• 제목/요약/키워드: potential shear strength

검색결과 154건 처리시간 0.025초

기존의 액상화 평가기법 밀 그 적용성에 관한 연구 (A Study on the Conventional Liquefaction Analysis and Application to Korean Liquefaction Hazard Zones)

  • 박인준;신윤섭;최재순;김수일
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1999년도 봄 학술발표회 논문집
    • /
    • pp.431-438
    • /
    • 1999
  • An assessment of liquefaction potential is made in principle by comparing the shear stress induced by earthquake to the liquefaction strength of the soil. In this study, a modified method based on Seed and Idriss theory is developed for evaluating liquefaction potential. The shear stress in the ground can be evaluated with seismic response analysis and the liquefaction strength of the soil can be investigated by using cyclic triaxial tests. The cyclic triaxial tests are conducted in two different conditions in order to investigate the factors affecting liquefaction strength such as cyclic shear stress amplitude and relative density. And performance of the modified method in practical examples is demonstrated by applying it to liquefaction analysis of artificial zones with dimensions and material properties similar to those in a typical field. From the result, the modified method for assessing liquefaction potential can successfully evaluate the safety factor under moderate magnitude(M=6.5) of earthquake.

  • PDF

휨항복 후 전단 파괴하는 철근콘크리트 보의 전단성능 저하에 관한 연구 (Shear Deterioration of Reinforced Concrete Beams Failing in Shear after Flexural Yielding)

  • 이정윤
    • 콘크리트학회논문집
    • /
    • 제13권5호
    • /
    • pp.466-475
    • /
    • 2001
  • 휨항복 후 전단 파괴하는 철근콘크리트 보의 전단 성능 저하가 예측되었다. 휨항복 후 철근콘크리트 보에는 소성 힌지 구간이 형성되며 축방향 변형률이 급격히 증가한다. 축방향 변형률이 급격히 증가함에 따라 콘크리트 유효 압축 강도가 감소하며 철근콘크리트 보의 잠재 전단 강도는 감소한다. 제안된 전단 성능 저하 예측법은 이와 같은 휨항복 후 전단 파괴하는 철근콘크리트 보의 전단 파괴 특성을 고려한 트러스 모델에 기본을 두고 있다. 해석에서는 철근콘크리트 보의 실제 부재 축방향 변형률 $\varepsilon$x 값을 RA-STM에 대입하여 고정한 후에 그 부재의 잠재 전단 강도를 구하였다. 주어진 $\varepsilon$x값의 증가에 의하여 보의 잠재 전단 강도가 휨항복 시의 전단력에 도달할 때의 부재 변형 능력을 그 부재의 최대 연성 능력으로 하였다. 예측된 부재 변형 능력은 보통강도 콘크리트를 사용한 시험체의 부재 변형 능력을 최대 35% 과소 평가하였지만, 그 차이는 전단보강근의 양이 증가함에 따라서 감소하였다. 고강도 콘크리트를 사용한 시험체에 대하여 예측된 부재 변형 능력은 실제 부재 변형 능력을 최대 20% 과대 평가하였다. 철근콘크리트 보의 전단 변형 능력의 예측은 콘크리트의 유효 압축 강도νf ck와 밀접한 관계가 있어 보의 전단 변형 능력을 보다 정확히 예측하기 위해서는 사인장 균열과 직각 되는 방향의 변형률 $\varepsilon$$_1$가 큰 경우의 νf ck 에 대한 연구가 필요하다고 사료된다.

진동삼축시험에 기초한 액상화 평가 (Assessment of Liquefaction Potential based on the Cyclic Triaxial Test)

  • 최재순
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 1999년도 춘계 학술발표회 논문집 Proceedings of EESK Conference-Spring
    • /
    • pp.77-84
    • /
    • 1999
  • An assessment of liquefaction potential is made in principle by comparing earthquake induced shear stress to the liquefaction strength of the soil. In this research a modified method based on Seed and Idriss theory is developed for evaluating liquefaction strength of Jumunjon sand(Korean standard sand). Also the factors affecting liquefaction strenght such as cyclic shear stress amplitude and relative density are investigated and verified by using cyclic triaxial test. From the result the new relationships between cyclic shear stress ratio and number of load cycles are proposed for evaluating liquefaction strength under moderated magnitude(M=6.5) of earthquake.

