• Title/Summary/Keyword: pointing system

Search Result 231, Processing Time 0.023 seconds

Patent Trend Analysis of Unmanned Ground Vehicles(UGV) using Topic Modeling (토픽모델링을 이용한 무인지상차량(UGV) 특허 동향 분석)

  • Kihwan Kim;Chasoo Jun;Chiehoon Song;Jeonghwan Jeon
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.27 no.3
    • /
    • pp.395-405
    • /
    • 2024
  • This study provides a thorough examination of Unmanned Ground Vehicles(UGVs), focusing on crucial technologies and trends across major global markets. It includes an in-depth patent analysis revealing the dominant positions of the United States and the European Union in this field. Additionally, it underscores substantial advancements made by China, Japan, and Korea since 2010. Using Latent Dirichlet Allocation(LDA)-based patent text mining, the study identified key technology areas in UGV development, such as advanced control systems, navigation technologies, power supply mechanisms, and sensing and communication tools. Through linear regression analysis, the study predicted the future paths of these technology areas, offering important insights into the evolving world of UGV technology. The findings can provide strategic guidance for stakeholders in the defense, commercial, and academic sectors, pointing out the future directions in UGV advancements.

Method of Quasi-Three Dimensional Stability Analysis of the Root Pile System on Slope Reinforcement (사면보강 뿌리말뚝공법의 준3차원적 안정해석기법)

  • Kim, Hong-Taek;Gang, In-Gyu;Park, Sa-Won
    • Geotechnical Engineering
    • /
    • v.13 no.5
    • /
    • pp.101-124
    • /
    • 1997
  • The root pile system is insitu soil reinforcement technique that uses a series of reticulately installed micropiles. In terms of mechanical improvement by means of grouted reinform ming elements, the root pile system is similar to the soil nailing system. The main difference between root piles and soil nailing are due to the fact that the reinforcing bars in root piles are normally grouted under high pressure and that the alignments of the reinforcing members differ. Recently, the root pile system has been broadly used to stabilize slopes and retain excavations. The accurate design of the root pile system is, however, a very difficult tass owing to geometric variety and statical indetermination, and to the difficulty in the soilfiles interaction analysis. As a result, moat of the current design methods have been heavily dependent on the experiences and approximate approach. This paper proposes a quasi-three dimensional method of analysis for the root pile system applied to the stabilization of slopes. The proposed methods of analysis include i) a technique to estimate the change in borehole radium as a function of the grout pressure as well as a function of the time when the grout pressure is applied, ii) a technique to evaluate quasi -three dimensional limit-equilibrium stability for sliding, iii) a technique to predict the stability with respect to plastic deformation of the soil between adjacent root piles, and iv) a quasi -three dimensional finite element technique to compute stresses and dis placements of the root pile structure barred on the generalized plane strain condition and composite unit cell concept talon형 with considerations of the group effect and knot effect. By using the proposed technique to estimate the change in borehole radius as a function of the grout pressure as well as a function of the time, the estimations are made and compar ed with the Kleyner 8l Krizek's experimental test results. Also by using the proposed quasi-three dimensional analytical method, analyses have been performed with the aim of pointing out the effects of various factors on the interaction behaviors of the root pile system.

  • PDF

An Image-Guided Robotic Surgery System for Spinal Fusion

  • Chung Goo Bong;Kim Sungmin;Lee Soo Gang;Yi Byung-Ju;Kim Wheekuk;Oh Se Min;Kim Young Soo;So Byung Rok;Park Jong Il;Oh Seong Hoon
    • International Journal of Control, Automation, and Systems
    • /
    • v.4 no.1
    • /
    • pp.30-41
    • /
    • 2006
  • The goal of this work is to develop and test a robot-assisted surgery system for spinal fusion. The system is composed of a robot, a surgical planning system, and a navigation system. It plays the role of assisting surgeons for inserting a pedicle screw in the spinal fusion procedure. Compared to conventional methods for spinal fusion, the proposed surgical procedure ensures minimum invasion and better accuracy by using robot and image information. The robot plays the role of positioning and guiding needles, drills, and other surgical instruments or conducts automatic boring and screwing. Pre-operative CT images intra-operative fluoroscopic images are integrated to provide the surgeon with information for surgical planning. Some experiments employing the developed robotic surgery system are conducted. The experimental results confirm that the system is not only able to guide the surgical tools by accurately pointing and orienting the specified location, but also successfully compensate the movement of the patient due to respiration.

