• Title/Summary/Keyword: point index

Search Result 1,723, Processing Time 0.035 seconds

Development and Verification of the Fog Stability Index for Incheon International Airport based on the Measured Fog Characteristics (인천국제공항의 안개 특성에 따른 안개 안정 지수 FSI(Fog Stability Index) 개발 및 검증)

  • Song, Yunyoung;Yum, Seong Soo
    • Atmosphere
    • /
    • v.23 no.4
    • /
    • pp.443-452
    • /
    • 2013
  • The original Fog Stability Index (FSI) is formulated as FSI=$2(T-T_d)+2(T-T_{850})+WS_{850}$, where $T-T_d$ is dew point deficit (temperature-dew point temperature), $T-T_{850}$ is atmospheric stability measure (temperature-temperature at 850 hPa altitude) and $WS_{850}$ is wind speed at 850 hPa altitude. As a way to improve fog prediction at Incheon International Airport (IIA), we develop the modified FSI for IIA, using the meteorological data at IIA for two years from June 2011 to May 2013, the first one year for development and the second one year for validation. The relative contribution of the three parameters of the modified FSI is 9: 1: 0, indicating that $WS_{850}$ is found to be a non-contributing factor for fog formation at IIA. The critical success index (CSI) of the modified FSI is 0.68. Further development is made to consider the fact that fogs at IIA are highly influenced by advection of moisture from the Yellow Sea. One added parameter after statistical evaluation of the several candidate parameters is the dew point deficit at a buoy over the Yellow Sea. The relative contribution of the four parameters (including the new one) of the newly developed FSI is 10: 2: 0.5: 6.4. The CSI of the new FSI is 0.50. Since the developmental period of one year is too short, the FSI should be refined more as the data are accumulated more.

Correlation Analysis of Edema Sensation in Postpartum Mothers, Inbody Edema Index, and Weight Change before and after Childbirth (산욕기 산모의 부종감각과 Inbody 부종지수, 출산 전후 체중변화의 상관성 분석)

  • Kim, Young-Eun;Kim, An-Na;Seo, Su-Min;Kim, Pyung-Wha;Son, Mi-Ju;Lee, Eun-Hee;Jang, Hyun-Chul
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.35 no.1
    • /
    • pp.1-11
    • /
    • 2022
  • Objectives: Management of the postpartum period is important for the health of mothers, and postpartum edema is one of the management targets. In this study, the relationship between the value measured by the device and the postpartum edema sensation was examined to explain the subjective sensation of the mother as an objective value. Methods: Data from 54 cases provided by 24 mothers within 6 weeks postpartum were used in the study. The degree of postpartum edema sensation was measured using a visual analog scale (VAS), and the effect of VAS changes on the body edema index and weight change before and after childbirth was estimated through linear regression analysis. Results: As a result of the regression analysis, when the edema sensation of the mothers VAS increased by 1 point, the Inbody edema index increased by 0.002 points (p=0.000, R2=0.272), and when the VAS increased by 1 point, the weight gain increased by 0.99 kg compared to before pregnancy (p=0.000, R2=0.243), and when VAS increased by 1 point, weight loss decreased by 0.56 kg compared to just before childbirth (p=0.004, R2=0.136). Conclusions: The results of this study, in which the edema sensation of postpartum mothers was statistically significantly related to the edema index and weight change before and after childbirth, showed that the edema sensation complained by the mother could be used as an evaluation index for postpartum edema management in the future.

An improved response surface method for reliability analysis of structures

  • Basaga, Hasan Basri;Bayraktar, Alemdar;Kaymaz, Irfan
    • Structural Engineering and Mechanics
    • /
    • v.42 no.2
    • /
    • pp.175-189
    • /
    • 2012
  • This paper presents an algorithm for structural reliability with the response surface method. For this aim, an approach with three stages is proposed named as improved response surface method. In the algorithm, firstly, a quadratic approximate function is formed and design point is determined with First Order Reliability Method. Secondly, a point close to the exact limit state function is searched using the design point. Lastly, vector projected method is used to generate the sample points and Second Order Reliability Method is performed to obtain reliability index and probability of failure. Five numerical examples are selected to illustrate the proposed algorithm. The limit state functions of three examples (cantilever beam, highly nonlinear limit state function and dynamic response of an oscillator) are defined explicitly and the others (frame and truss structures) are defined implicitly. ANSYS finite element program is utilized to obtain the response of the structures which are needed in the reliability analysis of implicit limit state functions. The results (reliability index, probability of failure and limit state function evaluations) obtained from the improved response surface are compared with those of Monte Carlo Simulation, First Order Reliability Method, Second Order Reliability Method and Classical Response Surface Method. According to the results, proposed algorithm gives better results for both reliability index and limit state function evaluations.

