• 제목/요약/키워드: pollutants

검색결과 4,216건 처리시간 0.023초

팔당호 상류유역의 점·비점오염원 유달부하 특성 - 남한강·경안천 수계를 대상으로 (Delivered Pollutant Loads of Point and Nonpoint Source on the Upper Watershed of Lake Paldang - Case Study of the Watershed of Namhan River and Gyeongan Stream)

  • 박지형;공동수;민경석
    • 한국물환경학회지
    • /
    • 제24권6호
    • /
    • pp.750-757
    • /
    • 2008
  • This study is conducted to characterize and evaluate delivered pollutant loads of point and nonpoint source on the upper watershed of lake paldang. The study area consists of 12 watersheds in Namhan-river and Kyungahcheon, which are approximately 80% of total area of Namhan-river and Kyungahcheon. Based on daily delivered loads from watersheds, 61% of $BOD_5$, 81% of T-N and 70% of T-P were from nonpoint sources, suggesting that delivered loads of nonpoint pollutants be crucial to water quality. On the other hand, 78% of $BOD_5$, 92% of T-N and 87% of T-P as delivered load were from nonpoint sources in an upper watershed of Namhan-river, while 48% of $BOD_5$, 70% of T-N and 57% of T-P as delivered load were from nonpoint sources in a lower watershed of Namhan-river, suggesting higher dependency of point sources than upper watershed of Namhan-river. In the characteristic of delivered loading pollutants from point and nonpoint pollution sources, delivered load of nonpoint pollutants differed significantly by seasonal flow, and as though discharged load of point pollutants were yearly uniform, delivered load of point pollutants was found to be flow-dependent because its delivery ratio was changed.

플라즈마 이온 방식의 공기정화기를 이용한 돈사내 공기오염물질 저감 효과 (Reduction Effect of Airborne Pollutants in Pig Building by Air Cleaner Operated with Plasma Ion)

  • 김윤신;김기연;조만수;고문석;고한종;정진원;오미석;윤백;김중호
    • 한국환경보건학회지
    • /
    • 제36권4호
    • /
    • pp.306-312
    • /
    • 2010
  • This field study was performed to evaluate the efficiency of a plasma ion-operated air cleaner in temporal reduction of airborne pollutants emitted from a pig housing facility. In the case of gaseous pollutants, the plasma ion air cleaner was not effective in reducing levels of ammonia, hydrogen sulfide, nitrogen dioxide, or sulfur dioxide (p>0.05). In the case of particulate pollutants, however, the air cleaner was effective in reducing levels of particulate matter ($PM_{2.5}$ and $PM_1$) by 79(${\pm}6.1$) and 78(${\pm}3.0$)%, respectively. Unlike the case of these fine particle fractions, the reduction of total suspended particles (TSP) and $PM_{10}$ following treatment was almost negligible. In the case of biological pollutants, the mean reduction efficiencies for airborne bacteria and fungi were relatively low at 22(${\pm}6.6$) and 25(${\pm}8.7$)%, respectively. Taken together, these results indicate that in terms of air pollutants released from this pig housing facility, the plasma ion air cleaner was primarily effective in reducing levels of $PM_{2.5}$ and $PM_1$.

태풍 내습 시 강수에 의한 대기오염물질 (PM10, NO2, CO, SO2)의 농도 변화 분석 (Effect of the Rainfall during Typhoon Periods on the Variation of Concentration of Ambient Air Pollutants (PM10, NO2, CO, SO2) in the Korean Peninsula)

