• 제목/요약/키워드: pollutant removal

검색결과 371건 처리시간 0.019초

Mn 담지 미세기공 제올라이트를 이용한 악취오염물질인 아세트알데히드의 분해반응 (Decomposition of Odor Pollutant Acetaldehyde Using Mn Loaded Microporous Zeolites)

  • 이형원;이희진;박영권
    • 공업화학
    • /
    • 제31권1호
    • /
    • pp.57-60
    • /
    • 2020
  • An acetaldehyde, a representative food waste odor, was decomposed using a hybrid system comprised of a non-thermal plasma and catalyst at an ambient temperature under high humidity. A five wt.% Mn was impregnated on two differently structured microporous zeolites, namely Beta and ZSM-5, with a different molar ratio of SiO2/Al2O3. Under high humidity conditions, the acetaldehyde degradation was higher in zeolites with the high ratio of SiO2/Al2O3. Among studied catalysts, a five wt.% Mn/Beta (SiO2/Al2O3 = 300) showed the highest acetaldehyde removal activity owing to its high hydrophobicity and reducibility. During long term stability test using the same catalyst for 110 hours, the acetaldehyde removal activity was relatively well-maintained.

실내 포름알데히드 농도에 미치는 식물의 영향 (Plant Effects on Indoor Formaldehyde Concentration)

  • 박소영;성기준
    • 한국환경과학회지
    • /
    • 제16권2호
    • /
    • pp.197-202
    • /
    • 2007
  • Formaldehyde is a typical indoor air pollutant that has numerous adverse health problems in modern living conditions. Phytoremediation that use plants to remove contaminants from polluted media can be applied to improve indoor air quality. Two sets of experiments; 1) two rooms in newly built auditorium and 2) a bed room in 2-year-old apartment; were performed to investigate plant effects on indoor formaldehyde concentration. It was observed from the experiments that plant can help decontaminating formaldehyde at low concentration level (0.1 ppm) but the effects decreased considerably at hish concentration (1ppm). The purification effects of indoor plant also showed the periodic pattern due to its physiological activity. More purification was observed as increasing plant density in the bed room but the formaldehyde concentration returned the original concentration level in two days after removing plants. It was suggested from the results that air purification using plants is an effective means of reduction on indoor formaldehyde level, though, reduction of source is highly desirable when the concentration level is high. The results also suggest that introducing supplementary purifying aids and/or efficient ventilation could be considered due to periodic removal pattern of plant.

낙동강 상수원수의 오존처리 효과 I. 회분식 오존처리에 의한 수처리효과 (Effect of Ozone Treatment for Nakdong River Raw Water I. Efficiency of Water Treatment by Conducting Batch Test of Ozonation Experiments)

  • 조주식;임영성;이홍재;허종수
    • 한국환경과학회지
    • /
    • 제10권6호
    • /
    • pp.393-399
    • /
    • 2001
  • This study was carried out to evaluate the pollutant removal efficiencies of the advanced drinking water treatment using ozonation. for raw water, Nakdong River was used. By conducting batch ozonation test, the following results were obtained. when ozone dosage of 5mg/$\ell$was used, preozonation of raw water reduced turbidity, KMnO$_4$consumption, DOC(dissolved organic carbon), UV254 absorbance, THMFP(trihalomethane formation potential) as much as 3.9NTU, 5.5mg/$\ell$, 1.15mg/$\ell$, 0.112 and 0.065mg/$\ell$, respectively. In case of postozonation of sand filtered water, water quality was also improved with decrease in turbidity, KMnO$_4$consumption, DOC, UV254 absorbance and THMFP at the amount of 0.08NTU, 2.6mg/$\ell$, 0.88mg/$\ell$, 0.042 and 0.018mg/$\ell$, respectively. On the other hand, contents of dissolved oxygen increased at the level of 1.3mg/$\ell$ after preozonation process and 1.0mg/$\ell$ after postozonation process. The effect of ozone dosage was higher than that of its contact time for the removal of the pollutants.

