• 제목/요약/키워드: power breakdown

Search Result 919, Processing Time 0.027 seconds

The Process and Fabrication of 500 V Unified Trench Gate Power MOSFET (500 V급 Unified Trench Gate Power MOSFET 공정 및 제작에 관한 연구)

  • Kang, Ey-Goo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.10
    • /
    • pp.720-725
    • /
    • 2013
  • Power MOSFET operate voltage-driven devices, design to control the large power switching device for power supply, converter, motor control, etc. We have analyzed trench process, field limit ring process for fabrication of unified trench gate power MOSFET. And we have analyzed electrical characteristics of fabricated unified trench gate power MOSFET. The optimal trench process was based on SF6. After we carried out SEM measurement, we obtained superior trench gate and field limit ring process. And we compared electrical characteristics of planar and trench gate unified power MOSFET after completing device fabrication. As a result, the both of them was obtained 500 V breakdown voltage. However trench gate unified power MOSFET was shown improved Vth and on state voltage drop characteristics than planar gate unified power MOSFET.

Power system analysis and power consumption breakdown for an ac PDP system (AC PDP 시스템의 전원회로 해석과 소비전력 분석)

  • Ahn, Jae-Woo;Ha, Jung-Jun;Choi, Byung-Cho
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.446-449
    • /
    • 2001
  • This paper presents the results of the power system analysis and power loss breakdown peformed on a 40-inch ac plasma display panel (PDP) TV set. The architecture and function of power system is reviewed. The power flow inside the PDP TV set is presented, and the distribution of the power loss is analyzed. It was found that the sustain driver circuit and power factor correction (PFC) circuit are the two major sources of the power loss. The results of this paper can be used as a preliminary guideline to improve the architecture and efficiency of power systems for ac PDP application systems.

  • PDF

Adhesion properties and Breakdown behaviors of LSR Interface (LSR 계면의 접착특성 및 절연파괴거동)

  • Yoon, Seung-Hoon;Nam, Jin-Ho;Lee, Gun-Ju;Choi, Soo-Geol;Shin, Doo-Sung;Ji, Eung-Seo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.232-235
    • /
    • 2002
  • Recently developed liquid silicone rubber (LSR) can be cured by platinum catalyzed additional hydrosilylation mechanism and has the advantage of no byproduct compared to traditional millable peroxide curing silicone rubber. We investigated the characteristics of dielectric breakdown of silicone rubber and adhesion properties between semi-conductive LSR and insulating LSR for high voltage application of pre-molded joint (PMJ). In order to understand the dielectric breakdown characteristics, we used the sheet samples and the paired type rogowski insert electrode system. The breakdown strength and adhesion strength of LSR (E-3) were superior to those of several silicone rubbers. Adhesion strength could be improved by curing at high temperature without post-curing process or enhanced by post-curing process. When LSR (E-3) was cured at $(150^{\circ}C{\times}10min$ semi-conductive )${\times}$ ($175^{\circ}C{\times}10min$ insulation), it showed the high breakdown strength with low standard deviation, and good adhesion strength. In this results, we could apply this process to the fabrication of PMJ without post-curing.

  • PDF

Breakdown Characteristics of a Model Power Line in the Presence of Combustion Flame (연소화염 존재 시 모델 전력선의 절연파괴 특성)

  • Kim, In-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.10
    • /
    • pp.164-171
    • /
    • 2006
  • The results of an experimental investigation into the breakdown characteristics of a model power line in the presence of oil flame are reported under the application of 60[Hz] ac and dc high-voltages. It is appeared that flame can reduce by more than half, 80[%] in maximum, the breakdown voltage with the case of h=0 under ac and dc applications. Taking a horizontal model line with a k=0.5 of flame position, it can be seen from the results that the reduction of flashover levels, in comparison with the no-flame case, are 78.6[%] for h=0[cm], 59.7[%] for h=3[cm], 46.9[%] for h=6[cm], 41.5[%] for h=9[cm] and 35.4[%] for h=12[cm] when ac voltage is applied.

Stator Insulation Quality Assessment for High Voltage Motors Based on Probability Distributions

  • Kim, Hee-Dong;Kim, Chung-Hyo
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.4
    • /
    • pp.571-575
    • /
    • 2008
  • Stator insulation quality assessment for high voltage motors is a major issue for the reliable maintenance of industrial and power plants. To assess the condition of stator insulation, nondestructive tests were performed on the sixty coil groups of twelve motors. After completing the nondestructive tests, the AC voltage applied to the stator winding was gradually increased until insulation failure in order to obtain the breakdown voltage. The stator winding of each motor was classified into five coil groups; one group with healthy insulation and four groups with four different types of artificial defects. To analyze the breakdown voltage statistically, Weibull distribution was employed for the tests on the fifty coil groups of ten motors. The 50th percentile values of the measured breakdown voltages based on the statistical data of the five coil groups of ten motors were 26.1kV, 25.0kV, 24.4kV, 26.7kV and 30.5kV, respectively. Almost all of the failures were located in the line-end coil at the exit of the core slot. The breakdown voltages and the types of defects showed strong relation to the stator insulation tests such as in the case of dissipation factor and ac current. It is shown that the condition of the motor insulation can be determined from the relationship between the probability of failure and the type of defect.

