• 제목/요약/키워드: polymerization shrinkage

검색결과 121건 처리시간 0.033초

LED를 이용한 복합레진의 광조사시, 중합수축의 속도와 양, 미세경도에 관한 연구 (THE AMOUNTS AND SPEED OF POLYMERIZATION SHRINKAGE AND MICROHARDNESS IN LED CURED COMPOSITES)

  • 박성호;김수선;조용식;이순영;김도현;장용주;문현승;서정원;노병덕
    • Restorative Dentistry and Endodontics
    • /
    • 제28권4호
    • /
    • pp.354-359
    • /
    • 2003
  • This study evaluated the effectiveness of the light emitting diode(LED) units for composite curing. To compare its effectiveness with conventional quartz tungsten halogen (QTH) light curing unit. the microhardness of 2mm composite. Z250, which had been light cured by the LEDs (Ultralume LED2, FreeLight, Developing product Dl) or QTH (XL 3000) were compared on the upper and lower surface. One way ANOVA with Tukey and Paired t-test was used at 95% levels of confidence. In addition. the amount of linear polymerization shrinkage was compared between composites which were light cured by QTH or LEDs using a custom-made linometer in 10s and 60s of light curing, and the amount of linear polymerization shrinkage was compared by one way ANOVA with Tukey. The amount of polymerization shrinkage at 10s was XL3000 > Ultralume 2. 40. 60 > FreeLight, D1 (P<0.05) The amount of polymerization shrinkage at 60s was XL3000 > Ultralume 2, 60> Ultralume 2.40 > FreeLight, D1 (P<0.05) The microhardness on the upper and lower surface was as follows ; (equation omitted) It was concluded that the LEDs produced lower polymerization shrinkage in 10s and 60s compared with QTH unit. In addition. the microhardness of samples which had been cured with LEDs was lower on the lower surfaces than the upper surfaces whereas there was no difference in QTH cured samples.

점도, 시편형태 그리고 접착의 유무가 광중합 복합레진의 선형중합수축의 측정에 미치는 영향 (THE EFFECT OF VISCOSITY, SPECIMEN GEOMETRY AND ADHESION ON THE LINEAR POLYMERIZATION SHRINKAGE MEASUREMENT OF LIGHT CURED COMPOSITES)

  • 이인복;손호현;권혁춘;엄정문;조병훈
    • Restorative Dentistry and Endodontics
    • /
    • 제28권6호
    • /
    • pp.457-466
    • /
    • 2003
  • The aim of study was to investigate the effect of flow, specimen geometry and adhesion on the measurement of linear polymerization shrinkage of light cured composite resins using linear shrinkage measuring device. Four commercially available composites - an anterior posterior hybrid composite Z100, a posterior packable composite P60 and two flowable composites, Filtek flow and Tetric flow-were studied. The linear polymerization shrinkage of composites was determined using 'bonded disc method' and 'non-bond-ed' free shrinkage method at varying C-factor in the range of 1∼8 by changing specimen geometry. These measured linear shrinkage values were compared with free volumetric shrinkage values. The viscosity and flow of composites were determined and compared by measuring the dropping speed of metal rod under constant load. In non-bonded method, the linear shrinkage approximated one third of true volumetric shrink-age by isotropic contraction. However, in bonded disc method, as the bonded surface increased the linear shrinkage increased up to volumetric shrinkage value by anisotropic contraction. The linear shrinkage value increased with increasing C-factor and approximated true volumetric shrinkage and reached plateau at about C-factor 5∼6. The more flow the composite was, reduced linear shrinkage was measured by compensation radial flow.

