• Title/Summary/Keyword: posture axis

Search Result 112, Processing Time 0.031 seconds

Development of a Low-cost Unmanned Underwater Vehicle and Performance Verification (저가 수중 무인 이동체 개발 및 운동성능 검증)

  • Hwang, Dongwook;Jang, Mingyu;Kim, Jinhyun
    • The Journal of Korea Robotics Society
    • /
    • v.13 no.2
    • /
    • pp.103-112
    • /
    • 2018
  • In this paper, a high performance underwater vehicle which can be manufactured at low cost is designed and fabricated, and its performance is verified through experiments. To improve efficiency, the Myring equation is used to design the appearance and the duct structure including the thruster is planned to increase the propulsion efficiency while reducing the drag force. Through various methods, it is secured stable waterproof performance, and also is devised to have high speed movement and turning performance. The developed underwater vehicle is equipped with a high output BLDC motor to achieve a linear speed of up to 2 m/s and can change direction rapidly with stability through four rudders. The rudders are driven by coupling a timing belt and a pulley by extending the axis of a servo motor, and are equipped at the end of the body to turn heading. In addition, for stable posture control, the roll keeps its internal center of gravity low and maintains its stability due to restoring force. By controlling the four rudders, pitch and yaw are handled by the PID controller and show stable performance. To investigate the horizontal turning performance, it is confirmed that the yaw rate controller is designed and stable yaw rate control is performed.

Fuzzy Distance Estimation for a Fish Robot

  • Shin, Daejung;Na, Seung-You;Kim, Jin-Young
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.5 no.4
    • /
    • pp.316-321
    • /
    • 2005
  • We designed and implemented fish robots for various purposes such as autonomous navigation, maneuverability control, posture balancing and improvement of quick turns in a tank of 120 X 120 X 180cm size. Typically, fish robots have 30-50 X 15-25 X 10-20cm dimensions; length, width and height, respectively. It is essential to have the ability of quick and smooth turning to avoid collision with obstacles or walls of the water pool at a close distance. Infrared distance sensors are used to detect obstacles, magneto-resistive sensors are used to read direction information, and a two-axis accelerometer is mounted to compensate output of direction sensors. Because of the swing action of its head due to the tail fin movement, the outputs of an infrared distance sensor contain a huge amount of noise around true distances. With the information from accelerometers and e-compass, much improved distance data can be obtained by fuzzy logic based estimation. Successful swimming and smooth turns without collision demonstrated the effectiveness of the distance estimation.

$\Delta$-plan and spin in the golf swing (골프 스윙에서 $\Delta$-평면과 스핀)

  • Jo, Chang-Ho;Park, Jong-Dae;Lee, Kun-Chun
    • The Journal of Natural Sciences
    • /
    • v.14 no.2
    • /
    • pp.1-14
    • /
    • 2004
  • The observation of the various swing parameters and its effect on golfer swing are tatally analyzed. The golf ball impact and flies away, therefore it must be controlled bofore ball impact. The purpose of this paper is that the cause of hook and slice are found and the posture of swing is corrected. The trajectory after ball impact is on the $\Delta$-plane, which is consisted of the normal vector on club face and the swing velocity vector of club head including the initial celocity and the spin axis after ball imfact. In order to correct the miss shot in golf swing, this paper is is shown that the theoretical review and study is discussed to use the D-plane and $\Delta$-plane.

  • PDF

Design of Electric Wheelchair Using Triple Axis Acceleration Sensor (3축 가속도 센서를 이용한 전동휠체어 설계)

  • Son, Jin-su;Nam, Jea-dong;Kim, Jung-min;Hong, Tae-kyoung;Kwon, Eun-Shin;Nam, Jae-hyun;Park, Hee-jung;Lee, Ju-won
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.05a
    • /
    • pp.836-837
    • /
    • 2014
  • The electric wheelchair is the vehicle system to support the elderly, infirm, and disabled person. Most of the electric wheelchair is used the encoder sensor for controlling the posture, and the encoder generates the defects caused by frequent mechanical friction. To improve the problem, we have designed the electric wheelchair base on triple acceleration sensor, and implemented. And its performance was evaluated through experiments.

