• Title/Summary/Keyword: polymer electrolyte membrane for fuel cell

Search Result 406, Processing Time 0.025 seconds

Fabrication of Hydrocarbon Polymer Electrolyte Composite Membrane Incorporated with Pt Nanopartle for PEMFC and Its Characteristics (Pt 나노 입자가 도입된 연료전지용 탄화수소계 고분자 전해질 복합막의 제조 및 특성)

  • LEE, HONGKI
    • Journal of Hydrogen and New Energy
    • /
    • v.28 no.3
    • /
    • pp.246-251
    • /
    • 2017
  • To fabricate a hydrocarbon polymer electrolyte composite membrane incorporated with Pt nanoparticle, the polymer electrolyte membrane made of a sulfonated-fluorinated hydrophilic-hydrophobic block copolymer (SFBC) and sulfonated poly (ether ether ketone) (SPEEK) blend in the wight ratio of 1 : 1 was synthesized, and a simple drying process was used in order to incorporate Pt nanoparticle into the SFBC/SPEEK film by reducing platinum (II) bis (acetylacetonate), Pt $(acac)_2$. The distribution of the Pt nanoparticles was observed by transmission electron microscopy (TEM), and mechanical and thermal properties were tested by universal testing machine (UTM) and thermogravimetry analyzer (TGA). Cation conductivity, ion exchange capacity (IEC) and I-V characteristics were estimated.

Development and Operation of 5kW-Class Polymer Electrolyte Membrane Fuel Cell System (5kW급 고분자 연료전지 시스템의 개발과 운전)

  • Chun, Y.G.;Peck, D.H.;Jeon, K.S.;Kim, C.S.;Shin, D.R.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1876-1878
    • /
    • 1999
  • Developed was a 5kW-class polymer electrolyte membrane fuel cell(PEMFC) system comprised of fuel cell stack, fuel processing, thermal and water management subsystems and ancillary equipments. Several large single cells have been fabricated with different gas flow field patterns and paths, and the gas flow field pattern for the stack has been determined based on the single cell performance of thin film membrane electrode assembly (MEA). The PEMFC stack was consisted of 100 cells with an electrode area of $300cm^2$, having serpentine flow pattern. Fuel processing was developed including an autothermal methanol reformer and two preferential CO oxidation reactors. The fuel processing was combined to PEMFC operation system consisted of air compressor and thermal and water management subsystems. The PEMFC stack showed performance of 5kW under the supply of $H_2$ and air, but its performance was lowered to 3.5kW under the supply of reformed gas.

  • PDF

Synthetic Strategies for High Performance Hydrocarbon Polymer Electrolyte Membranes (PEMs) for Fuel Cells (고성능 탄화수소계 고분자 전해질막의 합성 전략)

  • Lee, So Young;Kim, Hyoung-Juhn;Nam, Sang Yong;Park, Chi Hoon
    • Membrane Journal
    • /
    • v.26 no.1
    • /
    • pp.1-13
    • /
    • 2016
  • Fuel cells are regarded as a representative energy source expected to replace fossil fuels particularly used in internal combustion engines. One of the most important components is polymer electrolyte membranes (PEMs) acting as a proton conducting barrier to prevent fuel gas crossover. Since water channels act as proton pathways through PEMs, many researchers have been focused on the 'good phase-separation of hydrophilic moiety' which ensures high water retention under low humidity enough to keep the water channel for good proton conduction. Here, we summarized the strategies which have been adopted to synthesize sulfonated PEMs having high proton conductivities even under low humidified conditions, and hope this review will be helpful to design high performance hydrocarbon PEMs.

PEMFC Operation Connected with Methanol Reformer System

  • Lee, Jung-Hyun;Park, Sang-Sun;Shul, Yong-Gun;Park, Jong-Man;Kim, Dong-Hyun;Kim, Ha-Suck;Yoo, Seung-Eul
    • Carbon letters
    • /
    • v.9 no.4
    • /
    • pp.303-307
    • /
    • 2008
  • The studies on integrated operation of fuel cell with fuel processor are very essential prior to its commercialization. In this study, Polymer Electrolyte Membrane Fuel Cell (PEMFC) was operated with a fuel processor, which is mainly composed of two parts, methanol steam reforming reaction and preferential oxidation (PROX). In fuel processor, ICI 33-5 (CuO 50%, ZnO 33%, $Al_2O_3$ 8%, BET surface area: $66\;m^2g^{-1}$) catalyst and CuO-$CeO_2$ catalyst were used for methanol steam reforming, preferential oxidation (PROX) respectively. PEMFC was operated by hydrogen fuel generated from fuel processor. The resulting gas from PROX reactor is used to operate PEMFC equipped with our prepared anode and cathode catalyst. PtRu/C catalyst gives more tolerance to CO.

PROPERTY CHANGES OF POLYMER ELECTROLYTE MEMBRANES WITH FREEZE/THAW CYCLES (동결/해동 조건에서 고분자막의 특성 변화 연구)

  • Park Gu-Gon;Lim Nam-Yun;Sohn Young-Jun;Park Jin-Soo;Lee Won-Yong;Kim Sae-Hoon;Lim Tae-Won;Kim Chang-Soo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.281-283
    • /
    • 2005
  • Water management in polymer electrolyte membrane fuel cells(PEMFCs) is one of the most challenging issues. Freeze start-up in the automotive applications is also important research topic in the PEMFC field. Transportation of proton and separation of reactant gases are main roles of polymer electrolyte membranes. It has been known that water in the membrane conducts as a vehicle for the proton transportation. At sub-zero temperature, the frozen water blocks the access of reactant gases to the active sites of electrode as well as occurs the physical destruction of fuel cell structures. In this study, property changes of electrolyte membranes in the freeze conditions $(at\;-25^{\circ}C)$ were investigated. For the various amount of water contained membranes, the property changes, especially for the proton conductivity, were observed after several times of freeze/thaw$(-25\~80^{\circ}C)$ cycle.

