• 제목/요약/키워드: point correlation

검색결과 2,298건 처리시간 0.027초

갯벌에서 여름철 일몰 전후 이산화탄소 농도 변동 분석 (Variation Analysis of CO2 Concentrations at Sunset before and after of Summer Season at the Foreshore)

  • 강동환;권병혁;김박사
    • 한국환경과학회지
    • /
    • 제23권3호
    • /
    • pp.399-407
    • /
    • 2014
  • In this study, before and after sunset carbon dioxide concentration and air temperature were observed in two points of atmosphere (lower observation point of the GL + 0.1 m, the upper observation point of GL + 1.0 m) on the foreshore at located in Suncheon Bay and their variations were analyzed. Observation was performed on the foreshore on 2~4 August 2010. Instrument (VAISALA, GMP343) was set two hours before sunset and then observation was made continuously for six hours. In three days, observed carbon dioxide concentration was 375~419 ppm, and the air temperature was in the range of $28.7{\sim}32.5^{\circ}C$. The average concentration of carbon dioxide was 388~399 ppm in the upper observation point and 386~396 ppm in the lower observation point. It was higher in the upper observation point and its fluctuations were similar in two observation points. Correlation coefficients between carbon dioxide concentration and air temperature in the upper observation point were in the range of -0.64~-0.88, and were calculated -0.65 to -0.90 in the lower observation point. For the carbon dioxide concentration, correlation coefficients between the upper part and the lower part were very high as 0.98 in three times. For the air temperature, correlation coefficients between the upper part and the lower part were very high as 0.97 and 0.99. In the same observation time, the slope of the linear regression function as carbon dioxide concentration in the lower observation point for the upper observation point was in the range of 0.97~1.01. Carbon dioxide concentration was slightly higher in the upper observation point. Because carbon dioxide in the lower observation point was closer on the surface of the foreshore and absorbed from atmosphere to the foreshore. In this study, it was showed that the vertical variation of carbon dioxide concentration was insignificant in the several meter scale of atmosphere on the surface of the foreshore.

Cross-Correlation 해석을 통한 공동의 소음 특성 연구 (Study on Noise Characteristic of Open Cavity with Cross-Correlation Analysis)

  • 허대녕;김재욱;이덕주
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.755-758
    • /
    • 2002
  • The physical phenomena of rectangular open cavity are numerically investigated in this paper Two-dimensional cavity problems with laminar boundary layers in upstream are simulated by using the compressible Wavier-Stokes equations. The high-order and high-resolution numerical schemes are used for the evaluation of spatial derivatives and the time integration. Cross-correlation is used to analyze the characteristics of wave propagation along time and spatial. Sudden phase shifting of 90 degrees is appeared near downstream edge, and this is coincident with the phase lag suggested in original Rossiter's equation. The results give a further understanding of the physical phenomenon of noise generation, and the resonance of flow and acoustic in cavity. Moreover, modified Rossiter's equation, which is more accurate and can be applied in various conditions, is suggested. The distance from the point of vortex generation to the point of vortex collapsing acts as effective distance of cavity resonance, and the phase difference between the point of vortex collapsing and the point of acoustic source acts as phase lag. The mechanism of acoustic generation is fully understood in this paper. The mechanism of acoustic generation is fully understood in this paper.

  • PDF

Performance Comparison of Four-Parameter Correlation Equations of the Enthalpy of Vaporization

  • Lee, Kyoung-Youl;Park, Kyoung-Kuhn
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제14권3호
    • /
    • pp.118-123
    • /
    • 2006
  • A few commonly used correlation equations of the enthalpy of vaporization essential to the analysis of refrigeration cycles are reviewed. A new four-parameter correlation equation is proposed assuming that the enthalpy of vaporization could be represented with a linear form of the temperature and an additional function which slowly decreases as the temperature increases. It is not a common practice to measure the enthalpy of vaporization by experiment; therefore, performance of the new correlation is examined using numeric data from the ASHRAE tables for 22 pure substance refrigerants. The new correlation equation and other existing ones are fitted to the data optimizing the root mean squared deviation. All data points are weighted equally and NBP (normal boiling point) is used as a fixed point since the NBP is important for refrigeration application. The new four-parameter equation yields an average absolute deviation of 0.05% for 22 refrigerants which is smaller than those of other four-parameter equations, such as Guermouche-Vergnaud (0.08%), Aerebrot (0.13%), Radoz-Lyderson (0.08%), and Somayajulu four-parameter equation (0.08%).

