• Title/Summary/Keyword: polyvinyl chloride (PVC)

Search Result 165, Processing Time 0.029 seconds

Improvement of the electrochemical properties of low temperature synthesized carbon for anode materials in lithium-ion batteries (리튬이온전지의 음극 재료로서 저온합성탄소의 전기화학적 특성의 향상)

  • 이헌영;장석원;신건철;이성만;이종기;이승주;백홍구
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.10 no.1
    • /
    • pp.55-61
    • /
    • 2000
  • The electrochemical properties of hard carbon anodes in lithium ion batteries were improved by carbon coating using polyvinyl chloride (PVC). The reduction in irreversible capacity occured and the reversible capacity increased. It is suggested that the PVC carbon coating modifies the surface of hard carbon and reduces the surface reaction with species from air. The degree of the graphitization of PVC carbon was controlled by an addition of Ni, and the effect of the amount of Ni addition on the electrochemical properties was discussed.

  • PDF

A study on the Corona Electrification Phenomena for Polyvinyl chloride (PVC) (폴리염화비닐(PVC)의 코로나 대전현상에 관한 연구)

  • 박구범;황명환;조기선;이덕출;임헌찬
    • Journal of the Korean Society of Safety
    • /
    • v.7 no.2
    • /
    • pp.57-62
    • /
    • 1992
  • In this thesis, the electrification phenomenon was studied by measurement of charging current and discharging current in polymers when the carriers generated by corona discharge were supplied to the surface of polymers. Corona charging current of PVC, polar and noncrystalline polymer, was larger than that of nonpolar and amorphous polymers. Corona charging current on the specimen of naked upper surface (CIM) was larger than charging current on the specimen of electrode made. Carrier injection differed from interfacial phase of polymer surFace. The transfer phenomenon vaned with chemical structure of polymer and then the polar effect of PVC was remarkable because of large electron affinity of Cl. In the characteristics of discharging current of PVC, the abnormal current was observed. It was supposed that this phenomena presented the trap of injected carriers in PVC and that static electricity phenomenon was generated by trap.

  • PDF

A method for quantitative analysis of DEHP in PVC packing material by Near-Infrared Spectroscopy (근적외선 분광광도법을 이용한 PVC포장재 중 DEHP 정량법에 관한연구)

  • 김재관;윤미혜;박포현;김기철
    • Journal of environmental and Sanitary engineering
    • /
    • v.17 no.4
    • /
    • pp.61-67
    • /
    • 2002
  • NIRS(Near infrared spectroscopy) scanning from 1300nm to 2400nm was appl ied for the DEHP(di-(2 ethylhexyl)phthalate) in PVC(polyvinyl chloride_packing material. All samples were devided into calibration group and validation group. As a result of conduction the multiple regression analysis on the correlation between the NIR spectrum data and chemical assay value obtained by the Korea Food Sanitation Act. The validation model for measuring the DEHP content had R of 0.997, SEC of 0.132, SEP of 0.176 by MLR and R of 0.996, SEC of 0.142, SEP of 0.198 by PLS and the detection limit was 0.1%. The obtained results indicate that the NIR procedure can potentially be used as a nondestructive analysis method for the purpose of rapid and simple measurement of DEHP in PVC packing material.

The Combustion Gases Toxicity Evaluation of Plastics Material by Colorimetric Gas Detector Tubes (가스검지관법에 의한 플라스틱재료의 연소가스 독성평가)

  • 박영근;김동일;현성호
    • Fire Science and Engineering
    • /
    • v.16 no.4
    • /
    • pp.77-84
    • /
    • 2002
  • In this paper, we had analyzed comsbustion gases using a GASTEC colorimetric gas detector tube according to the method of NES 713 in order to combustion gases toxicity evaluation for beads polystyrene foam, extruded polystyrene foam, rigid polyurethane foam, flexible polyurethane foam, flexible polyvinyl chloride pipe, vinyl floor cover, polyethyelene foam(flame retardant untreated) and polyethyelene foam (flame retardant treated) of plastics material. As results of gas analyses by using this method, comsbustion gases producted from small specimens of plastics material had reached fatal to man at 30 minutes exposure time that had possesed toxicity index of more than 1. Toxicity indexes of each specimen were estimated range of 4.3∼179.2, flexible polyvinyl chloride showed the hightest toxicity index at 179.2, and beads polystyrene foams showed the lowest toxicity index at 4.3.

