Research on heat transfer coefficient of supercritical water based on factorial and correspondence analysis

  • Xiang, Feng;Tao, Zhou;Jialei, Zhang;Boya, Zhang;Dongliang, Ma
    • Nuclear Engineering and Technology
    • /
    • 제52권7호
    • /
    • pp.1409-1416
    • /
    • 2020
  • The study of heat transfer coefficient of supercritical water plays an important role in improving the heat transfer efficiency of the reactor. Taking the supercritical natural circulation experimental bench as the research object, the effects of power, flow, pipe diameter and mainstream temperature on the heat transfer coefficient of supercritical water were studied. At the same time, the experimental data of Chen Yuzhou's supercritical water heat transfer coefficient was collected. Through the factorial design method, the influence of different factors and their interactions on the heat transfer coefficient of supercritical water is analyzed. Through the corresponding analysis method, the influencing factors of different levels of heat transfer coefficient are analyzed. It can be found: Except for the effects of flow rate, power, power-temperature and temperature, the influence of other factors on the natural circulation heat transfer coefficient of supercritical water is negligible. When the heat transfer coefficient is low, it is mainly affected by the pipe diameter. As the heat transfer coefficient is further increased, it is mainly affected by temperature and power. When the heat transfer coefficient is at a large level, the influence of the flow rate is the largest at this time.

전력수요 탄력성에 따른 각 용도별 부하의 전력수요 영향 (The Effects of the Electric Power Demand for Each Loads Based the Electric Power Demand Elasticity)

  • 김문영;백영식;송경빈
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권12호
    • /
    • pp.568-574
    • /
    • 2001
  • The variations of real time electric power price in competitive electricity markets have influence on electric power demands of the consumers. The effects of the consumers for electric power price can be expressed the price elasticity coefficient of the power demand as a measurement. Residential, commercial, and industrial consumers with different characteristics cause the different price elasticity of the power demand due to changing the pattern of consumption. It is necessary that the effects of electric power demands as a function of elasticity coefficient for each loads should be analyzed in Korea which is processing deregulated electric market. Therefore, this paper calculate the elasticity coefficient of each loads and analysis the effects of electric power demands as a function of elasticity coefficient of inflexible and flexible consumers in competitive electricity market.

  • PDF

Research on Line Overload Emergency Control Strategy Based on the Source-Load Synergy Coefficient

  • Ma, Jing;Kang, Wenbo;Thorp, James S.
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권3호
    • /
    • pp.1079-1088
    • /
    • 2018
  • A line overload emergency control strategy based on the source-load synergy coefficient is proposed in this paper. First, the definition of the source-load synergy coefficient is introduced. When line overload is detected, the source-load branch synergy coefficient and source-load distribution synergy coefficient are calculated according to the real-time operation mode of the system. Second, the generator tripping and load shedding control node set is determined according to the source-load branch synergy coefficient. And then, according to the line overload condition, the control quantity of each control node is determined using the Double Fitness Particle Swarm Optimization (DFPSO), with minimum system economic loss as the objective function. Thus load shedding for the overloaded line could be realized. On this basis, in order to guarantee continuous and reliable power supply, on the condition that no new line overload is caused, some of the untripped generators are selected according to the source-load distribution synergy coefficient to increase power output. Thus power supply could be restored to some of the shedded loads, and the economic loss caused by emergency control could be minimized. Simulation tests on the IEEE 10-machine 39-bus system verify the effectiveness and feasibility of the proposed strategy.

On Power of Correlated Superposition Coding in NOMA

  • Chung, Kyuhyuk
    • 전기전자학회논문지
    • /
    • 제24권1호
    • /
    • pp.360-363
    • /
    • 2020
  • We present the power of the correlated superposition coding (SC) in non-orthogonal multiple access (NOMA). This paper derives closed-form expressions for the total allocated power with the constant total transmitted power. It is shown that the total allocated power is the function of a correlation coefficient. In result, the correlated SC NOMA should be designed with consideration of the correlation coefficient.

