• Title/Summary/Keyword: potential radiation dose

Search Result 199, Processing Time 0.026 seconds

Radiation-induced Pulmonary Toxicity following Adjuvant Radiotherapy for Breast Cancer (유방암 환자에서 보조적 방사선치료 후의 폐 손상)

  • Moon, Sung-Ho;Kim, Tae-Jung;Eom, Keun-Young;Kim, Jee-Hyun;Kim, Sung-Won;Kim, Jae-Sung;Kim, In-Ah
    • Radiation Oncology Journal
    • /
    • v.25 no.2
    • /
    • pp.109-117
    • /
    • 2007
  • [ $\underline{Purpose}$ ]: To evaluate the incidences and potential predictive factors for symptomatic radiation pneumonitis (SRP) and radiographic pulmonary toxicity (RPT) following adjuvant radiotherapy (RT) for patients with breast cancer. A particular focus was made to correlate RPT with the dose volume histogram (DVH) parameters based on three-dimensional RT planning (3D-RTP) data. $\underline{Materials\;and\;Methods}$: From September 2003 through February 2006, 171 patients with breast cancer were treated with adjuvant RT following breast surgery. A radiation dose of 50.4 Gy was delivered with tangential photon fields on the whole breast or chest wall. A single anterior oblique photon field for supraclavicular (SCL) nodes was added if indicated. Serial follow-up chest radiographs were reviewed by a chest radiologist. Radiation Therapy Oncology Group (RTOG) toxicity criteria were used for grading SRP and a modified World Health Organization (WHO) grading system was used to evaluate RPT. The overall percentage of the ipsilateral lung volume that received ${\geq}15\;Gy\;(V_{15}),\;20\;Gy\;(V_{20})$, and $30\;Gy\;(V_{30})$ and the mean lung dose (MLD) were calculated. We divided the ipsilateral lung into two territories, and defined separate DVH parameters, i.e., $V_{15\;TNGT},\;V_{20\;TNGT},\;V_{30\;TNGT},\;MLD_{TNGT}$, and $V_{15\;SCL},\;V_{20\;SCL},\;V_{30SCL},\;MLD_{SCL}$ to assess the relationship between these parameters and RPT. $\underline{Results}$: Four patients (2.1%) developed SRP (three with grade 3 and one with grade 2, respectively). There was no significant association of SRP with clinical parameters such as, age, pre-existing lung disease, smoking, chemotherapy, hormonal therapy and regional RT. When 137 patients treated with 3D-RTP were evaluated, 13.9% developed RPT in the tangent (TNGT) territory and 49.2% of 59 patients with regional RT developed RPT in the SCL territory. Regional RT (p<0.001) and age (p=0.039) was significantly correlated with RPT. All DVH parameters except for $V_{15\;TNGT}$ showed a significant correlation with RPT (p<0.05). $MLD_{TNGT}$ was a better predictor for RPT for the TNGT territory than $V_{15\;SCL}$ for the SCL territory. $\underline{Conclusion}$: The incidence of SRP was acceptable with the RT technique that was used. Age and regional RT were significant factors to predict RPT. The DVH parameter was good predictor for RPT for the SCL territory while $MLD_{TNGT}$ was a better predictor for RPT for the TNGT territory.

Organ Weights and Splenocytic Apoptosis in γ-irradiated Korean Dark-Striped Field Mice, Apodemus Agrarius Coreae (방사선 조사된 국내 야생 등줄쥐 (Apodemus agrarius coreae) 장기무게 및 비장세포 세포고사)

  • Joo, Hyunjin;Choi, Hoon;Yang, Kwang-hee;Keum, Dong-kwon;Kim, Hee sun
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.3
    • /
    • pp.168-173
    • /
    • 2015
  • The present investigation was planned to estimate potential possibility of striped field mice, Apodemus agrarius coreae (A. a. coreae), as a biological dosimeter in radio-environmental ecology. We bred captured wild A. a. coreae at laboratory and classified taxonomically based on external, cranial and tooth characters. Organ weights and splenocytic apoptosis were observed in order to establish a basic data on radiation biology of A. a. coreae (male, 40 weeks old). The biological effects was observed at 24hrs following irradiation (doses : 0, 0.5, 1, 2 Gy, dose rate : $0.8Gymin^{-1}$, $^{137}Cs$). Only thymus weights was significantly decreased. Splenocytic apoptosis was increased after irradiation. But splenocytic apoptosis was decreased in 0.5 Gy ${\gamma}$-irradiated mice compared to those of 0, 1, 2 Gy (P < 0.05). These data suggested that events in thymus and spleen of Korean dark-striped field mice, A. a. coreae THOMAS, could be a potential radio-biological indicator in human environments.

