• 제목/요약/키워드: polymerization time

검색결과 515건 처리시간 0.027초

Novel pH/Temperature Sensitive Hydrogels of Poly (ethylene glycol)-Poly (caprolactone) -Poly (${\beta}-amino\;ester$) (PAE-PCLA-PEGPCLA-PAE) Biodegradable Polyester Block Copolymer

  • Huynh Dai Phu;Lee Doo-Sung
    • 한국고분자학회:학술대회논문집
    • /
    • 한국고분자학회 2006년도 IUPAC International Symposium on Advanced Polymers for Emerging Technologies
    • /
    • pp.263-263
    • /
    • 2006
  • Poly (ethylene glycol)(PEG) - Poly (${\varepsilon}-caprolactone(CL)$) - Poly (D,L lactide(LA) (PCLA-PEG-PCLA) was synthesized by ring-opening polymerization to form temperature sensitive hydrogel triblock copolymer. The triblock copolymer was acrylated by acryloyl chloride. ${\beta}-amino$ ester was used as a pH sensitive moiety, in this study ${\beta}$- amino ester obtained from 1,4-butandiol diacrylate, and 4, 4' trimethylene dipiperidine, it have pKb around 6.6. pH/temperature sensitive penta-block copolymer (PAE-PCL-PEG-PCL-PAE) was synthesized by addition polymerization from acrylated triblock copolymer, 1,4-butandiol diacrylate, and 4, 4' trimethylene dipiperidine. Their physicochemical properties of triblock and penta-block copolymers were characterized by $^1H-NMR$ spectroscopy and gel permeation spectroscopy. Sol-gel phase transition behavior of PAE-PCL-PEG-PCL-PAE block copolymers were investigated by remains stable method. Aqueous media of the penta-block copolymer (at 20 wt%) changed from a sol phase at pH 6.4 and $10^{\circ}C$ to a gel phase at pH 7.4 and $37^{\circ}C$. The sol-gel transition properties of these block copolymers are influenced by the hydrophobic/hydrophilic balance of the copolymers, block length, hydrophobicity, stereo-regularity of the hydrophobic of the block copolymer, and the ionization of the pH function groups in the copolymer depended on the changing of environmental pH, respectively. The degradation and the stabilization at pH 7.4 and $37^{\circ}C$, and the stabilization at pH 6.4 and $10^{\circ}C,\;5^{\circ}C,\;0^{\circ}C$, of the gel were determined. The results of toxicity experiment show that the penta block copolymer can be used for injection drug delivery system. The sol?gel transition of this block copolymer also study by in vitro test ($200{\mu}l$ aqueous solution at 20wt% polymer was injected to mouse). Insulin loading and releasing by in vitro test was investigated, the results showed that insulin can loading easily into polymer matrix and release time is around 14-16days. The PAE-PCL-PEG-PCL-PAE can be used as biomaterial for drug, protein, gene loading and delivery.

  • PDF

感光性 樹脂에 關한 硏究 (第10報). Naphthoquinone-1,2-diazide-5-sulfonyl Esters의 感光性과 分光感度 (Studies on Photosensitive Polymers (X). Studies on Photosensitivity and Spectral Sensitivity of Naphthoquinone-1,2-diazide-5-sulfonyl Esters)

  • 심정섭;강두환
    • 대한화학회지
    • /
    • 제19권4호
    • /
    • pp.269-279
    • /
    • 1975
  • 合成한 pllyglyceryl phthalate, bisphenol A-epichlorohydrin 축중합물과 polyvinyl alcohol의 naphthoquinone-1,2-diazide-5-sulfonyl esters(PGND, BEND 및 PVAND)의 感光特性을 지배하는 諸因子를 이들에 대한 光照射前後의 溶解度 차이에 의하여 檢討하였다. 유리 또는 石英支持薄板上에 塗布한 各試料를 各種條件下에서 露光하고 알카리 水溶液에 침지시킨 다음 塗布된 필림의 殘膜收率(W/W0)을 計算하였다. 필름의 感光度와 직접적인 관계가 있는 殘膜收率은 母體樹脂의 重合度, 增感劑의 種類 및 添加濃度에 따라 영향이 있었다. 母體樹脂의 重合度가 크면 클수록 感光性이 더 우수하였으며, 增感劑의 添加濃度는 5%일때가 가장 좋은 效果를 나타내었다. PGND, BEND 및 PVAND에 대해 본실험에서 사용한 各種 增感制 중에서 가장 效果的인 것은 benzanthrone, 5-nitroacenaphthene, picramide이였다. 이들 樹脂와 增感劑를 添加한 경우의 固相에 있어서의 紫外線吸收스펙트럼과 感色性 寫眞을 각각 비교 검토하여 그 增感과 分光感度的 特性을 糾明하였다. PGND, BEND 및 PVAND는 使用한 增感制에 의하여 光學增感하였으며 增感效果가 현저한 것일수록 그 感光波長城이 長波長쪽으로 伸張하였다. 未增感, 增感試料에 있어서 分光吸收 極大 波長城과 分光感光極大波長城이 거의 一致하고 있는 점으로 보아 試料 樹脂들에 의해서 吸收된 波長城의 光은 그 分野에 有效하게 使用되고 있음을 확인하였다