  • PDF

EVALUATION OF CONDYLAR POSITION USING COMPUTED TOMOGRAPH FOLLOWING BILATERAL SAGITTAL SPLIT RAMUS OSTEOTOMY (전산화단층촬영법을 이용한 하악 전돌증 환자의 하악지 시상 골절단술후 하악과두 위치변화 분석)

  • Chol, Kang-Young;Lee, Sang-Han
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.18 no.4
    • /
    • pp.570-593
    • /
    • 1996
  • This study was intended to perform the influence of condyle positional change after surgical correction of skeletal Class III malocclusion after BSSRO in 20 patients(males 9, females 11) using computed tomogram that were taken in centric occlusion before, immediate, and long term after surgery and lateral cephalogram that were taken in centric occlusion before, 7 days within the period intermaxillary fixation, 24hour after removing intermaxillary fixation and long term after surgery. 1. Mean intercondylar distance was $84.45{\pm}4.01mm$ and horizontal long axis of condylar angle was $11.89{\pm}5.19^{\circ}$on right, $11.65{\pm}2.09^{\circ}$on left side and condylar lateral poles were located about 12mm and medial poles about 7mm from reference line(AA') on the axial tomograph. Mean intercondylar distance was $84.43{\pm}3.96mm$ and vertical axis angle of condylar angle was $78.72{\pm}3.43^{\circ}$on right, $78.09{\pm}6.12^{\circ}$on left. 2. No statistical significance was found on the condylar change(T2C-T1C) but it had definitive increasing tendency. There was significant decreasing of the distance between both condylar pole and the AA'(p<0.05) during the long term(TLC-T2C). 3. On the lateral cephalogram, no statistical significance was found between immediate after surgery and 24 hours after the removing of intermaxillary fixation but only the lower incisor tip moved forward about 0.33mm(p<0.05). Considering individual relapse rate, mean relapse rate was 1.2% on L1, 5.0% on B, 2.0% on Pog, 9.1% on Gn, 10.3% on Me(p<0.05). 4. There was statistical significance on the influence of the mandibular set-back to the total mandibular relapse(p<0.05). 5. There was no statistical significance on the influence of the mandibular set-back(T2-T1) to the condylar change(T2C-T1C), the condylar change(T2C-T1C, TLC-T2C) to the mandibular total relapse, the pre-operative condylar position to the condylar change(T2C-T1C, TLC-T2C), the pre-operative mandibular posture to the condylar change(T2C-T1C, TLC-T2C)(p>0.05). 6. The result of multiple regression analysis on the influence of the pre-operative condylar position to the total mandibular relapse revealed that the more increasing of intercondylar distance and condylar vertical axis angle and decreasing of condyalr head long axis angle, the more increasing of mandibular horizontal relapse(L1,B,Pog,Gn,Me) on the right side condyle. The same result was founded in the case of horizontal relapse(L1,Me) on the left side condyle.(p<0.05). 7. The result of multiple regression analysis on the influence of the pre-operative condylar position to the pre-operative mandibular posture revealed that the more increasing of intercondylar distance and condylar vertical axis angle and decreasing of condylar head long axis angle, the more increasing of mandibular vertical length on the right side condyle. and increasing of vertical lengh & prognathism on the left side condyle(p<0.05). 8. The result of simple regression analysis on the influence of the pre-operative mandibular posture to the mandibular total relapse revealed that the more increasing of prognathism, the more increasing of mandibular total relapse in B and the more increasing of over-jet the more increasing of mandibular total relapse(p<0.05). Consequently, surgical mandibular repositioning was not significantly influenced to the change of condylar position with condylar reposition method.

  • PDF

Is the Agricultural Work a Risk Factor for Koreans Elderly Spinal Sagittal Imbalance?

