• 제목/요약/키워드: point defects

검색결과 497건 처리시간 0.026초

Defect-related yellowish emission of un doped ZnO/p-GaN:Mg heterojunction light emitting diode

  • Han, W.S.;Kim, Y.Y.;Ahn, C.H.;Cho, H.K.;Kim, H.S.;Lee, J.H.
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.327-327
    • /
    • 2009
  • ZnO with a large band gap (~3.37 eV) and exciton binding energy (~60 meV), is suitable for optoelectronic applications such as ultraviolet (UV) light emitting diodes (LEDs) and detectors. However, the ZnO-based p-n homojunction is not readily available because it is difficult to fabricate reproducible p-type ZnO with high hall concentration and mobility. In order to solve this problem, there have been numerous attempts to develop p-n heterojunction LEDs with ZnO as the n-type layer. The n-ZnO/p-GaN heterostructure is a good candidate for ZnO-based heterojunction LEDs because of their similar physical properties and the reproducible availability of p-type GaN. Especially, the reduced lattice mismatch (~1.8 %) and similar crystal structure result in the advantage of acquiring high performance LED devices. In particular, a number of ZnO films show UV band-edge emission with visible deep-level emission, which is originated from point defects such as oxygen vacancy, oxygen interstitial, zinc interstitial[1]. Thus, defect-related peak positions can be controlled by variation of growth or annealing conditions. In this work, the undoped ZnO film was grown on the p-GaN:Mg film using RF magnetron sputtering method. The undoped ZnO/p-GaN:Mg heterojunctions were annealed in a horizontal tube furnace. The annealing process was performed at $800^{\circ}C$ during 30 to 90 min in air ambient to observe the variation of the defect states in the ZnO film. Photoluminescence measurements were performed in order to confirm the deep-level position of the ZnO film. As a result, the deep-level emission showed orange-red color in the as-deposited film, while the defect-related peak positions of annealed films were shifted to greenish side as increasing annealing time. Furthermore, the electrical resistivity of the ZnO film was decreased after annealing process. The I-V characteristic of the LEDs showed nonlinear and rectifying behavior. The room-temperature electroluminescence (EL) was observed under forward bias. The EL showed a weak white and strong yellowish emission colors (~575 nm) in the undoped ZnO/p-GaN:Mg heterojunctions before and after annealing process, respectively.

  • PDF

중수로 핵연료채널과 인접관의 간격측정을 위한 원거리장 와전류검사 기술개발 (Remote field Eddy Current Technique Development for Gap Measurement of Neighboring Tubes of Nuclear Fuel Channel in Pressurized Heavy Water Reactor)

  • 정현규;이동훈;이윤상;허형;정용무
    • 비파괴검사학회지
    • /
    • 제24권2호
    • /
    • pp.164-170
    • /
    • 2004
  • 중수로 내부구조물 중 칼란드리아관(CT)와 액체주입노즐관(LIN)은 서로 수평으로 90도 교차되게 배열되어 있으며 원자로 내의 열, 방사선, 하중에 의해 creep 현상이 발생되어 처짐이 일어난다. 칼란드리아관은 액체주입노즐관과 동일 재료이나 운전 온도와 방사선 조사량으로 인해 액체주입노즐관에 비해 상당히 열악한 조건에 노출되어 있으므로 처짐이 심각할 것으로 예상된다. 만약 두 관의 접촉이 발생되면 원전 안전성에 영향을 미칠 것이므로 인접관에 대한 접촉여부 점검은 중수로 안전현안 중 하나이다. 이러한 접촉여부를 확인하기 위하여 핵연료채널 내부로 탐촉자를 삽입하여 인접관과의 교차점에서 간격을 직접측정하기 위한 방법으로 원거리장 와전류검사 (RFECT) 기술을 적용하였다. 핵연료채널 인접관인 액체주입노즐관 신호 취득시 발생 가능한 잡음 신호(두께변화, Lift-off, 수축)에 대해 체적적분법에 의한 모델링으로 조사하였고, 신호와 잡음과의 분리 가능한 조건을 확인하였다. 원거리장 와전류검사 적정 조건은 민감도와 투과력 그리고 잡음신호 등을 동시에 고려하여 주파수 1kHz와 코일간격 200m로서 결정하였다. 원거리장 와전류검사 실험 결과 칼란드리아관과 액체주입노즐관 사이의 간격 변화에 대한 신호 특성을 전압평면을 이용하여 상관관계를 도출하였다.