PERFORMANCE OF THE TRAO 13.7-M TELESCOPE WITH NEW SYSTEMS

  • Jeong, Il-Gyo;Kang, Hyunwoo;Jung, Jaehoon;Lee, Changhoon;Byun, Do-Young;Je, Do-Heung;Kang, Sung-Ju;Lee, Youngung;Lee, Chang Won
    • Journal of The Korean Astronomical Society
    • /
    • v.52 no.6
    • /
    • pp.227-233
    • /
    • 2019
  • We report the performance of the 13.7-meter Taeduk Radio Astronomy Observatory (TRAO) radio telescope. The telescope has been equipped with a new receiver, SEQUOIA-TRAO, a new backend system, FFT2G, and a new VxWorks operating system. The receiver system features a 16-pixel focal plane array using high-performance MMIC preamplifiers; it shows very low system noise levels, with system noise temperatures from 150 K to 450 K at frequencies from 86 to 115 GHz. With the new backend system, we can simultaneously obtain 32 spectra, each with a velocity coverage of 163 km s-1 and a resolution of 0.04 km s-1 at 115 GHz. The new operating system, VxWorks, has successfully handled the LMTMC-TRAO observing software. The main observing method is the on-the-fly (OTF) mapping mode; a position-switching mode is available for small-area observations. Remote observing is provided. The antenna surface has been newly adjusted using digital photogrammetry, achieving a rms surface accuracy better than 130 ㎛. The pointing uncertainty is found to be less than 5" over the entire sky. We tested the new receiver system with multi-frequency observations in OTF mode. The aperture efficiencies are 43±1%, 42±1%, 37±1%, and 33±1%, the beam efficiencies are 45±2%, 48±2%, 46±2%, and 41±2% at 86, 98, 110, and 115 GHz, respectively.

Development of An Image-Guided Robotic Surgery System for Spinal Fusion (영상 지원 척추 융합 수술 로봇 시스템의 개발)

  • Chung Goo-Bong;Lee Soo-Gang;Kim Sung-Min;Oh Se-Min;Yi Byung-Ju;Kim Young-Soo;Park Jong-Il;Oh Seong-Hoon;Kim Whee-Kuk
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.144-148
    • /
    • 2005
  • The goal of this work is to develop and test a robot-assisted surgery system for spinal fusion. The system is composed of a robot, a surgical planning system, and a navigation system. It plays the role of assisting surgeons for inserting a pedicle screw in the spinal fusion procedure. Compared to conventional methods fer spinal fusion, the proposed surgical procedure ensures minimum invasion and better accuracy by using robot and image information. The robot plays the role of positioning and guiding needles, drills, and other surgical instruments or conducts automatic boring and screwing. Pre-operative CT images and intra-operative fluoroscopic images are integrated to provide the surgeon with information for surgical planning. Several experiments employing the developed robotic surgery system are conducted. The experimental results confirmed that the system is not only able to guide the surgical tools by accurately pointing and orienting the specified location, but also successfully compensate the movement of the patient due to his/her respiration.

  • PDF

Development of Remote Control System for KNUO 16 (공주대학교 천문대 16인치 반사망원경의 원격 제어 시스템 구축)

  • Kim, Chil-Young;Chung, Jung-In;Kim, Jong-Hun;Kim, Hyouk;Jang, Bi-Ho;Kim, Hee-Soo
    • Journal of the Korean earth science society
    • /
    • v.24 no.5
    • /
    • pp.456-466
    • /
    • 2003
  • We developed a remote control system for the 16" reflecting telescope at KNUO (Kongiu National University Observatory). This system is a close loop system. The electronic control part used TCS-196 of the Korea Astronomy Observatory, the mechanical part was developed directly in this research. The pointing accuracy of this system was ${\pm}$50" in the hour angle direction, ${\pm}$40" in the declination direction after mount modeling. The tracking accuracy was about 1"/min. This pilot test result means that this system is suitable for research or education of astronomical fields.

