• Title/Summary/Keyword: point contacts

Search Result 104, Processing Time 0.027 seconds

Schottky barrier overlapping in short channel SB-MOSFETs (Short Channel SB-FETs의 Schottky 장벽 Overlapping)

  • Choi, Chang-Yong;Cho, Won-Ju;Chung, Hong-Bay;Koo, Sang-Mo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.133-133
    • /
    • 2008
  • Recently, as the down-scailing of field-effect transistor devices continues, Schottky-barrier field-effect transistors (SB-FETs) have attracted much attention as an alternative to conventional MOSFETs. SB-FETs have advantages over conventional devices, such as low parasitic source/drain resistance due to their metallic characteristics, low temperature processing for source/drain formation and physical scalability to the sub-10nm regime. The good scalability of SB-FETs is due to their metallic characteristics of source/drain, which leads to the low resistance and the atomically abrupt junctions at metal (silicide)-silicon interface. Nevertheless, some reports show that SB-FETs suffer from short channel effect (SCE) that would cause severe problems in the sub 20nm regime.[Ouyang et al. IEEE Trans. Electron Devices 53, 8, 1732 (2007)] Because source/drain barriers induce a depletion region, it is possible that the barriers are overlapped in short channel SB-FETs. In order to analyze the SCE of SB-FETs, we carried out systematic studies on the Schottky barrier overlapping in short channel SB-FETs using a SILVACO ATLAS numerical simulator. We have investigated the variation of surface channel band profiles depending on the doping, barrier height and the effective channel length using 2D simulation. Because the source/drain depletion regions start to be overlapped each other in the condition of the $L_{ch}$~80nm with $N_D{\sim}1\times10^{18}cm^{-3}$ and $\phi_{Bn}$ $\approx$ 0.6eV, the band profile varies as the decrease of effective channel length $L_{ch}$. With the $L_{ch}$~80nm as a starting point, the built-in potential of source/drain schottky contacts gradually decreases as the decrease of $L_{ch}$, then the conduction and valence band edges are consequently flattened at $L_{ch}$~5nm. These results may allow us to understand the performance related interdependent parameters in nanoscale SB-FETs such as channel length, the barrier height and channel doping.

  • PDF

Persuasion Tactics of Salesmen : Moderating Effect in Regards to the Purchasing Patterns and Gender of College Students (판매원의 설득전술 : 대학생의 구매형태 및 성별의 조절효과)

  • Yoon, Sung-Wook;Kang, Jiho;Jeong, Weon-Deog
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.11
    • /
    • pp.7494-7500
    • /
    • 2015
  • The purpose of this study is to investigate how the customer's attitudes and behavioral responses, depending on the persuasion tactics of salespeople in customer service and meeting point. The tactics of persuasion of customer acceptance and purchase depending on the type of salesperson with proven effectiveness of even comes out to investigate what results according to the purchase form and the customer that the customer consumes gender. Results First, the tactics of persuasion tactics of coercive tactics to mention the loss of a salesman showed that increasing the degree of acceptance than non-coercive tactics to help consumers buy the information provided above. Second, coercive tactics to adjust the effect with respect to the degree of acceptance of the purchase of helping consumers to purchase in the online form has been proven to be more effective than non-coercive tactics case. Third, adjusted for gender effects were proven to help women with respect to the degree of acceptance of a consumer purchases more effective than men. That is, in consumer contacts, the persuasion tactics of salespeople depending on the customer's acceptance and purchasing intention showed that coercive tactics has the more positive impact on online forms and women.

Fabrication and Characteristics of Infrared Photodiode Using Insb Wafer with p-i-n Structure (p-i-n 구조의 InSb 웨이퍼를 이용한 적외선 광다이오드의 제조 및 그 특성)

