• 제목/요약/키워드: power line environment

검색결과 359건 처리시간 0.025초

765kV 송전선로 경과지선정 및 설계측량에 신기술 도입 적용 (New Technology on Routing and Surveying a 765kV Transmission Line)

  • 이석규;김춘구;강희권;김정호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 D
    • /
    • pp.822-824
    • /
    • 1997
  • The routing and surveying a transmission line should be done in advance of its construction. It is getting more difficult to construct transmission line day by day, due to the rapid increase of people's demand resulting from the recent change of social environment and people's consciousness. In order to solve these complicated conditions actively and rationally, it is necessary to be more scientific, objective and computerizable for the routing and surveying of a transmission line. New technologies on routing and surveying a 765kV transmission line are remote sensing, Global Positioning System and Optimal PowerLine system. Thanks to these technologies, there will be a contribution to making sure of the best quality and developing technolo91r of transmission line.

  • PDF

송전선 모니터링을 위한 포인트클라우드 데이터 활용 (Application of Point Cloud Data for Transmission Power Line Monitoring)

  • 박준규;엄대용
    • 한국산학기술학회논문지
    • /
    • 제19권11호
    • /
    • pp.224-229
    • /
    • 2018
  • 우리나라는 급격한 경제발전으로 전력소비량이 크게 증가하고 있으며, 원활한 전력의 공급을 위해 많은 송전탑 및 송전선이 설치되고 있다. 고압 송전선은 주로 알루미늄 연선으로 제작되며, 전선을 느슨하게 가선하여 약간의 처짐이 유지되도록 하고 있다. 처짐의 정도는 공사의 품질과 전선의 수명에 많은 영향을 끼치게 되는데 시간이 지날수록 전선의 무게나 주변 환경적 요인으로 수축과 팽창이 반복적으로 일어나므로 송전선의 관리를 위해 주기적인 모니터링이 필수적이다. 본 연구에서는 3D 레이저 스캐닝 기술을 활용하여 송전선에 대한 모니터링을 수행하였다. 연구대상지의 송전선에 대한 데이터를 취득하고, 자료처리를 통해 송전선에 대한 포인트클라우드 형태의 3차원 공간정보를 추출하였다. 송전선에 대한 3차원 공간정보를 활용하여 송전선의 길이와 처짐량을 산출하였으며, 주변 장애물들과의 이격거리를 효과적으로 산출할 수 있었다. 연구를 통해 송전선 관리를 위한 3D 레이저 스캐닝 기술의 활용성을 제시할 수 있었으며, 향후 추가적인 연구를 통해 3D 레이저 스캐닝 기술이 적용된 송전선 모니터링 방안이 개발된다면 송전선 관리의 효율성 증대에 크게 기여할 것이다.

On-line Temperature Monitoring of the GIS Contacts Based on Infrared Sensing Technology

  • Li, Qingmin;Cong, Haoxi;Xing, Jinyuan;Qi, Bo;Li, Chengrong
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권4호
    • /
    • pp.1385-1393
    • /
    • 2014
  • Gas insulated switchgear (GIS) is widely used in the power systems, however, the contacts overheating of the inside circuit breaker or disconnector may be a potential cause of developing accidents. As the temperature of the contacts cannot be directly acquired due to existence of the metallic shield, an infrared sensor is adopted to directly measure the temperature of the shield and then the contacts temperature can be indirectly obtained by data fitting, based on which the on-line temperature monitoring technology specifically for GIS contacts based on infrared sensing is proposed in this paper. A real GIS test platform is constructed and experimental studies are carried out to account for the influential factors that affect the accuracy of the infrared temperature measurement. A heat transfer model of the GIS module is also developed, together with experimental studies, the nonlinear temperature relationship among the contacts, the metallic shield and the environment based on a neural network algorithm is established. Finally, an integrated on-line temperature monitoring system for the GIS contacts is developed for on-site applications.

송전철탑 Compact화에 따른 전기환경 영향 연구 (A Study on the Environmental Effects of Compact Tower in Transmission Line)

  • 이정원;이원교;이동일
    • 한국전기전자재료학회논문지
    • /
    • 제23권8호
    • /
    • pp.645-650
    • /
    • 2010
  • The continuous increase demand for electric power leads to the additional construction of transmission facilities, but it is not easy to acquire right-of-way for transmission facilities. Therefor, there is a need for compact tower that can be built on a narrow right-of-way the compact tower with polymer insulation arm is a solution. It can be upgrading conventional 154 kV transmission line voltages to 345 kV levels. However transmission voltage is increasing, environment interference (corona noise, radio interference, etc.) will occur gradually. This environment interference is depending on the electrical clearances of tower and configuration of conductors. Therefore the analysis of the factors of environmental interference is necessary in order to upgrading transmission voltage. This paper presents the design factor of a compact tower to meet the environmental interference standard.