  • PDF

대기 조건에서 경화가 가능한 텅스텐계 p-DCPD의 개선된 성형 방법 (An Improved Manufacturing Method of p-Dicyclopentadiene (DCPD) using Tungsten Type Catalyst in Air Condition)

  • 권동준;신평수;김종현;박종만
    • Composites Research
    • /
    • 제29권4호
    • /
    • pp.216-222
    • /
    • 2016
  • 폴리디싸이클로팬타디엔 (p-DCPD) 수지를 경화하기 위해 개환반응이 사용된다. 이 반응은 텅스텐계 촉매를 이용한 반응이기 때문에 질소 조건에서 반응이 진행되어야 한다. 왜냐하면, 텅스텐계 수지는 촉매독 현상이 발생될 수 있기 때문에 대기조건에서는 사용이 어려운 것으로 알려져 있다. 이러한 문제를 개선하기 위해 본 연구에서는 대기 조건에서 텅스턴 (W)을 촉매로한 p-DCPD 대해 프레스 성형법을 이용하여 수지를 경화시켰다. 프레스 성형을 통해 p-DCPD (W) 수지를 경화시킬 경우 기계적 강도가 향상되는 결과를 얻었으며, 이는 DCPD 성형 단계에서 발생되는 기체를 압으로 눌러 미세 기공의 발생을 줄였기 때문이다. 촉매 독 현상이 발생되는 것은 반응시간이 길 때에 발생되지만, 짧은 성형을 시도하는 프레스 성형에서는 촉매 자체로 인한 물성 저하가 발생되지 않았다. 궁극적으로 p-DCPD 성형을 위해 대기 조건에서 성형이 가능하였으며, 경화 시간, 압력 변수를 조절할 경우 기계적 물성이 향상을 확인하였다.

UV-A 반복노출로 인한 항산화효소의 구조변성과 효소활성의 상관관계 (The Relationship between Structural Denaturation of Antioxidative Enzymes and Their Enzyme Activity due to Repeated Exposure to UV-A)

  • 박미정;유효정;김종찬;김소라
    • 한국안광학회지
    • /
    • 제20권1호
    • /
    • pp.75-81
    • /
    • 2015
  • 목적: 본 연구는 안구에 존재하는 항산화효소인 superoxide dismutase(SOD)와 catalase(CAT)가 UV-A에 반복적으로 노출되었을 때 이들의 구조 및 활성의 변화가 유발되는지 알아보고 이들의 상관관계를 밝히고자 수행되었다. 방법: SOD와 CAT의 표준품으로 각각의 효소용액을 제조하고 하루 30분, 1시간 및 2시간씩 365 nm의 UV-A에 노출시키는 조건으로 1, 2, 3, 4 및 5일 동안 UV-A에 반복적으로 노출시켰다. UV-A 반복노출에 따른 SOD와 CAT의 구조변성은 전기영동분석으로 확인하였으며, 이들 효소의 활성은 분석키트를 이용하여 비색분석법으로 측정하였다. 결과: UV-A에 반복노출된 SOD는 일일 1시간 이상 조건으로 반복노출되었을 때 전기영동분석에서 효소의 다중화(polymerization)가 관찰되었으나 활성의 변화는 12% 이내로 나타났다. 반면 UV-A에 반복노출된 CAT는 전기영동 시 효소의 밴드크기가 감소하여 구조변성이 나타났음을 알 수 있었으며, 효소활성 또한 유의하게 감소됨을 확인하였다. 반복노출시간이 긴 경우 CAT은 전기영동분석에서는 효소밴드를 보임에도 불구하고 그 활성은 완전히 소실됨을 알 수 있었다. 결론: 이상의 결과로 UV-A 반복노출에 따른 항산화효소의 구조변성은 효소의 종류에 따라 그 정도와 양상이 다르게 나타나며, 구조변성이 효소활성의 감소정도와 반드시 일치하는 것은 아님을 알 수 있었다.

