• 제목/요약/키워드: polystyrene particle

검색결과 134건 처리시간 0.054초

Negative Dielectrophoresis를 이용한 미세 입자의 유전율 측정 (Estimation of Dielectric Constant of Small Particles Using Negative Dielectrophoresis)

  • 이상욱;김용욱;김용권
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 추계학술대회 논문집 학회본부
    • /
    • pp.422-424
    • /
    • 1996
  • The dielectric constants of small particles are estimated using negative dielectrophoresis(DEP). A pair of cylindrical electrodes is proposed to produce a non-uniform electric field that levitates a dielectric particle. Measuring the height of the levitated particle, we can calculate the effective polarizability, and estimate the dielectric constant of the particle using a nonlinear regression method. By determining dielectric constant of polystyrene and polychloromethylstyrene particle, the proposed electrode structure and method show the possibility to measure the dielectric constants of dielectric particles.

  • PDF

두 평면 전극 사이의 절연체 구조물에 의해 유도되는 양의 유전영동을 이용한 삼차원 입자 정렬기 (A Three-Dimensional Particle Focusing Channel Using the Positive Dielectrophoresis (pDEP) Guided by a Dielectric Structure Between Two Planar Electrodes)

  • 추현정;도일;조영호
    • 대한기계학회논문집A
    • /
    • 제33권3호
    • /
    • pp.261-264
    • /
    • 2009
  • We present a three-dimensional (3D) particle focusing channel using the positive dielectrophoresis (pDEP) guided by a dielectric structure between two planar electrodes. The dielectric structure between two planar electrodes induces the maximum electric field at the center of the microchannel, and particles are focused to the center of the microchannel by pDEP as they flow from the single sample injection port. Compared to the previous 3D particle focusing methods, the present device achieves the simple and effective particle focusing function without any additional fluidic ports and top electrodes. In the experimental study, approximately 90 % focusing efficiency were achieved within the focusing length of 2mm, on both x-z plane (top-view) and y-z plane (side-view) for $2{\mu}m$-diameter polystyrene (PS) bead at the applied voltage over 15 Vp-p (square wave) and at the flow rate below 0.01 ${\mu}l$/min. The present 3D particle focusing channel results in a simple particle focusing method suitable for use in integrated microbiochemical analysis system.

대기 에어로졸 측정용 3단 임팩터의 설계 및 성능평가 (Design and Performance Evaluation of a Three Stage Impactor)

  • 지준호;배귀남;황정호
    • 한국대기환경학회지
    • /
    • 제17권6호
    • /
    • pp.441-450
    • /
    • 2001
  • A three stage impactor with the cutoff diameters of 1, 2.5, and 10$\mu\textrm{m}$ in aerodynamic diameter was developed and tested. The gravimetric method and the particle counting method were utilized to evaluate the collection performance of each stage. A vibrating orifice aerosol generator was employed to generate monodisperse test aerosols larger that 2$\mu\textrm{m}$ in diameter. Polystyrene latex (PSL) particles smaller than 2$\mu\textrm{m}$ in diameter were generated by an atomizer and the particle number concentration was measured by an Aerodynamic Particle Sizer Spectrometer. The experimental cutoff diameters obtained from the particle collection efficiency curves are in good agreement with the designed values. The square roots of Stokes number at 50% collection efficiency for stage 1, 2, and 3 are 0.42, 0.48, and 0.45, respectively. Effects of the particle bounce and the impaction plate on the collection efficiency were investigated. The collection efficiency curves including effect of the particle bounce were also compared with those of the MOUDI cascade impactor.

  • PDF

광학식 입자 계수기 내 샘플 노즐 직경이 측정 효율 및 특성에 미치는 영향에 대한 실험적 연구 (Experimental analysis on effects of nozzle diameter on detection characteristics of an optical particle counter)

  • 송현우;김태욱;송순호
    • 한국입자에어로졸학회지
    • /
    • 제13권4호
    • /
    • pp.159-164
    • /
    • 2017
  • The detection efficiency and characteristics of an optical particle counter (OPC), with various sample nozzle outlet diameters, were experimentally investigated. The OPC system, which was built with original design, was made up of a diode laser, two photodetectors, and a variety of optics such as a beam splitter and a concave mirror. The cone-shaped sampling nozzle was designed to be changeable to alter the outlet diameter, within the range of 1 to 3 mm. For samples, sets of polystyrene latex (PSL) standard particle with various sizes of 1 to $3{\mu}m$, were used. As a result, detection efficiency of the OPC greatly decreased with larger nozzle outlet diameter. Moreover, increased nozzle outlet diameter means broader sample flow, thus caused light interference and multiple scattering which results in abnormal high peaks in scattered light signal. The ratio of abnormal peaks to regular signal of single particle increased with larger nozzle outlet diameter.

폴리스티렌겔내에서 침전중합법에 의한 Poly(AA-co-EGDMA) Microgel의 합성 (Synthesis of Poly(AA-co-EGDMA) Microgels by Precipitation Polymerization in Polystyrene Gel)

  • 김공수;조병호;조석형
    • 공업화학
    • /
    • 제7권2호
    • /
    • pp.350-355
    • /
    • 1996
  • Poly(AA-co-EGDMA) microgel은 시크로헥산/아세톤용액에 팽윤된 폴리스티렌겔 용액중에서 침전중합 방법으로 합성하였다. Microgel을 합성함에 있어서 폴리스티렌의 농도, 가교제의 농도, 폴리스티렌과 모노머의 비율 및 용매의 성질에 따라 $0.18{\sim}0.55{\mu}m$의 입자크기로 조절할 수 있었으며, 구형의 단분산성 microgel을 합성할 수 있었다. 또한 폴리스티렌 용액의 농도가 증가함에 따라 microgel의 입자크기는 작아졌고, 가교제의 농도가 증가할 수록 입자크기는 증가하였다.

