• 제목/요약/키워드: power absorption

검색결과 849건 처리시간 0.028초

전력기기용 탄성형 에폭시의 흡습에 따른 절연 특성 (Insulation Properties of Epoxy Resin to Elastomer Contents for Power Electrical Machine according to Moisture Absorption)

  • 김석재;박성희;전용식;강성화;박대희;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 추계학술대회 논문집 Vol.17
    • /
    • pp.297-300
    • /
    • 2004
  • In this paper, we investigated insulation property of epoxy resin which includes elastomers to improve mechanical property, as varied to additive elastomer contents and to moisture absorption. There are four samples with 5[phr], 10[phr], 15[phr] and 20[phr]. we experimented to acquire insulation property(absorption rate, dissolution rate, apparent rate) and electrical property(perittivity, $tan\delta$, BDV) during respectively the time such as 6[h], 12[h], 18[h], 24[h] for moisture absorption. According to the experimental results, it is appeared that when the additive elastomer contents are increasing or when specimens remain more moisture, absorption rate, dissolution rate, permittivity and $tan\delta$ are slightly increasing but apparent rate and BDV(break-Down Voltage) strength are decreasing in particular, elastomer content [20]phr appeared remarkedly the more increase or decrease than others.

  • PDF

가정용 흡수식 냉난방기 개발을 위한 재생기 성능실험 (Performance Experiment of Generator for Household Absorption Chiller and Heater)

  • 유선일;권오경;윤정인
    • 대한기계학회논문집B
    • /
    • 제23권10호
    • /
    • pp.1347-1354
    • /
    • 1999
  • Recently, the markets of the air conditioner are enlarging. The market size will reach 2.0 billion won in 2000. Electric heat pumps have been utilized as main residential air conditioners. especially in Korea. They cause a surge up electric power demand during summer. Moreover, the use of HCFCs and HFCs causes serious problem to the global environment such as global warming and ozone layer destruction. Absorption chiller and heater could solve such problems. It was built and tested for analyzing the performance of the generator for absorption chiller and heater. Experiment was done with a high temperature generator, a low temperature generator, heat exchangers, a condenser and a solution tank. It was tested that the double effect series flow cycle with two kinds of solution cycle. Solution cycle B showed better than solution cycle A. Two kinds of heat exchanger were used, where one's heat transfer area is bigger than the other. Bigger one increased a little performance of absorption chiller and heater. But it was not economical. From this study, we got that the coefficient of performance(COP) is 0.82 and the capacity is 7.24 kW for an absorption chiller and heater.

Performance improvement of countercurrent-flow membrane gas absorption in a hollow fiber gas-liquid membrane contactor

  • Ho, Chii-Dong;Sung, Yun-Jen;Chen, Wei-Ting;Tsai, Feng-Chi
    • Membrane and Water Treatment
    • /
    • 제8권1호
    • /
    • pp.35-50
    • /
    • 2017
  • The theoretical membrane gas absorption module treatments in a hollow fiber gas-liquid membrane contactor using Happel's free surface model were obtained under countercurrent-flow operations. The analytical solutions were obtained using the separated variable method with an orthogonal expansion technique extended in power series. The $CO_2$ concentration in the liquid absorbent, total absorption rate and absorption efficiency were calculated theoretically and experimentally with the liquid absorbent flow rate, gas feed flow rate and initial $CO_2$ concentration in the gas feed as parameters. The improvements in device performance under countercurrent-flow operations to increase the absorption efficiency in a carbon dioxide and nitrogen gas feed mixture using a pure water liquid absorbent were achieved and compared with those in the concurrent-flow operation. Both good qualitative and quantitative agreements were achieved between the experimental results and theoretical predictions for countercurrent flow in a hollow fiber gas-liquid membrane contactor with accuracy of $6.62{\times}10^{-2}{\leq}E{\leq}8.98{\times}10^{-2}$.

