• Title/Summary/Keyword: portable sensor system

Search Result 182, Processing Time 0.037 seconds

A Compound Sensor and a Portable System for the Measurement of Urea-and-Glucose Concentration in Blood (혈중요소-혈당농도 측정 복합센서 및 휴대용 시스템)

  • 유재택;이동하;민남기
    • Proceedings of the IEEK Conference
    • /
    • 2003.07c
    • /
    • pp.2871-2874
    • /
    • 2003
  • The development of a portable system to be used by diabetes patients and renal discase patients is needed to monitor their urea concentration and their glucose concentration in blood. This paper reports a compound sensor composed of a urea sensor, a glucose sensor and a micro-channel. This paper also reports the development of a portable measurement system to measure the concentrations, display the values, and save the values to be used by doctors.

  • PDF

Portable ECG Sensor Module and Monitoring System Implementation Considering Reduction of Powerline Noise and Baseline Wander (전원잡음과 기저선변동을 고려한 이동형 ECG 센서모듈 및 모니터링 시스템 구현)

  • Oh Do-Chang;Choi Dong-Hyuk;Lee Hong-Woo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.12 no.10
    • /
    • pp.1022-1028
    • /
    • 2006
  • A portable ECG sensor module and monitoring system which has the powerline noise reduction and the baseline wander removal is proposed. A small-szie ECG sensor H/W module with the 8-bits microprocessor is implemented. The ECG waveform can be inspected anytime with PDA in real time, and transmitted to the PC through wireless LAN. Portable ECG system can offer the environment that give the lasting medical service to the elderly and the long-time hospitalized patients at the wanted place, and the system can be attached to the chair, wheel chair, treadmill, elderly walker and used to monitor the health condition of man

Implantation of portable hydrogen alarm system based on palladium coated single mode optical fiber sensor (팔라듐이 코팅된 단일모드 광섬유 센서를 이용한 수소 경보 시스템 구현)

  • Mun, Nam-Il;Yang, Byung-Cheol;Kim, Kwang-Taek;Kim, Tae-Un
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.269-273
    • /
    • 2009
  • In this paper, a study on a portable hydrogen alarm system based on the palladium coated single mode fiber sensor has been reported. The fabricated hydrogen sensor exhibited 0.14 dB, 0.41 dB and 0.54 dB optical intensity variation when it was exposed by the nitrogen and hydrogen mixed gas containing 0.5 %, 1 % and 4 % of the hydrogen concentration, respectively. The fabricated sensor exhibited 20 second of response time and 120 second of recovery time for 4 % hydrogen containing gas. The fiber optics layout and software algorithm for detection of hydrogen leakage have been presented. The implanted portable hydrogen alarm system successfully generated an alarm signal when a 4 % hydrogen containing gas was leaked out.

Signal lock-in detection circuit for mobile device sensor systems (이동 통신 단말용 센서 시스템을 위한 신호 잠금 방식의 검출 회로)

  • Jung, In-Il;Son, Ho-Hyun;Choi, Young-Wan
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2008.08a
    • /
    • pp.559-562
    • /
    • 2008
  • In this paper we propose a lock-in detection method for portable sensor systems and demonstrate with the portable detection module that has high sensitivity and robustness against the noise. The simple portable sensor module is manufactured using MCU(Micro Contorl Unit), OPAMP, MOSFET and a pair of infrared sensor. Manufactured sensor module is testified in the noisy environment caused by an external light and an white noise source. Without any type of band pass filters, we recover a signal of 33 $mV_{p-p}$ in 80 $mV_{p-p}$ white noise and get the DR(Dynamic Reserve) of 14 dB.

  • PDF

Design and performance evaluation of portable electronic nose systems for freshness evaluation of meats (육류 신선도 판별을 위한 휴대용 전자코 시스템 설계 및 성능 평가)

  • Kim, Jae-Gone;Cho, Byoung-Kwan
    • Korean Journal of Agricultural Science
    • /
    • v.38 no.3
    • /
    • pp.525-532
    • /
    • 2011
  • The aim of this study was to develop a portable electronic nose system for freshness measurement of meats, which could be an alterative of subjective measurements of human nose and time-consuming measurements of conventional gas chromatograph methods. The portable electronic system was o optimized by comparing the measurement sensitivity and hardware efficiency, such as power consumption and dimension reduction throughout two stages of the prototypes. The electronic nose systems were constructed using an array of four different metal oxide semiconductor sensors. Two different configurations of sensor array with dimension were designed and compared the performance respectively. The final prototype of the system showed much improved performance on saving power consumption and dimension reduction without decrease of measurement sensitivity of pork freshness. The results show the potential of constructing a portable electronic system for the measurement of meat quality with high sensitivity and energy efficiency.