열간압연중 압연하중 및 압연동력 예측 모델 (Evaluzation of Model equation Predicting Roll Force and Roll Power during Hot Rolling)

  • 곽우진;황상무
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 1999년도 제3회 압연심포지엄 논문집 압연기술의 미래개척 (Exploitation of Future Rolling Technologies)
    • /
    • pp.308-312
    • /
    • 1999
  • Developed the model equations which calculate roll force, roll power during hot rolling in real time. The variables which mainly effect on the roll force, roll power are shape factor, reduction, roll diameter, roll velocity, strip inlet temperature, carbon content of strip and strip-roll contact friction coefficient. Among these variables roll diameter, roll velocity, inlet temperature, carbon content and friction coefficient can be excluded in interpolated model equation by introducing equation of die force(F'), power(p') of the frictionless uniform plane strain compression which can be calculated without iteration. At the case of coulomb friction coefficient of 0.3, we evaluated coefficient of polynomial equations of {{{{ { F} over {F' } }}}}, {{{{ { Pf} over {Pd }, { Pd} over {P' } }}}} from the result of finite element analysis using interpolation. It was found that the change of values of {{{{ { F} over {F' }, { P} over {P' } }}}} with the friction coefficient tend to straight line which slope depend only on shape factor. With these properties, developed model equations could be extended to other values of coulomb friction coefficient. To verify developed roll force, roll power model equation we compared the results from these model equation with the results from these model equation with the results from finite element analysis in factory process condition.

  • PDF

화력발전의 신재생에너지 전환에 따른 경제적 파급효과 분석 (An Analysis of the Economic Effects of the New and Renewable Energy Transformation of Thermal Power Generation)

  • 임상수
    • 자원ㆍ환경경제연구
    • /
    • 제32권2호
    • /
    • pp.127-147
    • /
    • 2023
  • 본 연구는 정부의 탄소중립 정책 중 하나인 화력발전을 신재생에너지로 대체하는 경우 에 대한 경제적 파급효과를 분석하는 것을 목적으로 한다. 이러한 분석을 위해 화력발전을 신재생에너지로 100% 대체하는 경우를 시나리오 A로 설정하고, 60%로 대체하는 경우를 시나리오 B로 설정한다. 또한 이렇게 화력발전을 신재생에너지로 대체할 때 비용이 발생하게 되는데 현행과 동일한 비용인 경우를 시나리오 1, 현행보다 비용이 120% 증가한 경우를 시나리오 2로 설정한다. 따라서 화력발전을 신재생에너지로 전환할 때 시나리오는 크게 이와 같이 4가지 경우로 정리된다. 화력발전을 신재생에너지로 전환하는 경우, 화력발전의 생산유발계수는 시나리오와 관계없이 현행 수준보다 감소하는 것으로 나타났다. 그러나 화력발전을 신재생에너지로 100% 전환하는 경우 부가가치유발계수와 온실가스배출량 유발계수는 현행 수준보다 감소한 반면 화력발전을 신재생에너지로 60% 대체하는 경우 부가가치유발계수와 온실가스배출량 유발계수는 현행 수준보다 증가했다. 또한 대부분의 업종의 온실가스배출량 유발계수는 감소하는 것으로 나타난 반면 생산유발계수와 부가가치유발계수는 증가하는 것으로 나타났다. 정부 정책의 목적은 화력발전을 신재생에너지로 전환시켜 온실가스배출량을 축소시키는 것이기 때문에 시나리오 화력발전을 신재생에너지로 100% 전환하는 경우가 더 적합한 것으로 보인다. 다만, 이로 인해 일부 업종의 생산유발계수와 부가가치유발계수가 감소하는 부작용이 발생하므로 이를 해결하기 위한 정부의 지원 정책이 필요하다.