Study on the Cavitation Damage of Cupronickel(70/30) Tube for Gas Absorption Refrigeration Machine

  • Lim, Uh-Joh;Jeong, Ki-Cheol;Yun, Byoung-Du
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권2호
    • /
    • pp.332-337
    • /
    • 2004
  • The use of gas absorption refrigeration machine has considerably increased because of the shortage of the electric power in the summer and the regulation of freon refrigerant. Gas absorption refrigeration machine consists of a condenser, a heat exchanger. supplying pipes, a radiator etc, This system is likely to be corroded by acid. dissolved oxygen and gases, Cavitation erosion-corrosion by flow velocity of cooling water may happen in absorption refrigeration machine. In these cases. erosion and corrosion occur simultaneously. Then, it makes a serious damage with synergy effect. Therefore, this paper was studied on the cavitation damage of cupronickel(70/30) tube for gas absorption refrigeration machine, In the $30^{\circ}C$ tap water, linear polarization test and anodic polarization test were carried out for copper(C1220T-OL) and cupronickel(70/30) tube. Also, cavitation erosion-corrosion behavior of cupronickel (70/30) tube was considered, The main results are as following: (1) In the linear test, the corrosion current density of cupronickel(70/30) is higher than that of copper. (2) The erosion-corrosion rate of cupronickel(70/30) displayed later tendency than that of copper by vibratory cavitation in cooling water. (3) In cooling water, the progress mechanism of erosion-corrosion rate of copper and cupronickel(70/30) follows a pattern of incubation, acceleration, attenuation and a steady state period.

태양열에 의한 냉방 및 난방시스템의 성능향상(II) - 태양열을 이용한 흡수식 냉동기의 성능 - (The Improvement of the Performance of Solar Cooling and Heating Systems (II) - The Characteristics of an Absorption Refrigeration Powered by Solar Systems -)

  • 박문수;김무근;김효경;노승탁
    • 설비공학논문집
    • /
    • 제1권1호
    • /
    • pp.46-54
    • /
    • 1989
  • The purpose of this study is to obtain the dynamic characteristics of an absorption refrigerator powered by solar energy by experiments. Since the absorption refrigerator power by solar energy should have the characteristics which is suitable for the intermittence and rarity of solar energy, not only the characteristics of the steady state operations but also the partial load and the transient operations should be considered. The minimum available temperature of the storage tank should be known, and the absorption refrigerator can be suitably selected for air-conditioning systems. In this study, the experimental data of the transient state for on-off and warming-up operations has been obtained. Also the experiments are performed which test the minimum available temperature of the storage tank. The results show that it takes 1 hour to get to the steady state of the absorption refrigerator, and the minimum available temperature of the storage tank is about $68^{\circ}C$, and show that in the partial load operations the performance of the absorption refrigerator is improved by applying the modified control method to on-off operations.

  • PDF

다이오드 레이저를 이용한 광흡수 농도 계측 기법 (I) (Species Concentration Measurement Using Diode Laser Absorption Spectroscopy (I))

  • 안재현;김용모;김세원
    • 한국연소학회지
    • /
    • 제9권3호
    • /
    • pp.27-35
    • /
    • 2004
  • Diode laser absorption sensors are advantageous because they may provide fast, sensitive, absolute, and selective measurements of species concentration. These systems are very attractive for practical applications owing to its compactness, resonable cost, robustness, and ease of use. In addition, diode lasers are fiber-optic compatible and thus enable simultaneous measurements of multiple species along a line-of-sight. Recent advances of room-temperature, near-IR and visible diode laser sources for telecommunication, optical data storage applications make it possible to be applied for combustion diagnostics based on diode laser absorption spectroscopy. Therefore, combined with fiber-optics and high sensitive detection strategies, compact and portable sensor systems are now appearing for variety of applications. The objectives of this research are to develope a new gas sensing system and to verify feasibility of this system. Wavelength and power characteristics as a function of injection current and temperature are experimentally found out. Direct absorption spectroscopy has been demonstrated in these experiments and has a bright prospect to this diode laser system.

  • PDF

전계흡수형 도파로에서 광전류를 이용한 전계에 따른 흡수변화의 측정 (Measurement of field-induced absorption changes in an electroabsorption waveguide using photocurrent)

  • 강병권;박승한;최중길
    • 한국광학회지
    • /
    • 제10권3호
    • /
    • pp.254-258
    • /
    • 1999
  • 전계흡수형 반도체 광도파로에서 흡수된 빛에 의해 발생된 광전류는 전파되는 파장에 따라 Fabry-Perot 모드의 간섭패턴을 나타냄을 보이고, 이로부터 인가전압에 따른 흡수계수의 변화를 측정할 수 있는 방법을 제시하였다. 광전류 신호는 파장에 따라 공명 반공명을 반복해서 나타내며 그 진폭은 흡수계수의 크기에 의존하므로 전계에 따른 흡수계수의 변화량을 측정 할 수 있었고, 1.55 $\mu\textrm{m}$ 파장에서 역전압 1.5V 인가시 bulk in GaAsP의 흡수계수 변화는 대략 157cm-1임을 알 수 있었다.

