• Title/Summary/Keyword: pollutants loading

Search Result 150, Processing Time 0.018 seconds

Comparative Study on Loading Rate of Main Pollution Sources in Han-River (한강수계의 주요 오염원별 부하량 비교분석)

  • Kang, Sung-Hwan;Koo, Bon-Soo;Rim, Jay-Myoung
    • Journal of Industrial Technology
    • /
    • v.18
    • /
    • pp.399-404
    • /
    • 1998
  • The purposes of this research were constructed the database, based on graphing the present water pollution in Han-river due to livestock wastewater(LSW). The LSW was below 1% in respect to quantity but about 7% in respect to pollutants loading in overall Han-river. The ratio of untreated LSW is 18% to 28%, which was higher compared to the municipal and industrial wastewater. In other words, LSW was about 0.05 times of municipal wastewater in respects to quantity but 2 times in respect to the ratio of untreated wastewater. So, it was necessary for treating LSW. The pollutants loading due to livestock wastewater of the South Han-river, North Han-river and main stream were 19.7%, 19.4% and 4.0%, respectively. This was about 7% in overall Han-river. We separated the Han-river into upper, mid and down stream. As a result, we found that the livestock wastewater is the main water pollution source of upper Han-river.

  • PDF

Runoff Characteristics of Major Pollutants at the Inflow Stream to Lake Sap-Kyo in Rainy Periods (삽교호 유입하천에서 강우시 주요 오염물질의 유출 특성)

  • Park, Jae-Young;Kim, Young-Chul;Oh, Jong-Min
    • Korean Journal of Ecology and Environment
    • /
    • v.34 no.1 s.93
    • /
    • pp.62-69
    • /
    • 2001
  • This study was investigated discharge and water quality for rainy days at the inflow streams (Gog-Kyo, Mu-Han, Sap-Kyo and Nam-Won) into Lake Sap-Kyo from June to November of 1999. The eventual aim of this study was to improve the water quality of Lake Sap-Kyo. Therefore, in order to reduce inflow pollutants loading into Lake Sap-Kyo, we investigated characteristics of stormwater runoff and estimated pollutant loading for the rainy season. The results of that Sap-Kyo stream is $5.75\;m^3/sec$ flow and influences water quantity of Lake Sap-Kyo greatly during the dry weather. Gog-Kyo stream influence to quantity of Lake Sap-Kyo greatly for the rainy days. Gog-Kyo stream and Sap-Kyo stream are $12.13\;m^3/sec$ and $8.49\;m^3/sec$, respectively. The reason is that the watershed area of Gog-Kyo stream is larger than other streams. When we prepare to plan management to improve the water quality of Lake Sap-Kyo, we have to consider that runoff characteristics by land use. Among the annual total pollutants loading inflow Lake Sap-Kyo, the ratio of non-point pollutants loading estimated that SS, BOD, T-N and T-P are 62%, 43%, 41% and 27%, respectively. Therefore, in order to improve water quality of Lake Sap-Kyo, we have to reduce non-point pollutants loading.

  • PDF

Characteristics of Inflow Water Quality Variations and Pollutants Transport in Imha Reservoir during a Rainfall Event (강우시 임하호 유입수 수질변동과 오염물질의 공간적 이동 특성)

  • Lee, Heung Soo;Shin, Myung Jong;Yoon, Sung Wan;Chung, Se Woong
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.1
    • /
    • pp.97-106
    • /
    • 2013
  • The temporal and spatial variations of water quality in a stratified reservoir are fully dependent on the characteristics of inflow loading from its watershed and the transport regimes of pollutants after entering the reservoir. Because of the meteorological and hydrological conditions in Korea, the pollutants loading to reservoirs are mostly occur during rainfall events. Therefore it is important to understand the characteristics of pollutants loading from upstream rivers and their spatial propagation through the stratified reservoir during the rainfall events. The objectives of this study were to characterize the water quality variations in upstream rivers of Imha Reservoir during a rainfall event, and the transport and spatial variations of pollutants in the reservoir through extensive field monitoring and laboratory analysis. The results showed that the event mean concentration (EMC) of SS, BOD, $COD_{Mn}$, T-N, T-P, $PO_4-P$ are 8.6 ~ 362.1, 2.5 ~ 5.1, 1.5 ~ 5.1, 1.1 ~ 1.9, 8.3 ~ 57.1, 5.6 ~ 25.7 times greater than the mean concentrations of these parameters during non-rainfall period. The turbidity and SS data showed good linear correlations, but the relationships between flow and SS showed large variations because of hysteresis effect during rising and falling periods of the flood. The ratio of POC to TOC were 12.6 ~ 14.7% during the non-rainfall periods, but increased up to 28.2 ~ 41.7% during the flood event. The turbid flood flow formed underflow and interflow after entering the reservoir, and delivered a great amount of non-point pollutants such as labile and refractory organic matters and nutrients to the metalimnion layer of reservoir, which is just above the thermocline. Spatially, the lateral variations of most water quality parameters were marginal but the vertical variations were significant.