수리실험에 의한 조력발전용 수문의 유량계수 산정에 관한 고찰 (Study on the Estimation of Discharge Coefficient of Sluice for Tidal Power Generation by Performing Physical Experiment)

  • 오상호;이광수;이달수;장세철
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 추계학술대회 초록집
    • /
    • pp.160.1-160.1
    • /
    • 2011
  • In this study, the influence of methodology of assessing water levels on the discharge coefficient of sluice for tidal power generation was investigated. A physical experiment was performed in a planar open channel by installing 1/70 scale model of the sluice caisson in the planar open channel. In front of and behind the sluice model, sloping bathymetry was made to reproduce corresponding field condition. By analyzing the experimental results, it was found that the location of measuring water levels significantly affects the estimates of the discharge coefficient, due to the variability of the parameter according to the head difference between the measuring locations. Therefore, it is necessary to be careful in estimating and utilizing the discharge coefficient in the relevant study of a tidal power generation.

  • PDF

3차원 소형축류홴의 공력특성에 대한 난류모델평가 (Evaluation of the Turbulence Models on the Aerodynamic Performance of Three-Dimensional Small-Size Axial Fan)

  • 김장권;오석형
    • 동력기계공학회지
    • /
    • 제18권6호
    • /
    • pp.13-20
    • /
    • 2014
  • The steady-state, incompressible and three-dimensional numerical analysis was carried out to evaluate turbulent models on the aerodynamic performance of a small-size axial fan(SSAF). The prediction performance on the static pressure of all turbulent models is going downhill at the high static pressure and low flowrate region, but has improved at the axial flow region. In consequence, all turbulent models predict the static pressure coefficient with an error performance less than about 4% after the region of the flowrate coefficient of about 0.14. Especially, the turbulent model of SST $k-{\omega}$ shows the best prediction performance equivalent to an error performance less than about 2% on the static pressure.

Performance Improvement Strategy for Parallel-operated Virtual Synchronous Generators in Microgrids

  • Zhang, Hui;Zhang, Ruixue;Sun, Kai;Feng, Wei
    • Journal of Power Electronics
    • /
    • 제19권2호
    • /
    • pp.580-590
    • /
    • 2019
  • The concept of virtual synchronous generators (VSGs) is a valuable means for improving the frequency stability of microgrids (MGs). However, a great virtual inertia in a VSG's controller may cause power oscillation, thereby deteriorating system stability. In this study, a small-signal model of an MG with two paralleled VSGs is established, and a control strategy for maintaining a constant inertial time with an increasing active-frequency droop coefficient (m) is proposed on the basis of a root locus analysis. The power oscillation is suppressed by adjusting virtual synchronous reactance, damping coefficient, and load frequency coefficient under the same inertial time constant. In addition, the dynamic load distribution is sensitive to the controller parameters, especially under the parallel operation of VSGs with different capacities. Therefore, an active power increment method is introduced to improve the precision of active power sharing in dynamic response. Simulation and experimental is used to verify the theoretical analysis findings.

Determination of Critical Generator Group Using Accelerating Power and Synchronizing Power Coefficient in the Transient Energy Function Method

  • Chun, Yeong-Han
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권2호
    • /
    • pp.161-166
    • /
    • 2011
  • This paper proposes an algorithm for determining critical generator lists using accelerating power and synchronizing power coefficient (SPC), and critical generator group (CGG) from CGG candidates, which is a combination of critical generators. The accurate determination of CGG provides a more accurate energy margin while providing system operator with information of possible unstable generator group. Classical transient energy function (TEF) method selects the critical generators with big corrected kinetic energy of each generator at the moment of fault removal. However, the generator with small acceleration after fault, that is, the generator with small corrected kinetic energy, is also likely to belong to CGG if the generator has small synchronizing power. The proposed algorithm has been verified to be effective compared with the classical TEF method. We utilized the power system of Korean Electric Power Corporation(KEPCO) as a test system.