On the Study of Perfect Coverage for Recommender System

  • Lee, Hee-Choon;Lee, Seok-Jun
    • Journal of the Korean Data and Information Science Society
    • /
    • 제17권4호
    • /
    • pp.1151-1160
    • /
    • 2006
  • The similarity weight, the pearson's correlation coefficient, which is used in the recommender system has a weak point that it cannot predict all of the prediction value. The similarity weight, the vector similarity, has a weak point of the high MAE although the prediction coverage using the vector similarity is higher than that using the pearson's correlation coefficient. The purpose of this study is to suggest how to raise the prediction coverage. Also, the MAE using the suggested method in this study was compared both with the MAE using the pearson's correlation coefficient and with the MAE using the vector similarity, so was the prediction coverage. As a result, it was found that the low of the MAE in the case of using the suggested method was higher than that using the pearson's correlation coefficient. However, it was also shown that it was lower than that using the vector similarity. In terms of the prediction coverage, when the suggested method was compared with two similarity weights as I mentioned above, it was found that its prediction coverage was higher than that pearson's correlation coefficient as well as vector similarity.

  • PDF

음향방출 및 상관법을 이용한 상수도배관 누수탐지 연구 (Leak Detection of Waterworks Pipeline Using Acoustic Emission and Correlation Method)

  • 윤동진;정중채;이영섭
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.84-89
    • /
    • 2003
  • Water leak is one of topics with great concern in Korea and many other countries, because of decreasing water supplies and the deterioration of old pipeworks. Correlation techniques have been widely used in leak detection of water pipes, which allow to locate a leak point based on the correlation of leak noise at two sites along water pipes. In this study, both the cross-correlation method and the conventional arrival time difference method are applied in order to analyze and to locate a leak point of a water pipe. In experiment, a 150 m of whole length waterwork pipeline system was constructed in a ground, and several types of leak noise were installed on the pipeline in order to control leak condition. Both the cross-correlation technique and the arrival time difference method showed favorable results at leak detection with the experimental pipeline system.

  • PDF

이미지 상관법을 이용한 3 점 굽힘 시험 계측 프로그램 개발 관한 연구 (Study on the Development of the Digital Image Correlation Measurements Program for Measuring the 3-Point Bending Test)

  • 최인영;강영준;홍경민;고광수;김성종
    • 한국정밀공학회지
    • /
    • 제31권10호
    • /
    • pp.889-895
    • /
    • 2014
  • Machine parts and structures of a change in the displacement and strain can be evaluated safety is one of the important factors. Typically the strain gauge has been employed to measure the displacement and strain. However, this contact-type measurement method has disadvantages that are not measured under condition of specific object shape, surface roughness and temperature. In particularly, 3 point bending and 4 point bending test not use strain gauge. So its test used cross head displacement and deflect meter. Digital Image Correlation measurement methods have many advantages. It is non contact-type measurement method to measure the object displacements and strain. In addition, it is possible to measure the Map of full field displacements and strain. In this paper, measured the 3 point bending deflection using the Digital Image Correlation methods. In order to secure the reliability, Digital Image Correlation method and universal test machine were compared.

강원도 지역여자고등학생들의 식생활 행동과 체중조절 태도에 관한 연구 (A Study on the Eating Behavior and the Attitude about Weight ’s Control of the High School Girls in Kangwondo)