1.95GHz의 전파-전파 특성에 관한 연구 (Study on the Electromagnetic Wave Propagation Characteristics at 1.95GHz)

  • 라유찬;신홍규
    • 한국음향학회지
    • /
    • 제19권5호
    • /
    • pp.53-59
    • /
    • 2000
  • 본 논문에서는 우리나라의 지형과 환경을 고려하여 전파환경을 분류하고, 1.95GHz에서 전파-전파특성을 연구하기 위해 PN 코드 상관 검파법을 이용한 다중지연파 측정 시스템을 구축하였다. 정확하고 기본적인 전파-전파 특성 측정을 위하여 우리나라의 특징적인 구조물인 시화공단을 선정하였다. 측정환경은 LOS와 N-LOS로 구분하여 전송거리에 따른 수신전력과 RMS 지연확산의 변화를 측정하였다. 측정결과 LOS의 수신전력은 -1.6dBm에서 -28.BdBm, RMS 지연확산은 0.023 ㎲∼0.22㎲이며 N-LOS의 수신전력은 -164Bm에서 -36.SdBm, RMS 지연확산은 0.068㎲∼0.37㎲가 측정되었다.

  • PDF

지하 생활공간 환경제어 설비 통합관리 기술 (Integrated management technology of environmental control facilities underground living space)

  • 강현근;김태한;전진한;이승홍
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.95-98
    • /
    • 2008
  • A power line communications, power, the outgoing line is a means of communication. DC 12 volt power lines in the system over the 2-wire control signals with the power to send the cargo configuration, and, in the basement living space, temperature, humidity, dust, CO2 sensors, and through the cooperation of the real-time detection and valves of the appropriate amount of wind, fan was designed to control. By the system's ability to communicate and control the room temperature or the status of amount of wind sent to the central system to transmit and receive signals to the center of the future, the ability to control the company said. In addition, the system HMI (Human Machine Interface) terminal by the direct control and if necessary personal portable devices to communicate with the living conditions of the underground environment in the best state that the purpose is to build.

  • PDF

고속 전력선 통신을 위한 터보 부호화된 OFDM (Turbo Coded OFDM Scheme for a High-Speed Power Line Communication)

  • 김진영;구성완
    • 한국산학기술학회논문지
    • /
    • 제11권1호
    • /
    • pp.141-150
    • /
    • 2010
  • 본 논문은 전력선 통신 채널에서 터보 부호와 OFDM 시스템의 성능을 분석하고 시뮬레이션 하였다. 전력선통신 시스템은 최악의 환경에서 동작되기 때문에 터보 부호는 전송 데이터의 신뢰성을 보장하기 위해서 사용되었다. 시뮬레이션의 성능은 비트 오류 확률로써 표현하였다. 터보 복호 알고리즘으로써 MAP과 Max-Log MAP 알고리즘, 그리고 SOVA를 선택하였고, 이것들의 성능을 비교하였다. 시뮬레이션 결과로부터, Max-Log MAP 알고리즘이 성능과 복잡도면에서 유망하다는 것이 입증되었다. 그리고 터보 부호기의 인터리버 길이가 100에서 5000으로 변할 때와 반복 횟수가 2번에서 8번으로 증가할 때, 각 각 3dB증가하였음을 알 수 있다. 본 논문에서의 결과는 OFDM를 기반으로 하는 전력선 통신 시스템에 적용될 수 있음을 보여준다.

Capacity assessment of existing corroded overhead power line structures subjected to synoptic winds

  • Niu, Huawei;Li, Xuan;Zhang, Wei
    • Wind and Structures
    • /
    • 제27권5호
    • /
    • pp.325-336
    • /
    • 2018
  • The physical infrastructure of the power systems, including the high-voltage transmission towers and lines as well as the poles and wires for power distribution at a lower voltage level, is critical for the resilience of the community since the failures or nonfunctioning of these structures could introduce large area power outages under the extreme weather events. In the current engineering practices, single circuit lattice steel towers linked by transmission lines are widely used to form power transmission systems. After years of service and continues interactions with natural and built environment, progressive damages accumulate at various structural details and could gradually change the structural performance. This study is to evaluate the typical existing transmission tower-line system subjected to synoptic winds (atmospheric boundary layer winds). Effects from the possible corrosion penetration on the structural members of the transmission towers and the aerodynamic damping force on the conductors are evaluated. However, corrosion in connections is not included. Meanwhile, corrosion on the structural members is assumed to be evenly distributed. Wind loads are calculated based on the codes used for synoptic winds and the wind tunnel experiments were carried out to obtain the drag coefficients for different panels of the transmission towers as well as for the transmission lines. Sensitivity analysis is carried out based upon the incremental dynamic analysis (IDA) to evaluate the structural capacity of the transmission tower-line system for different corrosion and loading conditions. Meanwhile, extreme value analysis is also performed to further estimate the short-term extreme response of the transmission tower-line system.

실계통에 포설된 송전용 고분자 애자의 AGING 특성 연구 (A Studies on Aging Properties for Transmission Line Polymer Insulators which are Installed in service)

  • 김수연;이상진;하영길;김동욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.152-154
    • /
    • 2001
  • Recently the extensive use of composite insulators for transmission lines can ultimately be justified only on long-term qualification tests. Especially, it is possible for the Polymer insulator to be aged in according to the environment in which it is used this may bring about the decrease of the duration of voltage application. So, this paper deals with aging property of the polymer insulator installed at real transmission line in the industry area. The contact angle, arc test, tracking test were measured for acquiring the degradation characteristics of silicone rubber and the SEM, XRF, FT-IR tests were measured for analyzing the crack and components. Also the surface leakage current of the polymer insulator was compared with that of the porcelain insulator. Finally, we knew that the aging property was not appeared during seven months at real transmission line in the industry area.

  • PDF