섬유 보강 복합레진의 섬유 방향이 중합수축에 미치는 영향 (EFFECT OF FIBER DIRECTION ON THE POLYMERIZATION SHRINKAGE OF FIBER-REINFORCED COMPOSITES)

  • 염중원;이인복
    • Restorative Dentistry and Endodontics
    • /
    • 제34권4호
    • /
    • pp.364-370
    • /
    • 2009
  • 본 연구의 목적은 strain gage와 LVDT (linear variable differential transformer) 변위센서를 이용하여 섬유 보강 복합레진에서 섬유의 방향이 복합레진의 중합수축에 미치는 영향을 알아보기 위함이다. 지름 10 mm, 높이 2 mm의 원반 모양 유동성 복합레진 (Aeliteflo A2, Bisco, Inc., IL, USA) 중앙에 유리섬유 (X-80821P Glass Fiber, Bisco, Inc., IL, USA)를 위치시키고, 섬유가 배열된 장축 방향 (longitudinal)과 수직방향 (transversal)의 중합수축량을 strain gage (Linear S-series 350${\Omega}$, CAS, Seoul, Korea)를 이용하여 각각 측정하였다. 사용된 유동성 복합레진 자체의 free 중합수축을 구하기 위해 지름 7 mm, 높이 1 mm의 원반 모양 시편의 수직 방향 (axial) free 중합수축값을 LVDT로 측정하였다. 중합된 시편들을 절단하여 주사전자현미경으로 복합 레진 내부의 섬유배열을 관찰하고 각 군에서 측정된 평균 수축값들을 ANOVA로 비교하였고 Scheffe post-hoc test로 사후 검정하였다 (${\alpha}$=0.05). 섬유가 배열된 평면 상에서 복합레진의 중합수축 (radial shrinkage)은 섬유와 평행한 방향에서 감소하고 섬유와 수직한 방향에서 증가했다 (p<0.05). 본 연구의 결과 섬유 보강 복합레진으로 스플린트나 수복물을 제작할 때 중합수축량은 보강된 섬유의 배열방향에 따라 큰 차이가 남을 알 수 있었다.

Methacrylate 기질 복합레진과 Silorane 기질 복합레진의 치아 수복 시 중합수축응력거동 (Behavior of Polymerization Shrinkage Stress of Methacrylate-based Composite and Silorane-based Composite during Dental Restoration)

  • 박정훈;최낙삼
    • Composites Research
    • /
    • 제28권1호
    • /
    • pp.6-14
    • /
    • 2015
  • 치아의 수복에 사용되는 재료인 Methacrylate 기질 복합레진(Clearfil AP-X)과 Silorane 기질 복합레진(Filtek P90)을 대상으로 스트레인게이지법과 FEM 분석법으로 중합수축응력거동을 분석하였다. 또한 복합레진의 탄성계수와 수축변형률을 중합수축응력과 관계시켜 이론식을 제시하고 이 식의 계산결과와 FEM 분석법의 결과를 비교하였다. 스트레인 게이지법으로 측정한 결과, 중합수축응력의 최대값은 Clearfil AP-X가 Filtek P90 보다 약 2.8배 높게 나타났다. FEM 분석 결과, Von-Mises 응력은 복합레진 수복재와 PMMA 링사이의 계면부에서 최대로 되었으며 시편표면의 계면부가 내부보다 응력집중이 더 컸음을 알았다. 예측식을 통한 반경 방향의 수축응력은 평면응력상태의 FEM 분석법을 통한 값과 비교하여 오차 5% 이내로 정확했음을 확인하였다.

상아질 접착제의 중합 시간 조절에 따른 복합레진의 중합 수축 방향의 변화 (THE EFFECT OF ADHESIVE CURING TIMING ON THE DIRECTION OF POLYMERIZATION SHRINKAGE OF COMPOSITE RESIN)

