• Title/Summary/Keyword: power measure

Search Result 2,241, Processing Time 0.027 seconds

Implementation of the 60W DC Characteristic Measurement System for Semiconductor Devices (60W 출력을 가지는 반도체 소자의 직류 특성 측정시스템의 구현)

  • Choi, In-Kyu; Choi, Chang;Han, Hye-Jin;Park, Jong-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2001.11c
    • /
    • pp.34-37
    • /
    • 2001
  • In this paper, we designed and implemented the 60W DC characteristic measurement system for semiconductor devices. The proposed system is composed of 2 SMU(Source and Measure Unit)s, 2 HPU(High power Unit)s, 2VSU(Voltage Source Unit)s, and 2 VMU(Voltage Measurement Unit)s. HPU can source/measure voltage from -200V to 200V and source/measure current from -3A to 3A within 60W. Experimental results show that the implemented system can measure the power devices such as power BJT, regulator IC, and voltage detector.

  • PDF

A web-based power quality monitoring system in the Substation Automation System (변전소 자동화 환경에서 웹 기반 전기품질 감시 시스템)

  • Park D. H.;Lim S. J.;Shin J. H.;Lim S. I.;Lee S. J.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.378-380
    • /
    • 2004
  • Along with the increase of the importance of power quality, many various systems are dedicated in the analysis of power quality nowadays. But there still exists the same problems for realizing such kind of analysis systems well. One is the customization of the power quality measure devices; The other is an economic problem. This paper presents the usefulness and the advantage of the ICD (Intelligent Electronic Device) as the measure device of power quality And this paper detailedly describes the development procedure of web-based power quality monitoring system through ActiveX controls. Now this power quality monitoring system is already applied to the substation automation system.

  • PDF

Fault Diagnosis of Power Transformer by FCM and Euclidean Based Distance Measure (FCM과 유클리디언 기반 거리유사도에 의한 전력용 변압기의 고장진단)

  • Lee, Dae-Jong;Lee, Jong-Pil;Ji, Pyeong-Shik;Lim, Jae-Yoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.6
    • /
    • pp.1007-1016
    • /
    • 2007
  • In power system, substation facilities have become too complex and larger according to an extended power system. Also, customers require the high quality of electrical power system. However, some facilities become old and often break down unexpectedly. The unexpected failure may cause a break in power system and loss of profits. Therefore it is important to prevent abrupt faults by monitoring the condition of power systems. Among the various power facilities, power transformers play an important role in the transmission and distribution systems. In this research, we develop intelligent diagnosis technique for predicting faults of power transformer by FCM(Fuzzy c-means) and Euclidean based distance measure. The proposed technique make it possible to measures the possibility and degree of aging as well as the faults occurred in transformer. To demonstrate the validity of proposed method, various experiments are performed and their results are presented.

Application of Similarity Measure for Fuzzy C-Means Clustering to Power System Management

  • Park, Dong-Hyuk;Ryu, Soo-Rok;Park, Hyun-Jeong;Lee, Sang-H.
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.8 no.1
    • /
    • pp.18-23
    • /
    • 2008
  • A FCM with locational price and regional information between locations are proposed in this paper. Any point in a networked system has its own values indicating the physical characteristics of that networked system and regional information at the same time. The similarity measure used for FCM in this paper is defined through the system-wide characteristic values at each point. To avoid the grouping of geometrically distant locations with similar measures, the locational information are properly considered and incorporated in the proposed similarity measure. We have verified that the proposed measure has produced proper classification of a networked system, followed by an example of a networked electricity system.

A Study on the High-Accuracy Power Meter and Reliability Verification Plan (고정밀 전력미터의 개발과 신뢰성 확보 방안에 대한 연구)

  • Lee, Sanghun;LEE, Changhwa
    • Journal of Korea Multimedia Society
    • /
    • v.20 no.7
    • /
    • pp.1046-1053
    • /
    • 2017
  • We propose a design method of high accuracy power measuring device and the method of securing the reliability of the measured data. As a design method for the development of the high accuracy power measuring device, the circuit was made by reflecting the high accuracy power measuring ICs and the CT (Current Transformer). To ensure the reliability of the power meter, we requested to the watt-hour meter certified testing organization to measure the error rate, and the error rate of active power based on the "Wattmeter Technical Standard(Revision notify 2014-283)" was measure, and the error rate was confirmed to be less than 0.1%.