  • PDF

Effect of CO in Anode Fuel on the Performance of Polymer Electrolyte Membrane Fuel Cell (수소연료 중 일산화탄소의 고분자전해질 연료전지에 대한 영향)

  • Kwon, Jun-Taek;Kim, Jun-Bum
    • Journal of Hydrogen and New Energy
    • /
    • v.19 no.4
    • /
    • pp.291-298
    • /
    • 2008
  • Carbon monoxide(CO) is one of the contamination source in reformed hydrogen fuel with an influence on performance of polymer electrolyte membrane fuel cell(PEMFC). The studies of CO injection presented here give information about poisoning and recovery processes. The aim of this research is to investigate cell performance decline due to carbon monoxide impurity in hydrogen. Performance of PEM fuel cell was investigated using current vs. potential experiment, long time(10 hours) test, cyclic feeding test and electrochemical impedance spectra. The concentrations of carbon monoxide were changed up to 10 ppm. Performance degradation due to carbon monoxide contamination in anode fuel was observed at high concentration of carbon monoxide. The CO gas showed influence on the charge transfer reaction. The performance recovery was confirmed in long time test when pure hydrogen was provided for 1 hour after carbon monoxide had been supplied. The result of this study could be used as a basis of various reformation process design and fuel quality determination.

Study on optimum structure of free-breathing Polymer Electrolyte Membrane Fuel Cell (PEMFC) for robotic application (로봇용 자연급기형 연료전지의 최적구조에 관한 연구)

  • Choi, Jae-Hyuk;Park, Sang-Kyun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.2
    • /
    • pp.231-238
    • /
    • 2006
  • The performance of free-breathing polymer electrolyte membrane fuel cell (PEMFC) was studied experimentally and the effect of cathode separator structure on the cell performance was investigated. Cathode separators were used for the cell with $18cm^2$ active area. In channel type, the contact resistance is low, and the nature convection. which is strongly affected by the cross-sectional shape of cathode separator channel, is dominant in a cell performance. The maximum power density with $18cm^2$ active area is $105mW/cm^2$ using the 10mm depth and 2mm width channel. A computational analysis was optimum structure of free-breathing channel type PEMFC for robotic application.

Influence of the Catalyst Composition on Electrode Performance for Polymer Electrolyte Membrane Fuel Cells (촉매조성이 PEM용 연료전지의 전극특성에 미치는 영향)

  • 임재욱;최대규;류호진
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.9 no.3
    • /
    • pp.43-48
    • /
    • 2002
  • In this study, high performance electrode catalyst was developed in fabrication of membrane electrode assembly for PEMFCs(Polymer Electrolyte Membrane Fuel Cells). The I-V characteristics were measured to evaluate the influence of Nafion solution and Pt loading amount in the catalyst composition. The electrode characteristics were also investigated with respect to temperature change. The electrode performance was optimized at Nafion 5 wt% and 0.5 mg Pt/$\textrm{cm}^2$ content. The increase in the concentration of Nafion solution resulted in the decrease in electrode performance. At $80^{\circ}C$ of unit cell, I-V characteristics excelled those obtained at lower temperature. There was no difference in performance at low current density, but the improvement of voltage value in higher temperature could be found at high current density.

  • PDF

THE OPERATING CHARACTERISTICS IN AN AIR-BREATHING POLYMER ELECTROLYTE FUEL CELL (공기 호흡형 고분자 전해질 연료전지 제작 및 발전 특성 연구)

  • SOHN Young-Jun;PARK Gu-Gon;UM Sukkee;YIM Sung-Dae;Yang Tae-Hyun;YOON Young-Gi;LEE Won-Yong;KIM Chang-Soo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.277-280
    • /
    • 2005
  • Air-breathing polymer electrolyte membrane fuel cells (PEMFC) are highly promising particularly for small-power applications up to tens watts class. A distinctive feature of the air-breathing PEMFC is its simple system configuration in which axial fans operate for dual purposes, supplying both oxidant and coolant in a single manner. In the present study, a nominal SOW air-breathing PEMFC system is developed and investigated to determine the optimal operating strategy through parametric studies (i.e., reactant humidity, and fan-blowing flow rate). The cell voltage distributions are examined as a function of time to evaluate the system performance under various operating conditions.

  • PDF

Single Cell Performance Recovery of $SO_2$ Poisioned PEMFC using Cyclic Voltametry (순환전류 전압법을 이용한 이산화황 피독 PEMFC 단위전지의 성능 회복)

  • Lee, Soo;Jin, Seok-Hwan
    • Journal of the Korean Applied Science and Technology
    • /
    • v.28 no.4
    • /
    • pp.497-501
    • /
    • 2011
  • Polymer electrolyte membrane fuel cell (PEMFC) performance degrade when sulfur dioxide is present in the fuel hydrogen gas, this is referred as $SO_2$ poisoning. This paper reveals $SO_2$ poisoning on PEMFC cathode part by measuring electrical performance of single cell under 1 ppm and 5 ppm on $SO_2$ gas operating. The security of $SO_2$ poisoning depended on $SO_2$ concentration under the best operating conditions($65^{\circ}C$ of cell temperature and 100% of relative humidity between anode and cathode). $SO_2$ adsorption occured on the surface of catalyst layer on membrane electrode assembly (MEA), In addition, MEA poisoning by $SO_2$ was cumulative but reversible. After poisoning within 5 ppm $SO_2$ for 1hr, the electrical performance of PEMFC was found to recover up to about 93% by cyclic voltametry scan.