• 제목/요약/키워드: power level

검색결과 7,440건 처리시간 0.032초

D2D Power Control in the Cellular System: Non Cooperative Game Theoretic Approach

  • Oh, Changyoon
    • 한국컴퓨터정보학회논문지
    • /
    • 제23권3호
    • /
    • pp.25-31
    • /
    • 2018
  • In this paper, we consider the game theoretic approach to investigate the transmit power optimization problem where D2D users share the uplink of the cellular system. Especially, we formulate the transmit power optimization problem as a non cooperative power control game. In the user wide sense, each user may try to select its transmit power level so as to maximize its utility in a selfish way. In the system wide, the transmit power levels of all users eventually converge to the unique point, called Nash Equilibrium. We first formulate the transmit power optimization problem as a non cooperative power control game. Next, we examine the existence of Nash Equilibrium. Finally, we present the numerical example that shows the convergence to the unique transmit power level.

증기 발생기 수위제어를 위한 모델예측제어기 설계 (Design of Model Predictive Controller for Water Level control in the Steam Generator of a nuclear Power Plants)

  • 손덕현;이창구
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제50권8호
    • /
    • pp.376-383
    • /
    • 2001
  • Factors leading to poor control of the steam generator in a nuclear power plant are nonminimum phase characteristics, unreliable of flow measurements and nonlinear characteristics, which increase more at low power(below 20%) operation. And the study of problems for water level control in the steam generator is that design water level controller only power renge, not entire. This paper introduces a model predictive control(MPC) algorithm for solving poor control factors and quadratic programming(QP) for solving input constraints. Also presents the design method of stable model predictive controller in the entire power range. The simulation results show the efficiency of proposed MPC controller by comparing with PI controller, and effect of the design parameters.

  • PDF

RADIATION SHIELDING EVALUATION OF IP-2 PACKAGES FOR LOW- AND INTERMEDIATE-LEVEL RADIOACTIVE WASTE

  • Kim, Min-Chul;Choi, Jong-Rak;Chung, Sung-Hwan;Ko, Jae-Hoon
    • Nuclear Engineering and Technology
    • /
    • 제40권6호
    • /
    • pp.511-516
    • /
    • 2008
  • Korea Hydro & Nuclear Power Co., Ltd. (KHNP) developed new IP-2 packages to transport low- and intermediate-level radioactive waste (LILW) steel drums from nuclear power plants to a disposal facility in accordance with IAEA and Korean transport regulations of radioactive material. Radiation shielding evaluation of the packages was carried out to demonstrate compliance with the regulatory requirements for IP-2 packages of radioactive material. Dose rate limits of LILW drums contained in the packages were determined.

원자력발전소 방호도장 Service Level 분류에 대한 고찰 (Study on Classification of Protective Coating Service Level in Nuclear Power Plant)

  • 임상준
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 추계 학술논문 발표대회
    • /
    • pp.140-141
    • /
    • 2018
  • Protective coatings at nuclear power plants should be designed to withstand exposure to ambient conditions during normal operation or design-basis accidents. However, there was a change in the perception of the protective coating to the revision of the Regulatory Guidelines by the NRC in July 2000. In other words, maintenance guidelines have been strengthened in order to minimize the clogging of the cooling water system due to the substances in the containment building. Therefore, KHNP, the contractor and operator of the nuclear power plant, plans to develop the coating system for nuclear power plants in accordance with the regulation, and plans to develop its own coating expert.

  • PDF

무정전전원장치용 3-레벨 인터리브드 충방전기에 대한 연구 (A Study on 3-level Interleaved Charger-Discharger for Uninterruptible Power Supplies)

  • 구태근;이인환;조영훈
    • 전력전자학회논문지
    • /
    • 제22권6호
    • /
    • pp.535-542
    • /
    • 2017
  • This paper proposes a simple 3-level interleaved charger-discharger for the uninterruptible power supply (UPS) with various combinations of battery cells. The proposed converter not only improves charging and discharging efficiency, but also reduces the physical volume and the cost. Furthermore, the converter also offers the capability of the neutral point voltage, so that more stable operation can be obtained. In addition, the proposed converter significantly reduces the ripple current of the battery inductor, thereby providing an expected life extension of the battery. Experimental results for a 300kVA UPS prototype verify the validity of the proposed converter. The proposed charger-discharger is suitable for UPSs and energy storage systems (ESSs) with wide input battery voltage ranges.

배전선 보호기기 선정 시 계통 연계 분산전원의 용량 고려 (Consideration of the Distributed Generator's Capacity in Determining the Protective Devices)

  • 박인기;장성일;박용업;김세근;김광호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.331-333
    • /
    • 2003
  • This paper describes the effect of the interconnected wind turbine generators on fault current level of distribution networks. Distributed generator(DG) interconnected with grid can supply the power into a power network not only the normal conditions, but also the fault conditions of distribution network. If the fault happened in the distribution power line with DG, the fault current level measured in a relaying point might be higher than that of distribution network without wind turbine generator due to the contribution of wind farm. Consequently, it may destroy the conventional protective devices applied in the distribution network with DG. Simulation results shows that the current level of fault happened in the power line with DG depends on the power output of DG.

