• Title/Summary/Keyword: power line environment

Search Result 359, Processing Time 0.024 seconds

A study for chirp signal method & system implementation in the PLC modem with low speed (저속 PLC 모뎀에서의 Chirp 신호 방식과 시스템 구현에 관한 연구)

  • Jeong, Young-Hwa;Sang-Gun Lee
    • The Journal of Information Technology
    • /
    • v.7 no.3
    • /
    • pp.37-45
    • /
    • 2004
  • The representative communication method which is applied in the low-speed power line communication modem with 60bps is single carrier method. It has been used mainly for the control. The single carrier method is very sensitive to a power line communication channel environment. Specially, the severe attenuation of the transmission signal according to the notch characteristics of channel becomes the main cause of communication error. Domestic power line channel environment has this notable feature. In this paper, we implemented the low-speed power line communication system which used the chirp signal method to be strong in notch and noise characteristics. In this research, we proposed the method which transmits 1- '1 Unit symbol Chirp signal' with a 100${\mu}s$ time within 1ms for 1 bit. Also it applied for the Convolution code for an error correction and the Manchester code for a collision perception and an error detection. It used the method which uses the bit correlator for signal detection in the receiver parts. We confirmed that the communication method of the chirp method has a excellent performance compared to single carrier methods with a result of experiment of the low-speed power line communication system with the 60bps.

  • PDF

Analysis on Attraction Power and Holding Power of Exhibition Areas at Science Museum - Focused on Analysis on Exhibition Method of Exhibition Spaces at Gwacheon National Science Museum - (과학계 박물관 전시공간의 흡입력과 지속력 분석 - 국립과천과학관 전시영역의 연출매체 분석을 중심으로 -)

  • Lim, Che-Zinn;Choo, Sung-Won;Park, Moo-Ho
    • Korean Institute of Interior Design Journal
    • /
    • v.20 no.1
    • /
    • pp.165-172
    • /
    • 2011
  • Visitors' behaviors within an exhibition space are a substantial means to grant spatial arrangement and validity of exhibits. Therefore, the study analyzed visitors' behaviors in the viewpoint of attraction power and holding power of exhibits on the basis of exhibition layout of real science museums. Through the analysis, the study grasped efficiency of analysis index and exhibition environment elements which might have an effect on planning the exhibition space of a large-scale museum and producing detailed ranges of exhibition. The main indicators used are: 1. Attraction power: it indicates the relative incidence of people who have stopped in front of an object/exhibit during the exhibition tour. It is calculated by dividing the number of people who stop by the total number of people who have visited the museum or gallery. 2. Holding power: it measures the average time spent in front of an information/communication element. It is calculated by dividing the average time of stay by the time "necessary" to read an element. As a result, It was expected that attraction power and holding power of exhibit would be increased when moving line of seeing was inductive. However, when the traffic movements of seeing was inductive, repetitive seeing of exhibit was almost never realized and visitors had a strong tendency which viewed on their way of moving without viewing on their way of stopping. On the other hand, it may mean that density of exhibit is low or size of exhibition space is small that most of exhibits within exhibition space have high attraction power and holding power. As Gwacheon National Science Museum, when a museum is composed of many large-scale exhibit halls, it should be formed by separating the main moving line of seeing from the optional moving line of seeing through visitors' natural choice of exhibit and proper inducement of moving line of seeing. In such structure, exhibition environment of the main moving line has an effect on attraction of exhibit and the use of optional moving line acts as a factor to increase attraction. In addition, it is thought that attribute of exhibit and proper arrangement of rest space within exhibition space will increase holding power of exhibit.