  • 김경희;임양순
    • 한국가정과교육학회지
    • /
    • 제7권1호
    • /
    • pp.29-45
    • /
    • 1995
  • The purpose of this study was to investigate eating behavior and the attitude about weight control of the High School Girls. The questionnaires were completed by 519 girls’ high school students.(lived in city ; 269, in mine region ; 250) The results were as follows: 1. The average stature of them was 159.01${\pm}$5.09cm, the average weight was 51.64${\pm}$6.76kg. 2. In the present body structure of them, the underweight structure was 26.2% the normal weight structure was 58.4% the overweight structure was 15.4%. The present body structure was very different from the recognition of their own body structure. 3. The average point of the eating behavior was 52.07 and that of city(53.62 point) was higher than mine region(50.01 point). 4. The rate of going without breakfast(P<0.05) the frequency of snack(p<0.001) the eating rate of stimulus foods(p<0.05) the interest healthy food life(p<0.05) in two regions showed the significant difference. 5. The point of eating behavior in two regions showed the positive correlation in the economic level, the contentment degree of the present body structure, the conscious healthy condition. But it showed the negative correlation in the rate of going without of breakfast. On observing the difference of the tow regions, it showed the positive correlation to mother’s education career on the negative relation to the experience of the weight control in the city. In the other hand it showed the negative correlation to the recognition on degree of the present body structure in the mine region. 6. The contentment degree of the present body structure showed the negative correlation to the experience of the weight control. Also it showed the negative correlation to the rate of going without breakfast in the city.

  • PDF

Fast landmark matching algorithm using moving guide-line image

  • Seo Seok-Bae;Kang Chi-Ho;Ahn Sang-Il;Choi Hae-Jin
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2004년도 Proceedings of ISRS 2004
    • /
    • pp.208-211
    • /
    • 2004
  • Landmark matching is one of an important algorithm for navigation of satellite images. This paper proposes a fast landmark matching algorithm using a MGLI (Moving Guide-Line Image). For searching the matched point between the landmark chip and a part of image, correlation matrix is used generally, but the full-sized correlation matrix has a drawback requiring plenty of time for matching point calculation. MGLI includes thick lines for fast calculation of correlation matrix. In the MGLI, width of the thick lines should be determined by satellite position changes and navigation error range. For the fast landmark matching, the MGLI provides guided line for a landmark chip we want to match, so that the proposed method should reduce candidate areas for correlation matrix calculation. This paper will show how much time is reduced in the proposed fast landmark matching algorithm compared to general ones.

  • PDF

차량 서브프레임의 유한요소 모델의 개선 및 최적화에 대한 연구 (A Study on the F.E. Model Updating and Optimization for Vehicle Subframe)

  • 허덕재;이근수;홍석윤;박태원
    • 한국자동차공학회논문집
    • /
    • 제10권2호
    • /
    • pp.220-227
    • /
    • 2002
  • This paper describes an integrated approach process to carry out pre-test, model correlation and updating analysis on the sub-frame of a vehicle. In this study, it was found that the modal test could be more efficient when the exciting point was selected on the area with high driving point residue. Such area could be located with the aid of finite element modal analysis. The model correlation was appraised in conjunction with the modal parameters between modal test and finite elements analysis. Also, the finite element model updating was obtained the good resultant using the iteration method based on sensitivity analysis results that carried out the variation of natural frequencies and MAC for the material properties. Finally, optimization of vehicle subframe was carried out the analysis of core location and physical properties by tow steps.

도심지 발파공사장의 발파진동 특성 (The Characteristics of Blasting Vibration in the Construction of Apartment and Buildings in Urban Area)

  • 이연수;장서일
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.521-526
    • /
    • 2004
  • In order to evaluate the effect of blasting vibration in buildings and it's resident located around blasting construction field in urban area, blasting vibration characteristics were measured the vibration level, vibration velocity. The 250g and 750g of charged powder were used at the apartment and at the ground, respectively. In the measurement of the ground, Z(perpendicularity) axis was the highest value in vibration level, but vertical axis was the highest value at 25m point and longitudinal axis was the highest value at 50m point in vibration velocity. The amount of measurement was high value when measuring point is higher than blasting source, while that of measurement was low value when measuring point is lower than blasting source. In the measurement of the apartment, 2 axis was the highest value in vibration level, but in vibration velocity transverse axis was the highest value at ground, was vertical axis at 1st floor, was longitudinal axis at 3rd floor and was vertical and longitudinal axis at 5th floor. The vibration level and the vibration velocity of 50m point showed higher correlation value than 25m point at the ground, but those of 25m point showed higher correlation value than 50m point at the apartment.

  • PDF