• Title/Summary/Keyword: power control (PC)

Search Result 298, Processing Time 0.025 seconds

Network Based UPS Remote Control System Using SNMP (네트워크 환경에서의 무정전전원장치용 원격제어 시스템)

  • 최소영
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.744-747
    • /
    • 2000
  • This paper aims at developing remote control system to control and monitor distribute various devices through internet or information communication network. So far for managing UPS(Uninterruptible Power Supply) serial communication system has been used. This paper proposes managing method of UPS monitoring using SNMP. It consists of SNMP agent network board SNMP manager PC software serial communication software and UPS. The proposed method can be applied to various devices with communication network remotely.

  • PDF

The Study of PV PCS MPPT Control Position (PV용 PCS의 MPPT 제어 포지션 고찰)

  • Park, Yong-Sung;Park, Ga-Woo;Yu, Gwon-Jong;Jung, Myoung-Woong;Jeong, Yeong-Seok;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1356-1358
    • /
    • 2003
  • This paper describes the control of grid connected transformerless type PV power conditioning system, which is simple and more efficient than the usual transformer type system. With the modeling and analysis of power system, the validity of control strategy is well verified through the simulation and experimental results.

  • PDF

The Effects of Sa-Am Acupuncture on the Radial Pulse in Healthy Human Subjects: A Comparative Study of Pericardium jung-gyuck and Triple Energizer jung-gyuck

  • Kim, Tae-Min;Kim, Jea-Hong;Lee, Hyun-Suk;Yim, Yun-Kyoung
    • The Journal of Korean Medicine
    • /
    • v.38 no.4
    • /
    • pp.41-54
    • /
    • 2017
  • Objectives: The purpose of this study is to investigate the effects of Sa-am acupuncture with Pericardium jung-gyuck (SA-acu-PC) and Triple Energizer jung-gyuck (SA-acu-TE) on the radial pulse in healthy human subjects. Methods: Sixty healthy subjects participated in this study and divided into three groups randomly: Control group(C), Pericardium jung-gyuck group(PC), Triple Energizer jung-gyuck group(TE). Radial pulse was measured by 3 dimensional pulse imaging system (DMP-3000) before, right after, 30 minutes after, and 60 minutes after acupuncture. Results: 1. The changes observed in periodic parameters are considered as the common effects of both SA-acu-TE and SA-acu-PC. SA-acu-TE was more effective than SA-acu-PC in these effects. 2. The effects of SA-acu-PC appeared in the pulse amplitude, pulse area, and pulse power volume mainly at the left chon position, and 3. The effects of SA-acu-TE appeared in the radial augmentation index and main peak angle mainly at the right gwan position. Conclusions: The effects of SA-acu-PC and SA-acu-TE can be observed in the radial pulse. The increases in pulse amplitude, pulse area, and pulse power volume at the left chon may imply the effects of SA-acu-PC. And the decrease in the pulse power volume, the increases in radial augmentation index and main peak angle may imply the effects of SA-acu-TE.

High Speed PLC-based Automatic Control System for a Smart LED Streetlight (스마트 LED 가로등을 위한 고속 전력선 통신 기반 자동제어 시스템)

  • Kim, Young-Suk;Lin, Chi-Ho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.5
    • /
    • pp.95-102
    • /
    • 2014
  • In this paper, we propose the high speed PLC-based automatic control system for a smart LED streetlight. The proposed the automatic control system were constructed of a power line modem part and monitoring part, streetlight controller part for the high speed communication frequency band and streetlight ballasts characterization and real-time remote control using a high-speed PLC network, and it was designed to meet to lighting grades conditions of KS road lighting standards. The proposed automatic control system were easy monitoring of the power consumption using PC through to the comparison result of the existing streetlight system. As a result, it was confirmed to the possibility of efficient operation for the real-time monitoring and maintenance by induction of reasonable power consumption through to the LED streetlight state checking and remote-control. In addition, we proved to improvement of expected effects for the power cost savings, the energy efficiency, and streetlight differentiation and advanced.

The Development of an Automatic Aquaculture System -1. Using a model tank- (양어장 자동화 시스템의 개발 -1. 모형 수조를 중심으로-)

  • KANG Ho-Won;LEE Seong-Ho;KIM Je-Yoon;JEONG Seok-Kwon;KIM Sang-Bong
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.28 no.3
    • /
    • pp.294-300
    • /
    • 1995
  • In aquaculture industrial field, an automatic management and control system is needed to cope with the difficulties such as expensive wage, ripe age of management worker and risk according to the unexpected change of environmental conditions in the aquarium. This paper introduces an automatic aquarium monitoring and control system. The system is developed using PC single board computer. A PC can be connected to multi-single hoard computers, and the communication between PC and single board computers is based on RS-422/485 interfacing method. The physical data of pH, DO, temperature and water level etc. are real-timely treated in the single board computer though individual transducers, transfered to the main monitoring PC through RS-422/485 communication, and those data are graphically shown on the PC monitor. Furthermore, the environmental circumstance can be monitored through the image processing system, and the emergency system can be operated under the condition of environmental incident such as electric power stoppage, DO deficiency, pump shut down and low level water etc.