A Prospective Randomized Comparative Clinical Trial Comparing the Efficacy between Ondansetron and Metoclopramide for Prevention of Nausea and Vomiting in Patients Undergoing Fractionated Radiotherapy to the Abdominal Region (복부 방사선치료를 받는 환자에서 발생하는 오심 및 구토에 대한 온단세트론과 메토클로프라미드의 효과 : 제 3상 전향적 무작위 비교임상시험)

  • Park Hee Chul;Suh Chang Ok;Seong Jinsil;Cho Jae Ho;Lim John Jihoon;Park Won;Song Jae Seok;Kim Gwi Eon
    • Radiation Oncology Journal
    • /
    • v.19 no.2
    • /
    • pp.127-135
    • /
    • 2001
  • Purpose : This study is a prospective randomized clinical trial comparing the efficacy and complication of anti-emetic drugs for prevention of nausea and vomiting after radiotherapy which has moderate emetogenic potential. The aim of this study was to investigate whether the anti-emetic efficacy of ondansetron $(Zofran^{\circledR})$ 8 mg bid dose (Group O) is better than the efficacy of metoclopramide 5 mg lid dose (Group M) in patients undergoing fractionated radiotherapy to the abdominal region. Materials and Methods : Study entry was restricted to those patients who met the following eligibility criteria: histologically confirmed malignant disease; no distant metastasis; performance status of not more than ECOG grade 2; no previous chemotherapy and radiotherapy. Between March 1997 and February 1998, 60 patients enrolled in this study. All patients signed a written statement of informed consent prior to enrollment. Blinding was maintained by dosing identical number of tablets including one dose of matching placebo for Group O. The extent of nausea, appetite loss, and the number of emetic episodes were recorded everyday using diary card. The mean score of nausea, appetite loss and the mean number of emetic episodes were obtained in a weekly interval. Results : Prescription error occurred in one patient. And diary cards have not returned in 3 patients due to premature refusal of treatment. Card from one patient was excluded from the analysis because she had a history of treatment for neurosis. As a result, the analysis consisted of 55 patients. Patient characteristics and radiotherapy characteristics were similar except mean age was $52.9{\pm}11.2$ in group M, $46.5{\pm}9.5$ in group O. The difference of age was statistically significant. The mean score of nausea, appetite loss and emetic episodes in a weekly interval was higher in group M than O. In group M, the symptoms were most significant at 5th week. In a panel data analysis using mixed procedure, treatment group was only significant factor detecting the difference of weekly score for all three symptoms. Ondansetron $(Zofran^{\circledR})$ 8 mg bid dose and metoclopramide 5 mg lid dose were well tolerated without significant side effects. There were no clinically important changes In vital signs or clinical laboratory parameters with either drug. Conclusion : Concerning the fact that patients with younger age have higher emetogenic potential, there are possibilities that age difference between two treatment groups lowered the statistical power of analysis. There were significant difference favoring ondansetron group with respect to the severity of nausea, vomiting and loss of appetite. We concluded that ondansetron is more effective anti-emetic agents in the control of radiotherapy-induced nausea, vomiting, loss of appetite without significant toxicity, compared with commonly used drug, i.e., metoclopramide. However, there were patients suffering emesis despite the administration of ondansetron. The possible strategies to improve the prevention and the treatment of radiotherapy-induced emesis must be further studied.