거골 박리성 골 연골염의 관절경적 치료 (Arthroscopic Treatment of Osteochondritis Dissecans of the Talus)

  • 최종혁;천용민
    • 대한관절경학회지
    • /
    • 제6권2호
    • /
    • pp.161-170
    • /
    • 2002
  • 목적 : 관절경을 이용한 거골 박리성 골연골염의 단순 절제술 후 그 결과를 알아보고 이차 관절경을 통하여 결손 부위의 육안 및 조직학적 변화를 알아보고자 하였다. 대상 및 방법 : 관절경으로 유리체 및 괴사 골 조직을 제거한후 출혈되는 기저부를 남겨두고 치료한 22예를 대상으로 하였으며, 임상적 및 기능적 평가를 하여 수술의 유용성을 알아보았다. 7예에서 이차 관절경을 술 후 3개월에서 8년 사이에 시행하여 병변 부위의 관찰 및 타 부위의 이차적인 병변을 관찰하였으며, 생검을 시행하여 결손부 재생 조직에 대한 조직학적 검사를 시행하였다. 추시 관찰은 평균 42개월(14개월$\~$8년) 이었다. 결과 : 최종 추시 관찰에서 Ankle-hindfoot(100점) 점수는 술 전 67점에서 술 후 82점으로 의미있는 호전을 보였고(p<0.003), 주관적 및 기능적 평가(100점)상 술 후 평균 82점으로 만족할 만한 결과를 얻었다. 이차 관절경상 결손부는 섬유성 조직으로 채워지는 양상을 보였으며, 시간의 경과에 따라 섬유성 조직보다는 섬유 연골 조직이 증가되는 소견을 보였다. 술 후 특이한 이차적인 병변의 발생은 관찰되지 않았다. 결론 : 관절경을 이용한 거골 박리성 골연골염에 대한 단순 절제술은 결손 부위를 남겨 놓고 치료하는 방법이나 이차적 병변의 발생없이 결손부가 채워지는 소견을 보여 유용한 방법으로 사료되었다.

  • PDF

현행 즉결심판제도의 개선방안 연구 (A Study of the Summary Trial System's Reform Measures)

  • 곽영길
    • 시큐리티연구
    • /
    • 제13호
    • /
    • pp.47-70
    • /
    • 2007
  • 형사소송절차는 ‘신속한 재판 및 소송경제’ 와 ‘실체진실발견 및 인권보장’을 주요한 목적 이념으로 하고 있으며, 이들 두 가지 가치는 서로 갈등관계에 있다. 즉결심판제도는 판사가 범증이 명백하고 죄질이 경미한 범죄를 신속${\cdot}$적정한 절차를 통해 심판하는 특별간이절차로서 심판절차를 신속하게 종결하여 즉결피의자나 피고인을 형사절차로부터 조속히 해방시키는 데 주된 목적이 있다. 그러나 이러한 취지를 지나치게 강조하다보면 사건의 충분한 심리나 피의자${\cdot}$고인의 인권보장에 소홀해지기 쉬운 것도 사실이다. 따라서 즉결심판제도는 이러한 부작용을 방지할 수 있는 제도적 장치가 반드시 요구된다. 바로 이러한 시각에서 현행 즉결심판제도를 면밀히 검토할 필요가 있는 것이다. 본 연구의 주된 목적은 입법론적 관전에서 현행 제도의 문제점을 분석하여 제도자체의 폐지를 포함한 다양한 개선방안을 강구하는데 있다. 결론적으로 말하자면 즉결심판제도는 단점보다는 장점이 훨씬 많은 제도이므로 현행대로 유지하되, 즉결피의자${\cdot}$피고인 이의제도를 도입하거나 구류형을 폐지하는 등 충분한 제도적 보완이 뒤따라야 한다고 본다.

