• Title/Summary/Keyword: power line signal

Search Result 641, Processing Time 0.03 seconds

Power Disturbance Detection using the Inflection Point Estimation (변곡점 추정을 이용한 전력선 신호의 이상현상 검출)

  • Iem, Byeong-Gwan
    • Journal of IKEEE
    • /
    • v.25 no.4
    • /
    • pp.710-715
    • /
    • 2021
  • Power line signal can show disturbances due to various causes. Typical anomalies are temporary sag/swell of the amplitude, flat topped signal, and harmonic distortions. The disturbances need to be detected and treated properly for the quality of the power signal. In this study, the power disturbances are detected using the inflection points (IP). The inflection points are defined as points where local maxima/minima or the slope changes occur. The power line signal has a fixed IP pattern since it is basically sinusoidal, and it may have additional inflection points if there is any disturbance. The disturbance is detected by comparing the IP patterns between the normal signal and distorted signal. In addition, by defining a cost function, the time instant where the disturbance happens can be decided. The computer simulation shows that the proposed method is useful for the detection of various disturbances. The simple sag or swell signal only shows the amplitude changes at the detected inflection points. However, the flat top signal and harmonically distorted signal produce additional inflection points and large values in the cost function. These results can be exploited for the further processing of disturbance classification.

A Study on the development of Heating Facility Control and Remote Control System using Power Line Communication (PLC) (전력선 통신(PLC)을 이용한 난방기기 제어 및 원격제어 시스템의 개발에 관한 연구)

  • Kim, Yong-Tae;Shin, Kwan-Woo;Lee, Youn-Seop
    • Proceedings of the KIEE Conference
    • /
    • 2001.11c
    • /
    • pp.65-67
    • /
    • 2001
  • PLC (Power Line Communication) is the communication method using the existing power line installed in houses and offices to convert and transmit high frequency communication signal from tens of KHz to tens of MHz, and receive the filtered signal using high frequency filter. The advantage of PLC is that PLC uses the existing power line installed in houses and offices so it does not require separate power line. Easy and convenient access using electric outlets is another advantage of PLC. However, PLC has some disadvantages such as limited transmission power, high load interference and noise, variable signal attenuation, characteristic of impedance selective possibility of frequency property. This study designed the boiler temperature control system by unit using the modem designed on the basis of technology used for PLC modem, and designed remote control system using internet. After conducting experiments with those two systems, it was possible to control stably. By commercializing this product, we can avoid unnecessary heating of separate temperature control unit, and save the cost according1y, and it is possible to control on a remote site using internet in a more convenient way.

  • PDF

Power Amplifier Design using λ/4 DGS(Defected Ground Structure) Bias Line (λ/4 DGS 바이어스 선로를 이용한 전력증폭기 설계)

  • 정시균;정용채
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.9
    • /
    • pp.924-931
    • /
    • 2002
  • In this paper, a new λ/4 bias transmission line that is added dumbbell-shaped defected ground structure(DGS) on ground plane of the conventional λ/4 bias transmission line is proposed. This DGS λ/4 bias transmission line maintains high characteristic impedance, but physical width is wider and length is shorter than that of the conventional bias line. If the proposed bias line is attached on signal transmission line, this bias line can reduces the $3^{rd}$ harmonic signal as well as the$2^{nd}$ harmonic signal. With harmonic reduction characteristics, efficiency and linearity of amplifier are improved. The proposed bias line is adopted in power amplifier on IMT-2000 base-station transmitting band. This paper presents several simulations and experimental results of DGS to show validity of the proposed power amplifier using the new λ/4 bias transmission line. Experimental results represent that the $3^{rd}$ harmonic signal is reduced about 26.5 dB and efficiency is improved about 9.1 % and IMD3 is improved 4.5 dB than the conventional structure.

The Characteristic of Data Transmission for Power Line Communication using an AC Arrester for Electric Railway (전철 피뢰기를 이용한 전력선 통신 데이터 전송 특성)

  • Kim, Jae-Moon;Ahn, Seung-Ho;Kim, Yang-Su;Kim, Chul-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.3
    • /
    • pp.497-502
    • /
    • 2012
  • Power line communication(PLC) is a kind of communication technology, was made use of controling a frequency narrow band, but as the PLC technology developing, in the near future get to the commercial step that is broadband PLC upto 30 MHz. This paper deals with the PLC of electric railway using capacitive signal coupler. An AC arrester for catenary is used as a capacitive signal coupler, has the characteristic of capacitor. As a result of field test, a messenger wire used PLC contain much of conducted noise about overall frequency band and also signal attenuation rate increased with increasing frequency between two points. and the communication speed of PLC used messenger wire is 793kbps at a distance of 40m. Experimental results show the possibility of PLC using a messenger wire and an AC arrester for catenary at electric railway.

Flashover Prediction of Polymeric Insulators Using PD Signal Time-Frequency Analysis and BPA Neural Network Technique

  • Narayanan, V. Jayaprakash;Karthik, B.;Chandrasekar, S.
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.4
    • /
    • pp.1375-1384
    • /
    • 2014
  • Flashover of power transmission line insulators is a major threat to the reliable operation of power system. This paper deals with the flashover prediction of polymeric insulators used in power transmission line applications using the novel condition monitoring technique developed by PD signal time-frequency map and neural network technique. Laboratory experiments on polymeric insulators were carried out as per IEC 60507 under AC voltage, at different humidity and contamination levels using NaCl as a contaminant. Partial discharge signals were acquired using advanced ultra wide band detection system. Salient features from the Time-Frequency map and PRPD pattern at different pollution levels were extracted. The flashover prediction of polymeric insulators was automated using artificial neural network (ANN) with back propagation algorithm (BPA). From the results, it can be speculated that PD signal feature extraction along with back propagation classification is a well suited technique to predict flashover of polymeric insulators.

