• Title/Summary/Keyword: power line signal

Search Result 642, Processing Time 0.027 seconds

Implementation of the ECG Monitoring System for Home Health Care Using Wiener Filtering Method (Wiener Filtering 기법을 적용한 홈헬스케어용 심전도 신호 모니터링 시스템 구현)

  • Jeong, Do-Un;Kim, Se-Jin
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.9 no.2
    • /
    • pp.104-111
    • /
    • 2008
  • The ECG is biomedical electrical signal occurring on the surface of the body due to the contraction and relaxation of the heart. This signal represents an extremely important measure for health monitoring, as it provides vital information about a patient's cardiac condition and general health. ECG signals are contaminated with high frequency noise such as power line interference, muscle artifact and low frequency nose such as motion artifact. But it is difficult to filter nose from ECG signal, and errors resulting from filtering can distort a ECG signal. The present study implemented a small-size and low-power ECG measurement system that can remove motion artifact for convenient health monitoring during daily life. The implemented ECG monitoring system consists of ECG amplifier, a low power microprocessor, bluetooth module and monitoring program. Amplifier was designed and implemented using low power instrumentation amplifier, and microprocessor was interfaced to the ECG amplifier to collect the data, process, store and feed to a transmitter. And bluetooth module used to wirelessly transmit and receive the vital sign data from the microprocessor to an PC at the receiving site. In order to evaluate the performance of the implemented system, we assessed motion artifact rejection performance in each situation with artificially set condition using adaptive filter.

  • PDF

Power-Space Functions in High Speed Railway Wireless Communications

  • Dong, Yunquan;Zhang, Chenshuang;Fan, Pingyi;Fan, Pingzhi
    • Journal of Communications and Networks
    • /
    • v.17 no.3
    • /
    • pp.231-240
    • /
    • 2015
  • To facilitate the base station planning in high speed railway communication systems, it is necessary to consider the functional relationships between the base station transmit power and space parameters such as train velocity and cell radius. Since these functions are able to present some inherent system properties determined by its spatial topology, they will be referred to as the power-space functions in this paper. In light of the fact that the line-of-sight path persists the most power of the received signal of each passing train, this paper considers the average transmission rate and bounds on power-space functions based on the additive white Gaussian noise channel (AWGN) model. As shown by Monte Carlo simulations, using AWGN channel instead of Rician channel introduces very small approximation errors, but a tractable mathematical framework and insightful results. Particularly, lower bounds and upper bounds on the average transmission rate, as well as transmit power as functions of train velocity and cell radius are presented in this paper. It is also proved that to maintain a fixed amount of service or a fixed average transmission rate, the transmit power of a base station needs to be increased exponentially, if the train velocity or cell radius is increased, respectively.

Compensation of Chromatic Dispersion and Self Phase Modulation in Long-haul Optical Transmission System using Mid-span Optical Phase Conjugator (Mid-span Optical Phase Conjugator를 이용한 장거리 광 전송 시스템에서의 색 분산과 자기 위상 변조의 보상에 관한 연구)

  • 이성렬;이윤현
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.4
    • /
    • pp.576-585
    • /
    • 2001
  • In this paper, we investigated the method of compensation for optical pulse shape distortion due to both chromatic dispersion and SPM(self phase modulation) in a single mode fiber We selected MSSI(mid-span spectral inversion) as compensation method using OPC(optical phase conjugator). We used EOP(eye-opening penalty) parameter in order to evaluate the efficiency of waveform distortion compensation. In this paper, we induced optimum pump power level in optical phase conjugator through analytic method of computer simulation. And we investigated input signal power range being able to maintain stable reception performance under the condition of optimum pump power. We verified the possibility of high performance optical transmission system realization through the inducement and application of optimum pump power, input signal power and in-line amplifier spacing, because power control is important in the compensation for optical pulse distortion.

