• Title/Summary/Keyword: polyglycolic acid

Search Result 31, Processing Time 0.029 seconds

Intrapelvic Urethral Anastomosis in a Dog with Complete Obstruction of Proximal Membranous Urethra (막성요도 근위부 완전폐쇄를 지닌 개에서 골반내 요도문합술)

  • Yoon Hun-Young;Kim Jun-Young;Han Hyun-Jung;Jang Ha-Young;Lee Bo-Ra;NamKung Hyo-Sun;Jeong Soon-Wuk
    • Journal of Veterinary Clinics
    • /
    • v.23 no.1
    • /
    • pp.61-64
    • /
    • 2006
  • A 4.65 kg 13-month-old male Pekingese dog was referred to veterinary teaching hospital of Konkuk University for evaluation of dysuria. On physical examination, severe distention of urinary bladder was found in abdominal palpation. Urinary catheter could not be guided into urinary bladder. On serum biochemistry, blood urea nitrogen (35.6 mg/dl) and creatinine (1.9 mg/dl) were increased. Obstruction part of proximal membranous urethra was founded on urethrogram. The length (13 mm) of obstruction part was callipered by cystourethrogram and urethrogram on operation. Surgical resection of obstruction part of urethra was performed without pubic osteotomy, and anastomosis was performed with 5-0 polyglycolic acid. Omentum was placed around the urethral anastomosis. On first day after surgery, appetite was good. On day 5, complete blood count and serum biochemistry showed normal range but mild urinary incontinence was showed after removing catheter. On day 7, urinalysis showed normal condition. On day 14, no leakage of surgical site was observed in excretory urogram. On day 21, no more urinary incontinence and good micturition were found. On 1 year later, the patient showed healthy condition without recurrence.

Local tissue effects of various barrier membranes in a rat subcutaneous model

  • Naenni, Nadja;Lim, Hyun-Chang;Strauss, Franz-Josef;Jung, Ronald E.;Hammerle, Christoph H.F.;Thoma, Daniel S.
    • Journal of Periodontal and Implant Science
    • /
    • v.50 no.5
    • /
    • pp.327-339
    • /
    • 2020
  • Purpose: The purpose of this study was to examine the local tissue reactions associated with 3 different poly(lactic-co-glycolic acid) (PLGA) prototype membranes and to compare them to the reactions associated with commercially available resorbable membranes in rats. Methods: Seven different membranes-3 synthetic PLGA prototypes (T1, T2, and T3) and 4 commercially available membranes (a PLGA membrane, a poly[lactic acid] membrane, a native collagen membrane, and a cross-linked collagen membrane)-were randomly inserted into 6 unconnected subcutaneous pouches in the backs of 42 rats. The animals were sacrificed at 4, 13, and 26 weeks. Descriptive histologic and histomorphometric assessments were performed to evaluate membrane degradation, visibility, tissue integration, tissue ingrowth, neovascularization, encapsulation, and inflammation. Means and standard deviations were calculated. Results: The histological analysis revealed complete integration and tissue ingrowth of PLGA prototype T1 at 26 weeks. In contrast, the T2 and T3 prototypes displayed slight to moderate integration and tissue ingrowth regardless of time point. The degradation patterns of the 3 synthetic prototypes were similar at 4 and 13 weeks, but differed at 26 weeks. T1 showed marked degradation at 26 weeks, whereas T2 and T3 displayed moderate degradation. Inflammatory cells were present in all 3 prototype membranes at all time points, and these membranes did not meaningfully differ from commercially available membranes with regard to the extent of inflammatory cell infiltration. Conclusions: The 3 PLGA prototypes, particularly T1, induced favorable tissue integration, exhibited a similar degradation rate to native collagen membranes, and elicited a similar inflammatory response to commercially available non-cross-linked resorbable membranes. The intensity of inflammation associated with degradable dental membranes appears to relate to their degradation kinetics, irrespective of their material composition.

The Mechanical Appearances and Microscopic Tissue Reactions of the Suture Materials in vivo (생체내 이식된 흡수성 봉합사들의 물리적 성질 변화와 조직 소견에 관한 연구)