A study for chirp signal method & system implementation in the PLC modem with low speed (저속 PLC 모뎀에서의 Chirp 신호 방식과 시스템 구현에 관한 연구)

  • Jeong, Young-Hwa;Sang-Gun Lee
    • The Journal of Information Technology
    • /
    • v.7 no.3
    • /
    • pp.37-45
    • /
    • 2004
  • The representative communication method which is applied in the low-speed power line communication modem with 60bps is single carrier method. It has been used mainly for the control. The single carrier method is very sensitive to a power line communication channel environment. Specially, the severe attenuation of the transmission signal according to the notch characteristics of channel becomes the main cause of communication error. Domestic power line channel environment has this notable feature. In this paper, we implemented the low-speed power line communication system which used the chirp signal method to be strong in notch and noise characteristics. In this research, we proposed the method which transmits 1- '1 Unit symbol Chirp signal' with a 100${\mu}s$ time within 1ms for 1 bit. Also it applied for the Convolution code for an error correction and the Manchester code for a collision perception and an error detection. It used the method which uses the bit correlator for signal detection in the receiver parts. We confirmed that the communication method of the chirp method has a excellent performance compared to single carrier methods with a result of experiment of the low-speed power line communication system with the 60bps.

  • PDF

Development of a Monitoring Equipment of Current and Potential on Power Transmission Line for 66kV

  • Nisiyama, Eiji;Kuwanami, Kenshi;Kawano, Mitsunori;Matsuda, Toyonori;Oota, I.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.41-44
    • /
    • 2003
  • We propose portable equipment that monitors current and voltage of high-potential power transmission lines. In the equipment, a current and voltage sensor are attached to an insulator that supports a power transmission line: A clamped to the power line and the detected current signal is transmitted to the ground station by a wireless optical link using transmission line is detected by a high resistance element, zinc oxide (ZnO). That acts as a potential divider between the power line and ground. We make an experimental device for 66kV power line and demonstrate that it can monitor currents proposed equipment is small-sized, light, and inexpensive in comparison with the conventional CT (current transformer) and PT (potential transformer) since it does not require high potential insulators and magnetic cores, further, the equipment is easily installed owing to its small size and its simple structure.

  • PDF

Implementation of Dual Voltage Level DC Power Line Communication Driver for Multiple Access Serial Bidirectional Communication (양방향 다중직렬통신을 위한 이중전압 직류 전력선 통신 드라이버 구현)

  • Han, Kyong-Ho;Hwang, Ha-Yoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.10
    • /
    • pp.29-35
    • /
    • 2009
  • This paper handles, implementation of multiple access bidirectional serial communications protocol using DC power lines. The normal voltage of the power communication line maintains 24[V] corresponding to level 1 and the host drops the voltage to 12[V] on sending level 0 signal, also the clients normally keeps the line voltage to 24[V] use pull-down circuit to drop the voltage to 12[V] on sending level 1 signal. Host senses the voltage level of the power communication lines and the hosts switches power source from 24[V] to 12[V]. Experimental circuit is designed with one hosts and four clients and verified the power line voltage switching operation depending on the data signal levels on the power line.

Dimming Control Signal Transmisson of Electronic Ballast on the Power Line and Characteristics Measurement (전력선을 이용한 전자식 안정기 조광 신호 전송과 특성 측정)

  • 이상곤;정은택;강복연;양병렬;유홍균
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.19 no.4
    • /
    • pp.691-700
    • /
    • 1994
  • A power line in not so good in characteristics for communication, because it is a media to transfer the commercial electrical power, and its load noise and high frequency noise are so much. Thus, a simple method to transfer a remote control signal on the power line is studied. The already-existing method is that two signals with upper part eliminated is transmitted every N step. But the method is investigated which the transmitter sends a period signal eliminated in arbitrary phase. Thus the transmission power loss due to elimination of signal can be reduced to the minimum. To implement it, a timer calculating the time from zero-crossing point to the phase is required. The micro-controller, 87C51, precisely calculates the phase using one of two built-in timers. As a result, a remote control signal tramsmitter and receiver using a partially eliminated signal, which is better than the conventional technique using half-eliminated signal in a efficiency of power transmission, is realized, and its characteristics are analyzed.

  • PDF

Power Line Channel Model Considering Adjacent Nodes with Reduced Calculation Complexity due to Multipath Signal Propagation and Network Size Using Infinite Geometric Series and Matrices (무한 등비급수와 행렬을 이용하여 멀티 패스 신호 전송과 네트워크 크기에 의한 계산의 복잡성을 줄이고 근접 노드의 영향을 고려한 전력선 통신 채널 모델)

  • Shin, Jae-Young;Jeong, Ji-Chai
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.2
    • /
    • pp.248-255
    • /
    • 2009
  • We proposed a power line channel model. We adopted advantages of other power line channel models to calculate channel responses correctly and simply. Infinite geometric series reduced the calculation complexity of the multipath signal propagation. Description Matrices were also adopted to handle the network topology easily. It represents complex power line network precisely and simply. Newly proposed model considered the effect of the adjacent nodes to channel responses, which have been not considered so far. Several simulations were executed to verify the effect of the adjacent nodes. As a result we found out that it affected channel responses but its effect was limited within certain degree.