  • PDF

Characterization and Preparation of the Hydrogel has Excellent Release Effect of the Active Ingredients Using a Radiation Cross-linking Technology (방사선 가교 기술을 이용한 유효성분 방출력이 우수한 하이드로겔 제조 및 특성 분석)

  • Hwang, Seung-Hyun;Ahn, Sung-Jun;Park, Jong-Seok;Jeong, Sung In;Gwon, Hui-Jeong;Lee, Dong Yun;Lim, Youn-Mook
    • Journal of Radiation Industry
    • /
    • v.9 no.4
    • /
    • pp.199-207
    • /
    • 2015
  • Typical radiation cross-linked hydrogels has the characteristic that high water content, but low emission efficiency of active ingredients. Therefore, the hydrogel was prepared by the addition to collagen, which is closely related to the formation of skin wrinkles in biocompatibility and highly water-soluble carboxymethyl cellulose sodium salt (CMC) in order to preparation of hydrogels has excellent emission efficiency of active ingredients. Hydrogels were prepared by dissolving CMC and collagen each of 0.5%, 10% concentration in deionized water. Then, prepared hydrogels are performed by gamma-radiation at 1, 3, 5 kGy irradiation dose. The results showed that the gel fraction of after irradiated 3 kGy hydrogel was higher than before irradiated gelation as long as the 55.3%. The swelling rate of irradiated 3 kGy hydrogel was lower than the non-irradiated sample. The compressive strength of 3 kGy irradiated hydrogel was the highest. The visco-elastic did not show any significant differences, even after irradiation. The CMC hydrogel in this study suggested a potential use as a material for the mask pack for improved emission efficiency of the active ingredient and anti-wrinkles.

An intelligent optimization method for the HCSB blanket based on an improved multi-objective NSGA-III algorithm and an adaptive BP neural network

  • Wen Zhou;Guomin Sun;Shuichiro Miwa;Zihui Yang;Zhuang Li;Di Zhang;Jianye Wang
    • Nuclear Engineering and Technology
    • /
    • v.55 no.9
    • /
    • pp.3150-3163
    • /
    • 2023
  • To improve the performance of blanket: maximizing the tritium breeding rate (TBR) for tritium self-sufficiency, and minimizing the Dose of backplate for radiation protection, most previous studies are based on manual corrections to adjust the blanket structure to achieve optimization design, but it is difficult to find an optimal structure and tends to be trapped by local optimizations as it involves multiphysics field design, which is also inefficient and time-consuming process. The artificial intelligence (AI) maybe is a potential method for the optimization design of the blanket. So, this paper aims to develop an intelligent optimization method based on an improved multi-objective NSGA-III algorithm and an adaptive BP neural network to solve these problems mentioned above. This method has been applied on optimizing the radial arrangement of a conceptual design of CFETR HCSB blanket. Finally, a series of optimal radial arrangements are obtained under the constraints that the temperature of each component of the blanket does not exceed the limit and the radial length remains unchanged, the efficiency of the blanket optimization design is significantly improved. This study will provide a clue and inspiration for the application of artificial intelligence technology in the optimization design of blanket.

Low-dose CT Image Denoising Using Classification Densely Connected Residual Network

  • Ming, Jun;Yi, Benshun;Zhang, Yungang;Li, Huixin
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.14 no.6
    • /
    • pp.2480-2496
    • /
    • 2020
  • Considering that high-dose X-ray radiation during CT scans may bring potential risks to patients, in the medical imaging industry there has been increasing emphasis on low-dose CT. Due to complex statistical characteristics of noise found in low-dose CT images, many traditional methods are difficult to preserve structural details effectively while suppressing noise and artifacts. Inspired by the deep learning techniques, we propose a densely connected residual network (DCRN) for low-dose CT image noise cancelation, which combines the ideas of dense connection with residual learning. On one hand, dense connection maximizes information flow between layers in the network, which is beneficial to maintain structural details when denoising images. On the other hand, residual learning paired with batch normalization would allow for decreased training speed and better noise reduction performance in images. The experiments are performed on the 100 CT images selected from a public medical dataset-TCIA(The Cancer Imaging Archive). Compared with the other three competitive denoising algorithms, both subjective visual effect and objective evaluation indexes which include PSNR, RMSE, MAE and SSIM show that the proposed network can improve LDCT images quality more effectively while maintaining a low computational cost. In the objective evaluation indexes, the highest PSNR 33.67, RMSE 5.659, MAE 1.965 and SSIM 0.9434 are achieved by the proposed method. Especially for RMSE, compare with the best performing algorithm in the comparison algorithms, the proposed network increases it by 7 percentage points.

