• 제목/요약/키워드: power line environment

검색결과 359건 처리시간 0.023초

±500kV HVDC 2회선 송전선로의 전기환경특성 예측 및 평가 (Prediction and Analysis of Electrical Environmental Characteristics under ±500kV HVDC Double Bipole Transmission Line)

  • 우정민;주문노;신구용;권구민;최우정;이재현
    • 전기학회논문지
    • /
    • 제67권4호
    • /
    • pp.554-560
    • /
    • 2018
  • Since Korea has a small land area, it is expected to construct the conductor return type with neutral wire in the case of ${\pm}500kV$ HVDC double bipole transmission line. Therefore, in order to apply ${\pm}500kV$ HVDC double bipole transmission line with neutral wire in Korea, it is necessary to develop technology for insulation and environmental designs. In this study, radio interference, audible noise, electric field and ion current density according to the polarity arrangement were compared and assessed in the ${\pm}500kV$ HVDC double bipole transmission line with the conductor return method. And the optimum configuration of HVDC double bipole transmission line was determined from the viewpoint of electrical environment.

전력선 통신환경에서의 구동회로 개선에 관한 연구 (A study on the improvement of Drive circuit in the Power Line Communication)

  • 임승하
    • 전자공학회논문지 IE
    • /
    • 제44권4호
    • /
    • pp.30-34
    • /
    • 2007
  • 전력선 통신에서는 전력을 공급하기 위해 설치된 전력선을 통신 매체로 사용하기 때문에 채널 환경이 열악하다고 할 수 있다. 본 논문에서는 원활한 통신을 위해 신호 감쇠를 저감하는 결합기를 적용한 gate 구동회로를 설계하였다. 결합기의 수신 동작과 송신 동작을 등가회로 해석하여 구동회로에 적합한 임피던스를 갖도록 설계하였다. 그 결과 전력선에 연결된 수 많은 전자 제품들의 상호 작용으로 인한 임피던스 변화에 대한 환경을 개선하여 전력선 통신에서의 BER(Bit Error Rate)을 45% 향상하여 더 원활한 통신을 할 수 있도록 하였다.

옥내 전력선 통신 채널 특성 측정 (Measurement of the indoor power line channel characteristic)

  • 허윤석
    • 정보학연구
    • /
    • 제7권3호
    • /
    • pp.1-10
    • /
    • 2004
  • 옥내${\cdot}$외의 전력선 환경에 대한 정확한 채널 모델링에 관한 노력이 최근에 이루어지고 있다. 알려진 일반표준, 제한과 발표된 모델들은 특별한 형태의 접근들이였다. 본 논문에서는 더 신속하고 효율적인 전력선 통신 실험을 위한 전력선 채널 모델링에 관한 연구이다. 용량성 부하 시뮬레이터는 전력선 옥내 망 모뎀 개발에 필수적인 장비이다. 총 244 경우의 용량성 부하 변화에 대한 주파수 응답 특성 측정으로 채널 모델링을 수행하였다. 본 측정 실험에서 PLC는 일반적으로 알고 있었던 특성 보다 더 확정적인 매체라는 것을 확인하였다.

  • PDF

전력선통신 시스템을 위한 인공지능 기반 효율적 신호 검출 (Efficient Signal Detection Based on Artificial Intelligence for Power Line Communication Systems)

  • 김도균;황유민;심이삭;김진영
    • 한국위성정보통신학회논문지
    • /
    • 제12권2호
    • /
    • pp.42-45
    • /
    • 2017
  • 전력선통신 시스템에서는 전력망을 활용한 통신 방식을 사용하기 때문에 일반적 통신선로를 활용한 통신 방식에 비해 잡음이 많고, 이것으로 인한 성능 저하가 문제가 되고 있다. 이러한 잡음으로 인한 성능 저하를 완화시키기 위해, 본 논문에서는 전력선통신 시스템에서의 임펄스 잡음 환경에서 신호를 검출하는 인공지능 알고리즘을 제안한다. 다항식 회귀법을 이용하여 임펄스 잡음 신호의 원신호를 예측하고, 시뮬레이션 결과를 통해 본 논문에서 제안한 인공지능 알고리즘을 적용한 전력선통신 시스템에서 임펄스 잡음 환경내 신호 검출 성능 향상을 입증한다.

Effects of a Static Synchronous Series Compensator (SSSC) Based on a Soft Switching 48-Pulse PWM Inverter on the Power Demand from the Grid

  • Ustun, Taha Selim;Mekhilef, Saad
    • Journal of Power Electronics
    • /
    • 제10권1호
    • /
    • pp.85-90
    • /
    • 2010
  • In this paper the effects of a Static Synchronous Series Compensator, which is constructed with a 48-pulse inverter, on the power demand from the grid are studied. Extensive simulation studies were carried out in the MATLAB simulation environment to observe the compensation achieved by the SSSC and its effects on the line voltage, line current, phase angle and real/reactive power. The designed device is simulated in a power system which is comprised of a three phase power source, a transmission line, line inductance and load. The system parameters such as line voltage, line current, reactive power Q and real power P transmissions are observed both when the SSSC is connected to and disconnected from the power system. The motivation for modeling a SSSC from a multi-pulse inverter is to enhance the voltage waveform of the device and this is observed in the total harmonic distortion (THD) analysis performed at the end of the paper. According to the results, the power flow and phase angle can be controlled successfully by the new device through voltage injection. Finally a THD analysis is performed to see the harmonics content. The effect on the quality of the line voltage and current is acceptable according to international standards.