N-Methyl-p-Aminophenol의 酸化重合機構 및 生成重合體의 熱特性 (The Mechanism to Oxidative Polymerization of N-Methyl-p-Aminophenol and Thermal Characteristics of the Polymer Formed)

  • 최규석
    • 대한화학회지
    • /
    • 제16권5호
    • /
    • pp.314-319
    • /
    • 1972
  • N-methyl-p-aminophenol은, 酸素存在下, 철-킬레이트(Fe(III)-EDTA) 水溶液中에서 酸化重合하여 黑色의 Oligo-(N-methyl-p-aminophenol)을 定量的으로 生成한다. 이 酸化重合過程에서 單量體中의 N에 結合된 $CH_3$ group이 일부 脫離되는데, 이것은 oligo-(N-methyl-p-aminophenol)을 아세톤처리하여 얻은 아세톤 可溶部와 不溶部의 赤外線스펙트럼에서 ${\delta}\;asym\;CH_3\;1460\;cm^{-1}$${\delta}\;sym\;CH_3\;1380\;cm^{-1}$의 吸收가 候者의 경우 현저히 弱化된 것으로 明白하다. $N_2$氣流中에서 每分 $2^{\circ}C$의 上昇速度로 行한 TGA分析結果, $600^{\circ}C$에서 약 40%의 重量損傷을 나타내며, $CH_3$ 置換基가 없는 p-aminophenol보다 耐熱性이 떨어진다. 또한 이 生成올리고머의 He 氣流中에서 행한 熱分解反應에서의 生成物은 單量體인 N-methyl-p-aminophenol과 물이 確認되었고 分解가스로부터는 gas chromatography에서 $H_2,\;CO,\;CO_2$등이 確認되었다. 生成올리고머의 熱處理에서는 일부는 1次元的인 構造가 切斷되어 單量體로 分解되지만, 대부분은 melt polycondensation이 일어나 더 큰 重合體로 변함과 동시에 熱에 安定한 環式構造로 변하여 감이 確認되었다

  • PDF

광원의 종류에 따른 복합레진의 중합거동 및 중합률에 관한 연구 (THE POLYMERIZATION RATE AND THE DEGREE OF CONVERSION OF COMPOSITE RESINS BY DIFFERENT LIGHT SOURCES)

  • 류주희;이인복;유현미;김미자;석창인;권혁춘
    • Restorative Dentistry and Endodontics
    • /
    • 제29권4호
    • /
    • pp.386-398
    • /
    • 2004
  • Objectives: The purpose of this study was to observe the reaction kinetics and the degree of polymerization of composite resins when cured by different light sources and to evaluate the effectiveness of the blue Light Emitting Diode Light Curing Units (LED LCUs) compared with conventional halogen LCUs. Materials and Methods: First, thermal analysis was performed by a differential scanning calorimeter (DSC). The LED LCU (Elipar Freelight, $320{\;}mW/\textrm{cm}^2$) and the conventional halogen LCU (XL3000, $400{\;}mV/\textrm{cm}^2$) were used in this study for curing three composite resins (SureFil, Z-250 and AEliteFLO). Second. the degree of conversion was obtained in the composite resins cured according to the above curing mode with a FTIR. Third, the measurements of depth of cure were carried out in accordance with ISO 4049 standards. Statistical analysis was performed by two-way ANOVA test at 95% levels of confidence and Duncan's procedure for multiple comparisons. Results: The heat of cure was not statistically different among the LCUs (p > 0.05). The composites cured by the LED (Exp) LCUs were statistically more slowly polymerized than by the halogen LCU and the LED (Std) LCU (p < 0.05). The composite resin groups cured by the LED (Exp) LCUs had significantly greater degree of conversion value than by the halogen LCU and the LED (Std) LCU (p =0.0002). The composite resin groups cured by the LED (Std) LCUs showed significantly greater depth of cure value than by the halogen LCU and the LED (Exp) LCU (p < 0.05).