  • Cho, Jun-Young;Kim, Jong-Seok;Son, Seung-Hyun;Lee, Jong-Hyun;Choi, Sie-Young
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.3
    • /
    • pp.239-246
    • /
    • 1999
  • A highly sensitive photovoltaic infrared photodiode was fabricated for detecting infrared light in $3{\sim}5\;{\mu}m$ wavelength range on InSb wafer with p-i-n structure grown by MOCVD. Silicon dioxide($SiO_2$) insulating films for the junction interface and surface of photodiode were prepared using RPCVD because InSb has low melting point and evaporation temperature. After formation of In ohmic contacts by thermal evaporation, the electrical properties of the photodiode were characterized in dark state at 77K. A product of zero-bias resistance and area($R_0A$) showed $1.56{\times}10^6\;{\Omega}{\cdot}cm^2$ that satisfied BLIP(background limited infrared photodetector) condition. When the photodiode was tested under infrared light, the normalized detectivity of about $10^{11}\;cm{\cdot}Hz^{1/2}{\cdot}W^{-1}$ was obtained. we successfully fabricated a unit cell with InSb IR array with good quantum efficiency and high detectivity.

  • PDF

THE MORPHOLOGICAL OBSERVATION OF HUMAN GINGIVAL FIBROBLASTS ATTACHMENT AND SPREADING ON THE MECHANICAL TREATED TITANIUM PLASMA SPRAYED IMPLANT SURFACE (기계적 표면 처리된 TITANIUM PLASMA SPRAYED IMPLANT에 대한 치은섬유아세포전개양상의 형태학적 관찰)

  • Whang, Yun-Hi;Lee, Jae-Mok;Suh, Jo-Young
    • Journal of Periodontal and Implant Science
    • /
    • v.25 no.3
    • /
    • pp.741-755
    • /
    • 1995
  • Currently titanium is the material of choice for implants because of its biological acceptance. This high degree of biocompatibility is thought to result, in part, from the protective and stable oxide layer that presumably aids in the bonding of the extracellular matrix at the implant-tissue interface. Endosseous dental implants are interfaced with bone, connective tissue, and epithelium when implanted into the jaw bone. The soft tissue interface including connective tissue and epithelium is one of the most critical factors in the determination of implant maintenance and prognosis. For maintenance of failing or failed implants, it is essential to treat the implant fixture surface to remove bacterial endotoxins and make a surface tolerated by surrounding soft and hard tissues. In this study, the effect of mechanical treatment on titanium plasma sprayed implant on adhesiveness and proliferation of human gingival fibroblasts and changed surface characteristics were studied. titanium plasma sprayed discs manufactured by Friedrichsfeld company were treated with loaw speed stone bur, a rubber point and a jetpolisher. Its surface components were analyzed with Energy dispersive X-ray spectroscopy to evaluate whether the surface characteristics were altered or not. To observe the spreading pattern of the human gingival fibroblasts which attached to the all specimens author used the scanning electron microscope. The results were as follows : Pure titanium and plasma sprayed titanium, stone polished titanium showed titanium peak and small amout of aluminum, so there was no alteration on surface characteristics. Under the scanning electron microscopic examination in the initial attachment of human gingival fibroblast, there was a slight enhancement in pure titanium, stone polished titanium than plasma sprayed titanium. After 6 hours, the pure titanium and stone polished titanium showed human gingival fibroblasts were elongated and connected with numerous processes. Human gingival fibroblasts were more intimately attached on the pure titanium discs than on the other discs. The human gingival fibroblasts attached on the plasma sprayed titanium by thin and elongated processes. After 24 hours, the human gingival fibroblasts connected with each other via numerous processes and compeletly covered the pure titanium and stone polshed titanium discs. Human gingival fibroblasts had multiple point contacts with more long and thin lamellopodia and showed a little bare surface on plasma sprayed titanium discs.

  • PDF

Electron Microscopic Studies on Olfactory Bulbs in the Vertebrates by Phylogenetics (계통발생에 따른 척추동물의 뇌후구에 대한 전자현미경적 연구)

