• 제목/요약/키워드: point-load strength

검색결과 446건 처리시간 0.022초

원공결함을 갖는 SM45C 인장시험편의 강도해석과 음향방출에 관한 사례연구 (Case Study on the Load-Deflection and Acoustic Emission Analysis of SM45C Coupons with a Circular Hole Defect under Tensile Loading)

  • 우창기;이장규
    • 한국공작기계학회논문집
    • /
    • 제17권1호
    • /
    • pp.50-58
    • /
    • 2008
  • The SM45C metallic coupons have been tested under static tensile loading with acoustic emission (AE) as the load-deflection curve mainly. In this study, we used AE to detect the yielding of material and AE techniques was applied to rapidly estimate the mechanical characteristics of a material. First, coupons without an artificial defect were tested at different cross-head speed. For all cases in this analysis, yielding point of SM45C coupons did not appear definitely compared to mild steel, whereas coupons start to generate AE counts upon yielding. So all cases are normalized to know the possibility of accelerated life test of a material. And next, coupons with different from sizes of circular hole defects were tested at the same cross-head speed of 5 mm/min. Results were classified into 3 classes and analyzed by AE amplitude & signal strength as a function of time. Summarizing the specific conclusions, we need to additional research considering plate with width-ratio in order to estimate the fracture mechanism.

최적이론에 의하여 설계된 최소 깊이 더블티 슬래브의 휨거동 평가 (Evaluation on Flexural Behavior of Double-tee Slabs with the Least Depth from Optimization Process)

  • 유승룡;김대훈;유재천
    • 콘크리트학회논문집
    • /
    • 제11권3호
    • /
    • pp.141-152
    • /
    • 1999
  • Precast prestressed double-tee slab may be designed by the PCI Design Handbook. It is based on the bridge construction and is required for reorganization for the use of buildings in the domestic construction environments. Much enhanced sections are developed from the reforming process on the determined design factors in the previous experimental works on double tees. Pre-determined shape, reinforcement detail, and 5000 psi concrete strength can not be expected as the best solution for the domestic construction requirements because large amount of use on that systems are anticipated. Flexural tests are performed on four full-scale 12.5m proto-type models, "least depth double tee", which are resulted from the optimization process. Domestic superimposed live load regulation, domestic material properties which is available to product, building design requirements and economy in construction are considered as the main factors to establish. the first two sections are double tee section for 1.2 ton/$\m^2$ market live load with straight and one-point depressed strands and the second two are for 0.6 ton/$\m^2$ parking live load with those strand types. All of the specimens tested fully comply with the flexural strength requirements as specified by ACI 318-95. However, the research has shown that following improved considerations are needed for better result in practice. The locations and method of connection for the lowest bottom mild bar, connection method between precast and cast-in-place concrete, and dap-end reinforcement are need to be improved.

불소섭취에 따른 백서 대퇴골의 파절특성에 관한 Acoustic Emission 연구 (ACOUSTIC EMISSION CHARACTERISTIC OF THE RAT FEMUR AFTER ADMINISTRATION OF SODIUM FLUORIDE)

  • 송근배;이영은;김혜영;이상한
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제28권1호
    • /
    • pp.16-23
    • /
    • 2002
  • To understand the micro-mechanical changes and the effects of the fluoride on rat's femur after administration of sodium fluoride, the three-point bending test, acoustic emission analysis during the three-point bending test and scanning electron microscopy were performed. The obtained results were as follows: 1. Bone strength increased in the rats given 1, 5, 10 and 20 ppm of fluoride but, there were no statistical significances (p>0.05). 2. With increasing the concentration of fluoride, most AE events released rapidly just before the maximum load and smaller events were recorded than the control group's. The average of cumulative AE event counts until maximum load of the femur in 20 ppm group were significantly small with respect to the control group's (p<0.05). 3. Fracture surfaces were well coincide with the results of acoustic emission behavior. Analyses of fracture surfaces indicated that, consistent with its the highest load, rat femur in 20 ppm fluoride group displays the roughest surface.