  • Hong, Jong-Hwan;Han, Moon-Soo;Lee, Seul-Kee;Lee, Jung-Kil;Moon, Bong Ju
    • Journal of Korean Neurosurgical Society
    • /
    • v.63 no.5
    • /
    • pp.623-630
    • /
    • 2020
  • Objective : A primary degenerative sagittal imbalance has been considered because of unique lifestyles such as the prolonged crouched posture during agricultural work and performing activities of daily living on the floor. Previous papers have reported that sagittal imbalance disease is often seen distinctly in the farming districts of "oriental" countries such as Korea and Japan. However, this finding was only evaluated with the use of X-ray, and other factors such as magnetic resonance imaging (MRI), muscle volume, compression fracture, and laboratory results were not considered. Thus, using these, we evaluate the agricultural work-associated factors for Korean elderly spinal sagittal imbalance. Methods : We recruited 103 Korean participants who had a sagittal vertical axis (SVA) of >5 cm in this Korean Elderly Sagittal Imbalance Cohort Study. The following were evaluated : radiological parameters, MRI, compression fracture, vitamin D, parathyroid hormone, C-terminal telopeptide, osteocalcin, bone mineral density and muscle fatty change, muscle volume, and health-related quality of life from patients' survey. Moreover, in this survey, the farmers' annual working hours were investigated. Subsequently, we analyzed the associated factors for spinal sagittal imbalance depending on occupation. Results : A total of 46 participants were farmers, and the others were housewives, sellers, and office workers. The farmer group had more SVA (141 vs. 99 mm, p=0.001) and pelvic tilt (31° vs. 24°, p=0.004) and lesser lumbar lordosis (20° vs. 30°, p=0.009) and thoracic kyphosis (24° vs. 33°, p=0.03) than non-farmer group. A significantly positive correlation was noted between the working hour and SVA in the farmer group (p=0.014). The visual analogue scale score for back pain (8.26 vs. 6.96, p=0.008) and Oswestry Disability Index (23.5 vs. 19.1, p=0.003) in the farmer group were higher than that in the non-farmer group, but the Short Form-36 score was not significantly different between the two groups. The Mini-Mental State Exam score was significantly lower in the farmer group than in the non-farmer group (24.85 vs. 26.98, p=0.002). Conclusion : The farmer group had more sagittal imbalance and back pain in proportion to the working hours even though the muscle and bone factors and general laboratory condition were not significantly different between the two groups. These results supported that the long hours spent in the crouched posture while performing agricultural work were a risk factor for severe sagittal imbalance.

EFFECTS ON THE ENLARGEMENT RATIOS DUE TO CHANGES OF HEAD POSTURE ON LATERAL HEADFILMS (측두 규격방사선사진 촬영시 두부의 위치변화가 확대율에 미치는 영향)

  • Seo, Young-Hun;Choi, Yeong-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.1
    • /
    • pp.185-194
    • /
    • 2001
  • This study was designed to evaluate the effects of angulation changes of head posture on the enlargement ratios of a lateral headfilm depending on the vortical or horizontal rotation of the objects. A device was constructed to measure regional changes of enlargement ratios. The device was held within the cephalostat and cephalograms recorded at each measured degrees of the device tilting, vertically and horizontally. The enlargement ratios of the horizontal, vertical, and angular measurements on the films taken at each tilted angulations were obtained and compared with those on the films taken without rotation. In summary, the enlargement ratios of the horizontal linear measurements were decreased during horizontal rotations. The enlargement ratios of vortical measurements of the right side on the film were increased and those of the left side were decreased by the horizontal rotations. Enlargement ratios of horizontal measurements were affected further than those of vertical measurements by the same angular changes of the horizontal rotations. Therefore, a disruption of parallelism between the object's midsagittal plane and the film could result in distortion of the image while vertical rotation around the object's porionic axis would not significantly affect the enlargement ratios on the headfilm.

  • PDF

Development of the Balance Chair for Improving Postural Control Ability & Pelvic Correction (골반교정 및 자세균형능력 증진을 위한 균형의자 개발)

  • Oh, Seung-Yong;Shin, Sun-Hye;Kang, Seung-Rok;Hong, Chul-Un;Kwon, Tae-Kyu
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.11 no.3
    • /
    • pp.271-277
    • /
    • 2017
  • The purpose of this study was to develop a balance chair for improving pelvic correction and postural balance through postural balance training using tactile feedback by a vibration motor provided in real time according to the user's attitude. We built a body frame using mono cast(MC) Nylon, Touch thin film transistor(TFT) for user interface, a main control module using Arduino, a 9-axis acceleration sensor for user's posture determination, and a vibration module for tactile feedback. The prototype of the Balance Chair which surrounds the outside was made with cushion for sitting conformability. In order to verify the effectiveness of the postural balance training system using the built prototype, the muscle activity (% MVIC) of the left and right iliocostalis lumborum those are the main muscles of the spinal movement was measured with ten female subjects. And the balance ability before and after training was measured using Spine Balance 3D, a posture balance ability evaluation device. The muscular activities of the left and right iliocostalis lumborum showed the balance activation according to vibration feedback during exercise protocol and postural balance improved after balance exercise training using balance chair. This study could be apply to use the fundamental research for developing the various postural balance product.