  • PDF

Tank회로를 이용한 배전선신호 결합장치의 특성분석 (Signal Transmission Characteristic of PLC Coupler using Tank Circuit)

  • 김종수;계문호;유동욱;오성철;김종우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 B
    • /
    • pp.809-811
    • /
    • 1993
  • The load impedance of power lines generally varies with time, areas, and season. Also, the harmonic noises by the power electrical equipments are scattered through the power lines. The received signal level varies with the environment and is not able to detect the PLC(Power Line Carrier) signal. For this reason, it is requried for the signal transmitter to hold the received signal level uniform independently with the variation of the load impedence. In this paper, the power lines are modeled simply and a method keeping the received signal level uniform is suggested through the analysis of the signal transmission characteritics of the PLC coupler using tank circuit.

  • PDF

Feasibility Analysis on Ground-level Stations and Wireless Power Transfer Technology Applications for Monorail System

  • Hwang, Karam;Chung, Jong-Duk;Lee, Kibeom;Tak, Junyoung;Suh, In-Soo
    • International Journal of Railway
    • /
    • 제7권3호
    • /
    • pp.71-79
    • /
    • 2014
  • Subway systems have been a proved method of public transport and are widely used in major cities around the world. However, the time and cost it takes to construct such systems are very high, as it requires underground tunnels. Cities in various countries have implemented monorail systems as public railway transport as it can be more economical and quicker compared to subway systems in terms of construction. In addition, it provides more convenience towards the public as it is not affected to traffic, and also provides an aerial view of the city. However, the overall construction cost for monorail systems is still significantly high, and as a possible solution to further reduce the overall cost, implementation of ground-level stations and wireless power transfer technology has been proposed in this paper. A concept application layout of ground-level stations and wireless power transfer systems has been discussed, using the Daegu monorail Line 3 system as a simulation base. The expected cost for monorail systems implementing ground-level stations and/or wireless power transfer technology has been estimated based on literature survey, and was compared with the current construction cost of Daegu monorail system. Based on comparison, it has shown that implementation of ground-level stations are the most economical, and can be easily implemented for either starting or expanding the monorail line. Implementation of wireless power transfer technology is also economical, but is more feasible when starting a new monorail line as it requires components which will alter the configuration of the train and infrastructure.

IM(Integrated Magnetics) 방식을 이용한 Three-Level 컨버터 (The Three-Level Converter using IM(Integrated Magnetics) method)

  • 배진용;김용;권순도;엄태민
    • 조명전기설비학회논문지
    • /
    • 제22권4호
    • /
    • pp.35-45
    • /
    • 2008
  • 본 논문에서는 대용량 출력에 적합한 Three-Level 컨버터에 대하여 논하였다. 전력 변환 시스템에서 에너지의 저장, 변환, 전기적 절연 및 필터 등을 위한 자성체의 적절한 설계는 매우 중요하다. 제안된 Three-Level 컨버터는 출력단 인덕터와 변압기의 결합을 통하여 자성체의 수를 저감하였다. 본 연구에서는 Three-Level 컨버터에서 자기회로 해석을 기반으로한 릴럭턴스 모델을 제안하고자 한다. 또한, 단일 코어 변압기 결선에 의한 2차측 정류방식에 대하여 논하고자 한다. 본 연구에서는 IGBT를 사용하여 입력 540[V], 출력 48[V], 3[kW]급 시스템을 제작했으며 40[kHz]에서 실험하였다.

적응형 바이어스 조절 회로를 사용한 무선에너지 전송용 고효율 전력증폭기 (High PAE Power Amplifier Using Adaptive Bias Control Circuit for Wireless Power Transmission)

  • 황현욱;서철헌
    • 전자공학회논문지
    • /
    • 제49권10호
    • /
    • pp.43-46
    • /
    • 2012
  • 본 논문에서는 구동 증폭기와 Class-E 전력증폭기를 결합하여 높은 효율의 고이득 이단 전력증폭기를 구현하였다. 고효율 이단 Class-E 전력증폭기의 입력 단에 적응형 바이어스 조절 회로를 적용하여 낮은 입력 전력의 전력효율을 개선하였다. 최대출력인 40 dBm에서 고정 바이어스 전력증폭기와 적응형 바이어스 증폭기 둘 다 약 76 %의 효율을 갖는다. 하지만 적응형 바이어스 조절 회로가 적용된 전력증폭기의 입력전력 6dBm 인가했을 때 효율은 약 70 %이고 고정된 바이어스 입력시에 효율은 약 50 %이다. 바이어스 조절을 통해 낮은 입력에서 높은 효율을 갖는 회로를 설계하였다.