  • PDF

화학흡수법에 의한 연소폐가스 중 지구온난화 가스 $CO_2$분리에 관한 연구 (A Study on the Separation of $CO_2$from Flue Gas by Chemical Absorption)

  • 안성우;김영국;송호철;박진원
    • 에너지공학
    • /
    • 제6권2호
    • /
    • pp.203-211
    • /
    • 1997
  • 본 연구에서는 지구 온난화 연소폐가스를 모델로 한 $CO_2$-$N_2$혼합 기체의 화학흡수법에 의한 기체 분리 실험을 행하였다. 반회분식 기포부상 반응 장치를 이용하여 최적흡수액의 조건을 탐색하였고, 충진 흡수탑을 이용하여 흡수 속도를 측정, 실험 결과를 이론적 예측값과 비교.분석하여 흡수현상에 대한 적절한 해석을 하고자 하였다. 본 실험에 사용한 흡수제는 Monoethanolamine(MEA)이었고, 대상 기체는 화력발전소의 연소배가스의 주요성분이 $N_2$79%, $CO_2$15%, $O_2$4%인바, $N_2$: $CO_2$가 몰비 85:15의 비율인 모델가스를 혼합기체로 사용하였다. 실험조건하에서 $CO_2$loading과 $CO_2$제거율을 측정하였고, 흡수속도를 구하기 위하여 Enhancement factor를 도입하고 Film 모델과 Higbie 모델을 적용하였다. 흡수액의 최적농도는 4-5 M인 것으로 나타났으며. Higbie model에 의한 흡수속도 예측은 실측치와 잘 일치하여 연소폐가스 중의 고농도 $CO_2$가스의 흡수에 적용이 가능한 것으로 나타났다.

  • PDF

Multi Axis DOAS를 이용한 대기미량 물질 원격 측정 (Remote Sensing of Atmospheric Trace Species using Multi Axis Differential Optical Absorption Spectroscopy)

  • 이철규;김영준
    • 대한원격탐사학회지
    • /
    • 제22권2호
    • /
    • pp.141-151
    • /
    • 2006
  • 태양광을 광원으로 하고 천정방향을 포함한 다양한 고도각을 이용하는 자외선/가시광선영역에서의 흡수분광학이 최근에 지상용 대기원격 측정에 개발되어오고 있다. 이를 이용하여 지표부근에 존재하는 대기 미량 물질의 공간적 분포가 유추될 수 있다. 대기질 측정기술 중 하나인 MAX-DOAS (Multi-axis Differential Optical Absorption Spectroscopy) 기술은 광원으로서 태양산란광을 이용하고, 다양한 고도각에서 태양산란광을 기록하고 분석을 통하여 대기 중 미량 물질을 측정한다. 광주과학기술원 환경모니터링 신기술 연구센터에서 개발된 MAX-DOAS 시스템은 9004년 1월, 5월, 10월에 각각 도시대기, 화산플룸, 화력발전소 플룸의 측정에 적용되었다. 각각의 경우에 $SO_2,\;NO_2,\;BrO,\;O_4$를 정량분석하기 위하여 기록된 MAX-DOAS 스펙트럼은 자외선/가시광선 영역에서의 고유 흡수스펙트럼을 이용한 DOAS 기술을 이용하여 분석 되었다. 그 결과는 Slant Column Density (SCD)로 표현되었다. 플룸 측정의 경우에서는 플룸 속에 포함된 $NO_2,\;SO_2$의 공간적 분포를 파악하기 위하여 플룸의 진행방향과 수직적인 방향에서 MAX-DOAS 스캔이 이루어졌다. 이를 통하여 얻은 단면적을 토대로 $SO_2,\;NO_2$ 농도가 계산되었다. 화산플룸에서 $SO_2$는 580ppbv, 화력발전소 플룸에서 $NO_2$는 337ppbv, $SO_2$는 227ppbv 로 계산되었다.