  • 김남중;김명철
    • Journal of Veterinary Clinics
    • /
    • v.13 no.2
    • /
    • pp.184-194
    • /
    • 1996
  • A comparative study of three absorbable suture materials of chromic catgut, Dexon II (a polyglycolic acid suture with a polycaprolate coating system) and Coated Vicryl (a polyglactin 910 suture with a glycolide-lactide-calcium stearate coating system) was undertaken in terms of tensile strength, breaking elongation, appearances of the suture materials in the subcutaneous layer of rats and of tissue reaction in the intramuscular layer of rats. The initial tensile strength of chromic catgut and the tensile strength after 21 days were about 1.55 kg and 0.19 kg, respectively. Those of Dexon II were about 2.01 kg and 0. 20 kg, respectively. Those of Coated Vicryl were about 2.39 kg and 0.48 kg, respectively. Coated Vicryl showed the highest tensile strength among the three materials during the whole period. On the other hand, Dexon II showed the highest breaking elongation among the three materials during the first week. But the breaking elongation of Dexon II rapidly continuously decreased during the whole period. The appearances of the suture materials in the subcutaneous layer of rats showed that chromic catgut was the fastest among the three materials, whereas it formed comparatively much connective tissue. The intramuscular absorption rate and tissue reaction of Dexon II were similar to those of Coated Vicryl. The intramuscular absorption rate of these was fairly late when compared with chromic catgut. And the tissue reaction appearance of these showed the formation of a granuloma with foreign body giant cells, macrothages and epitheloid cells by the 28th day in the experimental period.

  • PDF

Sutureless Gastroduodenostomy (무봉합 위십이지장 문합술)

  • Lee, Jong-In;Kim, Jin-Young;Jeong, Jin-Ho
    • Journal of Gastric Cancer
    • /
    • v.2 no.1
    • /
    • pp.29-32
    • /
    • 2002
  • A gastroduodenostomy is the most physiological reconstruction after a distal gastrectomy. However, a gastroduodenostomy with either sutures or staples has many complications. These include bleeding, leakage and stenosis. A sutureless gastroduodenostomy with a biofragmentable anastomosis ring (BAR) in was used adenocarcinoma patients to prevent these complications from 1999. A BAR is composed of polyglycolic acid and Barium sulfate to allow for X-ray visualization. Hardy in first introduced the BAR in 1985. Since then, it has been used in an anastomosis of the colon or small bowel surgery but its use in a gastroduodenostomy is the first trial in the world. A 70 year male patient, old who received a subtotal gastrectomy (Billroth I), underwent a A sutureless gastroduodenostomy with a BAR. The gastroduodenostomy with the BAR was watertight and maintained the initial burst strength in the gastrografin X-ray study performed at the postoperative 1 week. The BAR began to fragment 3 weeks after the operation and disappeared from the digestive tract completely. The diameter of the anastomosis site was sufficient for passed foods. No other secondary changes from remained foreign bodies were found in the endoscopic examination. In a second operation to treat a primary hepatoma, there was no adhesive changes around the gastroduodenostomy site. In conclusion, a sutureless gastroduodenostomy with BAR is a safe, easy and efficient reconstructive method after a distal gastrectomy.

  • PDF

Complications of endoscopic resection in the upper gastrointestinal tract

  • Takeshi Uozumi;Seiichiro Abe;Mai Ego Makiguchi;Satoru Nonaka;Haruhisa Suzuki;Shigetaka Yoshinaga;Yutaka Saito
    • Clinical Endoscopy
    • /
    • v.56 no.4
    • /
    • pp.409-422
    • /
    • 2023
  • Endoscopic resection (ER) is widely utilized as a minimally invasive treatment for upper gastrointestinal tumors; however, complications could occur during and after the procedure. Post-ER mucosal defect leads to delayed perforation and bleeding; therefore, endoscopic closure methods (endoscopic hand-suturing, the endoloop and endoclip closure method, and over-the-scope clip method) and tissue shielding methods (polyglycolic acid sheets and fibrin glue) are developed to prevent these complications. During duodenal ER, complete closure of the mucosal defect significantly reduces delayed bleeding and should be performed. An extensive mucosal defect that comprises three-quarters of the circumference in the esophagus, gastric antrum, or cardia is a significant risk factor for post-ER stricture. Steroid therapy is considered the first-line option for the prevention of esophageal stricture, but its efficacy for gastric stricture remains unclear. Methods for the prevention and management of ER-related complications in the esophagus, stomach, and duodenum differ according to the organ; therefore, endoscopists should be familiar with ways of preventing and managing organ-specific complications.

Effect of poly(lactide-co-glycolide) (PLGA) on bone regeneration in rabbit calvaria (토끼 두개골 결손부의 골재생에 대한 poly(lactide-co-glycolide) (PLGA) 의 영향)