Studies on the Analysis of DOA in PVC Wrap Film and its Migration into Foodstuffs (염화비닐 랩 필름의 DOA 분석 및 식품에의 이행에 관한 연구)

  • Lee, Keun-Taik;Gyoung, Young-Soo;Park, Tae-Kyu
    • Korean Journal of Food Science and Technology
    • /
    • v.22 no.2
    • /
    • pp.145-149
    • /
    • 1990
  • Extraction and analysis conditions of di-(2-ethylhexyl) adipate (DOA) and its migration contents into foods wrapped with plasticized polyvinyl chloride (PVC) film during storage and cooking with microwave were examined using gas chromatography. Experiments on the extraction solvent and method showed that the method of reflux using carbon tetrachloride for longer than one hour allowed the highest extraction of DOA. Analysis of four PVC wrap films from different factories in domestic market showed the DOA contents of 18.9% for home-use and 24.6% for retail-use on the average. The highest migration during storage was observed in pork belly, which were 21% and 26% after one and three days respectively. During microwave cooking; smaller than 5.5% of DOA were migrated into foods when the film was not contacted with foods, whereas about 49% migration was observed in pork belly contacted with film directly.

  • PDF

Morphology and Mechanical Properties of Waste PVC Blends (I) -Morphology and Mechanical Properties of Waste PVC/PE Blends (폐 PVC계 고분자 블렌드의 구조 및 물성 연구(I) -폐 PVC/PE고분자 블렌드의 모폴로지 및 물성)

  • 박재찬;원종찬;최길영;이재흥;조성만;김명기
    • Polymer(Korea)
    • /
    • v.26 no.1
    • /
    • pp.37-44
    • /
    • 2002
  • The polymer blends of waste polyvinyl chloride (RPVC) and waste polyethylene(RPE) were prepared by melt mixing, and their morphology and tensile properties were evaluated after the copolymers having an ethylene group in backbone and ester group in side position were added as comptatibilizers. The blend compositions were varied as follows ; RPVC/RPE 85/15 wt%, where RPVC formed a continuous phase : 50/50, mid composition : 15/85, RPE a continuous phase. The blends revealed a very low compatibility between component polymers because they showed domain sizes greater than $10\mu\textrm{m}$ over all compositions, especially the worst compatibility around mid composition. The blends showed higher compatibility when ethylene vinylacetate copolymer(EVA) and ethylene ethylacrylate-graft-methyl methacrylate copolymers(EEA-MMA) were added.

Recovery of Rare Earth Elements from Nd Magnet Scrap Using PVC (PVC에 의한 네오디뮴 자석 스크랩으로부터 희토류 회수)

  • Lee, So-Yeong;Park, Sung-Hun;Son, Injoon;Sohn, Ho-Sang
    • Resources Recycling
    • /
    • v.27 no.1
    • /
    • pp.38-44
    • /
    • 2018
  • A large amount of Nd-Fe-B magnet scraps are generated during magnet manufacture process. In this study, selective chlorination of the rare earth elements by hydrogen chloride gas which obtained from the pyrolysis of polyvinyl chloride (PVC) was investigated. In thermogravimetric analysis, drastic weight loss was occurred at about 500 K and 710 K. At the isothermal experiments, the weight loss reaches about 30% above 673 K. XRD patterns characterized that after each experiments, ${\alpha}$-Fe, Nd oxychloride, Nd chloride, and Fe chlorides were formed, and the leaching residues remain only ${\alpha}$-Fe. The yields of Nd, Dy, and Fe for the isothermal experiment were increased with temperature and peaked at 873 K. As PVC ratio increased, the yields of Nd, Dy and Fe were also increased.