로봇을 활용한 배전 활선공법 기술분석 및 적용 타당성 연구 (Analysis and Applicability Assessment of Robotic Live-Line Electricity Distribution Technology)

  • 양선제;국태용;박춘식;서인용
    • 전기학회논문지
    • /
    • 제67권9호
    • /
    • pp.1125-1140
    • /
    • 2018
  • This paper analyzes robotic technology developed for live-line electricity distribution and its applicability to domestic environment. In doing so, available robotic systems developed for the live-line work are thoroughly investigated and compared in terms of from robotic functionality to economic feasibility. To assess the technology readiness for domestic live-line robot, the rubber gloves based direct live-line engineering methods have been also analyzed and mapped into robotic technology requisites. The results are expected as a fundamental data to help with solving the safety and economics issues when considering development and introduction of compact live-line robot for complex domestic electricity distribution environment.

전력선 통신을 위한 변조 방식의 특성 비교 (Comparison with modulation method for PLC)

  • 서종완;이정훈;이종주;정호성;신명철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.193-195
    • /
    • 2000
  • Power Line Communication(PLC) is the old technique. But it's worked in a very low spees. Developing of wireless communication technique, PLC is adopted these tech, for high speed communication. However, Power line environment differ from wireless environment. This paper survey modulation techniques and find the best modulation technique which is appropriate for power line environment.

  • PDF

옥내 전력선 통신 채널 임피던스 측정 장치 설계 (Design of Channel Impedance Measurement Equipment for Indoor Power Line Communications)

  • 허윤석
    • 정보학연구
    • /
    • 제8권3호
    • /
    • pp.25-33
    • /
    • 2005
  • This paper describe a method for measuring line impedance as a function of frequency for an energized powerline in normal operation. A small sinusoidal signal of a powerline communication utility frequency 30khz$\sim$1Mhz band is continuously injected into the line, and a implemented impedance analyzer calculates the indoor powerline channel impedance from the measured magnitude and phase of resulting voltage and current. The impedance measurement is executed over a range of frequencies to produce a wideband impedance versus frequency characteristic. Implemented impedance analyzer can analysis powerline communication environments measuring line impedance due to load caused in indoor. And measured analysis information through the database can use to evaluate performance of modem and to decide test environment standard.

  • PDF

드론 기반의 전력선 추적 제어 시스템 (Drone-based Power-line Tracking System)

  • 정종민;김재승;윤태성;박진배
    • 전기학회논문지
    • /
    • 제67권6호
    • /
    • pp.773-781
    • /
    • 2018
  • In recent years, a study of power-line inspection using an unmanned aerial vehicle (UAV) has been actively conducted. However, relevant studies have been conducting power-line inspection with an UAV operated by manual control, and they have developed just power-line detection algorithm on aerial images. To overcome limitations of existing research, we propose a drone-based power-line tracking system in this paper. The main contributions of this paper are to operate developed system under configured environment and to develop a power-line detection algorithm in real-time. Developed system is composed of the power-line detection and the image-based tracking control. To detect a power-line in real-time, a region of interest (ROI) image is extracted. Furthermore, clustering algorithm is used in order to discriminate the power-line from background. Finally, the power-line is detected by using the Hough transform, and a center position and a tilt angle are estimated by using the Kalman filter to control a drone smoothly. We design a position controller and an attitude controller for image-based tracking control, and both controllers are designed based on the proportional-derivative (PD) control method. The interaction between the position controller and the attitude controller makes the drone track the power-line. Several experiments were carried out in environments where conditions are similar to actual environments, which demonstrates the superiority of the developed system.

Electromagnetic Environment of Transmission Line Based on Full Parameter Online Estimation

  • Sun, Zidan;Zhou, Xiaofeng;Liang, Likai;Mo, Yang
    • Journal of Information Processing Systems
    • /
    • 제16권2호
    • /
    • pp.394-405
    • /
    • 2020
  • The parameters of transmission lines have an influence on the electromagnetic environment surrounding the line. This paper proposes a method based on phasor measurement unit (PMU) and supervisory control and data acquisition (SCADA) to achieve online estimation of transmission line full parameters, such as resistance, reactance and susceptance. The proposed full parameter estimation method is compared with the traditional method of estimating resistance independently based on SCADA system. Then, the electromagnetic environment is analyzed based on the different parameter estimation methods. The example results illustrate that online estimation of transmission line full parameters is more accurate in the analysis of electromagnetic environment, which further confirms its necessity and significance in engineering application.