• 제목/요약/키워드: power line impedance analyzer

검색결과 12건 처리시간 0.021초

옥내 전력선 통신 채널 임피던스 측정 장치 설계 (Design of Channel Impedance Measurement Equipment for Indoor Power Line Communications)

  • 허윤석
    • 정보학연구
    • /
    • 제8권3호
    • /
    • pp.25-33
    • /
    • 2005
  • This paper describe a method for measuring line impedance as a function of frequency for an energized powerline in normal operation. A small sinusoidal signal of a powerline communication utility frequency 30khz$\sim$1Mhz band is continuously injected into the line, and a implemented impedance analyzer calculates the indoor powerline channel impedance from the measured magnitude and phase of resulting voltage and current. The impedance measurement is executed over a range of frequencies to produce a wideband impedance versus frequency characteristic. Implemented impedance analyzer can analysis powerline communication environments measuring line impedance due to load caused in indoor. And measured analysis information through the database can use to evaluate performance of modem and to decide test environment standard.

  • PDF

옥내 전력선 통신 채널 임피던스 특성 측정 (Measurement of Channel Impedance Characteristics for Indoor Power Line Communications)

  • 허윤석;김철;홍봉화;이대영;전계석
    • 대한전자공학회논문지TC
    • /
    • 제42권11호
    • /
    • pp.79-86
    • /
    • 2005
  • 본 논문에서는 정상적으로 전기가 공급되고 있는 전력선상에서 주파수의 함수로 표현되는 임피던스 측정 방법을 기술한다. 측정방법으로 전력선 통신사용 주파수 $30Khz\~1Mhz$ 대역의 미소 신호를 연속적으로 전력선에 주입하고, 구현한 임피던스 측정 장치는 측정된 전압과 전류의 크기와 위상으로부터 옥내 채널 임피던스를 계산한다. 임피던스 측정에 있어 광대역 주파수 범위의 임피던스 대 주파수 특성을 수행한다. 구현된 임피던스 측정 장치는 옥내에서 발생하는 부하에 의해 변화하는 전력선 임피던스를 측정하여 전력선 통신 환경을 분석할 수 있는 장비이다. 측정된 데이터는 데이터베이스화 하여 전력선 통신 모뎀의 통신성능 평가 및 테스트 환경 기준 설정에 유용하게 사용될 수 있을 것이다.

전력선통신을 위한 중 전압용 전력선의 RF채널 특성 (RF Channel Characteristics of the Medium-voltage Power Line for PLC)

  • 김선효;김관호;이형철;신철재
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권7호
    • /
    • pp.316-321
    • /
    • 2002
  • In this Paper, the channel characteristics of the medium voltage(22.9kV) power line to analysis the broadband power line communication in the frequency range up to 30MHz was measured. With the sideband electrical coupler in the operating frequency range from DC to 30MHz, we measured characteristic impedance, noise and attenuation of the medium voltage power line, and then characteristic impedance was measured at the state of unloaded medium voltage power line by Scattering parameter method of Vector Network Analyzer. As a measurement result, Channel impedance shows 100~380$\Omega$ at the less than 15MHz and 70~230$\Omega$ at the more than 15 MHz. Noise characteristics of power line shows -75dBm at 20MHz and Narrowband interference noise was from 3 MHz to 7MHz.

고압전력선 통신을 위한 임피던스 측정 및 정합 방안 연구 (Impedance Measurement and Matching Technique for Medium-Voltage Powerline Communication)

  • 이재조;유정훈;홍충선;이대영
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제53권5호
    • /
    • pp.345-352
    • /
    • 2004
  • Currently, high data rate PLC(Power Line Communications), up to 100 Mbps, which use frequency bandwidth between 2 MHz and 30 MHz is investigated very hard, and commercial PLC modem for low voltage powerline network (indoor) is coming soon into communication market. For the purpose of developing a fit communication system which has little distortion of signal and attenuation, it is surely necessary to know about channel environments of powerline. Especially, the impedance measurement of the powerline and impedance matching are very important. As is known, since medium-voltage powerline (22.9 ㎸) is still working, it is not so simple to measure the powerline impedance. In our study, a portable impedance measurement equipment is developed. It consists of coupling capacitor, a drain coil and impedance matching transformer. The equipment is easily connected to medium voltage line and impedance of power line is measured using a network analyzer. Also, measurement results are used for impedance matching of PLC signal. In fact, matching transformer with several different impedances are used. The matching transformer is connected between coupling capacitor and signal port. In this paper, the developed portable impedance measurement equipment and impedance measurement results are presented. Also impedance matching technique using matching transformers will be explained. We showed the result of the improved performance by the impedance matching.