  • PDF

SG Tube 축방향 노치 균열의 정량적 EC 신호평가 (Quantitative EC Signal Analysis on the Axial Notch Cracks of the SG Tubes)

  • 민경만;박중암;신기석;김인철
    • 비파괴검사학회지
    • /
    • 제29권4호
    • /
    • pp.374-382
    • /
    • 2009
  • 원자력발전소의 1차측 및 2차측 냉각계의 장벽 역할을 하는 핵심 설비중 하나인 증기발생기(steam generator, SG) 전열관은 공공의 사회적 안전성과 효율적인 발전 용량을 유지하기 위해 구조적 건전성을 유지하여야 한다. 또한 결함을 함유하고 있는 전열관은 해당결함을 조기에 검출, 정량적으로 결함을 평가하여 필요한 경우에는 보수조치를 수행하여야 한다. 이러한 결함의 검출 및 정량화를 위해서 검사관련 고시 및 강화된 SG 관리프로그램(SGMP)에 근거하여 와전류탐상검사법(eddy current testing, ECT)을 적용, 검사를 수행하고 있다. SG 전열관에서 검출되고 있는 결함중 응력부식균열(stress corrosion cracking, SCC)은 미세한 경우 결함의 검출이 어려울 뿐 아니라 생성된 결함의 성장속도가 빠르기 때문에 SG 전열관의 건전성을 위협하는 주요결함 기구중 하나로 분류하고 있다. 본 논문에서는 다양한 결함 깊이 및 길이별로 방전가공(electric discharge machining, EDM)된 축방향 ODSCC에 대해 pancake, +point 및 shielded pancake 코일 등이 탑재된 3 coil형태의 +PT MRPC(motorized rotating pancake coils)를 적용하여 결함의 검출가능 여부 및 크기 측정을 위한 검사를 수행하였으며 본 실험결과를 통해 SG 전열관의 건전성 및 원전 운전의 안전성을 진단하는 공학적 평가 자료로써의 활용 가능성 뿐 아니라 와전류탐상검사의 신뢰도 향상을 도모하고자 하였다.

산해리도가 다른 무기산에 의한 토양 입자 표면 특성 (Characteristics of composition and surface morphology of soil particles influenced by inorganic acids with different acidity)

  • 이동성;이교석;신지수;이재봉;주리나;이명연;민세원;정덕영
    • 농업과학연구
    • /
    • 제42권3호
    • /
    • pp.191-199
    • /
    • 2015
  • We conducted this research to observe the changes of surface morphology and composition of clay minerals influenced by various concentrations of fluoric acid. Hydrofluoric acid (HA), a solution of hydrogen fluoride (HF) in water, is a colourless solution that is highly corrosive, capable of dissolving many materials, especially oxides. To do this, we treated several concentrations of HA on the ground soil samples collected from the agricultural experimental station located at Chungnam National University to observe the influence of fluoric acid on the changes of surface structures and elemental composition of clay particles. Generally, microscopic examination showed that the HA can not only attack an edge of clay particles but also start at any point where structural defects and weaknesses predisposed sites to acid. The orderly flake arrangement of clay minerals may reflect certain crystal symmetry elements. The ESEM-EDS results of element composition of clay particles influenced by HA indicated the changes of structures of clay minerals. It is also clear from the formation of etch figures and element composition of clay particles that the product layer at least partially dissolved or disintegrated in the presence of acid. Conclusively, the clay structures can be strongly influenced by concentrations of HA, resulting in changes of physical and chemical properties that can determine the behavior of solute transport as well as mobility of ions in soils.