Evaluation of the Shielding Effect of Polyvinyl Chloride (PVC) on Low-dose Blending Radiation Energy (폴리 염화 비닐(PVC)의 저선량 융합 방사선에너지에 대한 차폐 효과 평가)

  • Kim, Seon-Chil;Cho, Sung-Hyoun
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.12
    • /
    • pp.129-134
    • /
    • 2019
  • PVC was chosen as a plastic product that can cope with lead, a radiation shielding material that is widely used in medical institutions. In addition to radiation shielding clothing, we want to evaluate whether it can be used as a medical device component and industrial shielding material in low dose areas. Commercial PVC has a density of 3.68 g/㎠ and can be positively expected sufficient shielding effect in certain radiation areas such as material flexibility and economy efficiency, and can be transformed into various forms and used as a lightweight shielding wall. The shielding performance was tested by adjusting the thickness of 5 sheets of 3mm PVC in the range of medical radiation used for clinical examination in medical institutions. Shielding performance against effective energy was evaluated based on tube radiation voltage of medical radiation. The thicker the PVC, the lower the tube voltage and the lower the effective energy, the greater the shielding effect. The shielding effect was 70% at 12mm thickness and 80kVp tube voltage. Therefore, the shielding effect of PVC material has a high dependence of thickness. In the future, continuous research is needed to make thin and light eco-friendly products while improving shielding performance.

A Study on the Control and Exposure Assessment to Vinyl Chloride in the Factory Processing and Producing PVC Resin (일부 PVC 수지 제조 및 가공 근로자의 염화비닐 폭로 평가와 대책에 관한 조사 연구)

  • Park, D.W.;Shin, Y.C.;Lee, N.R.;Lee, K.Y.;Oh, S.M.;Chung, H.K.
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.4 no.1
    • /
    • pp.33-42
    • /
    • 1994
  • This study was carried out to assess worker exposure to vinyl chloride monomer (VCM) and to present control measures in the factories processing and producing polyvinyl chloride (PVC) resin. The conclusion remarks are as follows. Only two personal samples in the factory ("E") processing polyvinyl chloride resin were analysed to be 27.6 ppm and 12.6 ppm, respectively. But, these concentration exceed 1 ppm, Permissible Exposure Limits (PEL) of OSHA. So, worker's exposure to VCM at "E" factory should be reevaluated. In "A", "B" and "C" factory producing polyvinyl chloride resin, the average worker's exposures to VCM were 0.12 ppm, 0.86 ppm and 1.23 ppm, respectivery. Worker exposure to VCM at distillation and dry process was higer than other processes at "A" factory. The average exposure concentration of worker at polymerization process of "B" and "C" factory was 1.23 ppm, and 1.46 ppm respcetively. These concentration exceed 1 ppm, Permissible Exposure Limits of OSHA. Control room of "B" and "C" factory had 0.91 ppm and 0.65 ppm of worker's exposure concentration respectively. "A" factory was evaluated to be "acceptable", but "B" and "C" factories were evaluated to be "not acceptable", by the workplace exposure assessment program of AIHA. Process other than bagging and control room of "A" factory was evaluated to "not acceptable". Immediate correction measures for preventing workers from exposure to VCM should be performed in the factories or process that were evaluated to be "not acceptable". After these control measures are taken, worker exposure to VCM must be reevaluated through personal air monitoring. Control measures presented by this study are complete sealing of connecting pipe lines, flanging, packing, bolting and nutting. Periodic leak test for leak parts is also required. And positive pressure facility should be constructed at control room of "B" and "C" factory. Fresh air through cleaner such as HEPA filter should be supplied to control room. In addition to these control measures, periodic personal monitoring for evaluating worker exposure to VCM should be performed.

  • PDF