Air Line 임피던스 표준을 이용한 동축형 부하의 임피던스 정밀 측정 (Precise Impedance Measurement of Coaxial Loads using Air Line Impedance Standards)

  • 강진섭;김정환
    • 한국전자파학회논문지
    • /
    • 제11권5호
    • /
    • pp.788-795
    • /
    • 2000
  • 본 논문에서는 offset open과 offset short를 반사 표준으로 사용하고 길이가 다른 여러개의 reference air line을 임피던스 표준으로 사용한 동축형 부하의 임피던스 정밀 측정법을 제안했다. 5~1,000MHz 주파수영역에서 SWR bridge(5~400MHz)와 벡터 회로망분석기(100~1,000MHz)를 사용하여 얻은 power sensor와 thermistor mount의 입력 임피던스를 제시했다.

  • PDF

Characteristic Impedances in Low-Voltage Distribution Systems for Power Line Communication

  • Kim, Young-Sung;Kim, Jae-Chul
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권1호
    • /
    • pp.29-34
    • /
    • 2007
  • The input and output impedances in a low voltage distribution system is one of the most important matters for power line communication because from the viewpoint of communication, the attenuation characteristic of the high frequency signals is greatly caused by impedance mismatch during sending and receiving. The frequency range is from 1MHz to 30MHz. Therefore, this paper investigates the input and output impedances in order to understand the characteristic of high frequency signals in the low voltage distribution system between a pole transformer and an end user. For power line communication, the model of Korea's low voltage distribution system is proposed in a residential area and then the low voltage distribution system is set up in a laboratory. In the low voltage distribution system, S parameters are measured by using a network analyzer. Finally, input and output impedances are calculated using S parameters.

3상 PWM 컨버터의 전도성 EMI 특성에 관한 연구 (A Study on Conducted EMI Emission Characteristics in 3-Phase PWM Converter)

  • 채영민;고재석;목형수;최규하;홍순찬;백수현;이은웅
    • 전력전자학회논문지
    • /
    • 제2권2호
    • /
    • pp.41-48
    • /
    • 1997
  • 최근 고품질 전원공급에 관한 요구가 증대되면서 장치에서 발생되는 고차 고조파에 의하여 다른 기기의 오동작을 방지하기 위한 EMI(Electro Magnetic Interferencfe)에 관한 연구가 전력전자분야를 중심으로 활발하게 진행되고 있다. 따라서 본 논문에서는 3상 전력변환 장치인 다이오드 정류기와 PWM 컨버터에서 PI 전류제어방식과 히스테리시스 전류제어방식을 대상으로 LISN(Line Impedance Stabilization Network)을 사용하여 제어방식의 변화와 스위칭 주파수 변동에 따른 전도성 EMI 방출량을 측정하여 비교하였다.

  • PDF

레일 전력선통신을 위한 임피던스 정합방안 연구 (A Study on an Impedance Matching Technique for Rail Power Line Communication)

