• Title/Summary/Keyword: polyvinylidene fluoride (PVDF)

Search Result 211, Processing Time 0.028 seconds

Realtime Detection of Damage in Composite Structures by Using PVDE Sensor (압전고분자 센서를 이용한 복합재 구조의 실시간 손상탐지)

  • ;Y. A. Dzenis
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2002.10a
    • /
    • pp.118-121
    • /
    • 2002
  • Polyvinylidene di-fluoride (PVDF) film sensor appeared to be practically useful for the structural health monitoring of composite materials and structures. PVDF film sensors were either attached to or embedded in the graphite/epoxy composite (CFRP) samples to detect the fatigue damage at the bondline of single-lap joints or the tensile failure of unidirectional laminates. PVDF sensors were sensitive enough to detect and determine the crack front in linear location since composites usually produce very energetic acoustic emission (AE). PVDF sensors are extremely cost-effective, as flexible as other plastic films, in low profile as thin as a few tens of microns, and have relatively wide-band response, all of which characteristics are readily utilized for the structural health monitoring of composite structures. Signals due to fatigue damage showed a characteristics of mode II (shear) type failure whereas those from fiber breakage at DEN notches showed that of mode I (tensile) type fracture.

  • PDF

Low-Velocity Impact Damage Detection for Gr/Ep Laminates Using PVDF Sensor Signals (PVDF 센서신호를 이용한 Gr/Ep 적층판의 저속충격 손상탐지)

  • 박찬익;김인걸;이영신
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2003.10a
    • /
    • pp.158-162
    • /
    • 2003
  • The PVDF(polyvinylidene fluoride) film sensor as one of smart sensors has good characteristics to detect the impact damages of composite structures. The capabilities of the PVDF film sensor for evaluating impact behaviors and damages of Gr/Ep laminates subjected to low-velocity impact were examined. From sensor signals, the specific wave-forms implying the damage were detected. The wavelet transform(WT) and Short Time Fourier Transform(STFT) were used to decompose the piezoelectric sensor signals in this study. The impact behaviors of Gr/Ep laminates were simulated and the impact forces were reconstructed using the sensor signals. Finally, the impact damages were predicted by finite element analysis with the reconstructed forces. For experimental verification, a series of low-velocity impact tests from low energy to damage-induced energy were carried-out. The extent of damage in each case was examined by means of ultrasonic C-scan and the measured damage areas were agreed well with the predicted areas by the F.E.A.

  • PDF

PVDF Dynamic Tactile Event Sensor for Ubiquitous Computing

  • Kim, Tae-Hee;Park, Mi-Keung
    • Journal of Korea Multimedia Society
    • /
    • v.7 no.6
    • /
    • pp.767-780
    • /
    • 2004
  • Interaction requires dynamic relationship between objects. In ubiquitous computing environment, interaction between human and the environment is implied. Tactile interaction has so far been less addressed, while tactile sensation should be an important topic in the field of multimedia study. This paper describes development of a novel PVDF (Polyvinylidene Fluoride) dynamic tactile sensor and associated experiments. PVDF dynamic tactile sensors detect touch events applied to the sensor skin by low frequency components of the signal. Rubber skin-covered sensing material was mounted on the bones. Robust performance with low noise was figured out in our robotic experiment. Whereas most conventional sensors are interested in measurement, our dynamic tactile sensor is sensitive to change of state, which could be a key for economic understanding of happenings in the dynamic world. We note that dynamic sensing uses motion as a part of sensing modality We suggest that dynamic sensing be understood in technological terms in the perspective of interactive media and ubiquitous computing.

  • PDF

Synthesis of Poly(vinylidene fluoride-co-hexafluoropropylene) (비닐리덴 플루오라이드와 헥사플루오르프로필렌 공중합체의 합성)

  • Lee, Sang Goo;Ha, Jong-Wook;Park, In Jun;Lee, Soo-Bok;Lee, Jong Dae
    • Polymer(Korea)
    • /
    • v.37 no.1
    • /
    • pp.74-79
    • /
    • 2013
  • Polyvinylidene fluoride (PVDF) and its copolymer with hexafluoropropylene (HFP) were successfully prepared from free radical solution polymerizations using diisopropyl peroxidicarbonate (DIPPDC) in the presence of 1,1,2-trichlorotrifluoroethane (R-113). The reactivity ratios of VDF and HFP were estimated as$r_{VDF}=2.06{\pm}0.03$ and $r_{HFP}{\approx}0$. This result indicates that HFP cannot undergo self propagation. The weight-average molecular weight and molecular weight distribution of copolymers were found to decrease with increasing HFP content. The melting temperature of copolymers linearly decreased with the increase of HFP content because of the introduction of HFP. Moreover, no melting peak was observed for the copolymers with high HFP content. The glass transition temperature of copolymers gradually increased with the increase of HFP content due to the restricted flexibility of the polymer chains.

A study on the controlling degree of crystallinity by controlling substrate temperature (기판온도 제어에 의한 PVDF 박막의 결정화도 제어에 관한 연구)

  • Lee, Sun-Woo;Park, Su-Hong;Chung, Mu-Young;Lim, Eung-Choon;Park, Gu-Bum;Kim, Jin-Soo;Lee, Duck-Chool
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1792-1794
    • /
    • 1999
  • PVDF(Polyvinylidene Fluoride) thin films were prepared by using a physical vapor deposition system. Thin films were studied by X-ray diffraction (XRD), differential scanning calorimeter (DSC). The melting point$(T_m)$ of PVDF thin films increases with increasing substrate temperature. It is found that the degree of crystallinity of PVDF thin films increases from 49.8 to 67% with increasing substrate temperature from 30 to $80^{\circ}C$.