Implementation and Performance Analysis of the Single Channel Monopulse System (단일채널 모노펄스시스템의 구현 및 성능 검증)

  • Kang, Byoung-Wook;Kwon, Hyuk-Ja;Lee, Young-Jin
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.10
    • /
    • pp.900-908
    • /
    • 2016
  • In this paper, we have studied the tracking system with a single channel monopulse receiver that has a comparative advantage of costs, size, weight, and power consumption over the general 3-channel monopulse receivers. After the single channel monopulse system was composed of an antenna, a monopulse receiver, a servo unit, a RF signal processor unit and a power supply unit, we analyzed the basic tracking performance of the tracking error angle and the pointing loss. And we proved the tracking performance to a moving target in the outdoor environment. On the Analysis of the tracking test results, the single channel monopulse system shows a equal or higher performance over the general 3-channel monopulse system and also has advantages of the system implementation. Also, it is concluded that this study is useful to apply a single channel monopulse receiver with benefits of production price and miniaturization when the monopulse tracking systems will be developed in the future.

Multiple Dimension User Motion Detection System base on Wireless Sensors (무선센서 기반 다차원 사용자 움직임 탐지 시스템)

  • Kim, Jeong-Rae;Jeong, In-Bum
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.3
    • /
    • pp.700-712
    • /
    • 2011
  • Due to recently advanced electrical devices, human can access computer network regardless of working location or time restriction. However, currently widely used mouse, joystick, and trackball input system are not easy to carry and they bound user hands exclusively within working space. Those make user inconvenient in Ubiquitous environments.. In this paper, we propose multiple dimension human motion detection system based on wireless sensor networks. It is a portable input device and provides easy installation process and unbinds user hands during input processing stages. Our implemented system is comprised of three components. One is input unit that senses user motions and transmits collected data to receiver. Second is receiver that conveys the received data to application, which runs on server computer. Third is application that performs command operations according to received data. Experiments shows that proposed system accurately detect the characteristics of user arm motions and fully support corresponding input requests.

Development of the Command and Data Handling System and Flight Software of BITSE

  • Park, Jongyeob;Baek, Ji-Hye;Jang, Bi-ho;Choi, Seonghwan;Kim, Jihun;Yang, Heesu;Kim, Jinhyun;Kim, Yeon-Han;Cho, Kyung-Suk;Swinski, Joseph-Paul A.;Nguyen, Hanson;Newmark, Jeffrey S.;Gopalswamy, Natchumuthuk
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.2
    • /
    • pp.57.4-57.4
    • /
    • 2019
  • BITSE is a project of balloon-borne experiments for a next-generation solar coronagraph developed by a collaboration with KASI and NASA. The coronagraph is built to observe the linearly polarized brightness of solar corona with a polarization camera, a filter wheel, and an aperture door. For the observation, the coronagraph is supported by the power distribution unit (PDU), a pointing system WASP (Wallops Arc-Second Pointer), telemetry & telecommand system SIP (Support Instrument Package) which are developed at NASA's Goddard Space Flight Center, Wallops Flight Facility, and Columbia Scientific Balloon Facility. The BITSE Command and Data Handling (C&DH) system used a cost-off-the-shelf electronics to process all data sent and received by the coronagraph, including the support system operation by RS232/422, USB3, Ethernet, and digital and analog signals. The flight software is developed using the core Flight System (cFS) which is a reusable software framework and set of reusable software applications which take advantage of a rich heritage of successful space mission of NASA. The flight software can process encoding and decoding data, control the subsystems, and provide observation autonomy. We developed a python-based testing framework to improve software reliability. The flight software development is one of the crucial contributions of KASI and an important milestone for the next project which is developing a solar coronagraph to be installed at International Space Station.

  • PDF

A Study On the Tracking Antenna System for a Moving Vehicle by the Embedded Linux (임베디드 리눅스를 이용한 이동체 추적 안테나 시스템에 관한 연구)

  • Kim, Jong-Kwon;Woo, Gui-Aee;Cho, Kyeum-Rae;Lee, Dae-Woo;Jang, Chul-Soon
    • Journal of Advanced Navigation Technology
    • /
    • v.8 no.1
    • /
    • pp.49-57
    • /
    • 2004
  • In This paper the embedded linux based embedded control system was used and the tracking antenna system was studied for data link and communication between moving vehicles. A microprocessor based embedded controller is equipped with SA-1110 board and this embedded controller can control the azimuth and the elevation angle of the antenna. The relative position and attitude for pointing are calculated by using the GPS position signals from the moving vehicle. To verify the performance of the designed embedded antenna system, the orbit information of the Arirang satellite(from KARI) is used.

  • PDF