나노 스케일 확산 공정 모사를 위한 동력학적 몬테칼로 소개 (An Introduction to Kinetic Monte Carlo Methods for Nano-scale Diffusion Process Modeling)

  • 황치옥;서지현;권오섭;김기동;원태영
    • 대한전자공학회논문지SD
    • /
    • 제41권6호
    • /
    • pp.25-31
    • /
    • 2004
  • 본 논문에서는 나노 스케일 확산 공정 모사를 위한 방법으로 동력학적 몬테칼로(kinetic Monte Carlo)를 소개하고자 한다. 먼저 동력학적 몬테칼로의 이론과 배경을 살펴보고 실제적인 이해를 돕기 위하여 실리콘 기판에 이온(전자) 주입 후 열처리과정에서 일어나는 점결함의 확산을 동력학적 몬테칼로를 이용하여 모사하는 간단한 예를 보여주고 있다. 동력학적 몬테칼로는 몬테칼로의 일종이지만 기존의 몬테칼로에서 구현하지 못하였던 물리적인 시간을 포아송 확률 과정을 통하여 구현하였다. 동력학적 몬테칼로 확산 공정 모사에서는 연속 확산 미분 방정식의 해를 구하는 기존의 유한 요소 수치 해석적 방법과 달리원자 상호간 혹은 원자와 결함 또는 결함들 간의 화학적 반응과 입자들의 확산 과정을 포아송 확률 과정에 따라 일어나는 화학적 반응, 입자들의 확산 사건의 연속으로 본다. 사건마다 고유의 사건 발생 확률을 갖고 이 사건 발생 확률에 따라 일어나는 확률적 사건의 연속적 발생으로 실제의 반도체 확산 공정을 시간에 따라 직접적으로 모사할 수 있다. 입자들 간의 화학적 반응 사건 확률과 입자들의 확산 공정에 필요한 확률적 인자들은 분자 동역학, 양자 역학적 계산, 흑은 실험으로 얻어진다.

수부 재건을 위한 동맥화 정맥 피판의 확장된 적응증과 임상적 유용성의 재조명 (Revisit of the Extended Indications and Clinical Utilities of Arterialized Venous Flap for Hand Reconstruction)

  • 우상현;김경철;이기준;하성한;유선오;김주성
    • Archives of Reconstructive Microsurgery
    • /
    • 제14권1호
    • /
    • pp.1-13
    • /
    • 2005
  • Purpose: The purpose of this study is to present extended indications for the use of arterialized venous flaps in reconstructing soft tissue, tendon, nerve, blood vessel, and composite tissue defects of the hand of various sizes based on researches and clinical experiences of the authors. Moreover, procedures to achieve complete flap survival and postoperative results are presented. Materials & methods: This study is based on 154 cases of arterialized venous flaps performed to reconstruct the hand during the past 11 years. The most common cause of injury was industrial accidents with 125 cases. One hundred thirty patients or 84% of the cases had emergency operation within 2 weeks of the injury. The flaps were categorized depending on the size of the flap. Flaps smaller than $10\;cm^2$ were classified as small (n=48), those larger than $25\;cm^2$ classified large (n=42) and those in between medium (n=64). Classified according to composition, there were 88 cases (57.1 %) of venous skin flaps, 28 cases of innervated venous flaps, 15 cases of tendocutaneous venous flaps, which incorporated the palmaris longus tendon, for repair of extensor tendons of the fingers, and 17 cases of conduit venous flaps to repair arterial defect. There were 37 cases where multiple injuries to multiple digits were reconstructed. Moreover, there were 6 cases of composite tissue effects that involved soft tissue, blood vessels and tendons. The donor sites were ipsilateral forearm, wrist and thenar area, foot dorsum, and medial calf. The recipient sites were single digit, multiple digits, first web space, dorsum and palm of hand, and wrist. Results: There were seven cases (4.5%) of emergent re-exploration due to vascular crisis, and 3 cases of flap failure characterized by more than 50% necrosis of the flap. The survival rate was 98.1 % (151/154). In small flaps, an average of 1.01 afferent arteries and 1.05 efferent veins were microanastomosed, and in large flaps, an average of 1.88 afferent arteries and 2.19 efferent veins were anastomosed. In 8 cases where innervated flaps were used for reconstructing the palm of the hand, the average static two-point discrimination was $10\;(8{\sim}15)\;mm$. In 12 cases where tenocutaneous flaps were used, active range of motion at the proximal interphalangeal joint was 60 degrees, 20 degrees at the distal interphalangeal joint, and 75 degrees at the metacarpophalangeal joint. Conclusion: We conclude that the arterialized venous flap is a valuable and effective tool in the reconstruction of hand injuries, and could have a more comprehensive set of indications.

