such as charging voltage, flow rate, nozzle tip inner diameter and power frequency have been considered. This work was performed to investigate the experimental analysis for the effect of AC frequency on breakup process, the mapping of occurrence of disintegration region, and the relationship between the applied power and the droplet radius. The experimental results show that the increase of applied voltage in a certain frequency band leads to a reduction in the droplet size within the limits from 50Hz to 400Hz. The transition phenomena from dripping mode to spindle mode were observed under the band of sudden fall of droplet radius changing ratio, and the synchronous region were produced within the range of applied voltage from 5kV to 6kV.

  • PDF

Proposal and Design of a Novel SNA Protocol for the Power Control System (전력제어 시스템을 위한 SNA 프로토콜 제안 및 설계)

  • Park, Min-Ji;Lee, Dong-Min;Min, Sang-Won
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.8B
    • /
    • pp.1122-1128
    • /
    • 2010
  • In this paper, we proposed and designed a novel SNA protocol which operates in the way of a server and a client in the power control system. The proposed SNA protocol includes the information about the mode switching, the saving position of context information, the user trigger, and so forth, which are needed in the power management devices. We consider the application of the SNA protocol to the home network, where message flows between the SNA server and the SNA client. To verify the operation of the SNA protocol, the state transition diagrams of the server in the home gateway and the client in the network device are shown. Hence, we can conclude the SNA can operate without malfuction.

An experimental study of a circular cylinder's two-degree-of-freedom motion induced by vortex

  • Kim, Shin-Woong;Lee, Seung-Jae;Park, Cheol-Young;Kang, Donghoon
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.8 no.4
    • /
    • pp.330-343
    • /
    • 2016
  • This paper presents results of an experimental investigation of vortex-induced vibration (VIV) of a flexibly mounted and rigid cylinder with two-degrees-of-freedom with respect to varying ratio of in-line natural frequency to cross-flow natural frequency, $f^*$, at a fixed low mass ratio. Combined in-line and cross-flow motion was observed in a sub-critical Reynolds number range. Three-dimensional displacement meter and tension meter were used to measure dynamic responses of the model. To validate the results and the experiment system, x and y response amplitudes and ratio of oscillation frequency to cross-flow natural frequency were compared with other experimental results. It has been found that the higher harmonics, such as third and more vibration components, can occur on a certain part of steel catenary riser under a condition of dual resonance mode. In the present work, however, due to the limitation of a size of circulating water channel, the whole test of a whole configuration of the riser at an adequate scale for VIV phenomenon was not able to be conducted. Instead, we have modeled a rigid cylinder and assumed that the cylinder is a part of steel catenary riser where the higher harmonic motions could occur. Through the experiment, we have found that even though the cylinder was assumed to be rigid, the occurrence of the higher harmonic motions was observed in a small reduced velocity ($V_r$) range, where the influence of the in-line response is relatively large. The transition of the vortex shedding mode from one to another was examined by using time history of x and y directional displacement over all experimental cases. We also observed the influence of in-line restoring force power spectral density with $f^*$.

Common-mode Voltage Reduction of Three Level Four Leg PWM Converter (3레벨 4레그 PWM 컨버터의 커먼 모드 전압 저감)

  • Chee, Seung-Jun;Ko, Sanggi;Kim, Hyeon-Sik;Sul, Seung-Ki
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.6
    • /
    • pp.488-493
    • /
    • 2014
  • This paper presents a carrier-based pulse-width modulation(PWM) method for reducing the common-mode voltage of a three-level four-leg converter. The idea of the proposed PWM method is intuitive and easy to be implemented in digital signal processor-based converter control systems. On the basis of the analysis of space-vector PWM(SVPWM) and sinusoidal PWM(SPWM) switching patterns, the fourth leg pole voltage of the three-phase converter called "f leg pole voltage" is manipulated to reduce the common-mode voltage. To synthesize f leg pole voltage for the suppression of the common-mode voltage, positive and negative pole voltage references of f leg are calculated. An offset voltage is also deduced to prevent the distortion of a, b, and c phase voltages. The feasibility of the proposed PWM method is verified by simulation and experimental results. The common-mode voltage of the proposed PWM method in peak-to-peak value is 33% in comparison with that of the conventional SVPWM method. The transition number of the common-mode voltage is also reduced to 25%.