Pollutant Characteristics of Nonpoint Source Runoff in Okcheon Stream (강우시 소옥천에서의 비점오염원 유출 특성)

  • Oh, Young-Taek;Park, Je-Chul;Kim, Dong-Sup;Rhyu, Jae Keun
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.6
    • /
    • pp.657-663
    • /
    • 2004
  • The aims of this study are the characterization of runoff from nonpoint source, the analysis of the pollutant loads and an establishment of a management plan for nonpoint source of Okcheon. For this purpose the basin of the stream So-okcheon was selected to the investigated. During the period from May 29 to July 21 in 2003, the water automatic sampler system has been installed in Okkagkyo and parameters such as SS, COD, TOC, TP and TN were analyzed. The pollutants of nonpoint source seem to be washed out along the stream water in the beginning of rainfall, remain in water and cause the stream pollution. The runoffs during heavy rainfall, especially, much higher concentration of SS than those during dry period. With respect to the annual loading of pollutants of the nonpoint source, the COD was 124 ton/yr, TOC 396 ton/yr, TN 1,429 ton/yr and TP 4.2 ton/yr in the year 2002. With respect to the pollutants loading of the nonpoint source, the COD was 375 ton/yr(95% of the total COD loading of 394 ton/yr), TOC 844 ton/yr(96% of the tatal TOC loading of 876 ton/yr), TN 1,985 ton/yr(96% of the total TN loading of 2,062 ton/yr) and TP 37.1 ton/yr(92% of the total TP loading of 40.3 ton/yr) in the year 2003.

Loading Rates and Characteristics of Litter from Highway Stormwater Runoff (강우로 인해 고속도로로부터 유출되는 폐기물의 성상, 부하량 및 유출 특성)

  • Kim, Lee-Hyung;Kang, Joohyon
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.5
    • /
    • pp.415-421
    • /
    • 2004
  • Litter wastes on highway runoff are gradually being considered one of the major pollutants of concern in protecting the integrity of receiving waters for beneficial use. The California State Water Resources Control Board has identified in their 303(d) list at least 36 water bodies where trash or litter is considered a pollutant of concern. The first TMDL adopted by the Region 4 (Los Angeles area) of the California State Water Quality Control Board was for trash in the Los Angeles River. The first flush characteristic study was developed to obtain first flush water quality and litter data from representative stormwater runoff from standard highway drainage outfalls in the Los Angeles area. Total captured gross pollutants in stormwater runoff were monitored at six Southern California highway sites over two years. The gross pollutants were 90% vegetation and 10% litter. Approximately 50% of the litter was composed of biodegradable materials. The event mean concentrations show an increasing trend with antecedent dry days and a decreasing trend with total runoff volume or total rainfall. Event mean concentrations were ranged 0.0021 to 0.259g/L for wet gross pollutants and 0.0001 to 0.027g/L for wet litters. The first flush phenomenon was evaluated and the impacts of various parameters such as rainfall intensity, drainage area, peak flow rate, and antecedent dry period on litter volume and loading rates were evaluated. First flush phenomenon was generally observed for litter concentrations, but was not apparent with litter mass loading rates. Litter volume and loading rates appear to be directly related to peak storm intensity, antecedent dry days and total flow volume.

Runoff Characteristics and Non-point Source Pollution Loads from Cheongyang-Hongseong Road (청양-홍성간 도로에서의 강우 시 비점오염 유출특성 및 오염부하량 분석)