Development of a Portable Potentiostat with Wireless Communications for Measuring Dissolved Oxygen (용존산소 측정을 위한 무선통신 기반 휴대형 포텐쇼스탯 개발)

  • Lee, Hyun-Seok;Han, Ji-Hoon;Pak, Jungho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.12
    • /
    • pp.1641-1647
    • /
    • 2018
  • In this paper, we describe a portable potentiostat which is capable of cyclic voltammetry(CV) and amperometry for electrochemical dissolved oxygen sensor. In addition, this portable potentiostat can also transmit the measured data wirelessly to android devices such as smart phone, tablet, etc. through Bluetooth. The potentiostat system consists of three parts; a voltage generator circuit which is controlled by Arduino nano and 12-bit DAC(digital to analog converter) to generate necessary electric potential for operating the electrochemical sensor, an oxidation/reduction current measurement circuit, and a Bluetooth module to transmit data wirelessly to an android device. Once measurements are carried out with the android application, the measured data is transmitted to the android device via Bluetooth and displayed using the android app. in real time. In this paper, we report the measured reduction current with a fabricated dissolved oxygen sensor in both saturated-oxygen state and zero-oxygen states. The results of the developed portable potentiostat system are in good agreement with those of the commercial portable potentiostat (${\mu}stat200$, Dropsens inc.). The measured peak reduction currents using the developed potentiostat and the commercial ${\mu}stat200$ potentiostat were $-0.755{\mu}A$ and $-0.724{\mu}A$, respectively. The reduction currents measured at zero-oxygen state were $-0.005{\mu}A$ and $-0.004{\mu}A$. The discrepancy between those two systems seems very small, which implies successful development of a portable and wireless potentionstat.

A Study of an Implementable Sun Tracking Algorithm for Portable Systems

  • Choi, Ju-Yeop;Choy, Ick;Song, Seung-Ho;An, Jinung;Lee, Dong-Ha;Kim, Jung-Won
    • Journal of Power Electronics
    • /
    • v.13 no.6
    • /
    • pp.1051-1057
    • /
    • 2013
  • This paper proposes an implementable sun tracking algorithm for portable systems powered by alternative energy sources. The proposed system uses a 2-axis tilt sensor and a 3-axis magnetic sensor to measure the orientation and posture of the system, according to a horizon coordinates system, and compensate for tilt effects. Then, through an astronomical calculation, using the present time and position information obtained from GPS sensors, the azimuth and altitude of the sun in that location is calculated and converted to portable sun tracking system coordinates and used to control the A- and C-axes of the system.

Development of Portable u-Health Monitoring System (휴대형 u-Health 모니터링 시스템 개발)

  • Han, Jung-Soo;Kim, Gui-Jung
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.11
    • /
    • pp.46-53
    • /
    • 2009
  • This study aims to develop a mobile-based portable u-Health Monitoring System which provides a personal medical service on demand by processing patients' data intellectually achieved through sensing technique of non-restriction/non-consciousness oriented and deciding. To do this, we composed a USN-based portable monitoring unit. It is the one, that contains a somatometry sensor which is attached to patient's body and detects bio information, a portable wireless terminal which receives information from the sensor and transmits it to monitor server, and a monitor server which interprets received data through wireless network and processes. Also, it tries to develop a non-restriction /non-consciousness oriented sensing technique which is related to glycosuria and cardiovascular diseases.

Development of Portable System for Measuring pH in Blood (휴대용 혈중pH 측정시스템의 구현)

  • 정도운;김우열;배진우;강성철;심윤보;전계록
    • Proceedings of the IEEK Conference
    • /
    • 2001.06e
    • /
    • pp.195-198
    • /
    • 2001
  • We developed the portable blood analysis system, which can be measured pH of the blood. This system is composed to electronic circuit, mechanism, and system software. Electronic circuit is composed to the sensor, pre-amp part, temperature regulation part, fluid sensing part, A/D(analog to digital) conversion part, main and peripheral device processing part. And the mechanism is composed to the flow cell and the liquid flow part. The liquid flow part is consisted of blood and washing control system under the control of the 6-channel solenoid valve and syringe rump. The system software is composed to measurement program, calibration program, washing and diagnostic program. The program of each routine is designed as sequential process for an efficiency. And the portable pH analysis system used two-point calibration method using the two types of corrective liquid. As a result, we obtained the calibration curve and calculated the value of pH. For verifying the system, we confirmed the output voltage of the sensor, and estimated reappearance of system using the standard liquid.

  • PDF

Economical Gas Chamber for In-situ Gas Measurement and Analysis of Gas Response Characteristics according to Sensor Voltage (인시투 가스 측정이 가능한 경제적 가스 챔버 구현 및 센서 전압에 따른 가스 응답 특성 분석)

  • Choi, Yun-Suk;Lee, In Hwan
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.5
    • /
    • pp.1-8
    • /
    • 2019
  • Breath analysis using a portable device is better than the classical breath analysis system in terms of installation and operation. There is an increasing need to develop cost-effective equipment for testing gas sensors from the viewpoint of functionalities that can be applied applicable to portable devices. In the present study, an economical gas chamber for in-situ gas measurement is implemented with a single gas chamber without using expensive gas storage and control equipment; the gas response characteristics are analyzed using the above-described chamber. The main features of the implemented gas chamber are simple injection procedure, improved gas diffusion, easy measurement and cleaning, support for low-power mode measurement function for portable devices, and open source platform. Moreover, an analysis of gas response characteristics based on changes in sensor voltage show that the sensitivity and 90% response time are affected by the sensor voltage. Furthermore, the sensitivity graph has an inflection point in a specific range. The gas sensor applied in this study showed fast response speed and high sensitivity for sensor voltages of 3.0-3.5 V, regardless of the concentration of acetone gas, the target gas used in this study.