  • Park, Jae-Young;Hwang, Woo-Jin;Jeong, Seong-Nyum;Kim, Yun-Sang;Pi, Sung-Hee;You, Hyung-Keun;Shin, Hyung-Shik
    • Journal of Periodontal and Implant Science
    • /
    • v.39 no.2
    • /
    • pp.167-176
    • /
    • 2009
  • Purpose: The purpose of this study is to histologically and histomorphometrically evaluate the effect of PLGA on bone regeneration compared with bone graft material. Methods: The experimental study was conducted in 10 rabbits with 2 different healing periods of 2 and 4 weeks. Following surgical exposure of the calvarium, 4 circular bone defects with a diameter of 4.6mm were formed. Rabbits were divided into control group, test groups I, and II. 10 defects assigned to the test group Ⅰ were grafted with Nu-oss and other 10 defects assigned to the test group II were grafted with PLGA. The rest of the defects were in the negative control group. At 2nd and 4th week after surgery, 10 rabbits were sacrificed through intracardiac perfusion and then specimens were obtained. Histological analysis was performed following staining with trichorme and transversal sectioning of the calvarial bone. Results: A group which used PLGA showed tissue reactions characterized by severe inflammation, rather than distinctive new bone formation. Conclusions: The present experimental investigations have failed to prove any beneficial effects of PLGA. PLGA used in this study exhibited foreign body reactions and a less favorable pattern of new bone formation in comparison to control group. Conclusion: PLGA did not function as scaffold. Further investigations of many types of micro PLGA that could improve its potential in GBR procedures are needed.

PERIPHERAL NERVE REGENERATION USING POLYGLYCOLIC ACID CONDUIT AND BRAIN-DERIVED NEUROTROPHIC FACTOR GENE TRANSFECTED SCHWANN CELLS IN RAT SCIATIC NERVE (BDNF 유전자 이입 슈반세포와 PGA 도관을 이용한 백서 좌골신경 재생에 관한 연구)

  • Choi, Won-Jae;Ahn, Kang-Min;Gao, En-Feng;Shin, Young-Min;Kim, Yoon-Tae;Hwang, Soon-Jeong;Kim, Nam-Yeol;Kim, Myung-Jin;Jo, Seung-Woo;Kim, Byung-Soo;Kim, Yun-Hee;Kim, Soung-Min;Lee, Jong-Ho
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.30 no.6
    • /
    • pp.465-473
    • /
    • 2004
  • Purpose : The essential triad for nerve regeneration is nerve conduit, supporting cell and neurotrophic factor. In order to improve the peripheral nerve regeneration, we used polyglycolic acid(PGA) tube and brain-derived neurotrophic factor(BDNF) gene transfected Schwann cells in sciatic nerve defects of SD rat. Materials and methods : Nerve conduits were made with PGA sheet and outer surface was coated with poly(lactic-co-glycolic acid) for mechanical strength and control the resorption rate. The diameter of conduit was 1.8mm and the length was 17mm Schwann cells were harvested from dorsal root ganglion(DRG) of SD rat aged 1 day. Schwann cells were cultured on the PGA sheet to test the biocompatibility adhesion of Schwann cell. Human BDNF gene was obtained from cDNA library and amplified using PCR. BDNF gene was inserted into E1 deleted region of adenovirus shuttle vector, pAACCMVpARS. BDNF-adenovirus was multiplied in 293 cells and purified. The BDNF-Adenovirus was then infected to the cultured Schwann cells. Left sciatic nerve of SD rat (250g weighing) was exposed and 14mm defects were made. After bridging the defect with PGA conduit, culture medium(MEM), Schwann cells or BDNF-Adenovirus infected Schwann cells were injected into the lumen of conduit, respectively. 12 weeks after operation, gait analysis for sciatic function index, electrophysiology and histomorphometry was performed. Results : Cultured Schwann cells were well adhered to PGA sheet. Sciatic index of BDNF transfected group was $-53.66{\pm}13.43$ which was the best among three groups. The threshold of compound action potential was between 800 to $1000{\mu}A$ in experimental groups which is about 10 times higher than normal sciatic nerve. Conduction velocity and peak voltage of action potential of BDNF group was the highest among experimental groups. The myelin thickness and axonal density of BDNF group was significantly greater than the other groups. Conclusion : BDNF gene transfected Schwann cells could regenerate the sciatic nerve gap(14mm) of rat successfully.