  • Lee, Chun-Won;Kang, Seon-Hong;Ahn, Tae-Woong;Yang, Joo-Kyung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.2
    • /
    • pp.265-274
    • /
    • 2011
  • Nowadays, the importance of non-point source pollution treatment is being emphasized. Especially, the easy runoff characteristic of highly concentrated pollutants in the roads makes the circumstance more complicated due to impermeability of roads. When the pollutants flow into steam it could make water quality in stream worse and it also causes a bad influence in the aquatic ecosystem because the effluents of rainfall-runoff may contain indecomposable materials like oil and heavy metals. Therefore, we tried to figure out the property of non-point source pollution when it is raining and carried out an assessment for the property of runoff for non-point source pollution and EMC (Event Mean Concentrations) of the essential pollutants during this study. As the result of the study, the EMC was BOD 5.2~21.7 mg/L, COD 7.5~35.4 mg/L, TSS 71.5~466.1 mg/L, T-N 0.682~1.789 mg/L and T-P 0.174~0.378 mg/L, respectively. The decreasing rate of non-point pollutant in Chungyang-Hongsung road indicates the maximum decrease of 80% until 5 mm of rainfall based on SS concentration; by the rainy time within 20~30 minutes, the decreasing rate of SS concentration was shown as 88.0~97.6%. Therefore it was concluded that it seems to be possibly control non-point pollutants if we install equipments to treat non-point pollutants with holding capacity of 30 min. It is supposed that the result of this study could be used for non-point pollutants treatment of roads in Chungyang-Hongsung area. We also want to systematically study and consistently prepare the efficient management of runoff from non-point source pollution and pollutant loading because the characteristics of non-point source pollution runoff changes depending on different characteristics and situations of roads and rainfall.

Effect for CSOs Storage Construction - Analysis of Storm Water Run-off Characteristics in combined sewer system (합류식 하수관거 월류수 저장 시설에 대한 효과 - 강우시 합류식 하수관거에서의 오염물질 유출특성 분석)

  • Park, Jin-Kyu;Lee, Nam-Hoon;Kim, Hae-Ryong;Lee, Woong;Lee, Chae-Young
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.6
    • /
    • pp.949-957
    • /
    • 2011
  • This aim of study was to investigate the characteristics of discharge of pollutants as well as the correlation between flow rate and water quality constituents in a combined sewer system according to the characteristics of rainfall. For the loading rates for each pollutant, the median concentrations of all pollutants except T-N was increased when a CSO took place. The loading rates of BOD, COD, SS, T-N, T-P, Cu and Zn at the CSOs were 328-1255, 25-129, 83-2009, 4-12, 14-51, 5-11 and 5-13 times higher than the DWF (Dry Whether Flow), respectively. Especially, SS loading rate was found to be highest in all pollutants. On the other hand, the range of the first flush coefficient, b for water quality constituents such as BOD, COD, SS, T-N, T-P, Cu and Zn were 0.537-0.878, 0.589-0.888, 0.516-1.062, 0.852-1.031, 0.649-0.954, 0.975-1.015 and 0.900-1.114, respectively. In term of correlation between flow rate and pollutant concentrations, SS concentration was highly correlated to flow rate. However, there was an inverse correlation between EC (Electrical Conductivity) and flow rate because of the high dilution of flow rate. In case of correlation between pollutants, there was a high correlation between SS and T-P.

Treatment Efficiency of Non-Point Source Pollutants Using Modified Filtration System (개선된 여과형 시설의 비점오염물질 처리효율 평가)

  • Kang, Hee-Man;Choi, Ji-Yon;Kim, Lee-Hyung;Bae, Woo-Keun
    • Journal of Wetlands Research
    • /
    • v.13 no.2
    • /
    • pp.161-169
    • /
    • 2011
  • The objective of this study was to evaluate the efficiency of a modified filtration system treating non-point source (NPS) pollutants. The developed Best Management Practice (BMP) technology was designed based on the geographical and climatic characteristics of the site. A lab-scale test experiment was conducted using three different hydraulic loading rates representing the first flush flow, average flow and overflow conditions during a rainfall event. Water quality analysis was performed on the water samples taken at the inflow, outflow and infiltration during the test experiment of the lab-scale BMP. Also, the water and mass balance at different hydraulic loading rates was determined. Results from the lab-scale test experiment showed that the lab-scale BMP had a high removal efficiency of 80-90% for all NPS pollutants. The overflow test condition obtained the lowest removal efficiency among the hydraulic loading rates because it gave less opportunity for the pollutants to be filtered and retained inside system. The infiltration ratio was approximately 1 % of the inflow and outflow. Increasing the infiltration ratio requires technical approach of soil amendment where the BMP is installed.

Analysis of Nonpoint Source Pollutants in Urban Stormwater Runoff (강우시 도시지역 비점오염물질의 하천 유입 산정)

  • Son, Younggyu
    • Journal of Wetlands Research
    • /
    • v.18 no.1
    • /
    • pp.94-99
    • /
    • 2016
  • Non-point source control has been issued and intensively studied for the control of water quality in streams and rivers. In this study, non-point source pollutants monitoring was conducted at the end of five small streams which were connected to a main stream in three stages including Phase I (one hr before the rainfall), Phase II (one hr after the rainfall), and Phase III (six hrs after the rainfall). For all five small streams, the concentrations and loading rates of non-point source pollutants significantly increased due to the rainfall. As a result of this, priority control streams and priority pollutants were suggested to prepare for future plans of the non-point source control.