  • PDF

Design and Realization UHF Power Amplifier for Air Traffic Control (항공교통관제용 UHF대역 전력 증폭기 설계 및 구현)

  • Kang, Suk-Youb;Song, Byoung-Jin;Park, Wook-Ki;Go, Min-Ho;Park, Hyo-Dal
    • Journal of Advanced Navigation Technology
    • /
    • v.10 no.2
    • /
    • pp.167-172
    • /
    • 2006
  • In this paper, the 25W power amplifier for UHF band radio transceiver has been designed and realized. The power amplifier was composed of drive, power amplifier and control stages. Feedback topology and coaxial line baluns were used for wide band operation. The VDMOS, which has reliable performance for linearity and efficiency, was used for power device and designed to operate as push-pull amplification at Class AB Bias. The power amplifier designed in such a way was found to show stable AM modulation performance when voice signal was detected at the gate stage, with being designed and realized to meet output specifications of commercial air traffic control transmitter.

  • PDF

The Realization of a Transmission Line Protection IED based on IEC61850 (IEC61850 기반 송전선 보호 IED 구현)

  • Kim, Cheol-Hun;Kwon, Young-Jin;Lee, Dong-Gyu;Ryu, Ki-Chan;Kang, Sang-Hee;Nam, Soon-Ryul
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.6-8
    • /
    • 2006
  • 변전소 자동화 시스템에서 IED(Intelligent Electronic Device)들 간의 효과적인 통신을 위해 표준프로토콜인 IEC-61850이 제시되면서 이를 구현하고 응용하기 위한 관심이 높아지고 있다. 본 논문은 IEC-61850 표준규격을 분석하여 제시된, 거리 계전 IED 모델을 이용해 송전선 보호 IED를 구현하였다. 통신기능 구현은 리눅스 커널 2.6 기반의 통신보드를 사용하였고 계전 알고리즘의 수행은 TMS320C32 기반의 DSP(Digital Signal Processor) 보드를 사용하였다. 보드간 통신은 CAN(Cont roller Area Network) 통신으로 이루어 졌으며 사례연구를 위해 RTDS(Real Time Digital Power System Simulator)를 이용하여 입력신호를 생성하였다. 구성된 시스템의 검증을 위해 거리계전기에서 후비보호 시 발생할 수 있는 문제점을 시뮬레이션 하였다.

  • PDF

Application and Control of UPFC for Improving Power System Oscillation Damping (전력시스템 동요억제를 위한 UPFC 적용 및 제어)

  • Kim, Y.S.;Kim, T.J.;Lee, B.H.;Han, H.G.;Son, K.M.;Park, J.K.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07c
    • /
    • pp.1124-1126
    • /
    • 1997
  • The Unified Power Flow Controller(UPFC) with a series inverter and a shunt inverter ia able to control all three line Parameters(voltage, impedance and phase angle) and so UPFC technology has the potential to enhance the implementation and broad application of the FACTS concept with improved Performance. In this Paper, the UPFC is applied in order to improve the power flow oscillation damping. The modal performance measure is minimized in order to determine the optimal parameters of UPFC controller for damping Power flow oscillations. The dynamics of the injected voltage of UPFC is represented as a first order delay element. The UPFC controller used here is of the PIO type and the input signal to the controller is the active power flow through the UPFC. The effect of UPFC application to the Power system are analyzed from the stand point of power system oscillation damping.

  • PDF

Stabilization Converter Design and Modeling of LEO Satellite Power Systems (저궤도 위성의 전력 시스템 안정화를 위한 모델링 및 제어)

  • Yun, Seok-Teak;Won, Young-Jin;Lee, Jin-Ho
    • Journal of Satellite, Information and Communications
    • /
    • v.5 no.2
    • /
    • pp.29-33
    • /
    • 2010
  • Satellites industry has been developing with the commercial and military needs. Because power system of satellite is very important to survival operation and hard to test, increasing reliability is very critical. Due to LEO small satellites are very sensitive to power system, effective stabilization control is important. Therefore, this paper introduce methods for general modeling of power converting system which it can be used design of controller and analysis of external disturbance influences. In conclusion, a modeling of LEO small satellites power converting system and a possible guide line to design reliable controller which optimizing power converters of LEO small satellite are generated.