  • 배지현;오명환;김창근;손호현;엄정문;조병훈;권혁춘
    • Restorative Dentistry and Endodontics
    • /
    • 제26권4호
    • /
    • pp.316-325
    • /
    • 2001
  • The purpose of this study was to evaluate the effect of adhesive curing timing on the direction of polymerization shrinkage of light-curing composite resin. In this study, the curing times of adhesive and composite resin were measured by differential scanning calorimeter(DSC). 28 extracted human molars were embedded in clear resin and box-type cavities were prepared. Based on DSC data, the experimental teeth were divided into 4 groups. Group 1: no bond; Group 2: late curing; Group 3: Intermediate curing; Group 4: Early curing. After treating with adhesive, the buccal cavities were filled with Z-100 hybrid composite resin and the lingual ones were filled with AEliteflo flowable composite resin. The depressions at the surface were measured by surface profilometer, then the specimens were embedded in clear resin and sectioned. Impressions were obtained and used to get epoxy resin replicas. The epoxy replicas were gold-coated and observed under SEM. Average Maximum Gap(AMG), Gap Proportion(GP), Average Marginal Index(AMI) were used to compare the shrinkage gap of each group. The results were statistically analyzed using the Kruskal-Wallis One Way ANOVA, Student-Newman-Keuls method. The results of this study were as follows. 1. Average Maximum Gap, Gap Proportion, Average Marginal Index and depression at the surface or Z-100 hybride composite resin were smaller than those of AEliteflo flowable composite resin(P<0.05). 2. When the bonding between composite resin and tooth structure was strong, the shrinkage gap was small, and depression at the surface was deep(P<0.05). 3. In the well-bonded group, light-curing composite resin shrank toward bonded cavity wall, not toward light source. The result suggested that the direction of polymerization shrinkage was affected by the quality of bonding in the dentin-resin interface. The strong was the bonding between composite resin and tooth structure, the smaller was the gap and the deeper was the depression at the surface. Then the flow to compensate the polymerization shrinkage proceeded from surface to bonded cavity wall.

  • PDF

교두변위와 선수축량의 연관성 분석 (Correlation between Linear polymerization shrinkage & tooth cuspal deflection)

  • 이순영;박성호
    • Restorative Dentistry and Endodontics
    • /
    • 제30권6호
    • /
    • pp.442-449
    • /
    • 2005
  • 이 논문의 목적은 복합레진과 컴포머에서, 중합수축의 양과 이로 인하여 야기되는 교두변위와의 상관관계를 알아보기 위함이다. 수복재료로서 Dyract AP, Compoglass F, Z100, Surefil, Pyramid, Synergy Compact, Heliomolar와 Heliomolar HB가 사용되었으며, 접착제로서는 SE Bond 가 사용되었다. 수복재료의 중합수축의 양을 측정하기 위하여, 자체 제작한 linometer를 사용하여, 60초간 일어나는 선수축량을 측정하였다. 한 수복재료 당 10회 측정하였으며, one way ANOVA와 사후검정방법으로 Tukey Test를 이용하여 $95\%$ 신뢰수준에서 각 수복재료의 중합수축량의 차이를 비교하였다. 치아에서 일어나는 교두변위의 양을 측정하기 위하여 사람의 상악소구치에 표준화된 MOD 와동을 형성하고(깊이 3mm, 넓이 3.5mm), 접착제를 도포한 후 광조사 시킨 후, 수복재료로 충전하였다 치아를 자체 제작한 교두변위 측정장치에 위치시키고, 광조사 시키고, 이 때 발생하는 교두의 변위를 10분간 측정하였다. 한 수복재료 당 15회를 측정하였으며 one way ANOVA와 사후검정방법으로 Tykey Test를 이용하여 $95\%$ 신뢰수준에서 각 수복재료의 교두변위 량의 차이를 비교하였다. 중합수축의 양과 교두변위의 양의 상관관계를 회귀분석법을 이용하여 분석하였다. 중합수축의 양은 Heliomolar, Surefil < Heliomolar HB < Z100, Synergy Compact < Dyract AP, Pyramid, Compoglass F (p < 0.05), 교두변위의 양은 Heliomolar, Surefil, Z100, Heliomolar HB, Synergycompact < Compoglass F < Pyramid, Dyract AP (p < 0.05) 였다. 중합수축의 양과 교두변위는 높은 상관관계를 나타내었다 (p < 0.001).