The Damage of Microcontroller Devices due to Coupling Effects under High Power Electromagnetic Wave by Magnetron (고출력 전자기파의 커플링 효과에 의한 마이크로 컨트롤러의 손상)

  • Hong, Joo-Il;Hwang, Sun-Mook;Huh, Chang-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.12
    • /
    • pp.2263-2268
    • /
    • 2008
  • We investigated the malfunction and destruction characteristics of microcontroller devices under high power electromagnetic(HPEM) wave by magnetron. HPEM was rated at a microwave output of 0 to 1,000 W, at a frequency of 2,450${\pm}$50 MHz and was radiated from the open-ended standard rectangular waveguide(WR-340) to free space. The influence of different reset-, clock-, data-, and power supply-line lengths has been tested. The variation of the line length was done with flat cables. The susceptibility of the tested microcontroller devices was in general much influenced by clock-, reset-, and power supply-line length, little influenced by data-line length. Further the line length was increased, the malfunction threshold was decreased as expected, because more energy couples to the devices. The surfaces of the destroyed microcontroller devices were removed and the chip conditions were investigated with microscope. The microscopic analysis of the damaged devices showed component and bondwire destructions such as breakthroughs and melting due to thermal effects. The obtained results are expected to provide fundamental data for interpreting the combined mechanism of microcontroller devices in an intentional microwave environment.

3DImmersion Type Virtual Environment System : Training Interruption-free Live-Line Workers (무정전 활선작업 피교육자를 위한 3차원 몰입형 가상환경 교육시스템의 개발)

  • 정영범;박창현;김기현;장길수
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.1
    • /
    • pp.22-30
    • /
    • 2004
  • As an information-oriented society comes, many people use PC and depend on database that network server has. However, the online data can be missed when a blackout happens and also a power failure effects on standard of judgment on Power Quality. Thus, it is reason of a trend using interruption-free live-line work when a trouble happens to power system. However, the 83% among the number of people who receive an electric shock experience when a laborer is doing interruption-free live-line works. In interruption-free method, the education and the training problem has been issued. However, we have a few instructors for that training. Furthermore, the trainees have short training period, just 4 weeks. In this paper, to develope the method that has no restriction of a time and place and reduce the wasteful materials, immersion type virtual reality(or environment) technology is used. The users of a 3D immersion type VR training system can interact with the system by doing same action in the real safe environment. Thus, it can be valuable to apply this training system to a dangerous work like as "Interruption-free live-line work exchanging COS(Cut-Out-Switch)". In this program, the user works with a instruction on the window and speaker and can't work other tasks until each part of the task completed. The workers using this system can use their hands and viewpoint movement as he is in a real environment but the trainee can't use all parts and senses of a real body with the current VR technology. Despite of this weak point, when we consider the trends of improvement in electrical devices and communication technology, we can say that 3D graphic VR application has a high potentiality.

Embodiment of the Power-Line Modem for high noise environment (내잡음성 저속 전력선 모뎀의 구현)

  • Yeo, Jin-Ki;Lee, Seung-Min;Lee, Heung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2002.11c
    • /
    • pp.558-561
    • /
    • 2002
  • In the embodiment of power line modem, the important elements are selection of a suitable line-coupler, choice of a modulation method good for channel environments, and an efficient data coding method etc. In this paper an appropriate modulation method was implemented their results in details and verified by the simulations. The data compensation request techniques that uses error checking was discussed. Finally, application of other modulation method by detection of error rate per bit according to vary of channel error caused by electric equipment that is connected to power line was studied.

  • PDF

Machine Learning-Based Signal Prediction Method for Power Line Communication Systems (전력선 통신 시스템을 위한 머신러닝 기반의 원신호 예측 기법)

  • Sun, Young Ghyu;Sim, Issac;Hong, Seung Gwan;Kim, Jin Young
    • Journal of Satellite, Information and Communications
    • /
    • v.12 no.3
    • /
    • pp.74-79
    • /
    • 2017
  • In this paper, we propose a system model that predicts the original signal transmitted from the transmitter using the received signal in the power line communication system based on the multi - layer perceptron which is one of the machine learning algorithms. Power line communication system using communication system using power network has more noise than communication system using general communication line. It causes a problem that the performance of the power line communication system is degraded. In order to solve this problem, the communication system model proposed in this paper minimizes the influence of noise through original signal prediction and mitigates the performance degradation of the power line communication system. In this paper, we prove that the original signal is predicted by applying the proposed communication system model to the white noise environment.