  • PDF

Fuzzy modelling approach for shear strength prediction of RC deep beams

  • Mohammadhassani, Mohammad;Saleh, Aidi MD.;Suhatril, M;Safa, M.
    • Smart Structures and Systems
    • /
    • 제16권3호
    • /
    • pp.497-519
    • /
    • 2015
  • This study discusses the use of Adaptive-Network-Based-Fuzzy-Inference-System (ANFIS) in predicting the shear strength of reinforced-concrete deep beams. 139 experimental data have been collected from renowned publications on simply supported high strength concrete deep beams. The results show that the ANFIS has strong potential as a feasible tool for predicting the shear strength of deep beams within the range of the considered input parameters. ANFIS's results are highly accurate, precise and therefore, more satisfactory. Based on the Sensitivity analysis, the shear span to depth ratio (a/d) and concrete cylinder strength ($f_c^{\prime}$) have major influence on the shear strength prediction of deep beams. The parametric study confirms the increase in shear strength of deep beams with an equal increase in the concrete strength and decrease in the shear span to-depth-ratio.

Shear strength of steel fiber reinforced concrete deep beams without stirrups

  • Birincioglu, Mustafa I.;Keskin, Riza S.O.;Arslan, Guray
    • Advances in concrete construction
    • /
    • 제13권1호
    • /
    • pp.1-10
    • /
    • 2022
  • Concrete is a brittle material and weak in tension. Traditionally, web reinforcement in the form of vertical stirrups is used in reinforced concrete (RC) beams to take care of principal stresses that may cause failure when they are subjected to shear stresses. In recent decades, the potential of various types of fibers for improving post-cracking behavior of RC beams and replacing stirrups completely or partially have been studied. It has been shown that the use of steel fibers randomly dispersed and oriented in concrete has a significant potential for enhancing mechanical properties of RC beams. However, the studies on deep steel fiber reinforced concrete (SFRC) beams are limited when compared to those focusing on slender beams. An experimental program consisting of three RC and nine SFRC deep beams without stirrups were conducted in this study. Besides, various models developed for predicting the ultimate shear strength and diagonal cracking strength of SFRC deep beams without stirrups were applied to experimental data obtained from the literature and this study.

Static behavior of high strength friction-grip bolt shear connectors in composite beams

  • Xing, Ying;Liu, Yanbin;Shi, Caijun;Wang, Zhipeng;Guo, Qi;Jiao, Jinfeng
    • Steel and Composite Structures
    • /
    • 제42권3호
    • /
    • pp.407-426
    • /
    • 2022
  • Superior to traditional welded studs, high strength friction-grip bolted shear connectors facilitate the assembling and demounting of the composite members, which maximizes the potential for efficiency in the construction and retrofitting of new and old structures respectively. Hence, it is necessary to investigate the structural properties of high strength friction-grip bolts used in steel concrete composite beams. By means of push-out tests, an experimental study was conducted on post-installed high strength friction-grip bolts, considering the effects of different bolt size, concrete strength, bolt tensile strength and bolt pretension. The test results showed that bolt shear fracture was the dominant failure mode of all specimens. Based on the load-slip curves, uplifting curves and bolt tensile force curves between the precast concrete slab and steel beam obtained by push-out tests, the anti-slip performance of steel-concrete interface and shear behavior of bolt shank were studied, including the quantitative analysis of anti-slip load, and anti-slip stiffness, frictional coefficient, shear stiffness of bolt shank and ultimate shear capacity. Meanwhile, the interfacial anti-slip stiffness and shear stiffness of bolt shank were defined reasonably. In addition, a total of 56 push-out finite element models verified by the experimental results were also developed, and used to conduct parametric analyses for investigating the shear behavior of high-strength bolted shear connectors in steel-concrete composite beams. Finally, on ground of the test results and finite element simulation analysis, a new design formula for predicting shear capacity was proposed by nonlinear fitting, considering the bolt diameter, concrete strength and bolt tensile strength. Comparison of the calculated value from proposed formula and test results given in the relevant references indicated that the proposed formulas can give a reasonable prediction.