  • PDF

Synthesis of Quantum Dot-Tagged Submicrometer Polystyrene Particles by Miniemulsion Polymerization

  • Joumaa, Nancy;Lansalot, M.;Theretz, A.;Elaissari, A.;Sukhanova, A.;Artemyev, M.;Nabiev, I.;Cohen, J.H.M.
    • 한국고분자학회:학술대회논문집
    • /
    • 한국고분자학회 2006년도 IUPAC International Symposium on Advanced Polymers for Emerging Technologies
    • /
    • pp.330-330
    • /
    • 2006
  • The elaboration of fluorescent submicronic polymer particles exhibiting narrow particle size distribution as well as good photostability is of particular interest in various biomedical applications. In the frame of this work, labeled polystyrene latexes have been synthesized by miniemulsion polymerization using luminescent semiconductor nanoparticles (quantum dots, QD). The influence of incorporation of QDs on the polymerization kinetics as well as on the optical properties of the obtained latexes will be discussed.

  • PDF

폴리 아닐 린-DBSA/폴리스타이렌 블렌드의 전하 이동 현상 (Charge Transport Phenomena of Polyaniline-DBSA/Polystyrene Blends)

  • 김원중;김태영;고정우;김윤상;박창모;서광석
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권6호
    • /
    • pp.305-311
    • /
    • 2004
  • Charge transport phenomena of polyaniline-DBSA/High Impact Polystyrene (PAM-DBSA/HIPS) blends have been studied through an examination of electrical conduction. HIPS used host polymer in the blends and PANI-DBSA obey a space charge limited conduction mechanism and a ohmic conduction mechanism respectively. However, PANI-DBSA/HIPS blends do not obey any classical conduction mechanism. Analysis of conduction mechanism revealed that the charging current of PANI-DBSA/HIPS blends increased with the increase of PANI-DBSA content. This result migrlt be explained by the reduction in the distance between PANI-DBSA particles enabling the charge carriers to migrate from a chain to a neighboring chain via hopping or micro tunneling. It was also found that the charging current of PANI-DBSA/HIPS blends decreased as the temperature was elevated, which is of typical phenomena in metals. It is speculated that the charge transport in PANI-DBSA particle was somewhat constrained due to strong phonon scattering.

폴리스티렌 라텍스 제조에 있어서 Triton X-100/SDS 계면활성제 혼합이 단량체/수용액 간의 계면물성 및 라텍스의 특성에 미치는 영향 (The Effects of Interfacial Properties of the Styrene/Water on the Styrene Latex Particle Properties using Triton X-100/SDS Surfactant Mixture)

  • 박아름이;김영호
    • 한국응용과학기술학회지
    • /
    • 제27권3호
    • /
    • pp.240-248
    • /
    • 2010
  • The blending effects of surfactants on the polystyrene emulsion polymerization were studied. The blending of Triton X-100 and SDS affects to the interfacial properties of the styrene monomer and water phases, and finally, the properties of the polystyrene latex particles. As the blending ratio of SDS/Triton X-100 increases, the interfacial tension and CMC of the blended surfactants were decreased and results in a reducing the size of the latex particles. It was found that the interfacial tension was reduced when the surfactant were blended. By increasing the SDS content, the interfacial tension was reduced, and, at a certain condition, the interfacial tension was reached to an extremely low value to form micro-emulsion and the nano-sized latex particles (80~110 nm).

Separation and Characterization of Dust and Ground Water Particulates Using Gravitational SPLITT Fractionation.

  • 이승호;박희영;이상근;용성권;음철훈
    • Bulletin of the Korean Chemical Society
    • /
    • 제22권6호
    • /
    • pp.616-622
    • /
    • 2001
  • Split-flow thin (SPLITT) cell Fractionation(SF) is a technique that allows separation of particulates and macromolecules into two fractions. A gravitational SF(GSF) system is constructed and tested for its applicability for separation of dust and ground water particulates. When tested with polystyrene latex particles, experimental data were in good agreements with theory. The 9.8 and 21.4㎛ polystyrene particles were successuflly separated in a continuous mode, where the mixture is continuously fed into the GSF channel allowing separation in a large sacle. The GSF system is successfully applied to continuous separation of dust and ground water particels based on the sedimentation coefficient, which is closely related to the particle size. The separations were confirmed by microscopy and energy-dispersive X-ray (EDX) analysos.

Study of micro-plastics separation from sea water with electro-magnetic force

  • Nomura, Naoki;Mishima, Fumihito;Nishijima, Shigehiro
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제23권3호
    • /
    • pp.10-13
    • /
    • 2021
  • The method of removing micro-plastics from sea water has been developed using electro-magnetic force. Plastics are difficult to decompose and put a great load on the marine environment. Especially a plastic with a size of 5 mm or less is defined as micro-plastic and are carried by ocean currents over long distances, causing global pollution. These are not easily decomposed in the natural environment. The Lorentz force was generated in simulated sea water and its reaction force was applied to the micro-plastic to control their motion. Lorentz force was generated downward and the reaction force to the plastics was upward. The plastic used in the experiment was polystyrene with a diameter of 6 mm, and the density was 1.07 g/cm3. The polystyrene sphere levitated at the current density of 0.83 A/cm2 and the external field of 0.87T. The particle trajectory calculation was also made to design separation system using superconducting magnet.