  • PDF

애기장대의 종자 발아에 미치는 맥반석과 녹차의 중금속 제거 효과 (Removal Effect of Biostone and Green Tea on the Heavy Metal Toxicity during Seed Germination of Arabidopsis thaliana)

  • 박종범
    • 한국환경과학회지
    • /
    • 제12권12호
    • /
    • pp.1303-1308
    • /
    • 2003
  • This experiment was carried out to investigate the effects of heavy metals (cadmium, chromium, copper and lead) on the seed germination of Arabidopsis thaliana, and examinated the removal effects of biostone and green tea on the heavy metal toxicity. Cadmium and chromium among the four heavy metals had no effect on the seed germination even in the concentration fifty times higher than in the official standard concentration of pollutant exhaust notified by the Ministry of Environment. However, seeds were not germinated in the concentration of copper ten times higher and in the concentration of lead fifty times higher than the official standard concentration. When seeds were sown in the solutions of lead (15, 20, 25 and 30 mg/L) and copper(15 and 20 mg/L), the seed germination rates were 0% and less than 10%, respectively. However, when biostone(3 g/30 $m\ell$) was added, the seed germination rate was 100% in all the concentrations. The germination rate was 100% in distilled water and copper solution (5 mg/L). However, green tea (0.2 g/30 $m\ell$) was added, the seed germination rate was 0% in both. The results show that cadmiun and chromium had no effect on the seed germination, but lead and copper decreased the rate of seed germination of Arabidopsis thaliana, Biostone removed heavy metal toxicity, but green tea did not removed heavy metal toxicity during germination.

고속 교반을 이용한 기-액 혼합 플라즈마방전 시스템의 성능 향상 (Performance Enhancement of Gas-Liquid Mixed Plasma Discharge System using High Speed Agitation)

  • 박영식
    • 한국환경과학회지
    • /
    • 제26권6호
    • /
    • pp.711-717
    • /
    • 2017
  • Dielectric Barrier Discharge (DBD) plasma is a new technique for use in environmental pollutant degradation, which is characterized by the production of hydroxyl radicals as the primary degradation species. Due to the short lifetime of the chemically active species generated during the plasma reaction, the dissolution of the plasma gas has a significant effect on the reaction performance. The plasma reaction performance can be enhanced by combining the basic plasma reactor with a homogenizer system in which the bubbles are destroyed and turned into micro-bubbles. For this purpose, the improvement of the dissolution of plasma gas was evaluated by measuring the RNO (N-dimethyl-4-nitrosoaniline, an indicator of the generation of OH radicals). Experiments were conducted to evaluate the effects of the diameter, rotation speed, and height of the homogenizer, pore size, and number of the diffuser and the applied voltage on the plasma reaction. The results showed that the RNO removal efficiency of the plasma reactor combined with a homogenizer is two times higher than that of the conventional one. The optimum rotor size and rotation speed of the homogenizer were 15.1 mm, and 19,700 rpm, respectively. Except for the lowest pore size distribution of $10-16{\mu}m$, the pore size of the diffuser showed little effect on RNO removal.

전기분해공법을 이용한 고령화된 매립장 침출수 처리에 관한 연구 (A Study on the Aged Landfill Leachate Treatment with Electrolysis)

  • 정순형;이영세;최현국;최준호
    • 환경위생공학
    • /
    • 제20권1호
    • /
    • pp.32-39
    • /
    • 2005
  • Recently, sanitary landfill was one of the most widely used for disposal of waste in Korea. With increasing of use and public awareness of this method for disposal. there is an increased concern with respect to the pollution potential by the landfill leachate. Especially, an aged landfill leachate contained relatively large amount of the nonbiodegradable substances which could not be removed by biological treatment processes. So, this study was conducted to the removal of nonbiodegradable substances, such as Humic acid and Fulvic acid with the electrolysis. In this study, electrode materials, electrolyte concentration, electrode distance, current density, and pH value were found to have significant effect on both pollutant removal efficiency and current efficiency in electrochemical oxidation process.

강우시 인공습지를 이용한 유기물관리 (Management of Organic Matters by Constructed Treatment Wetlands during Rainfall Events)

  • 이상팔;박제철
    • 한국환경과학회지
    • /
    • 제26권3호
    • /
    • pp.401-410
    • /
    • 2017
  • This study analyzed the changes in the concentrations of organic matters in constructed treatment wetlands, coming from discharge water from a sewage treatment plant and non-point pollutant sources during rainfall events. At the beginning of a rainfall event, a massive amount of particulate organic matter flowed in, and was removed from the sedimentation basin (S1, S2); dissolved organic matter was removed after passing through stepwise treatment processes in the wetland. During dry period in the wetland, the removal efficiency rate for COD and TOC was -21 and -7%, respectively; during the rainfall event, the removal efficiency rate for COD and TOC were 47 and 43%, respectively. The highly-concentrated organic matters that flowd in at the beginning of the rainfall event was stabilized by various structures in the wetland before water discharge. Cyanobacteria blooms annually at the confluence of the So-ok stream and Daecheong Lake. Therefore, it is expected that the wetland will contribute significantly to reducing cyanobacteria and improving water quality in the area.