The Prognostic Factors Affecting Survival in Muscle Invasive Bladder Cancer Treated with Radiotherapy (방사선치료를 받은 근 침윤성 방광암의 예후 인자)

  • Chung Woong-Ki;Oh Bong-Ryoul;Ahn Sung Ja;Nah Byung Sik;Kwon Dong-Deuk;Park Kwangsung;Ryu Soo-Bang;Park Yang-IL
    • Radiation Oncology Journal
    • /
    • v.20 no.2
    • /
    • pp.130-138
    • /
    • 2002
  • Purpose : This study analyzed the prognostic factors affecting the survival rate and evaluated the role of radiation therapy in muscle-invading bladder cancer. Materials and Methods : Twenty eight patients with bladder cancer who completed planned definitive radiotherapy in the Departments of Therapeutic Radiology and Urology, Chonnam National University Hospital between Jan. 1986 to Dec. 1998 were retrospectively analyzed. The reviews were peformed based on the patients' medical records. There were 21 males and 7 females in this study. The median of age was 72 years old ranging from 49 to 84 years. All patients were confirmed as having transitional cell carcinoma with histological grade 1 in one patient, grade 2 in 15, grade 3 in 9, and uninformed in 3. Radiation therapy was peformed using a linear accelerator with 6 or 10 MV X-rays. Radiation was delivered daily with a 1.8 or 2.0 Gy fraction size by 4 ports (anterior-posterior, both lateral, alternatively) or 3 ports (Anterior and both lateral). The median radiation dose delivered to the isocenter of the target volume was 61.24 Gy ranging from 59 to 66.6 Gy. The survival rate was calculated by the Kaplan-Meier method. Multivariate analysis was peformed on the prognostic factors affecting the survival rate. Results : The survival rate was $76\%,\;46\%,\;33\%,\;33\%$ at 1, 2, 3, 5 years, respectively, with 19 months of median survival. The potential factors of age (less than 70 years vs above 70), sex, diabetes mellitus, hypertension, hydronephrosis, 1-stage (T3a vs T3b), TUR, chemotherapy, total duration of radiotherapy, radiation dose (less than 60 Gy vs above 60 Gy), and the treatment response were investigated with uniand multivariate analysis. Un univariate analysis, the T-stage (p=0.078) and radiation dose (p=0.051) were marginally significant, and the treatment response (p=0.011) was a statistically significant factor on the survival rate. Multivariate analysis showed there were no significant prognostic factors affecting the survival rate. Conclusion : The treatment response and radiation dose are suggested as th은 statistically significant factors affecting the survival rate of muscle invasive bladder cancer. A Further prospective randomized study is needed to confirm these prognostic factors.

Evaluation of the heart and lung dosimetric parameters in deep inspiration breath hold using 3D Slicer