Analysis of punching shear in high strength RC panels-experiments, comparison with codes and FEM results

  • Shuraim, Ahmed B.;Aslam, Fahid;Hussain, Raja R.;Alhozaimy, Abdulrahman M.
    • Computers and Concrete
    • /
    • 제17권6호
    • /
    • pp.739-760
    • /
    • 2016
  • This paper reports on punching shear behavior of reinforced concrete panels, investigated experimentally and through finite element simulation. The aim of the study was to examine the punching shear of high strength concrete panels incorporating different types of aggregate and silica fume, in order to assess the validity of the existing code models with respect to the role of compressive and tensile strength of high strength concrete. The variables in concrete mix design include three types of coarse aggregates and three water-cementitious ratios, and ten-percent replacement of silica fume. The experimental results were compared with the results produced by empirical prediction equations of a number of widely used codes of practice. The prediction of the punching shear capacity of high strength concrete using the equations listed in this study, pointed to a potential unsafe design in some of them. This may be a reflection of the overestimation of the contribution of compressive strength and the negligence of the role of flexural reinforcement. The overall findings clearly indicated that the extrapolation of the relationships that were developed for normal strength concrete are not valid for high strength concrete within the scope of this study and that finite element simulation can provide a better alternative to empirical code Equations.

Monotonic behavior of C and L shaped angle shear connectors within steel-concrete composite beams: an experimental investigation

  • Shariati, Mahdi;Tahmasbi, Farzad;Mehrabi, Peyman;Bahadori, Alireza;Toghroli, Ali
    • Steel and Composite Structures
    • /
    • 제35권2호
    • /
    • pp.237-247
    • /
    • 2020
  • Shear connectors are essential elements in the design of steel-concrete composite systems. These connectors are utilized to prevent the occurrence of potential slips at the interface of steel and concrete. The two types of shear connectors which have been recently employed in construction projects are C- and L-shaped connectors. In the current study, the behavior of C and L-shaped angle shear connectors is investigated experimentally. For this purpose, eight push-out tests were composed and subjected to monotonic loading. The load-slip curves and failure modes have been determined. Also, the shear strength of the connectors has been compared with previously developed relationships. Two failure modes of shear connectors were observed: 1) concrete crushing-splitting and 2) shear connector fracture. It was found that the L-shaped connectors have less shear strength compared to C-shaped connectors, and decreasing the angle leg size increases the shear strength of the C-shaped connectors, but decreases the relative ductility and strength of L-shaped connectors.

Strain interaction of steel stirrup and EB-FRP web strip in shear-strengthened semi-deep concrete beams

  • Javad Mokari Rahmdel;Erfan Shafei
    • Steel and Composite Structures
    • /
    • 제47권3호
    • /
    • pp.383-393
    • /
    • 2023
  • Conventional reinforced concrete design codes assume ideal strain evolution in semi-deep beams with externally bonded fiber-reinforced polymer (EB-FRP) web strips. However, there is a strain interaction between internal stirrups and web strips, leading to a notable difference between code-based and experimental shear strengths. Current study provides an experiment-verified detailed numerical framework to assess the potential strain interaction under quasi-static monotonic load. Based on the observations, steel stirrups are effective only for low EB-FRP amounts and the over-strengthening of semi-deep beams prevents the stirrups from yielding, reducing its shear strength contribution. A notable difference is detected between the code-based and the study-based EB-FRP strain values, which is a function of the normalized FRP stress parameter. Semi-analytical relations are proposed to estimate the effective strain and stress of the components considering the potential strain interaction. For the sake of simplification, a linearized correction factor is proposed for the EB-FRP web strip strain, assuming its restraining effect as constant for all steel stirrup amounts.

Potential of adaptive neuro fuzzy inference system for evaluating the factors affecting steel-concrete composite beam's shear strength

  • Safa, M.;Shariati, M.;Ibrahim, Z.;Toghroli, A.;Baharom, Shahrizan Bin;Nor, Norazman M.;Petkovic, Dalibor
    • Steel and Composite Structures
    • /
    • 제21권3호
    • /
    • pp.679-688
    • /
    • 2016
  • Structural design of a composite beam is influenced by two main factors, strength and ductility. For the design to be effective for a composite beam, say an RC slab and a steel I beam, the shear strength of the composite beam and ductility have to carefully estimate with the help of displacements between the two members. In this investigation the shear strengths of steel-concrete composite beams was analyzed based on the respective variable parameters. The methodology used by ANFIS (Adaptive Neuro Fuzzy Inference System) has been adopted for this purpose. The detection of the predominant factors affecting the shear strength steel-concrete composite beam was achieved by use of ANFIS process for variable selection. The results show that concrete compression strength has the highest influence on the shear strength capacity of composite beam.