  • 안숙희;박소연;김정윤;김백조
    • 한국대기환경학회지
    • /
    • 제30권2호
    • /
    • pp.128-138
    • /
    • 2014
  • This study has analyzed the concentration variation of four air pollutants ($PM_{10}$, $NO_2$, CO, and $SO_2$) during the typhoon periods over 10 years (2002~2011). In this study, 10 typhoon events which had rainfalls in Korean Peninsula were selected during the study period. The analysis was performed using the observation data of both the air pollutants and rainfall. In order to examine and compare the concentrations of the air pollutants between normal periods and typhoon periods, we have obtained monthly average concentrations from July to September and daily average concentrations during typhoon periods. For the period from July to September, 34% of the total rainfalls can be explained by typhoons, and the concentration of air pollutants during the typhoon period was lower than the normal period. In addition, the concentration variations of the pollutants during the typhoon period were analyzed according to two categories: differences in the concentrations between the day before and the day of the typhoon (Case 1) and between the day before and after the typhoon (Case 2). The results indicated that the reduction rate of $PM_{10}$, $NO_2$, CO, and $SO_2$ was 30.1%, 17.9%, 11.6%, 9.7% (Case 1) and 22.8%, 21.0%, 9.0%, 8.0% (Case 2), respectively. This result suggested that air quality was significantly improved during the typhoon period than after the typhoon period by the rainfall.

강우시 철로 역사에서 발생하는 비점오염물질의 유출 경향 및 특성 (Characteristics of Washed-off Pollutants from Railway Station During Storms)

  • 김이형;어성욱;이선하
    • 한국철도학회논문집
    • /
    • 제8권1호
    • /
    • pp.15-20
    • /
    • 2005
  • The ministry of Environment, Korea, are designing the TMDL(Total Maximum daily Load) program far 4 major large rivers to improve water quality from possible pollutants. It can be successfully performed as controling of nonpoint pollutants from watershed area. Railway stations are stormwater intensive land use because of high imperviousness and high pollutant mass emissions from various activities. Especially the metal pollutants from the railway station were recognized as an important pollutants because of its toxicities. In order to characterize the washed-off pollutants. the monitoring were performed on a railway station during storms. Pollutant concentrations are exponentially decreasing during the storm duration. The 95% confidence interval of pollutant concentrations in an hour storm duration ranges from 61.6 to 115.4mg/L for TSS(mean=88.50mg/L),103.8-244.1mg/L for COD(mean=174 mg/L) and 7.68-17.32mg/L for Oil & Grease(mean=12.5mg/L). The ranges of metals were 39.2-84.0 $\mu\textrm{g}$/L for total Cu(mean=61.6$\mu\textrm{g}$/L), 14.0-25.8$\mu\textrm{g}$/L for total Pb(mean=19.9$\mu\textrm{g}$/L) and 182.2-376.l $\mu\textrm{g}$/L for total Zn(mean=279.2$\mu\textrm{g}$/L). The first flush criteria for best management practices can be suggested to 50% pollutant mass emissions during 30% of the total flow.

IoT 기반 시내버스 실내공기질 노출 특성 (Exposure Characteristics of Indoor Air Pollutants in Some Local Pubic Buses)

  • 김호현
    • 한국환경보건학회지
    • /
    • 제48권1호
    • /
    • pp.44-51
    • /
    • 2022
  • Background: Air pollution is increasing together with industrialization and urbanization. In order to reduce air pollution, public transportation is recommended rather than private cars, and the number of passengers using public transportation is increasing accordingly. This study observes the concentration of indoor pollutants in city buses over time. Through this means, we intend to suggest a plan to manage the indoor air quality in city buses. Objectives: The concentration of indoor pollution in public transportation was investigated from April 2021 to January 2022. Based on this, we evaluated the exposure to indoor pollutants. Methods: Six city bus lines in an industrial city were selected for the research, and indoor pollution was measured through IoT (Internet of Things)-based sensor-type measuring devices. The concentration of pollutants was measured every minute, and statistical data were constructed based on the measurement results. Results: In all the city buses studied, the average concentration of pollutants were below the guidelines. However, some measurement results showed cases of exceeding the guidelines. As a result of the analysis by time zone, there were more cases in which pollutants exceeded the standard value during rush hour compared to at other times. A risk assessment for PM10 was performed by evaluating the excess mortality risk from exposure and the risk from inhalation exposure. Conclusions: All measured indoor pollutants in the city buses did not exceed the guidelines. Also, the risk assessment results were found to be within the level of safety. However, if a city bus is used for a long time, there is a possibility that there may be an impact on the human body due to inhalation exposure, so additional management is required.