재생 굵은골재를 사용한 철근 콘크리트 보의 거동에 관한 실험연구 (An Experimental Study on the Behavior of Reinforced Concrete Beams using Recycled Coarse Aggregate)

  • 이명규;김광서;이근호;윤건호;정상화
    • 한국건축시공학회지
    • /
    • 제4권3호
    • /
    • pp.133-141
    • /
    • 2004
  • The object of this study is to investigate experimentally the shear behavior of reinforced concrete beams using recycled coarse aggregate. At first, the specimens are manufactured for the compressive strength of 210kgf/$\textrm{cm}^2$ with recycled coarse aggregate ratio of 0%, 20%, 40%, 60%, 80%, 100%, respectively. From the results, Reinforced concrete beams using recycled coarse aggregate were made with recycled coarse aggregate ratio of 0%, 20%, 40%, 60%, 80%, with stirrups and recycled coarse aggregate ratio of 0%, 20%, 40% without stirrups. The results of crack pattern and failure mode, load-displacement curve(center point and load point) and load-steel curve(compressive, tensile, stirrup) were analysed. It is concluded from the test that the shear behavior of recycled concrete beams is determined to have similar behavior of normal concrete beams. Therefore, from this study the application of recycled concrete to concrete structures may be possible. But, for using the recycled concrete widely, it is expected that the more studies on quality control, substitution ratio and mix design related with recycled concrete are necessary.

치과용 도재의 균열전파 특성과 도재 -금속간의 응력분석 (AN EVALUATION OF THE CRACK PROPAGATION CHARACTERISTICS OF PORCELAIN AND THE BOND STRESS OF CERAMO-METAL SYSTEM)

  • 박주미;배태성;송광엽;박찬운
    • 대한치과보철학회지
    • /
    • 제32권1호
    • /
    • pp.47-76
    • /
    • 1994
  • This study was carried out to evaluate the effect of the crack propagation characteristics and bond stress of ceramo-metal system. In order to characterize the crack propagation, the static crack propagation stored in $37^{\circ}C$ distilled water of two commerical porcelains and the dynamic crack propagation under cyclic flexure load of ceramo-metal system were examined. In order to characterize the bond stress, the shear bond test, the 3-point flexure bond test, and the finite element stress analysis of ceramo-metal system were conducted. The results obtained were as follows : 1. Bulk densities and Young's moduli of opaque porcelains increased with repeated firing. 2. Maximum fracture toughness during 4 firing cycles showed at the group of 4 firing cycles in Ceramco porcelain and 2 firing cycles in Vita porcelain. 3. Shear bond strength and flexure bond strength of Ceramco-Verabond specimen were larger than those of Ceramco-Degudent G specimen (p<0.05). 4. Interfacial stresses under three point flexure bond test were concentrated at the edges of ceramometal system. 5. When a cyclic flexure load was applied, the crack growth rate of porcelain surface of ceramometal specimens was decreased as load cycles increased.

  • PDF

직교이방성 복합재료의 극저온 재료 물성치를 고려한 LNG CCS의 강도 평가에 관한 연구 (Strength Assessment of LNG CCS using Strength Analysis Method for Composite Materials)

  • 정한구;양영순
    • 대한조선학회논문집
    • /
    • 제51권2호
    • /
    • pp.114-121
    • /
    • 2014
  • Liquefied natural gas(LNG) cargo containment system(CCS) has the primary function of ensuring both adequate structural safety with respect to sloshing load which is defined as a violent behaviour of the liquid contents in CCS due to external forced motions and thermal insulation keeping natural gas below its boiling point. Among different LNG CCS types such as independent B-type and membrane ones, Mark III CCS is considered in this paper to perform its strength assessment. Mark III CCS plate is designed and constructed by stacking various non-metallic engineering materials such as plywood, triplex, reinforced PU foam that are supported by series of mastic upon inner steel hull structure. From the viewpoint of structural analysis, this plated structure is treated as a laminated composite structure showing complex structural behaviour under external load. Advanced finite element models of Mark III CCS plate is generated and used in conjunction with ultimate strength based failure criteria from laminated composite mechanics for the strength assessment. The strength assessment is performed within the initial failure state of Mark III CCS plate. Results provide failure details such as failure locations and loads. Finally obtained results are reviewed using the loads from acceptance criteria suggested by classification.