  • Eskandari, Azam;Nasseri, Shahrokh;Gholamhosseinian, Hamid;Hosseini, Sare;Farzaneh, Mohammad Javad Keikhai;Keramati, Alireza;Naji, Maryam;Rostami, Atefeh;Momennezhad, Mehdi
    • Radiation Oncology Journal
    • /
    • v.38 no.1
    • /
    • pp.68-76
    • /
    • 2020
  • Purpose: The present study was conducted to compare dosimetric parameters for the heart and left lung between free breathing (FB) and deep inspiration breath hold (DIBH) and determine the most important potential factors associated with increasing the lung dose for left-sided breast radiotherapy using image analysis with 3D Slicer software. Materials and Methods: Computed tomography-simulation scans in FB and DIBH were obtained from 17 patients with left-sided breast cancer. After contouring, three-dimensional conformal plans were generated for them. The prescribed dose was 50 Gy to the clinical target volume. In addition to the dosimetric parameters, the irradiated volumes and both displacement magnitudes and vectors for the heart and left lung were assessed using 3D Slicer software. Results: The average of the heart mean dose (Dmean) decreased from 5.97 to 3.83 Gy and V25 from 7.60% to 3.29% using DIBH (p < 0.001). Furthermore, the average of Dmean for the left lung was changed from 8.67 to 8.95 Gy (p = 0.389) and V20 from 14.84% to 15.44% (p = 0.387). Both of the absolute and relative irradiated heart volumes decreased from 42.12 to 15.82 mL and 8.16% to 3.17%, respectively (p < 0.001); however, these parameters for the left lung increased from 124.32 to 223.27 mL (p < 0.001) and 13.33% to 13.99% (p = 0.350). In addition, the average of heart and left lung displacement magnitudes were calculated at 7.32 and 20.91 mm, respectively. Conclusion: The DIBH is an effective technique in the reduction of the heart dose for tangentially treated left sided-breast cancer patients, without a detrimental effect on the left lung.

Modulation of Hyaluronic Acid Properties by Electron Beam Irradiation (전자선 조사를 이용한 히알루론산의 특성 조절)

  • Shin, Young Min;Kim, Woo-Jin;Kim, Yong-Soo;Jo, Sun-Young;Park, Jong-Seok;Gwon, Hui-Jeong;Lim, Youn-Mook;Nho, Young-Chang
    • Journal of Radiation Industry
    • /
    • v.5 no.2
    • /
    • pp.159-164
    • /
    • 2011
  • A variety of natural polymers have been used as tissue engineering scaffolds, drug delivery system, and cosmetic materials due to their higher biocompatibility and water uptake. As a major component of extracellular matrix, hyaluronic acid consisting of D-glucuronic acid and N-acetylglucosamine has been popularly used as a hydrogel material. Even though it has good properties to be used in the tissue engineering and cosmetic industry, its higher viscosity has limited a potential use in a variety of applications; only low content should be applied in preparing above products. In the present study, we investigated the effect of electron beam irradiation on the properties of hyaluronic acid. Hyaluronic acid paste containing low contents of water changed to solution after electron beam irradiation ranging from 1 to 10 kGy, which didn't exhibit any alteration of surface properties and morphological change after freeze-drying. However, its viscosity was significantly decreased as absorbed dose increased, which was approximately one by hundred in comparison with the viscosity of original hyaluronic acid solution with same concentration. In addition, it can still interact with positive charged chitosan generating polyelectrolyte complex. Therefore, only viscosity was decreased after electron beam irradiation, whereas other properties of hyaluronic acid maintained. Consequently, these hyaluronic acids with lower viscosities can be used in a variety of applications in tissue engineering, drug delivery, and cosmetic industry.

Characteristics of 23 MV Photon Beam from a Mevatron KD 8067 Dual Energy Linear Accelerator (Mevatron KD 8067 선형가속기의 23 MV 광자선의 특성)

  • Kim, Ok-Bae;Choi, Tae-Jin;Kim, Young-Hoon
    • Radiation Oncology Journal
    • /
    • v.8 no.1
    • /
    • pp.115-124
    • /
    • 1990
  • The characteristics of 23 MV photon beam have been presented with respect to clinical parameters of central axis depth dose, tissue-maxi mum ratios, scatter-maximum ratios, surface dose and scatter correction factors. The nominal accelerating potential was found to be $18.5\pm0.5$ MV on the central axis. The half-value layer (HVL) of this photon beam was measured with narrow beam geometry from central axis, and it has been showed the thickness of $24.5\;g/cm^2$. The tissue-maximum ratio values have been determined from measured percentage depth dose data. In our experimental dosimetry, the surface dose of maximum showed only $9.6\%$ of maximum dose at $10\times10\;cm^2$, 100 cm SSD, without blocking tray in. The TMR'S of $0\times0$ field size have been determined to get average $2.3\%$ uncertainties from three different methodis; are zero effective attenuation coefficient, non-ilnear least square fit of TMR's data and effective linear attenuation coefficient from the HVL of 23 MV photon beams of dual energy linear accelerator.

  • PDF