토양여과대의 침투능 향상을 통한 비점오염물질 저감 효과에 관한 실험적 연구 (Experimental Study on Reduction Effects of Non-Point Pollutants by Improvement of Infiltration Capacity of Soil Filter Strip)

  • 우수혜;최이송;오종민
    • 생태와환경
    • /
    • 제40권2호
    • /
    • pp.264-272
    • /
    • 2007
  • 본 연구는 한강 상수원 수변지역의 실제 적용에 앞서 Bench scale의 실험을 통해 식생여과대의 단점을 보완하고 보다 효율적인 비점오염물질 저감을 위해 대조군, 모래+자갈, 여재, 자갈의 토양여과대를 조성하여 토양의 침투능력을 향상시키고 효율을 비교하고자 하였다. 실험 결과 토양여과대에서 단면 및 하부로의 침투를 증가시킨 결과 대조군과 비교하였을 때 토양여과대의 평균 표면 유출부하량과 비교하여 $8.2{\sim}40.1%$까지 감소한 것으로 나타나 토양여과대 조성을 통한 표면 유출부하량의 감소 효과가 비교적 양호하게 나타난 것으로 판단된다. 오염물질의 유입부하에 따른 총유출부하량을 통해 각각의 토양여과대에 대한 저감 효과를 비교해 본 결과, 전체적인 제거율은 SS $84.5{\sim}92.5%$, BOD $67.9{\sim}80.6%$, T-N $43.4{\sim}76.6%$), T-P $40.6{\sim}87.4%$, Cu $28.3{\sim}48.1%$, Fe $92.1{\sim}97.7%$, Pb $81.4{\sim}97.3%$인 것으로 조사되었고, 각각의 토양여과대에 대한 오염물질 저감효과를 비교해 본 결과, 여재, 모래+자갈, 자갈의 순으로 저감효과가 뛰어난 것으로 나타났다. 본 연구를 통해 기존의 식생여과대에 비해 토양층을 변화시켜 토양의 침투능을 향상시킨 토양여과대가 비점오염물질 저감에 보다 효과적이며, 하천에 가해지는 오염부하량을 감소시킬 수 있을 것으로 판단되기 때문에 차후 현장 적용 시 보다 실효성 있는 비점오염 저감대책이 될 수 있을 것으로 판단된다.

수영만으로 유입되는 육상기인 오염물질의 체류특성 모델링 (Modeling the Resident Characteristics of Land-Based Pollutant Inflow to Suyeong Bay)

  • 정우성;홍석진;이원찬;김형철;김진호;김동명
    • 해양환경안전학회지
    • /
    • 제25권1호
    • /
    • pp.45-57
    • /
    • 2019
  • 수영만 해역의 오염원 관리를 위해 유입되는 육상기인 오염물질의 체류특성을 분석하였다. 오염물질의 체류특성은 해수유동 모델과 입자추적 모델을 활용하여 분석하였다. 오염물질은 입자로 표현되며, 입자의 양과 오염물질량은 비례하도록 나타내었다. 체류특성은 각 오염원별로 부하량, 해역에서 체류하는 오염물질량, 부하량 대비 해역에 체류하는 오염물질량을 비교하여 분석하였다. 수영만 해역에 체류하고 있는 오염물질량을 오염원별 순으로 나타내면 수영하수처리장, 남부하수처리장, 수영강 등의 순이었다. 오염부하량이 적고만 내측에서 멀어질수록 해역에 체류하는 오염물질량이 적었다. 오염원 중에서는 남부하수처리장에서 유입되는 부하량이 가장 많았다. 하지만, 유입 부하량 대비 해역에 체류하는 오염물질량은 수영만으로 유입되는 오염원 중 가장 낮은 값을 보였다. 이는, 해역의 특성과 각 오염원의 지형적인 특성에 따라 오염물질이 해역에 미치는 정도가 다르다는 것을 의미한다.