A Study on Design of Barrel Cam for Automatic Bulb Production Machine (전구 자동화 생산기계용 바렐 캠의 형상설계에 관한 연구)

  • Kim, Jong-Su;Yun, Ho-Eop
    • 연구논문집
    • /
    • s.33
    • /
    • pp.89-97
    • /
    • 2003
  • A barrel cam is used as a very important part of an index drive unit. The index drive unit must have an intermittent-rotational motion. The barrel typed cam and roller gear mechanism has the advantages of high reliability to perform a prescribed motion of a follower. This paper proposes a new method for the shape design of the barrel cam and also a CAD program is developed by using the proposed method. As defined in this paper, the relative velocity method for the shape design calculates the relative velocity of the follower versus cam at a center of roller, and then detemines a contact point by using the geometric relationships and the kinematic constraints, where the direction of the relative velocity must be parallel to a common tangential line at the contact point of two independent bodies, i.e. the cam and the follower. Then, the shape of the cam is defined by the coordinate transformation of the trace of the contact points. This paper presents shape design of the barrel cam in order to prove the accuracy of the proposed methods

  • PDF

B-spline Curve Approximation Based on Adaptive Selection of Dominant Points (특징점들의 적응적 선택에 근거한 B-spline 곡선근사)

  • Lee J.H.;Park H.J.
    • Korean Journal of Computational Design and Engineering
    • /
    • v.11 no.1
    • /
    • pp.1-10
    • /
    • 2006
  • This paper addresses B-spline curve approximation of a set of ordered points to a specified toterance. The important issue in this problem is to reduce the number of control points while keeping the desired accuracy in the resulting B-spline curve. In this paper we propose a new method for error-bounded B-spline curve approximation based on adaptive selection of dominant points. The method first selects from the given points initial dominant points that govern the overall shape of the point set. It then computes a knot vector using the dominant points and performs B-spline curve fitting to all the given points. If the fitted B-spline curve cannot approximate the points within the tolerance, the method selects more points as dominant points and repeats the curve fitting process. The knots are determined in each step by averaging the parameters of the dominant points. The resulting curve is a piecewise B-spline curve of order (degree+1) p with $C^{(p-2)}$ continuity at each knot. The shape index of a point set is introduced to facilitate the dominant point selection during the iterative curve fitting process. Compared with previous methods for error-bounded B-spline curve approximation, the proposed method requires much less control points to approximate the given point set with the desired shape fidelity. Some experimental results demonstrate its usefulness and quality.

Study on critical point of ZnCdSe by using Fourier analysis (Fourier 변환을 이용한 ZnCdSe 전이점 연구)

  • Yoon, J.J.;Ghong, T.H.;Kim, Y.D.
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.6
    • /
    • pp.458-462
    • /
    • 2007
  • Spectroscopic ellipsometry is an excellent technique for determining dielectric function. To obtain critical point energy, standard analytic critical point expression is used conventionally for second derivatives of dielectric function which might increase high frequency noise than signal. However, reciprocal-space analysis offers several advantages for determining critical point parameters in optical and other spectra, for example the separation of baseline, information, and high frequency noise in low-, medium-, high-index Fourier coefficient, respectively. We used reciprocal Fourier analysis for removing noise and determining critical point of ZnCdSe alloy.

The Relationship Between the Food Habit and the Health Responses to the Todai Health Index (식습관(食習慣)과 건강상태(健康狀態)와의 관계성(關係性)에 관(關)한 연구(硏究))

  • Lim, Hyeon-Sook
    • Journal of Nutrition and Health
    • /
    • v.14 no.1
    • /
    • pp.9-15
    • /
    • 1981
  • This study was undertaken to investigate the relationship between the food habit and the health status. For this Purpose, 709 junior and senior high school teachers were studied by the questionnaire sheets; one was for the food habit and the other was for health complaints. (the standarized questionnaire designated Todai Health Index.) The results obtained were as follows, 1) Mean score of the food habit was 10.99 in males and 12.17 in females. The balanced dietary intake was associated with the ideal body weight. 2) In males and females with low food habit score than in those with high food habit score, THI point in sufferings, digestive organs, straight-forwardness, depression and life irregularity were higher. In males with low food habit score, THI point in nervousness was higher. In females with low food habit score, THI point in respiratory organs was higher. On the contrary the male subjects with high food habit score showed higher THI point in vanity and the female subjects with high feed habit score shewed higher THI point in vanity and nervousness. 3) Persons living alone showed a high tendency to eating away from home and to having low score of food habit. 4) Persons with low food habit score showed a high tendency to eating instant foods and considered themselves having poor health status.