AN EXPERIMENTAL STUDY OF TISSUE REACTION OF ABSORBABLE SUTURE MATERIALS (수종(數種)의 흡수성(吸收性) 봉합사(縫合絲)가 조직반응(組織反應)에 미치는 영향(影響)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Song, Sun-Chul;Kim, Kyung-Wook
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.13 no.4
    • /
    • pp.381-390
    • /
    • 1991
  • The purpose of this study was to select the absorbable suture material with the lowest level of foreign body reaction in the extraoral field. The absorbable sutures tested were polyglactin 910(Vicryl), polyglycolic acid(Dexon), and chromic gut. Black silk served as to control suture. Eighteen domestic rabbits served as the animal model for testing purposes. After shaving the fur, A six centimeter incision was made in the hind quarter of all eighteen animals. Each wound was then closed wit two Vicryl, two Dexon, and two chromic gut sutures. All wounds were closed in the same manner. A similar wound was made on the oppsite side and closed with black silk suture. Three rabbits were then sacrificed on postoperative day one, three, seven fourteen, twenty-one, and twenty-eight. The surgical sites were then examined histologically. 1. On days one, three, and seven all suture materials as a similar severe level of inflammatory response. On the fourteenth day the inflammatory reaction of Vicryl was minimal, chromic gut was moderate, and Dexon was severe, Black silk control groups demosnstrated the most severe levels of inflammation of all sutures tested from day fourteen to twenty-eight. 2. On the fourteenth day all absorbable suture materials demonstrated similar minimal levels of resorption. At twenty-eight days Vicryl demonstrated a greater amount of resorption than Dexon or cromic gut suture. There was no resorption noted in the black silk control groups through day twenty-eight. 3. Due to its decreased level of inflammatory response in the animal model, Vicryl might be expected to as a decreased level of response in humans. It is felt that Vicryl is preferred to Dexon or chromic gut for extraoral suturing.

  • PDF

Comparative Study of Seeding and Culture Methods to Vascular Smooth Muscle Cells on Biodegradable Scaffold

  • Kim, Dong-Ik;Park, Hee-Jung;Eo, Hyun-Seoun;Suh, Soo-Won;Hong, Ji-Hee;Lee, Min-Jae;Kim, Jong-Sung;Jang, In-Sung;Kim, Byung-Soo
    • Journal of Microbiology and Biotechnology
    • /
    • v.14 no.4
    • /
    • pp.707-714
    • /
    • 2004
  • How to improve the cell culture method on scaffolds is important in the tissue engineering fileld. In this study, we optimized seeding and culture methods to vascular smooth muscle cells (VSMCs) on biodegradable polymer scaffold. The primary culture of VSMCs obtained from canine external jugular vein was accomplished by applying the explant-derived method. The primary cultured VSMCs were seeded into scaffolds and then cultured by using various different methods; static or dynamic seeding, static or dynamic culture. The difference in proliferative response of VSMCs was analyzed with an alamar blue assay. Cell-polymer construct was examined by histochemical method and scanning electron microscopy. Mesh type scaffold ($10 \times 10 \times0.4 mm$) was made of polyglycolic acid (PGA) suture thread. The PGA mesh type scaffold was 45% in porosity, and 0.03 g in weight. The primary cultured VSMCs were confirmed with immunohistochemical staining using monoclonal anti-$\alpha$-smooth muscle actin. The density and distribution of proliferated VSMCs within the scaffold and cellular adherence on the surface of the scaffold showed better results in the static seeding condition than in the dynamic condition. Under the same condition of seeding method as the static condition, the dynamic culture condition showed enhanced proliferation rates of the VSMCs when compared to the static culture condition. In conclusion, to improve the VSMCs proliferation in vitro, static seeding is better than the dynamic condition. In the culture condition, however, culture under the dynamic status is better than the static condition. This was a pilot study to manufacture artificial vascular vessel by tissue engineering.

Microwave hybrid sintering of NTC themistor (마이크로파 하이브리드 소결법에 의한 NTC 서미스터의 제조)

  • 최영락;안진용;안주삼;백동규;최승철
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.8 no.3
    • /
    • pp.508-512
    • /
    • 1998
  • The NTC thermistors were sintered by using microwave hybrid heating method at $1100^{\circ}C$~$1300^{\circ}C$ and those electrical properties were investigated. The obtained $B_{25^{\circ}C/85^{\circ}C}$ values from temperature dependence of electrical resisitivity were around 3100~3200 K which were almost the same values as conventionally sintered ones. Compared with conventional sintering process, this process could complete whole sintering process within 20 minutes. This the processing time and energy consumption could be reduced through this rapid heating by using microwave hybrid heating.t there were showed only two peaks, glycolide melting peak and lower molecular weight melting peak without lauryl alcohol. Conversion increased slowly with the reaction time up to 50 minutes, and then gave a sudden increase above that. The reaction time to disappear in glycolide melting peak during polymerization was shortened with the increase of lauryl alcohol content. Zero-shear viscosity of polyglycolic acid decreased with the increase of free acid content in glycolide.ssional energy and bending hysteresis increased. \circled3 Surface characteristics such as friction coefficient and thickness variation of highly shrinkage fabrics became relatively roughened state. \circled4 Since stiffened and roughened characteristics of highly shrinkage fabrics, drapabilities of them were significantly lowered. Additionally thermal insulation property of high shrinkage fabric was higher than that of low shrinkage fabric due to bulky and thickened feature. From the results, it is considered that the silk fabrics with high filling shrinkage have the good bulkiness and heat keeping properties and thus they have the suitable characteristics for high quality men's and women's formal garments.

  • PDF