인공해수중 GFRP의 피로특성에 관한 연구 (A study on fatigue properties of GFRP in synthetic sea water)

  • 김연직;임재규
    • 대한기계학회논문집
    • /
    • 제17권6호
    • /
    • pp.1351-1360
    • /
    • 1993
  • 본 연구에서는 수적법(hand lay up : HLU)을 이용하여 단 섬유포(chopped strand mat : CSM)형태의 유리섬유를 불포화 폴리에스테르 수지에 강화시킨 복합 적층 판을 대상으로 해수중에서 굽힘·피로시험을 실시하여 피로균열 성장거동을 관찰하고 파면관찰을 통하여 GERP의 피로특성을 검토하였다.

증기발생기 전열관 감육부의 강도 및 손상평가 (Failure Assessment and Strength of Steam Generator Tubes with Wall Thinning)

  • 성기용;안석환;윤자문;남기우
    • 한국해양공학회지
    • /
    • 제21권2호
    • /
    • pp.50-59
    • /
    • 2007
  • Steam generator tubes are degraded from wear, stress corrosion cracking, rupture and fatigue and so on. Therefore, the failure assessment of steam generator tube is very important for the integrity of energy plants. In the steam generator tubes, sometimes, the local wall thinning may result from severe degradations such as erosion-corrosion damage and wear due to vibration. In this paper, the elasto-plastic analysis was performed by FE code ANSYS on steam generator tubes with wall thinning. Also, the four-point bending tests were performed on the wall thinned specimens, and then it was compared with the analysis results. We evaluated the failure mode, fracture strength and fracture behavior from the experiment and FE analysis. Also, it was possible to predict the crack initiation point by estimating true fracture ductility under multi-axial stress conditions at the center of the thinned area from FE analysis.

변형률계를 이용한 강재보의 건전도 평가 시스템 개발에 관한 연구 (A Study on Development of Structural Health Monitoring System for Steel Beams Using Strain Gauges)

  • 한현규;안형준
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제16권1호
    • /
    • pp.99-109
    • /
    • 2012
  • 이 연구에서는 변형률계를 사용하여 변위를 추정하는 이론식을 제안 및 검증하고 하중 작용점과 크기를 추정하여 강재보의 건전도 평가 시스템을 개발하고자 하였다. 실험결과 160kN(항복하중의 56%)가력시 최대처짐 점에서 변형률계를 사용하여 얻는 처짐과 변위계의 측정처짐과의 오차율이 2%이내로 나타났으며 하중작용점 및 크기의 추정도 오차율1% 이내로 나타났다. 이를 통해 변형률계로 강재보의 변위 및 하중을 계측 할 수 있으며 나아가 변위계와 하중계의 생략으로 경제적인 센서설계를 할 수 있다. Lab VIEW로 구현된 건전도 평가 프로그램은 측정된 데이터가 일정 범위(강도 한계상태, 사용성 한계상태, 항복변형률)를 넘어설 때 단계별 경고를 발생하였고 변형률계 만으로 사용성한계상태와 강도한계상태를 동시에 모니터링 할 수 있었다.

등가형상을 이용한 딤플형 금속 샌드위치 판재의 효율적 굽힘 거동 예측 (Efficient Methods of Prediction Incorporating Equivalent Models for Elasto-Plastic Bending Behavior of Metallic Sandwich Plates with Inner Dimpled Shell Structure)

  • 성대용;정창균;윤석준;양동열
    • 소성∙가공
    • /
    • 제14권8호통권80호
    • /
    • pp.718-724
    • /
    • 2005
  • An efficient finite element method has been introduced for analysis of metallic sandwich plates subject to bending moment. A full model 3-point bending FE-analysis shows that the plastic behavior of inner structures appears only at the load point. The unit structures of sandwich plates are defined to numerically calculate the bending stiffness and strength utilizing the recurrent boundary condition for pure bending analysis. The equivalent models with the same bending stiffness and strength of full models are then designed analytically. It is demonstrated that the results of both models are almost the same and the FE-analysis method incorporating the equivalent models can reduce the computation time effectively. The dominant collapse modes are face buckling and face yielding. Since the inner dimpled structures prevent face buckling, sandwich plates with inner dimpled shell structure can absorb more energy than other types of sandwich plates during the bending behavior.