  • Choi, W.B.;Chung, Y.H.;Seo, J.E.
    • Applied Microscopy
    • /
    • v.15 no.2
    • /
    • pp.31-68
    • /
    • 1985
  • Authors are trying to unveil the ultrastructural organization of olfactory bulb, which has been summerized under light microscopic level or communicated only in some detail in different view point until now. For the critical point of view, since the phylogenetical approach will give the ultimate value in the correlative study between structural and functional bases (Brodal, 1969), the present study was carried out light and electron microscopic analyses of the structures of the neurons and synaptic organizations in olfactory bulbs from different animals in phylogenetical scale. We selected each one species from five animal classes: the house rabbit(Oryctolagus cuniculus var. domesticus [Gmelin]) from Mammalia, the domestic fowl (Gallus gallus domesticus Brisson) from Aves, the viper (Agkistrodon hylys [G.P. Pallas]) from Reptilia, a frog (Bombiana orientalis Boulenger) from Amphibia and the crussian carp (Carassius carassius [Linne]) from Pisces. For light microscopic study, samples were fixed in 10% formalin and paraffin sections were stained with hematoxylin-eosin. For the electron microscopic study, the tissues were fixed by perfusion through the heart or immersion with 1% paraform-aldehyde-glutaraldehyde mixture (phosphate buffer, pH 7.4), and final tissue block trimmed under dissecting microscope were osmicated (1% OsO4), they were embedded in Araldite or Epon 812, and ultrathin sections were made by LKB-V ultratome following the inspection of semi-thin sections stained with toluidine blue-borax solution. Ultra-thin sections contrasted with uranyl acetate and lead citrate were observed with JEM 100CX electron microscope. We have summerized our morphological analyses as follows: 1. The olfactory bulb of rabbit, viper and frog shows the eight layers of fila olfactoria, glomerular, external granular, external plexiform, mitral cell, internal plexiform, internal granular, medullary but domestic fowl shows the five layers of glomerular, fibrillar, mitral, granular and medullary and the three layers of fibrilla, glomerular and medullary in crussian carp. The sharpness of demarcation between the layers shows deferential tendency according to phylogenetical order. 2. Mitral cells of vertebrate have large triangular or oval shape with spherical nuclei which contain not so much chromatin. The cytoplasm contains numerous cell organelles, of which Nissl's bodies or granular endoplasmic reticula arranged as parallel strands. Development of granular endoplasmic reticula were declined as the phylogentical grade is going lower. 3. Tufted cells of all animal are mostly spindle or polygonal contour and contain oval nuclei which located in periphery of cytoplasm. The nuclei of rabbit, fowl, viper and frog has relatively space chromatin, but a nucleus of crussian carp contain irregularly aggregated chromatin in karyoplasm. Their cytoplasmic volume and cell organelle contents are in between those of mitral cell and granular cell. They contain moderate amount of mitochondria, granular endoplasmic reticula, a few Golgi complex, polysomes, lysosome, etc. 4. Granule of cells of all the vertebrate amimals studied exhibit similar features; cells and their dense nuclei show spherical or oval contour, and they have the thin rim of cytoplasm which contain only a few cell organelles. 5. In rabbit, the soma of mitral cells were in contact with boutons with two types of synaptic vesicles, that is, round and flat vesicles, especially flat vesicles in boutons were showing reciprocal synapses. However, in domestic fowls, vipers, frogs and crussian carps, there were found boutons showing only spherical synaptic vesicles. 6. The boutons containing round synaptic vesicles were made contact with the some of tufted cell of olfactory bulb in the rabbits, fowls, vipers and frogs, but no synaptic boutons were observed in soma of tufted cells in crussian carps. In the frogs, there were observed dendrites were contact with the soma of tufted cells. 7. In the neuropils of plexiform, granular and glomerular layers olfactory bulbs in the vertebrate, the synapses were axo-large dendrites, axo-median and small dendrites, dendrodendritic, and axo-axonal contacts. However, in the neuropil of crussian carps, synapses were observed only in glomerular layer.

  • PDF

Analysis of Occlusal Contacts Using Add-picture Method (Add-picture 방법을 이용한 교합접촉점 분석)