Modified Transmission Line Protection Scheme in the Presence of SCC

  • Naeini, Ehsan Mostaghimi;Vaseghi, Behrouz;Mahdavian, Mehdi
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.533-540
    • /
    • 2017
  • Distance relay identifies the type and location of fault by measuring the transmission line impedance. However any other factors that cause miss calculating the measured impedance, makes the relay detect the fault in incorrect location or do not detect the fault at all. One of the important factors which directly changes the measured impedance by the relay is series capacitive compensation (SCC). Another factor that changes the calculated impedance by distance relay is fault resistance. This paper provides a method based on the combination of distance and differential protection. At first, faulty transmission line is detected according to the current data of buses. After that the fault location is calculated using the proposed algorithm on the transmission line. This algorithm is based on active power calculation of the buses. Fault resistance is calculated from the active powers and its effect will be deducted from calculated impedance by the algorithm. This method measures the voltage across SCC by phasor measurement units (PMUs) and transmits them to the relay location via communication channels. The transmitted signals are utilized to modify the voltage signal which is measured by the relay. Different operating modes of SCC and as well as different faults such as phase-to-phase and phase-to-ground faults are examined by simulations.

Monitoring observation of PG0934+013 using The Southern African Large Telescope

  • Park, Dawoo;Woo, Jong-Hak;Romero-Colmenero, Encarni;Crawford, Steven M.;Barth, Aaron J.;Pei, Liuyi
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.2
    • /
    • pp.54-54
    • /
    • 2013
  • We performed spectroscopic and photometric monitoring observations of a QSO, PG0934+013 for a reverberation-mapping analysis, using the 9-m Southern African Large Telescope (SALT) for spectroscopy and the 2-m Faulkes Telescope North and the South for photometry. The monitoring campaign was carried out for 5 month between December 2012 to April 2013, providing 20 spectroscopic epochs and ~40 photometric epochs. Based on the obtained spectra, which typically have a signal-to-noise ratio to 30-60, we performed multicomponent decomposition using various components, i.e., power-law continuum, FeII emission complex, and broad and narrow emission lines, to properly measure the Hbeta line flux. After a flux normalization using [O III] 5007 line luminosity, we obtained a rms spectrum from all epochs, which shows clear variability of Hbeta line. We find that Hbeta line flux decreases by ~20% during the monitoring period while the continuum flux obtained from the aperture photometry based on the imaging data, shows similar variability. The current Hbeta light curve shows monotonic decrease and a reliable cross correlation analysis between Hbeta and continuum light is difficult. Nevertheless, we obtained a preliminary lag measurements as ~24 light days.

  • PDF

An Experimental Study on Static Characteristics of Servo Valves using Transmission Line Pressures (배관 압력을 이용한 서보밸브 정적 특성에 관한 실험적 연구)

  • Kim, Sung Dong;Joo, Byeol Jin;Yun, So Nam
    • Journal of Drive and Control
    • /
    • v.13 no.2
    • /
    • pp.42-50
    • /
    • 2016
  • The conventional technique to measure the hysteresis and the null of servo valves is defined in ISO 10770-1 and based on load flow signal of the servo valve. A new technique based on the transmission line pressures is suggested in this study. The new measuring method was verified through a series of experiments. No hysteresis was observed between the spool displacement and the transmission line pressures, load pressure or each chamber pressure. Some hysteresis was observed between valve input and pressures, which was found to be the same as those of load flow and spool displacement for the valve input. By using the chamber pressures, the hysteresis and the null are easier to measure than the load pressure or differential pressure between those two chamber pressures because the chamber pressures showed sharp edges.