즉시 광중합과 지연 광중합이 이원 중합 레진시멘트의 중합 수축량에 미치는 영향 (Effects of immediate and delayed light activation on the polymerization shrinkage-strain of dual-cure resin cements)

  • 이소연;김성훈;하승룡;최유성;김희경
    • 대한치과보철학회지
    • /
    • 제52권3호
    • /
    • pp.195-201
    • /
    • 2014
  • 목적: 본 연구에서는 세 가지 중합 방법에 따른 이원 중합 레진 시멘트의 중합 수축률을 비교하고 광조사가 중합 정도에 미치는 영향에 관하여 알아보고자 하였다. 재료 및 방법: 네 가지 종류의 이원 중합형 레진 시멘트(Smartcem 2, Panavia F 2.0, Clearfil SA Luting, Zirconite)가 사용되었다. 각 재료 당 세가지 서로 다른 중합 방법(자가 중합, 즉시 광중합, 5분 지연 광중합)으로 중합하였으며, 각 방법 당 5개의 시편을 사용하였다. Bonded disk method를 사용하여 $37^{\circ}C$에서 30분간, 시간에 따른 중합 수축률을 측정하였다. 측정값은 일원분산분석과 다중 분석을 위한 Scheff$\acute{e}$ test를 사용하였고, 유의수준은 0.05으로 하였다. 결과: Panavia F 2.0를 제외한 나머지 세 종류의 이원 중합 레진 시멘트들은 지연 광중합 반응에서 가장 높은 중합 수축률을 보였다. Panavia F 2.0의 중합 수축률은 중합 방법간에 통계학적 유의성이 없었다. 중합이 개시된 초기 10분 내에 즉시 혹은 지연 광중합에서 모든 시멘트는 90% 이상의 중합수축을 보였다. 결론: 이원 중합 레진 시멘트의 지연 광중합이 중합 효율을 높인다.

치과용 레진 시멘트의 중합 수축률 특성에 관한 연구 (In vitro study of Polymerization shrinkage-strain kinetics of dental resin cements)

  • 김태훈;양재호;이재봉;한중석;김성훈
    • 대한치과보철학회지
    • /
    • 제48권1호
    • /
    • pp.55-60
    • /
    • 2010
  • 연구 목적: 치과용 레진시멘트의 중합 수축은 수복물이 치아에 정확하게 합착되는 것을 방해하고, 내부 응력의 원인이 되어 치아에 여러 문제점을 일으킬 수 있다. 이러한 임상적인 문제점을 줄이기 위해서 사용하는 치과용 레진시멘트의 중합 수축률에 대해 아는 것이 중요하다. 본 연구에서는 상업적으로 이용되고 있는 몇 가지 레진시멘트의 시간에 따른 중합 수축률을 측정, 서로 비교하고자 하였다. 연구 재료 및 방법: 3종류의 자가 중합형 레진시멘트(Fujicem, Superbond, M bond)와 3종류의 이원 중합형 레진시멘트(Maxcem, Panavia F, Variolink II) 별로 각각 5개의 시편을 이용하였다. 각 재료의 중합 수축률은 Bonded disk method를 이용하여 측정하였다. 안쪽 직경 16 mm, 두께 1 mm 의 동으로 제작된 링을 유리판 ($74\;mm\;{\times}\;25\;mm\;{\times}\;3\;mm$) 위의 중앙에 위치시켜 부착하고, 그 유리판 중앙에 실험 재료를 구 형태로 만들어 올리고, 다른 유리판으로 눌러서 원판 형태 (직경 8 mm, 두께 1 mm)의 시편을 제작하였다. 시편의 중합 수축률은 재료가 중합이 시작된 후 120분동안, $23^{\circ}C$에서 측정하였다. 시간에 따른 수축량에 대한 kinetics curve를얻고, 각 실험 재료의 수축률의 평균값 (%)과 표준편차를 구한 뒤, one-way ANOVA 및 Scheffe post hoc test를 유의수준 0.05 에서 처리하여 그 결과 값을 비교하였다. 결과: 1. 실험에 사용된 Fujicem, Maxcem, M bond, Panavia F, Superbond, Variolink II 은 중합이 시작 된 120 분 후의 중합 수축률이 각각 3.72%, 4.19%, 4.13%, 2.44%, 7.57%, 2.90%의 값을 보였다. 2. Panavia F가 중합 수축률이 가장 작았고, Superbond가 중합 수축률이 가장 컸다 (P<.05). 3. Maxcem 과 M Bond 간에는 유의한 차이가 없었다 (P>.05). 4. 6종류의 레진 시멘트에서 90% 이상의 대부분의 수축은 중합이 개시된 30분 내에 거의 일어났다. 결론: 자가 중합형 레진시멘트의 혼합 후 나타나는 중합 수축이 이원 중합형 레진시멘트보다 천천히 일어나지만, 혼합 120분 뒤의 중합 수축은 이원 중합형 레진 시멘트 보다 유의할 정도로 높았다. 치과용 레진시멘트의 중합 수축은 혼합한 후 30 분내에 대부분 일어난다.