  • PDF

소구경 튜브 결함 형태에 따른 유도초음파 신호 해석 특성에 관한 연구 (Study on the Property of Guided Wave Signal Analysis according to Defect Shape of Small Size)

  • 길두송;안연식;정계조;박상기;김용권
    • 비파괴검사학회지
    • /
    • 제32권4호
    • /
    • pp.410-417
    • /
    • 2012
  • 국내의 화력발전소와 원자력발전소는 품질이 좋은 전기를 생산하기 위하여 여러 가지 형태의 복수기 튜브와 증기발생기 튜브들로 구성되어 있다. 이러한 설비에 결함이 발생되었을 경우 검사할 수 있는 여러 가지의 검사 방법이 있으며, 그 중에서도 유도초음파를 이용한 방법은 장비의 설치가 간단하며, 검사 속도가 빠르고 고정된 위치에서 한 번의 주사로 먼 거리를 검사할 수 있기 때문에 주로 많이 사용되고 있다. 유도초음파를 이용한 검사방법이 이러한 장점을 가지고 있는 반면에 아주 작은 크기의 결함은 검출할 수 없는 단점도 가지고 있으며, 본 연구에서는 소구경 튜브 내에서 발생될 수 있는 여러 가지의 인공결함을 가공하여 결함의 형태 및 크기에 따른 실험과 신호 해석을 통하여 이러한 단점들을 극복하고자 노력 하였으며 신호 처리 기술과 검사용 센서 제작 기술의 발달로 인하여 이러한 문제점들은 조만간에 극복될 수 있을 것으로 기대된다.

실리콘 기판 위에 UHV-ICB 증착법으로 적층 성장된 $Y_2O_3$박막의 BS/channeling 연구 (BS/channeling studies on the heteroepitaxially grown $Y_2O_3$ films on Si substrates by UHV-ICB deposition)

  • 김효배;조만호;황보상우;최성창;최원국;오정아;송종한;황정남
    • 한국진공학회지
    • /
    • 제6권3호
    • /
    • pp.235-241
    • /
    • 1997
  • 실리콘 기판위에 초고진공 Ionized Cluster Beam(UHV-ICB)증착법으로 적층 성장시 킨 $Y_2O_3$ 박막의 결정성 및 구조를 Backscattering Spectroscopy(BS)/channeling을 이용하여 분석하였다. 현재까지 타증착법에 의해 성장된 $Y_2O_3$박막의 channeling 최소수율은 0.8~0.95 로 거의 비정질이거나 다결정이었다. 이에 반해 UHV-ICB법으로 Si(100), Si(111) 기판 위에 적층 성장시킨 $Y_2O_3$ 박막의 channeling 최소수율은 각각 0.28, 0.25로 UHV-ICB법으로 성장 시킨 $Y_2O_3$박막이 타증착법으로 성장시킨 박막보다 상대적으로 우수한 결정성을 지니고 있 었다. 또한 실리콘 기판의 방향에 관계없이 $Y_2O_3$박막의 표면 영역이 계면 영역보다 결정성 이 좋았다. Si(111) 위에 적층 성장한 Y2O3박막은 실리콘 결정과 $0.1^{\circ}$어긋나서 (111)면으로 성장하였고, Si(100) 위에 적층 성장한 $Y_2O_3$박막은 실리콘 결정과 평행하게 double domain 구조를 지닌 (110)면으로 성장하였다. 산소공명 BS/channeling 결과 Si(111) 위에 적층 성장 한 $Y_2O_3$박막의 산소는 결정성을 갖고 있으나 Si(100) 위에 적층 성장한 $Y_2O_3$박막의 산소는 random하게 분포하고 있음을 확인하였다.

  • PDF