  • Park, Ko-Woon;Cho, Lee-Ra;Kim, Dae-Gon;Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.1
    • /
    • pp.45-58
    • /
    • 2013
  • The purpose of this study was to analyze the area of occlusal contact points using visual method. One subject was selected who had Angle Class I, normal dentition, without dental caries, periodontal disease and temporomandibular disorders. Forty times PVS impressions were taken and 10 pairs casts were fabricated using dental super hard stone. After mounting the casts with customized loading apparatus, 78.9kg/f force was loaded as a maximum biting force. In T-Scan method, occlusal contact points measurement was repeated twice. Then, using Photoshop program (Adobe photoshop CS3, Adobe. San Jose, USA), the pixels which indicated occlusal contact points by color was recognized, and the distribution of recognized pixels were calculated to area. In Add picture method, polyether bite material applied to the occlusal surface of the casts. Then, the image of the translucent areas was recorded and classified $0{\sim}10{\mu}m$, $0{\sim}30{\mu}m$, $0{\sim}60{\mu}m$ area by the amount of transmitted light. To acquire occlusal surface, the numbers of pixels from the photograph of the contact area indicated cast converted to $mm^2$. The mean occlusal contact area by two methods was statistically analyzed (paired t-test). Part of the red and pink area in T-Scan image were almost equivalent to the $0{\sim}10{\mu}m$, $0{\sim}30{\mu}m$, $0{\sim}60{\mu}m$ area in Add picture image. The distribution of occlusal contact points were similar, but the average area of occlusal contact points was wider in T-scan image (P<.05). Pink and red area in T-scan image was wider than $0{\sim}10{\mu}m$, $0{\sim}30{\mu}m$ area in Add picture image (P<.05), but similar to $0{\sim}60{\mu}m$area in Add picture image (P>.05). Occlusal contact points in T-scan image did not indicate real occlusal contact points. Occlusal contact areas in T-scan method were enlarged results comparing with those in Add picture method.

A Study on the Historical Origin of Private Security Industry in Korea (우리나라 보안산업의 역사적 기원에 관한 연구)

  • Lee, Chang-Moo
    • Korean Security Journal
    • /
    • no.22
    • /
    • pp.91-111
    • /
    • 2010
  • Around the middle of the ninth century the strict bone-rank system of Silla frustrated many people who had political ambition but lacked nobility. They had to seek other ways, including maritime trade. Such an undertaking reflected and also increased their economic and military power. Trade prospered with T'ang China and with Japan as well. The threat of piracy to Silla's thriving maritime trade caused to create a succession of garrisons at important coastal points. Chonghae Jin (Chonghae garrison) was regarded as the most important of these. It was established in 828 by Chang Pogo. Chonghae Jin was on Wando, an island just east of the southwestern tip of Korea and a key place at this time in the trade between China, Korea, and Japan. From this vantage point Chang Pogo became a merchant-prince with extensive holdings and commercial interests in China and with trade contacts with Japan. Although piracy was rampant in East Asia at that time, either the Chinese or Silla government was not able to control it due to inner political strife and lack of policing resources. Infuriated by the piracy and the government's inability to control it, Chang Pogo came back to Silla to fight against the pirates and to protect maritime trade. He persuaded the king of Silla and was permitted to control the private armed forces to sweep away the pirates. In 829 he was appointed Commissioner of Chonghae-Jin with the mission of curbing piracy in that region. Chang's forces were created to protect people from pirates, but also developed into traders among Silla Korea, T'ang China, and Japan in the 9th century. This was geographically possible because the Chonghae Garrison was situated at the midpoint of Korea, China, and Japan, and also because Chang's naval forces actually dominated the East Asia Sea while patrolling sea-lanes. Based on these advantages, Chang Pogo made a great fortune, which might be collected from a charge for protecting people from pirates and the trades with China and Japan. Chang's forces could be termed the first private security company in the Korean history, at least in terms of historical documents. Based on historical documents, the numbers of private soldiers might be estimated to exceed tens of thousands at least, since Chang's forces alone were recorded to be more than ten thousand. Because local powers and aristocratic elites were said to have thousands of armed forces respectively, the extent of private forces was assumed to be vast, although they were available only to the privileged class. In short, the domination of Chang's forces was attributable to the decline of central government and its losing control over local powers. In addition it was not possible without advanced technologies in shipbuilding and navigation.