  • 서일권;안승호;김철수
    • 한국산학기술학회논문지
    • /
    • 제17권11호
    • /
    • pp.202-207
    • /
    • 2016
  • 장대 터널 및 급곡선 구간과 같은 시계 확보가 어려운 지역에서 위험 및 안전 정보를 함께 공유하기 위해서는 기관사, 열차 관제사 및 현장 작업자 사이에 보조적인 실시간 열차 정보 통신시스템의 개발이 필요하다. 이에 적합한 열차 정보 통신시스템을 개발하기 위하여 본 연구에서는 작은 노이즈와 신호 감쇄를 동시에 갖도록 하는 레일 전력선 통신을 제안하였다. 이에 대한 레일 전력선 통신의 기초 연구 일환으로서, 본 통신기법의 전송 특성을 향상할 수 있는 레일에 대한 임피던스 측정 및 정합특성 평가가 중요하다. 본 연구에서는 자체 제작한 임피던스 정합 트랜스포머와 네트워크 분석기를 이용하여 레일에 대한 반사 및 전파 특성을 평가하였다. 대향 접속방식의 임피던스 반사특성 시험결과로부터 레일 전력선 통신에 적합한 정합용 트랜스포머의 정합비율은 1:3.28임을 알 수 있었다. 또한, 제작한 임피던스 정합용 트랜스포머는 레일 전력선통신에서 투과 신호 전송을 향상할 수 있음을 확인하였다.

Compact 1×2 and 2×2 Dual Polarized Series-Fed Antenna Array for X-Band Airborne Synthetic Aperture Radar Applications

  • Kothapudi, Venkata Kishore;Kumar, Vijay
    • Journal of electromagnetic engineering and science
    • /
    • 제18권2호
    • /
    • pp.117-128
    • /
    • 2018
  • In this paper, compact linear dual polarized series-fed $1{\times}2$ linear and $2{\times}2$ planar arrays antennas for airborne SAR applications are proposed. The proposed antenna design consists of a square radiating patch that is placed on top of the substrate, a quarter wave transformer and $50-{\Omega}$ matched transformer. Matching between a radiating patch and the $50-{\Omega}$ microstrip line is accomplished through a direct coupled-feed technique with the help of an impedance inverter (${\lambda}/4$ impedance transformer) placed at both horizontal and vertical planes, in the case of the $2{\times}2$ planar array. The overall size for the prototype-1 and prototype-2 fabricated antennas are $1.9305{\times}0.9652{\times}0.05106{{\lambda}_0}^3$ and $1.9305{\times}1.9305{\times}0.05106{{\lambda}_0}^3$, respectively. The fabricated structure has been tested, and the experimental results are similar to the simulated ones. The CST MWS simulated and vector network analyzer measured reflection coefficient ($S_{11}$) results were compared, and they indicate that the proposed antenna prototype-1 yields the impedance bandwidth >140 MHz (9.56-9.72 GHz) defined by $S_{11}$<-10 dB with 1.43%, and $S_{21}$<-25 dB in the case of prototype-2 (9.58-9.74 GHz, $S_{11}$< -10 dB) >140 MHz for all the individual ports. The surface currents and the E- and H-field distributions were studied for a better understanding of the polarization mechanism. The measured results of the proposed dual polarized antenna were in accordance with the simulated analysis and showed good performance of the S-parameters and radiation patterns (co-pol and cross-pol), gain, efficiency, front-to-back ratio, half-power beam width) at the resonant frequency. With these features and its compact size, the proposed antenna will be suitable for X-band airborne synthetic aperture radar applications.

A New Directional Coupler Type Partial Discharge Sensor Installed on the Power Lead of Rotating Machine

  • Yi, Sang-Hwa;Hwang, Don-Ha;Park, Wee Sang
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권6호
    • /
    • pp.1769-1776
    • /
    • 2016
  • For on-line partial discharge (PD) monitoring of rotating machines, a novel sensor is proposed, which can be installed on the power lead inside the terminal box of the machine. The sensor has been designed to have high capacitance, and minimal reflection of measured pulses. As a sensitivity of the sensor, transfer impedance $Z_t$ has been measured and compared to conventional coupler-type sensors. A simple method is presented for measuring $Z_t$ of coupler sensors, using a vector network analyzer and a practical lead-cable of rotating machine. Through this method, it became possible to measure the $Z_t$ of coupler sensors including the installation environment of them. The $Z_t$ of the proposed sensor is higher than that of same sized other conventional couplers at frequencies between 30 and 92 MHz. Another sensitivity test has been performed using a PD calibrator as a test pulse source. The proposed sensor has higher measured peak voltage than the conventional coupler type sensors when the same charges were input.