• Title/Summary/Keyword: power line signal

Search Result 641, Processing Time 0.028 seconds

Study on Short-range Non-line-of-sight Ultraviolet Communication (근거리의 자외선 비가시거리 통신에 관한 연구)

  • Park, Dong-Kook
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.1
    • /
    • pp.179-184
    • /
    • 2012
  • A conventional wireless rf communication has relatively high ratio of power dissipation to transmit power for short-range links, susceptibility to interference, interception and jamming of electromagnetic wave. The study on alternative using ultraviolet signal to remedy the shortcomings of conventional rf communication has recently received attention. In this paper, the simulation results about the data rate performance of ultraviolet non-line-of-sight communication are provided. It is found that the direction of transmitting beam, receiving field of view width and the transmitting signal power have a seriously effect on the data rate of on-off-keying non-line-of-sight ultraviolet communication.

Comparison of Signal Powers Generated with Different Shapes of Hammer Plates

  • Jeong, Ji-Hyun;Kim, Jin-Hoo
    • Journal of the Korean earth science society
    • /
    • v.33 no.5
    • /
    • pp.395-400
    • /
    • 2012
  • One of the main problems concerning the shallow seismic survey is how to generate high frequency signals with large amplitudes using small seismic sources. If one could focus the seismic energy in the direction of the survey line, it will be much helpful in identifying the first break. In this research, we have used hammer as an impulsive source and compared the signal powers generated by different shapes of the hammer plates: circular, square, and rectangular. The experiment was conducted by calculating the power spectral density function to compare the frequency spectrum and signal power. In the direction perpendicular to the long side of the rectangular plate, the largest seismic energy with the highest frequency was achieved even with the same weights of hammer plates. Our conclusion is that it is more efficient to use a rectangular plate than a circular (or square) one when conducting a 2-D shallow seismic survey.

Implementation of Coupler for Live Wire Fault Detection System using Time-Frequnecy Domain Reflectometry (커플러를 이용한 활선 상태 배선 진단 시간-주파수 영역 반사파 계측 시스템 구현)

  • Doo, Seung-Ho;Kwak, Ki-Seok;Yoon, Tae-Sung;Park, Jin-Bae
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1541-1542
    • /
    • 2008
  • In this paper, we introduce a live wire power transmission line fault detection system using time-frequency domain reflectometry(TFDR). The TFDR is known that is more precise method than the other conventional ones. However, the TFDR is generally adopted only in fault detection for communication cable, and dead line power transmission line. Therefore, this paper suggests a TFDR system with coupler which separates 220V, 60Hz signal and TFDR reference signal for implementation the live wire fault detection system. This approach is verified by circuit simulation.

  • PDF

The review of the safety for the development of insulated hanger in overhead contact line (전차선로 절연 행거 개발에 대한 안전성 검토)

  • Lee, Jae-Bong;Park, Weon-Chan
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.1431-1440
    • /
    • 2009
  • A subway in Seoul has had a major role of public transportation after the opening of Seoul Subway Line 1 on August 15, 1974 and it has reached 34.7% of the transportation of Seoul citizens. The extended length of the subway system suppled with DC power in Korea is about 500km. In this system, the devices which are proper for regenerative power system are being required because of changeover from old braking and ATS signal system to regenerative braking and ATO signal system. In this paper, we reviewed the safety standards for the insulated hangers in overhead contact line. These hangers which have depended on foreign imports are being developed in Korea considering ease of demand and supply and economic effects.

  • PDF

Mitigation of Impulse Noise Using Slew Rate Limiter in Oversampled Signal for Power Line Communication (전력선 통신에서 오버 샘플링과 Slew Rate 제한을 이용한 임펄스 잡음 제거 기법)

  • Oh, Woojin;Natarajan, Bala
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.4
    • /
    • pp.431-437
    • /
    • 2019
  • PLC(Power Line Communication) is being used in various ways in smart grid system because of the advantages of low cost and high data throughput. However, power line channel has many problems due to impulse noise and various studies have been conducted to solve the problem. Recently, ACDL(Adaptive Cannonical Differential Limiter) which is based on an adaptive clipping with analog nonlinear filter, has been proposed and performs better than the others. In this paper, we show that ACDL is similar to the detection of slew rate with oversampled digital signal by simplification and analysis. Through the simulation under the PRIME standard it is shown that the proposed performs equal to or better than that of ACDL, but significantly reduce the complexity to implement. The BER performance is equal but the complexity is reduced to less than 10%.