Estimation of Power Collector Wear Considering the Operating Environment of a Maglev (자기부상열차의 주행 환경을 고려한 집전자 마모도 평가)

  • Lee, Kyoung-bok;Ma, Sang-kyeon;Lim, Jae-won;Park, Do-young;Son, Jeong-ryong;Kang, Hyun-il
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.66 no.1
    • /
    • pp.38-42
    • /
    • 2017
  • The wear of the third track power collector is one of the essential check factors for safe train operation. Rapid wear of the current collector accelerates the line of the catenary. In addition, the arc generated when the catenary line is turned off causes a malfunction in the minute portion of the catenary line, thereby shortening the life of the catenary line. In this paper, to analyze the mechanical wear of the current collector during driving according to the environmental factor of the Maglev(magnetic levitation train), it was divided into dry season and wet season. the wear of metallized collector, copper alloy collector and carbon collector were measured and compared with each other. The wear rate was measured according to the position of the wire, the position of the power collector and the position per hour. Microscopic photographs of the cross section and surface of the power collector were measured. The electrical currents of the metallized collector, copper alloy collector and carbon collector were measured.

A Investment on Wire-wireless Communication Method for Electrical Device Infrastructure Maintenance (전력설비 관리를 위한 무선 및 유선 통신 방법에 관한 고찰)

  • Kim, Young-Eok;Lee, Jin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.2
    • /
    • pp.354-359
    • /
    • 2016
  • Power plants maintenance data is to be sent to management server system via a communication network. In this case, reliable communication network is required. Transmission of the power plants maintenance data is used in the wired communication network or wireless communication network. PLC communication network is a kind of wired communication network. However PLC communication network is easily affected by noise. On the vulnerable areas in power line system, such as a mountain or rural areas, it is difficult to form a power line communication network. For a wireless communication, environment are also influenced factors in wireless communication. Harsh environmental factors are bring the communication characteristic degradation. In such areas it can be used a combination of two networks and in this way the complementary function can be achieved. Power plants are distributed in various regions across the country. The appropriate communication network is needed to maintain the power plant.This study investigated the effect of environment on the wired communication and wireless communication. It would examine a variable factor which is affect to the communication characteristic. We used PLC communication for wired communication network and ZigBee communication for wireless communication network. We investigated the characteristics of a single communication network and it raised the need for a complex communication technology to complement a single communication network.

Smart Home Network System Using the Broadband Power Line Communication(BPLC) (광대역 전력선 통신을 이용한 스마트 홈 네트워크 구성에 관한 연구)

  • Yang Hyun-Chang;Sim Kwee-Bo
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2005.11a
    • /
    • pp.87-90
    • /
    • 2005
  • The Intelligent Home provides convenient and comfortable living environment by performing automatic control, heating and air-conditioning, ventilation, home appliances control, home robot control, energy management, visitor management security management, internet, heath state monitoring, etc. through wired/ wireless network and device in the household. Along with the presentation of the features of economical broadband power line communication in the network configuration for new and old houses, its improvement method is proposed.

  • PDF

Live line maintenance technique trend of UHV T/L (초고압 송전선로의 활선공법 기술 동향)

  • Lee, Dong-Il;Choi, In-Hyuk;Jung, Yoon-Hwan
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.260-264
    • /
    • 2005
  • This paper gives a basic information of live line maintenance technique of UHV T/L and introduce a technical background and trends of domestic and abroad. The importance of live line maintenance technology getting increased because the change of power system environment and maintenance conditions in korea. this paper explain the present state of the development of live line maintenance technique in korea and show a difference with advanced countries.

  • PDF