A study of polymerization shrinkage of composite resins cured by various light intensities

  • Lim, Mi-Young;Hong, Chan-Ui
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2003년도 제120회 추계학술대회 제 5차 한ㆍ일 치과보존학회 공동학술대회
    • /
    • pp.613-613
    • /
    • 2003
  • The purpose of this study was to compare the effect of exponential curing method with conventional curing and two step soft start curing method on polymerization shrinkage of composite resins. Three brands of composite resins (Synergy Duo Shade, Z-250, Supreme) and three brands of light curing units (Spectrum 800, Elipar Highlight, Elipar Trillight) were used. In this study, the diameter of specimen was 5.5mm and height 1.6mm and the specimen was cured for 40 seconds. The shrinkage was measured by custom made linometer. The amount of linear polymerization shrinkage recorded in the computer every 0.5 second for 90 seconds. Each group was measured 10 times.(omitted)

  • PDF

가변 광도 중합에 따른 복합레진의 중합수축에 관한 연구 (POLYMERIZATION SHRINKAGE OF COMPOSITE RESINS CURED BY VARIABLE LIGHT INTENSITIES)

  • 임미영;조경모;홍찬의
    • Restorative Dentistry and Endodontics
    • /
    • 제32권1호
    • /
    • pp.28-36
    • /
    • 2007
  • 본 연구는 광중합형 복합레진 중합 시 기존의 중합법과 가변광도 중합형인 soft start 중합법 및 exponential 중합법 간의 중합수축효과를 비교하고자 하였다. 본 연구를 위해 3종의 복합레진 (Synergy Duo Shade, Z250, Filtek Supreme) 및 3종의 광조사기 (Spectrum 800, Elipar Highlight, Elipar Trilight)를 사용하였다. 총 중합시간은 40초로 일정하게 유지하였으며, 선형 중합수축률의 측정은 linometer를 이용하였으며, 90초간의 선형 수축률을 0.5초 간격으로 측정하였다. 재료별로 각 중합 방법별 시간에 따른 중합수축률을 one-way ANOVA test로 분석하여 최종 중합수축률에 도달하는 시간을 산출하였고, 90초 후 최종 선형 중합수축률을 two-way ANOVA test를 이용하여 재료, 광조사 방법, 재료 및 광조사 방법의 교호작용이 중합수축에 미치는 영향이 있는지를 검증하였다. 또한 90초까지의 선형 중합수축률에 대한 20초까지의 선형 중합수축률의 비를 two-way ANOVA로 비교하고, 각각의 통계치를 95% Scheffe test로 검증하였는바, 다음과 같은 결과를 얻었다 1. Supreme을 제외한 다른 군에서는 재료 및 광조사 방법에 관계없이 대부분의 중합 수축이 광조사 후 20초 이내에 이루어졌다 (p < 0.05). 2. 90초 후, 최종 중합수축률은 재료 (p = 0.000)와 광조사 방법 (p = 0.003) 모두 유의성 있는 영향을 끼쳤으나, 재료와 광조사 방법 상호간의 작용은 영향이 없었다. 3. 90초 후 최종 중합수축률은 총 광에너지가 가장 낮은 exponential 중합법에서 유의성 있게 낮았다 (p < 0.05). 4. 20초까지의 초기 수축률은 soft start와 exponential중합법 등 가변광도 중합이 conventional 중합법에 비하여 유의성 있게 낮은 수축률을 보였다 (p < 0.05). 본 실험 결과만을 토대로 볼 때, 가변광도 중합법은 초기 중합수축 속도를 감소시켜 수축응력을 감소시킨다고 볼 수 있다. 그러나 총 조사 광에너지의 차이로 인해 그 물리적 성질에 영향이 있을 수 있으므로 향후 이에 대한 더 많은 고찰이 필요할 것으로 사료된다.