루테늄촉매 활성정도에 따른 유리섬유/폴리다이사이클로펜타다이엔 복합재료의 기계 및 계면물성 변화 (The Change in Interfacial and Mechanical Properties for Glass Fiber/p-DCPD Composites with Degree of Ruthenium Catalyst Activation)

  • 신평수;김종현;백영민;박하승;권동준;박종만
    • 접착 및 계면
    • /
    • 제19권1호
    • /
    • pp.13-18
    • /
    • 2018
  • 루테늄촉매는 대기중에 노출되었을 때, 촉매활성정도가 떨어지게 된다. 루테늄 촉매의 촉매활성변화를 대기노출 일수에 따라 표면장력방법을 이용하여 정량적으로 확인하였다. 각 대기노출일수에 따른 루테늄 촉매를 이용하여 DCPD 중합 후 기계 및 계면물성변화를 확인하였다. 희석제와 10:1로 섞인 루테늄 촉매를 대기 중에 노출 시킨 후 각 일수에 따라 색깔 관찰하였다. 윌헴리 및 PTFE를 이용하여 표면장력을 구하고 이를 촉매활성 정도와 연관시켰다. 각 촉매를 이용하여 DCPD를 중합시키는 데 발열량을 실시간으로 측정하였다. 경화 후 p-DCPD에 대하여 인장강도를 측정하여 물성감소정도를 확인하였다. 또한, 유리섬유 간 마이크로드롭렛 풀 아웃 실험을 통하여 계면물성 또한 파악하였다. 표면장력방법을 통하여 촉매활성 정도를 확인하였을 때, 4일까지는 33 dyne/cm로 안정적이었지만, 6일 이후로 표면장력이 34 dyne/cm 이상 증가하는 것을 확인하였고, 이는 촉매의 산화와 연관시킬 수 있었다. 기계적 물성 확인하였을 때, 인장강도 및 계면강도 또한 6일 (인장강도: 38 MPa. 계면전단 강도: 26 MPa) 까지는 안정적이었지만 10일 (인장강도: 15 MP. 계면전단강도: 3 MPa) 이후로 물성이 급격하게 감소하는 것을 확인하였다.

1급 와동에서 상아질과 복합레진의 결합강도에 대한 중합방법의 효과 (THE EFFECT OF DIFFERENT CURING MODES ON COMPOSITE RESIN/DENTIN BOND STRENGTH IN CLASS ICAVITIES)

  • 백신영;조영곤;송병춘
    • Restorative Dentistry and Endodontics
    • /
    • 제33권5호
    • /
    • pp.428-434
    • /
    • 2008
  • 본 연구는 1급 복합레진 수복물에서 할로겐 광조사기를 이용한 4가지 중합방법이 상아질의 결합강도에 미치는 효과를 알아보기 위하여 시행하였다. 발거된 상 하악 대구치 20개의 교합면측 법랑질을 Diamond Wheel Saw를 이용하여 제거한 후 1급 와동을 형성하였다. 중합방법에 따라 파동지연 중합방법 (PD) 군, 연성 중합방법 (SS) 군, 파동 중합방법 (PC) 군, 지속 중합방법 (CC) 군의 4개 군으로 분류하고, Z250 복합레진을 각 군의 와동에 충전한 후 광조사하였다. 각 군의 시편을 주수하에 접착계면의 단면적이 $1mm^2$가 되도록 절단하여 막대모양의 시편을 제작하였고, 각 군당 20개의 시편을 사용하여 미세인장 결합강도를 측정하여 다음과 같은 결과를 얻었다. 1. PD 군은 PC 군과 CC 군보다 통계학적으로 더 높은 미세인장 결합강도를 나타내었다. 2. SS군의 미세인장 결합강도는 PC 군과 CC 군보다 높게 나타났으나, 통계학적으로 유의한 차이를 나타내지 않았다. 결론적으로, 1급 복합레진 수복물을 중합할 때 파동지연 중합방법과 연성 중합방법을 사용하여 중합속도를 조절함으로써 상아질과 복합레진의 결합강도를 개선할 수 있을 것으로 사료된다.