Washout Removal Efficiencies of Major Air Pollutants by Precipitation

  • Kim, Dong-Sool;Lim, Deuk-Yong;Heo, Jeong-Sook
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제18권E2호
    • /
    • pp.97-106
    • /
    • 2002
  • The purpose of this study was to quantitatively estimate the washout removal efficiencies of criteria air pollutants such as SO$_2$, TSP, PM10, CO, NO$_2$, and O$_3$corresponding to the amounts and durations of precipitation. The removal patters by washout were studied with air pollutants data and the corresponding precipitation data in Seoul, Korea during the periods of 1990 to 1999. In addition, washout patterns were classified into four seasons and four time Bones, i.e., night, morning, afternoon, and evening. In this study, natures of air pollutants by sequential precipitation were also intensively studied by examining the linear relationships between removal efficiencies and the amounts and durations of precipitation for each pollutant. The results of this study showed that SO$_2$, TSP, and O$_3$were rapidly removed by initial precipitation; however, NO$_2$was slowly removed 2-hour after precipitation. Both CO and PM10 were weakly removed by washout and their removal patters showed to be irregular.

중공사모듈에 의한 수용액으로부터 유기오염물의 제거 (Removal of Organic Pollutants from Aqueous Solution by Hollow Fiber Module)

  • 유홍진
    • 한국산학기술학회논문지
    • /
    • 제4권2호
    • /
    • pp.114-119
    • /
    • 2003
  • 본 연구는 폐수로부터 몇 가지의 유기오염물(Phenol, 2-Chlorophenol, Nitrobenzene)을 비분산 용매추출법으로 동시 제거하는 실험이다. 몇 가지의 용매(MIBK, IPAc, Hexane)에 대하여 분배계수를 구하였고, 용매와 폐수사이의 향류와 병류 흐름에 의한 추출 실험을 하였다. 수용액상의 유량이 증가함에 따라 용매와의 접촉시간이 짧아져 제거율이 떨어지고, 용매의 유량이 증가함에 따라 제거율이 증가함을 알 수 있었다. 그리고 병류보다는 향류에서 유기오염물의 제거율이 증가하는 것을 알 수 있었다. 이러한 결과를 토대로 유기오염물만이 아닌 다른 중금속 오염물 둥도 처리할 수 있는 산업용 폐수처리장치의 개발을 위한 기초자료로 쓰일 수 있다.

  • PDF

과황산나트륨 산화에 의한 토양내 저휘발성 유기오염물 제거 시 온도의 영향 평가 (Temperature Effects on the Persulfate Oxidation of Low Volatile Organic Compounds in Fine Soils)

  • 정권;김도군;한대성;고석오
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제17권2호
    • /
    • pp.7-14
    • /
    • 2012
  • Batch tests were carried out to evaluate the thermal treatment of low volatile organic compounds in low-permeability soil. The chemical oxidation by sodium persulfate catalyzed by heat and Fe (II) was evaluated. Enhanced persulfate oxidation of n-decane (C-10), n-dodecane (C-12), n-tetradecane (C-14), n-hexadecane (C-16), and phenanthrene was observed with thermal catalyst, indicating increased sulfate radical production. Slight enhancement of the pollutants oxidation was observed when initial sodium persulfate concentration increased from 5 to 50 g/L. However, the removal efficiency greatly decreased as soil/water ratio increased. It indicates that mass transfer of the pollutants as well as the contact between the pollutants and sulfate radical were inhibited in the presence of solids. In addition, more pollutants can be adsorbed on soil particles and soil oxidant demand increased when soil/water ratio becomes higher. The oxidation of the pollutants was significantly improved when catalyzed by Fe(II). The sodium persulfate consumption increased at the same time because the residual Fe(II) acts as the sulfate radical scavenger.