Breakdown Voltage and On-resistance Analysis of Partial-isolation LDMOS (Partial-isolation LDMOS의 항복전압과 온저항 분석)

  • Sin-Wook Kim;Myoung-jin Lee
    • Journal of IKEEE
    • /
    • v.27 no.4
    • /
    • pp.567-572
    • /
    • 2023
  • In this paper, the breakdown voltage of Pi-LDMOS (Partial isolation lateral double diffused metal oxide semiconductor) was analyzed by simulation. Breakdown voltage variation is investigated under various settings of Parial buied oxide(P-BOX) parameters(length, thickness, location) and their mechanism is specified. In addition, the change in on-resistance in the breakdown voltage and trade-off relationship was analyzed according to the change in the P-BOX parameter, and the Figure-of-merit(FOM) was calculated and compared. In proposed structure, Lbox=5 ㎛, tbox=2 ㎛, and Lbc=2 ㎛ showed the highest breakdown voltage of 138V, and Lbox=5 ㎛, tbox=1.6 ㎛, and Lbc=2 ㎛ showed the highest FOM. Compared to conventional LDMOS, the breakdown voltage is 123% and FOM is 3.89 times improved. Therefore, Pi-LDMOS has a high breakdown voltage and FOM, which can contribute to the improvement of the stable operating range of the Power IC.

A study of AC/DC combined emergency source for power system control (전력계통 제어를 위한 변전소 AC/DC 겸용 비상전원에 관한 연구)

  • Jun, Bum-Bae;Lee, Hyoung-Han;Kim, Chang-Gon;Ahn, Bo-Soon;Yun, Ki-Seob;Jung, Jong-Ki
    • Proceedings of the KIEE Conference
    • /
    • 2005.11b
    • /
    • pp.135-138
    • /
    • 2005
  • This paper focuses on emergency source and control of substation against the consequence of power system breakdown or outage. the aim of the paper is to provide ideas and guidance concerning methods of using AC/DC combined emergency source for power system control to restore power system after unforseen events, such as outages caused by natural disaster. so the emergency source and lamp is very important for restoration control of substation after outage. therefore, this paper proposes countermeasure and method for security of substation emergency source and lamp which is restored at breakdown.

  • PDF

The Consideration of Electrical Characteristics and Breakdown Lifetime in 22.9[kV] Underground Distribution Power Cables (22.9[kV] 지중배전용 전력케이블의 전기적 특성과 파괴수명 고찰)

  • Kim, Chung-Bae;Hong, Gyeong-Jin;Im, Jang-Seop;Jeong, U-Seong;Kim, Sang-Jun;Kim, Tae-Seong
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.9
    • /
    • pp.628-633
    • /
    • 1999
  • Degradation diagnosis of XLPE insulated URD cables was accomplished through out new method, which was to be analyzed by non-electrical experiments and synthesized by degradation points. To supplement this method, It was also carried out using several electrical analyses. Tan$\delta$ had commonly a different tendency by means oftemperature and frequency and also appeared higher at the outer part rather than innerpart of insulator. PD-q increased generally in proportion to the applied voltage andshowed regular patterns in relation to the thickness of insulator. Breakdown voltageswere measured and breakdown lifetimes were predicted appling for Weibull distribution function. As a result, breakdown lifetime in failure cables was shorter up to$\fraction one-third$ times than that in general cables. It was very available to estimate cable degradation using above method, but it needs further study on XLPE insulated URD cables in order to improve reliability.

  • PDF

A Study on the Development of Optimal Alternative Selection Model to Renew Building Equipments System (건축설비시설의 갱신을 위한 최적 대체안 선정모델 개발에 관한 연구)

  • 윤동원;이정재;정광섭;한화택;정순성
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.10
    • /
    • pp.950-961
    • /
    • 2000
  • The objective of this study is to develop optimal alternative selection model for renewing building equipments system. Cost Breakdown Structure of LCC in HVAC systems are deduced from resonable data and factors. As for Cost Breakdown Structure of LCC in HVAC system, pertinent level, title, CBS number, and block number are determined efficiently. Especially, in addition to current cost factor, it is possible to make Cost Breakdown Structure using present worth method more clear. A model of POWER LCC ver 1.0 used to analyze primary cooling system, heating system, and air conditioning system are POWER LCC ver 1.0_/sub SYSTEM/ : C1+ C2- C3+ C4+ C5+ C6+ C7±C8+ C9- C10/sub -1/+ C10/sub -2/+ C10/sub -3/, and is implemented with consideration of Cost Breakdown Structure and their summation using present-worth method. It is programmed with one of scientific languages, MATLAB 5.3.

  • PDF

Dielectric Characteristics of Subcooled $LN_2$ for Insulation Design of HTS Fault Current Limiters (고온초전도 한류기의 절연설계를 위한 과냉각 액체질소의 절연내력 특성)

  • 백승명;정종만;김상현
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.2
    • /
    • pp.46-50
    • /
    • 2003
  • In the dielectric insulation design of any high temperature superconducting (HTS) apparatus as well as HTS fault current limiter in the electrical power systems, the breakdown characteristics of cryogenic coolants such as liquid nitrogen ($LN_2$) are an important factor of the insulating engineering. Previous reports concerned with the breakdown characteristics of liquid nitrogen have pointed out that bubbles and gaseous nitrogen have a treat influence on their breakdown phenomena, However, useful data for practical insulation design of HTS fault CUITent limiter operating at subcooled L$N_2$ have not been obtained enough. Therefore, this paper presents an experimental investigate of breakdown phenomena in liquid nitrogen under AC voltage, And, we observed the breakdown voltage (BDV) of liquid nitrogen with lowering temperature. The Weibull plots of the breakdown voltage of subcooled $LN_2$ for the needle-plane electrode with d= 10 mm are studied, The dependence of breakdown voltage for needle-plane and pancake coil-pancake coil electrode on temperature is illustrated, The relationship between the AC breakdown characteristics and the temperature were clarified.