실크 세리신의 가수분해 특성과 응용 I. 세리신의 분자량 제어 (Hydrolysis characteristics and applications of silk sericin I. Control of molecular weight of sericin)

  • 김정호;배도규
    • 한국잠사곤충학회지
    • /
    • 제45권1호
    • /
    • pp.46-57
    • /
    • 2003
  • 정련 액에서 수용성 세리신을 얻고, 남은 난용성 세리신을 여러가지 효소로 가수분해하여, 효소 가수분해 특성을 알아보고. 아미노산 조성과 분자량을 조사하여 다음과 같은 결론을 얻었다. 1. 효소 가수분해 시 kojizyme과 flavourzyme의 최적조건은 pH 7, 온도 5$0^{\circ}C$이었고, protamex와 alcalase는 처리 pH의 증가에 따라 활성이 높았고 최적온도는 6$0^{\circ}C$이었다. 2 효소 가수분해 시 용해도 측정에서는 효소 처리농도 증가에 따라 용해도도 높았으며, 4시간 이상의 처리에서는 아주 소폭으로 용해도가 증가하였다. 3. 효소 가수분해 시 흡광도를 이용한 용해도 측정에서는 효소 처리농도 증가에 따라 흡광도도 높았으며. 4시간 이상의 처리에서도 계속하여 흡광도가 증가하였다. 4. 효소 가수분해 시 말단기 정량에 의한 평균중합도 측정에서는 처리시간과 농도의 증가에 따라 중합도가 감소하였다. 5. 아미노산 분석 결과 정련 후 채취한 low와 high의 아미노산 조성이 비슷하고, PK와 PP및 PA의 아미노산 조성이 비슷하였으며, low와 high는 PK, PP, PA보다 세린과 타이로신의 함량이 많았고, 프롤린은 검출되지 않았다. 6. GPC에 의한 분자량 측정결과 중량평균분자량(Mw) 크기는 PK>high>PP>low>PA 순서이었으며, PK와 PA의 Mw는 각각 9,800, 905이었다

Polyaniline을 이용한 CNT fiber 유연 전극 기반의 비효소적 글루코스 검출 (Enzyme-Free Glucose Sensing with Polyaniline-Decorated Flexible CNT Fiber Electrode)

  • 송민정
    • Korean Chemical Engineering Research
    • /
    • 제60권1호
    • /
    • pp.1-6
    • /
    • 2022
  • 최근 웨어러블 디바이스에 대한 수요가 증가하면서 유연 전극 소재 개발에 대한 다양한 연구들이 진행되고 있다. 특히, 헬스케어용 웨어러블 센서들은 체온이나 심장 박동, 혈당, 혈중 산소 농도 등 신체 정보들의 실시간·지속적인 모니터링과 정확한 진단, 검출이 가능해야 하기 때문에 고성능 유연 전극 소재의 개발이 무엇보다 중요하다. 본 연구에서는 탄소나노튜브 섬유(carbon nanotube fiber; CNT fiber) 기반의 유연 전극 소재의 성능을 개선시키기 위해 CNT fiber 위에 전기화학적 중합(electrochemical polymerization) 공정을 통해 polyaniline (PANI) layer를 합성하고, 이에 대한 전기화학적 특성 분석과 비효소적 글루코스(glucose) 검출 특성을 확인하였다. 제작된 PANI/CNT fiber 전극의 표면 분석은 주사전자 현미경(SEM)을 이용하여 진행되었으며, 전극의 전기화학적 특성 및 글루코스에 대한 센싱 성능은 시간대전류법(CA)과 순환전압 전류법(CV), 전기화학 임피던스법(EIS)을 이용하여 분석되었다. PANI/CNT fiber 전극의 전기화학적 특성은 bare CNT fiber 전극에 비해 작은 electron transfer resistance와 낮은 peak separation potential, 증가된 전극 면적을 나타내며, 이런 향상된 특성들 덕분에 글루코스 검출에 대한 센싱 성능이 개선되었다. 따라서, 본 연구를 기반으로 다양한 나노구조체를 도입하고 접목을 통해 고성능 CNT fiber 기반의 유연 전극 소재 개발이 가능할 것으로 기대된다.