Changes of Setup Variables by the Change of Golf Club Length (골프 클럽의 길이 변화에 따른 준비 자세의 변화)

  • Sung, Rak-Joon
    • Korean Journal of Applied Biomechanics
    • /
    • v.15 no.3
    • /
    • pp.95-104
    • /
    • 2005
  • To know the proper setup posture for the various clubs, changes of setup variables according to the change of golf club length was investigated. Swing motions of three male low handicappers including a professional were taken using two high-speed videocameras. Four clubs iron 7, iron 5, iron 3 and driver (wood 1) were selected for this experiment. Three dimensional motion analysis techniques were used to get the kinematical variables. Mathcad and Kwon3D motion analysis program were used to analyze the position, distance and angle data in three dimensions. The variables divided into three categories 1) position and width of anterior-posterior direction 2) position and width of lateral direction 3) angles and evaluated based on the theories of many good golf teachers. Major findings of this study were as follows. 1.The stance (distance between ankle joints) was increased as the length of the club increased but the increasing width was not large. It ranges from 5cm to 10cm and professional player showed small changes. 2. Forward lean angle of trunk was decreased (more erected) as the length of the club increased. It ranges from 30 degrees for iron7 to 25 degrees for driver. 3. Angle between horizontal and right shoulder were increased as the length of the club increased. It ranges from 10 degrees to 20 degrees and professional player showed small changes. 4. Anterior-posterior position of the shoulders were located in front of the foot for all clubs and the difference between the shoulder and knee position was decreased as the length of the club increased. 5. Anterior-posterior position of grip (hand) was located almost beneath the shoulders (2.5cm front) for iron7, but it increased to 10cm for the driver. This grip adjustment makes the height of the posture increased only 5cm from iron7 to driver. 6. Lateral position of grip located at 5cm left for the face of iron7, but it located at the right side (behind) for the face of driver. 7. Lateral position of the ball located at the 40%(15cm) of stance from left ankle for iron7 and located at the 10% (5cm) of stance for driver. 8. Head always located at the right side of the stance and the midpoint of the eyes located at the 37% of stance from the right ankle for all clubs. This means that the axis of swing always maintained consistently for all clubs. 9. Left foot opened to the target for all subject and clubs. The maximum open angle was 25 degrees. Overall result shows that the changes of the setup variables vary only small ranges from iron7 to driver. Paradoxically it could be concluded that the failure of swing result from the excessive changes of setup not from the incorrect changes. These findings will be useful for evaluating the setup motion of golf swing and helpful to most golfers.

The Influence of Home Position(H.P.) and Random Position(R.P.) on the Shape of Prepared Tooth Surfaces -Upper Left 1st Molar for Full Cast Crown- (시술자세가 치관 삭제면 형태에 미치는 영향 -상악 좌측 제 1 대구치의 전부 주조관-)

  • Lee, Seung-Jeong;Choi, Dae-Gyun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.17 no.4
    • /
    • pp.257-274
    • /
    • 2001
  • To properly prepare teeth, dentists require a direct view of the working area and are often placed in a difficult position, moreover, a high proportion of dentists suffer from headache and back pain. Dentists who make use of the dental mirror and position their patients carefully to gain a proper view report less headache, pain and discomfort in the shoulders. It is recommended that dentists learn the "Home Position(H.P.)" which among the various "Random Position(R.P.)" methods, enables dentists to approach their patients in a stable posture. The purpose of this study was to compare tooth preparation in the H.P. and the R.P., and evaluate the clinical efficacy of the H.P.. Tooth preparation for a full cast crown was performed on the maxillary left 1st molar using the H.P. and the R.P., and the shapes of the prepared tooth surfaces at the two different operating positions were compared. The amount of occlusal reduction, marginal width, height, and axial taper were measured and analyzed. A T-test was performed separately to compare the results of the H.P. and the R.P. with respect to the accuracy of the corresponding tooth reduction. The results were as follows. ; 1. The amount of occlusal reduction was excessive on the mesiobuccal cusp(P<0.05), and deficient on the lingual cusp in the H.P.(P<0.01). In the R.P., this was excessive on the buccal cusp and deficient on the fossa and distolingual cusp(P<0.01). 2. The amounts of marginal width were excessive in all areas except on the lingual and mesial surfaces in the H.P. and lingual surface in the R.P.(P<0.01). 3. The marginal heights were achieved more accurately in the R.P. than the H.P.(P<0.01). 4. Axial surface taper was excessive in all areas in the H.P.(P<0.01). But the axial taper of measured areas was even, and tooth is more like to retain its original axis after reduction. In the R.P., axial surface taper was excessive on the mesial and buccal area, and deficient on the distolingual area(P<0.01), and therefore, the axis of the prepared teeth was tipped in the distolingual direction. 5. The times needed for preparation were 12 minutes and 49 seconds in the H.P., and 11 minutes and 35 seconds in the R.P., and the R.P. was statistically faster(P<0.01). The tooth preparation in the H.P. achieved its goal, in that it enabled the operator to make even tooth reduction. In conclusion, the H.P. system offers an improved method that can be used in clinic after specific training.

  • PDF