A Study on the Adjusting Output Energy of the $CO_2$ Laser Controlled Directly in AC Power Line

  • Noh, Ki-Kyong;Jeong, Jong-Jin;Chung, Hyun-Ju;Kim, Hee-Je
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.5C no.4
    • /
    • pp.152-154
    • /
    • 2005
  • We demonstrate a simple $CO_2$ laser by controlling firing angle of a TRIAC switch in ac power line. The power supply for our laser system switches the voltage of the AC power line (60Hz) directly. The power supply does not need elements such as a rectifier bridge, energy-storage capacitors, or a current-limiting resistor in the discharge circuit. In order to control the laser output power, the pulse repetition rate is adjusted up to 60Hz and the firing angle of TRIAC gate is varied from $45^{circ}$ to $135^{circ}$. A ZCS(Zero Crossing Switch) circuit and a PIC one-chip microprocessor are used to control the gate signal of the TRIAC precisely. The maximum laser output of 40W is obtained at a total pressure of 18 Torr, a pulse repetition rate of 60Hz, and a TRAIC gate firing angle of $90^{circ}$.

A Study on the Implementation of 9.6Kbps Power Line Communication System for Smart Home (스마트 홈용 9.6Kbps급 전력선 통신 시스템 구현에 관한 연구)

  • Kim, Chul;Jeong, Young-Hwa
    • The Journal of Information Technology
    • /
    • v.6 no.4
    • /
    • pp.81-91
    • /
    • 2003
  • This paper is concerned with the implementation of power line communication system with 9.6Kbps. This system is suitable to establish the smart home using the power line having been installed in house. In the suggested power line communication system, we use the chirp signal with a linearity and spread spectrum frequency band of 100KHz~200KHz. We had the performance experiment for the implementation system. The experiment was achieved in the pseudo load network similar to real circumstance of power line communication. As the result, the communications under the circumstance were accomplished satisfactorily. We confirmed that the suggested 9.6Kbps power line communication system with the Chirped-SS method had the performance enough to commercialize the smart home.

  • PDF

Analysis of Channel Modeling and High Speed Data Transmission Channels for Broadband Power-Line Communication (광대역 전력선통신을 위한 채널모델링과 고속데이터 전송특성분석)

  • Rhee, Young-Chul
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.10
    • /
    • pp.1821-1827
    • /
    • 2007
  • In this paper, an analytic transfer channel modeling function by impulse signal propagation effects in indoor power-line network are analysed. The modeled channel parameters of power line channel including background noise is applied to the OFDM system and we analysis BER for QPSK and 16-QAM modulation signals with simulation. By the representation of gain for OFDM modulation, we can estimate the characteristic parameters of OFDM in Broadband power line communication.

A Signal Anti-reduction System in PLC using Ferrite Core and Switching Amplifier (페라이트 코어와 스위칭 증폭기를 이용한 PLC 신호 감쇠 저하 시스템)

  • 고종선;김영일;김규겸
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.6
    • /
    • pp.474-480
    • /
    • 2001
  • In this paper a low signal reduction communication system that does not use the communication line but power line is presented It will be very useful for an information-oriented society with tele-metering and home automation. The conventional system has a difficulty in transmitting information due to decreasing communication voltage. The proposed system employs a special type switching amplifier system which has a low inner resistance and uses high efficient ferrite core in coupling circuit. This new system is proposed to reduce the loss of conductor load and coupling circuit in a PLC system.

  • PDF

A Review of Methods for Calculation of Induced Voltage to a Communication Line from Distribution Power Line (배전선로가 초고속통신망에 미치는 유도장해 요소 분석)

  • Lim, Yong-Hun;Hyun, Duck-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1956-1958
    • /
    • 2002
  • This paper reviews the calculation of induced voltage to a communication line from Power Transmission Line. Power lines, both overhead and underground, often run parallel to weak current lines, such as telecommunication, signal or data transmission systems or protection circuits. The coexistence of both systems in parallel over long lengths is accompanied by the possible induction of significant longitudinal voltage in the weak current line. In order to evaluate a precise induced voltage, this paper indicated problem about coefficient and numerical formula and present some induced voltage production technology standard application.

  • PDF