  • PDF

A Simple Control Strategy for Balancing the DC-link Voltage of Neutral-Point-Clamped Inverters at low modulation index (Neutral-Point-Clamped 인버터의 저 변조지수에서 DC 링크 전압 균형을 위한 간단한 컨트롤 기법)

  • Ma C.S.;Kim T.J.;Kang D.W.;Hyun D.S.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.560-564
    • /
    • 2003
  • This paper proposes a simple control strategy based on the discontinuous PWM(DPWM) to balance the DC-link voltage of three-level Neutral-Point-Clamped(WPC) inverters at low modulation index. New DPWM methods in multi-level inverter are also introduced. The proposed DPWM method changes the path and duration to flow the neutral point current out of or into neutral point of the DC-link and it makes the overall fluctuation of the DC-link voltage zero during a sampling time of reference voltage vector. Therefore, the voltage of the DC-link can be balanced fairly well and also the voltage ripple of the DC-link is reduced significantly. Moreover, comparing with conventional methods, the proposed strategy is very simple. The validity of the proposed DPWM method is verified by experiment

  • PDF

An Efficient Median Filter Algorithm for Floating-point Images (부동소수점 형식 이미지를 위한 효율적인 중간값 필터 알고리즘)

  • Kim, Jin Wook
    • Journal of IKEEE
    • /
    • v.26 no.2
    • /
    • pp.240-248
    • /
    • 2022
  • Floating-point images that express pixel information as real numbers are used in HDR images. There have been various researches on efficient median filter algorithms, but most of them are applicable to 8-bit depth images and there are only a few number of algorithms applicable to floating-point images, including Gil and Werman's algorithm. In this paper, we propose a median filter algorithm that works efficiently on floating-point images by improving Kim's algorithm, which improved Gil and Werman's algorithm. Experimental results show that the execution time is improved by about 10% compared to the Kim's algorithm by reducing the redundant work for the repetitively used binary search tree and applying the inverted index.

Relationship between Interdental Papilla Existence & Distance from Interdental Alveolar Crest to Contact Point in the Posterior Dentition of Korean adults (한국인 구치열에서 치간유두 존재와 치아접촉점과 치간골 거리와의 관계)

  • Kim, Hyun-Chul;Jeon, Yong-Seon;Chang, Moon-Taek;Kim, Hyung-Seop;Park, Jung-Mi
    • Journal of Periodontal and Implant Science
    • /
    • v.31 no.3
    • /
    • pp.625-631
    • /
    • 2001
  • The anatomic structure around interproximal area plays an important role not only in the natural teeth, but also in the implant. The loss of papilla can lead to cosmetic deformity, phonetic problem, food impaction on the anterior dentition, and masticatory problem, food impaction and proximal caries on the posterior dentition. The purpose of this study was to evaluate the relationship between interdental papilla existence and distance from contact point to alveolar crest in Korean posteior dentition. 45 Korean adult patients(31males, 14 females) participated in this study. Measurements were carreid out total 126 interproximal areas, 18 first premolar, 31 second premolar, 40 first molar, and 37 second molar areas. Papilla index was recorded as suggested by Jemt. Distance between contact point and alveolar crest measrued by Florida $probe^{R}$, after flap elevation. Each distance was measured 10 times by every 0.1mm unit. The results showed that the mean Papilla index 1.37 and mean distance between contact point and alveolar crest was 7.44mm. The correlation between the Papilla index and distance was high negative correlation(Pearson correlation=-0.47), and it was statistically significant(P=0.000) When the distance between contact point and alveolar crest was 5mm, the loss of papilla was appeared almost in half cases. When the distance was 6mm, the papilla loss was present 95%, when 7mm, the papilla loss was 100%.

  • PDF