  • PDF

Effects of P(MMA-co-MAA) Compatibilizer on Morphological and Mechanical Properties of Nylon 6/PVDF Blend (P(MMA-co-MAA) 상용화제가 Nylon 6/PVDF 블렌드의 모폴로지 및 기계적 성질에 미치는 영향)

  • 김갑진;조항원;윤기종
    • Proceedings of the Korean Fiber Society Conference
    • /
    • 2002.04a
    • /
    • pp.481-484
    • /
    • 2002
  • nylon 6의 단점인 저온에서의 연성 및 내충격성 저하를 개선하는 동시에 nylon 6의 내후성도 개선시키는 방법의 하나로 유리전이온도가 매우 낮고, 내가수분해성, 내후성 및 연성(ductile property)이 뛰어난 불소함유 고분자계의 한 종류인 PVDF (polyvinylidene fluoride)를 nylon 6에 용융블렌드 하는 방법이 제안되었다. [1-5] 그런데 용융상태에서 두 고분자는 부분 혼화성만을 보이고, nylon 6과 PVDF는 모두 결정성 고분자이기 때문에 성형 후 냉각하는 동안 두 고분자의 결정화에 기인한 결정화유도 상분리가 일어나게 된다. (중략)

  • PDF

Enhanced Capability of Drain in Soft Clays from PVDF Film (PVDF 필름을 이용한 연약점토지반의 배수능력의 향상)

  • Park, Ji-Ho;Lee, Sung-Jin;Jun, Young-Woo;Kim, Young-Uk
    • Proceedings of the KAIS Fall Conference
    • /
    • 2010.11a
    • /
    • pp.451-453
    • /
    • 2010
  • PVDF(polyvinylidene fluoride) 필름은 압전특성을 가지며 음파에너지를 발생시키는 유연성 고분자필름이다. 이 연구에서는 기존 원통형 연직 배수재에 PVDF 필름의 음파에너지를 적용하여 점토의 미세입자가 배수재의 성능을 저하시키는 막힘현상(clogging)을 방지함으로써 배수재의 성능을 향상시키고, 압밀을 촉진시키고자 하였다.

  • PDF

PVDF interdigitated transducer for generating and detecting Lamb waves in plates

  • Gu, Hua;Lloyd, George M.;Wang, Ming L.
    • Smart Structures and Systems
    • /
    • v.4 no.3
    • /
    • pp.291-304
    • /
    • 2008
  • Piezoelectric materials have been widely used in ultrasonic nondestructive testing (NDT). PZT ceramics can be used to receive and generate surface acoustic waves. It is a common application to attach PZT transducers to the surface of structures for detecting cracks in nondestructive testing. However, not until recently have piezoelectric polymers attracted more and more attention to be the material for interdigitated (IDT) surface and guided-wave transducers. In this paper, an interdigitated gold-on-polyvinylidene fluoride (PVDF) transducer for actuating and sensing Lamb waves has been introduced. A specific etching technology is employed for making the surface electrodes into a certain finger pattern, the spacings of which yield different single mode responses of Lamb waves. Experiments have been performed on steel and carbon fiber composite plates. Results from PVDF IDT sensors have been compared with those from PZT transducers for verification.

Performance of PEG on immobilization of zero valent metallic particles on PVDF membrane for nitrate removal

  • Chan, Yi Shee;Chan, Mieow Kee;Ngien, Su Kong;Chew, Sho Yin;Teng, Yong Kang
    • Membrane and Water Treatment
    • /
    • v.9 no.1
    • /
    • pp.1-7
    • /
    • 2018
  • The principal objective of this study is to investigate the effect of Polyethylene Glycol (PEG) crosslinking in Polyvinylidene Fluoride (PVDF) in immobilization of Fe and bimetallic Fe/Cu and Cu/Fe zero valent particles on the membrane and its efficiency on removal of nitrate in wastewater. PVDF/PEG polymer solution of three weight compositions was prepared to manipulate the viscosity of the polymer. PEG crosslinking was indirectly controlled by the viscosity of the polymer solution. In this study, PEG was used as a modifier of PVDF membrane as well as a cross-linker for the immobilization of the zero valent particles. The result demonstrates improvement in immobilization of metallic particles with the increase in crosslinking of PEG. Nitrate removal efficiency increases too.

Signal-Characteristic Analysis with Respect to Backing Material of PVDF-Based High-Frequency Ultrasound for Photoacoustic Microscopy (광음향 현미경을 위한 PVDF 기반 고주파수 초음파 변환기의 흡음층 소재에 따른 신호 특성 분석)

  • Lee, Junsu;Chang, Jin Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.2
    • /
    • pp.112-119
    • /
    • 2015
  • Photoacoustic microscopy is capable of providing high-resolution molecular images, and its spatial resolution is typically determined by ultrasonic transducers used to receive the photoacoustic signals. Therefore, ultrasonic transducers for photoacoustic microscopy (PAM) should have a high operating frequency, broad bandwidth, and high signal-reception efficiency. Polyvinylidene fluoride (PVDF) is a suitable material. To take full advantage of this material, the selection of the backing material is crucial, as it influences the center frequency and bandwidth of the transducer. Therefore, we experimentally determined the most suitable backing material among EPO-TEK 301, E-Solder 3022, and RTV. For this, three PVDF high-frequency single-element transducers were fabricated with each backing material. The center frequency and -6 dB bandwidth of each transducer were ascertained by a pulse-echo test. The spatial resolution of each transducer was examined using wire-target images. The experimental results indicated that EPO-TEK 301 is the most suitable backing material for a PAM transducer. This material provides the highest signal magnitude and a reasonable bandwidth because a large portion of the energy propagates toward the front medium, and the PVDF resonates in the half-wave mode.