  • PDF

Phase Control of Transmit Antennas in SIMO Systems (다중 송신안테나 통신시스템에서 송신 안테나의 위상 조절 기법)

  • Kim, Young-Gil
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.8A
    • /
    • pp.612-617
    • /
    • 2012
  • Two phase control (PC) schemes using limited feedback are proposed for multiple-input single-output (MISO) systems. One PC scheme cophases channel gains with respect to the first transmit antenna channel gain, and the other PC scheme cophases channel gains by positioning all the channel gains into a fixed sector. We analyze the combined channel gain for both PC schemes, and find that the PC scheme that cophases with respect to the first transmit antenna channel gain provides 1.2 dB power gain over an orthogonal space-time block code (OSTBC) when the number of transmit antennas is four and the number of feedback bits is three.

Development of the Real-Time Simulator of a Turning-Type Sluice Gate Actuated by the Hydraulic Cylinder (유압실린더 구동식 전도 수문의 실시간 모의시험기 개발)

  • Lee, Seong-Rae
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.4
    • /
    • pp.192-198
    • /
    • 2006
  • The real-time simulator of a turning-type sluice gate actuated by the hydraulic cylinders is developed using a PC and a visual C++ program language. The real-time simulator receives the directional control valve signal selected by the operator using the mouse, updates the state variables of the turning-type sluice gate system responding to the control signal, and draws the moving figures of the sluice gate, cylinder, reserved water every drawing time on the PC monitor. Also, the operator can observe the sluice gate angle, cylinder force, cylinder pressures, and hydraulic power representing the operation of sluice gate system through the PC monitor every drawing time. The simulator can be a very useful tool to design and improve the turning-type sluice gate system.

Parallel Operation Control of 3-phase 4-leg PCS Using Modified Droop Control Method (개선된 드룹제어 방식을 이용한 3상 4레그 PCS의 병렬운전)

  • Kim, Ki Ryong;Oh, Chang-Yeol;Kwon, Min-Ho;Kim, Tae-Jin;Lee, Jong-Pil
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.370-371
    • /
    • 2019
  • 태양광 및 풍력과 같은 신 재생에너지원을 바탕으로 하는 분산 발전이 증가함에 따라 대용량의 PCS가 요구된다. 대용량의 PCS를 제어하기 위해서는 병렬운전이 바탕이 되어야 한다. 본 논문에서는 통신 없이 제어가 가능한 기존의 드룹 제어의 장점을 살리면서 전력 편차가 적은 마스터 슬레이브 제어의 장점을 결합한 병렬운전 제어 방식을 제안하고 시뮬레이션을 통해 제어 알고리즘의 타당성을 검증하고자 한다.

  • PDF

Fuzzy Logic Speed Controller of 3-Phase Induction Motors for Efficiency Improvement

  • Abdelkarim, Emad;Ahmed, Mahrous;Orabi, Mohamed;Mutschler, Peter
    • Journal of Power Electronics
    • /
    • v.12 no.2
    • /
    • pp.305-316
    • /
    • 2012
  • The paper presents an accurate loss model based controller of an induction motor to calculate the optimal air gap flux. The model includes copper losses, iron losses, harmonic losses, friction and windage losses, and stray losses. These losses are represented as a function of the air gap flux. By using the calculated optimal air gap flux compared with rated flux for speed sensorless indirect vector controlled induction motor, an improvement in motor efficiency is achieved. The motor speed performance is improved using a fuzzy logic speed controller instead of a PI controller. The fuzzy logic speed controller was simulated using the fuzzy control interface block of MATLAB/SIMULINK program. The control algorithm is experimentally tested within a PC under RTAI-Linux. The simulation and experimental results show the improvement in motor efficiency and speed performance.

A Study of the Grid Connected Transformer-less PV PC

  • Park Y.S.;Choi J.H.;Park G.W.;Yu G.J.;Jung Y.S.;Choi J.Y.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.524-527
    • /
    • 2003
  • This paper describes control of the grid connected transformer-less type photovoltaic(PV) power conditioning system. which is simpler and more efficient than conventional transformer type systems. With modeling and analysis of PV system, the validity of the control strategy was verified by simulations and experimental results.

  • PDF