하수처리장 방류수의 UV 처리시 유기물질, 잔류염소 및 소독부산물 생성 거동 (Behavior of Organic Matter, Chlorine Residual and Disinfection By-Products (DBPs) Formation during UV Treatment of Wastewater Treatment Plant Effluents)

  • 한지희;손진식
    • 상하수도학회지
    • /
    • 제28권1호
    • /
    • pp.61-72
    • /
    • 2014
  • Study on effluent organic matter (EfOM) characteristic and removal efficiency is required, because EfOM is important in regard to the stability of effluents reuse, quality issues of artificial recharge and water conservation of aqueous system. UV technology is widely used in wastewater treatment. Many reports have been conducted on microbial disinfection and micro pollutant reduction with UV treatment. However, the study on EfOM with UV has limited because low/medium pressure UV lamp is not sufficient to affect refractory organics. The high intensity of pulsed UV would mineralize EfOM itself as well as change the characteristics of EfOM. Chlorine demand and DBPs formation is affected on the changed amounts and properties of EfOM. The objective of this study is to investigate the effect on EfOM, chlorine residual, and chlorinated DBPs formation with low pressure and pulsed UV treatment. The removal of organic matter through low pressure UV treatment is insignificant effect. Pulsed UV treatment effectively removes/transforms EfOM. As a result, the chlorine consumption is changed and chlorine DBPs formation is decreased. However, excessive UV treatment caused problems of increasing chlorine consumption and generating unknown by-products.

다목적 저류지의 수질개선을 위한 설계과정 및 적용에 관한 연구 - 남악 신도시 개발지를 대상으로 - (A Study on the Application and Design Procedure of Multi-Purpose Wet Detention Ponds for Improving Water Quality - Case Study of NamAk New Town Development Area -)

  • 우창호
    • 한국환경복원기술학회지
    • /
    • 제7권1호
    • /
    • pp.97-109
    • /
    • 2004
  • The disposal of stormwater is one of the major problems in urban water management. One method of reducing peak runoff rates and other detrimental impacts of stormwater is detention storage. Detention ponds as a water quality control alternatives have been investigated by a number of researchers. Recognizing multiple roles such as flood peak attenuation, pollution removal and aesthetic enhancement, the design and management of detentions ponds deserve more research. The purpose of this research is to establish design criteria wet detention ponds to improve water quality. Water quality in detention pond discharge might be improve with physical, chemical and biological alterations. Physical alteration was focused in this study. There are several methods for estimating the suspended solid control capability of wet detention ponds. Existing models of suspended solids removal are based on sedimentation and gravity settling theory. The pollutant trap efficiency of pond is a function of several interrelating factors. Detention time is the most important factor, because it determine gravity settling quantities of pollutants. Desirable modification of physical factors for improvement of water quality in wet detention ponds are volume ratio, area ratio, length to width ratio, depth, out let location, bottom soil type. In order to apply design procedure in actual site, Namak new town development area was selected.

Porosity and Liquid-phase Adsorption Characteristics of Activated Carbons Prepared From Peach Stones by $H_3PO_4$

  • Attia, Amina A.;Girgis, Badie S.;Tawfik, Nady A.F.
    • Carbon letters
    • /
    • 제6권2호
    • /
    • pp.89-95
    • /
    • 2005
  • Crushed peach stone shells were impregnated with $H_3PO_4$ of increasing concentrations (30-70%) followed by heat treatment at 773 K for 3 h. Produced carbons (ACs) were characterized by $N_2$ adsorption at 77 K using the BET-equation and the ${\alpha}$-method. High surface area microporous ACs were obtained, with enhanced internal pore volume, as function of % $H_3PO_4$. Adsorption isotherms from aqueous solution were determined for methylene blue (MB) and p-nitrophenol (PNP), as representatives for dye and phenolics pollutant molecules. Application of the Langmuir model proved the high limiting capacity towards both solute molecules, MB was uptaken in increasing amounts as function of $H_3PO_4$ concentration and generated porosity. High removal of PNP was almost the same irrespective of porosity characteristics. Competitive adsorption of $H_2O$ molecules on the hydrophilic carbon surface seems to partially reduce the available area to the PNP molecules. Application of the pseudo-second order law described well the fast adsorption (${\leq}$ 120 min) at two initial dye concentrations.

  • PDF