The Effect of a Taping on Muscle Strength, and Proprioception in Ankle (테이핑에 따른 발목 근력, 고유수용성감각에 미치는 영향)

  • Lee, Sang-Young
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.3 no.4
    • /
    • pp.225-233
    • /
    • 2008
  • Purpose : The purpose of this study was to investigate changes of muscle strength, ROM and proprioceptive function as before & after ankle taping in soccer players. For this study fifteen sports club whose had no ankle injuries were volunteered. Methode : Fifteen healthy male in soccer players participated in this study. Biodex pro system3 was used to measure isokinetic muscle strengths at $60^{\circ}$/sec angular velocity. Performances of ankle joint were measured peak torque, total work, average power, total work. To measure proprioceptive function used goniometer. Results : 1. proprioceptive sensation error were significantly differences by before & after taping(p<.05). 2. Compare of total work of dorsi flexion plantar flexion weren't significantly differences by before & after taping(p>.05). 3. Compare of average power of dorsi flexion weren't significantly differences by before & after taping(p>.05). 4. Compare average power of plantar flexion were significantly differences by before & after taping(p<.05). 5. Compare average peak torque of dorsi flexion weren't significantly differences by before & after taping(p>.05). 6. Compare average peak torque of plantar flexion were significantly differences by before & after taping(p<.05). Conclusion : Taping can have propriocetive aberrative angular measure, power & peak torque of plantar flexion were significantly differences. But, total work of dorsi flexion plantar flexion and power & peak torque of dorsi flexion weren't significantly differences.

  • PDF

FFT analysis of load data during field operations using a 75-kW agricultural tractor

  • Ryu, Myong-Jin;Chung, Sun-Ok;Kim, Yong-Joo;Lee, Dae-Hyun;Choi, Chang-Hyun;Lee, Kyeong-Hwan
    • Korean Journal of Agricultural Science
    • /
    • v.40 no.1
    • /
    • pp.53-59
    • /
    • 2013
  • Analysis of load data during field operations is highly important for optimum design of power drive lines for agricultural tractor. Objective of the paper was to analyze field load data using FFT to determine frequency and the energy levels of meaningful cyclic patterns. Rotary tillage, plowing, baling, and wrapping operations were selected as major field operations of agricultural tractor. An agricultural tractor with power measurement system was used. The tractor was equipped with strain-gauge sensors to measure torque of four driving axles and a PTO axle, speed sensors to measure rotational speed of the driving axles and an engine shaft, pressure sensors to measure pressure of hydraulic pumps, an I/O interface to acquire the sensor signals, and an embedded system to calculate power requirement. In rotary tillage, calculated frequency was decreased as travel speed increased. In baler operation, calculated frequency was increased as PTO speed was increased. The calculated peak frequency levels and expected levels were similar. Results of the study would provide information on power utilization patterns and on better design of power drive lines.

Bayesian Model Selection in the Unbalanced Random Effect Model

  • Kim, Dal-Ho;Kang, Sang-Gil;Lee, Woo-Dong
    • Journal of the Korean Data and Information Science Society
    • /
    • v.15 no.4
    • /
    • pp.743-752
    • /
    • 2004
  • In this paper, we develop the Bayesian model selection procedure using the reference prior for comparing two nested model such as the independent and intraclass models using the distance or divergence between the two as the basis of comparison. A suitable criterion for this is the power divergence measure as introduced by Cressie and Read(1984). Such a measure includes the Kullback -Liebler divergence measures and the Hellinger divergence measure as special cases. For this problem, the power divergence measure turns out to be a function solely of $\rho$, the intraclass correlation coefficient. Also, this function is convex, and the minimum is attained at $\rho=0$. We use reference prior for $\rho$. Due to the duality between hypothesis tests and set estimation, the hypothesis testing problem can also be solved by solving a corresponding set estimation problem. The present paper develops Bayesian method based on the Kullback-Liebler and Hellinger divergence measures, rejecting $H_0:\rho=0$ when the specified divergence measure exceeds some number d. This number d is so chosen that the resulting credible interval for the divergence measure has specified coverage probability $1-{\alpha}$. The length of such an interval is compared with the equal two-tailed credible interval and the HPD credible interval for $\rho$ with the same coverage probability which can also be inverted into acceptance regions of $H_0:\rho=0$. Example is considered where the HPD interval based on the one-at- a-time reference prior turns out to be the shortest credible interval having the same coverage probability.

  • PDF

Power Quality Disturbances Detection Technique using Filter Bank and Adaptive Filters (필터뱅크와 적응필터를 이용한 전력품질 외란 검출기법)

  • Yun, Jae-Jun;Lee, Jeong-Kyu;Sohn, Sang-Wook;Bae, Hyeon-Deok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.1
    • /
    • pp.162-167
    • /
    • 2012
  • In power quality monitoring, it is very important to detect disturbances (sag, swell, transient, and interruption) accurately. In this paper, a detection method for power quality disturbances by combining the filter bank system and adaptive filter is proposed. To decompose power signal, binary tree structured filter bank system is designed. In the filter bank system, the fundamental filter bank(QMF bank) is used as a module in each decomposing level. An adaptive filter is used to improve the detection accuracy of disturbances for each subband signal. In the adaptive filter, the measure of estimated error change is used to detect singular points of power quality disturbances. Computer simulations were performed on synthetic signals which have disturbances to assess the performance of the proposed method.