  • PDF

Predictive Factors of Health promotion behaviors of Industrial Shift Workers (산업장 교대근무 근로자의 건강증진행위 예측요인)

  • Kim, Young-Mi
    • Korean Journal of Occupational Health Nursing
    • /
    • v.11 no.1
    • /
    • pp.13-30
    • /
    • 2002
  • Industrial shift workers feels suffer mental stresses which are caused by unfamiliar day sleep, noisy environment, sleeping disorder by bright light, unusual contacts with family, difficulty in meeting with friends or having formal social meetings and other social limitations such as the use of transportation. Such stresses influence health of the workers negatively. Thus the health promotion policy for shift workers should be made considering the workers' ways of living and shift work specially. This study attempted to provide basic information for development of the health promotion program for industrial shift workers by examining predictive factors influencing health promotion behaviors of those workers. In designing the study, three power generation plants located in Pusan and south Kyungsang province were randomly selected and therefrom 280 workers at central control, boiler and turbine rooms and environmental chemistry parts whose processes require shift works were sampled as subjects of the study. Data were collected two times from September 17 to October 8, 1999 using questionnaires with helps of safety and health managers of the plants. The questionnaires were distributed through mails or direct visits. Means for the study included the measurement tool of health promotion behavior provided by Park(1995), the tool of self-efficacy measurement by Suh(1995), the tool of internal locus of control measurement by Oh(1987), the measurement tool of perceived health state by Park(1995) and the tool of social support measurement by Paek(1995). The collected data were analyzed using SPSS program. Controlling factors of the subjects were evaluated in terms of frequency and percentage ratio Perceived factors and health promotion behaviors of the subjects were done so in terms of mean and standard deviation, and average mark and standard deviation, respectively. Relations between controlling and perceived factors were analyzed using t-test and ANOVA and those between perceived factors and the performance of health promotion behaviors, using Pearson's Correlation Coefficient. The performance of health promotion behaviors was tested using t-test, ANOVA and post multi-comparison (Scheffe test). Predictive factors of health promotion behavior were examined through the Stepwise Multiple Regression Analysis. Results of the study are summarized as follows. 1. The performance of health promotion behaviors by the subjects was evaluated as having the value of mean, $161.27{\pm}26.73$ points(min.:60, max.:240) and average mark, $2.68{\pm}0.44$ points(min.:1, max.:4). When the performance was analyzed according to related aspects, it showed the highest level in harmonious relation with average mark, $3.15{\pm}.56$ points, followed by hygienic life($3.03{\pm}.55$), self-realization ($2.84{\pm}.55$), emotional support($2.73{\pm}.61$), regular meals($2.71{\pm}.76$), self-control($2.62{\pm}.63$), health diet($2.62{\pm}.56$), rest and sleep($2.60{\pm}.59$), exercise and activity($2.53{\pm}.57$), diet control($2.52{\pm}.56$) and special health management($2.06{\pm}.65$). 2. In relations between perceived factors of the subjects(self-efficacy, internal locus of control, perceived health state) and the performance of health promotion behaviors, the performance was found having significantly pure relations with self-efficacy (r=.524, P=.000), internal locus of control (r=.225, P=.000) and perceived health state(r=.244, P=.000). The higher each evaluated point of the three factors was, the higher the performance was in level. 3. When relations between the controlling factors(demography-based social, health-related, job-related and human relations characteristics) and the performance of health promotion behaviors were analyzed, the performance showed significant differences according to marital status (t=2.09, P= .03), religion(F=3.93, P= .00) and participation in religious activities (F=8.10, P= .00) out of demography-based characteristics, medical examination results (F=7.20, P= .00) and methods of the collection of health knowledge and information(F=3.41, P= .01) and methods of desired health education(F=3.41, P= .01) out of health-related characteristics, detrimental factors perception(F=4.49, P= .01) and job satisfaction(F=8.41, P= .00) out of job-related characteristics and social support(F=14.69, P= .00) out of human relations characteristics. 4. The factor which is a variable predicting best the performance of health promotion behaviors by the subjects was the self-efficacy accounting for 27.4% of the prediction, followed by participation in religious activities, social support, job satisfaction, received health state and internal locus of control in order all of which totally account for 41.0%. In conclusion, the predictive factor which most influence the performance of health promotion behaviors by shift workers was self-efficacy. To promote the sense, therefore, it is necessary to develop the nursing intervention program considering predictive factors as variables identified in this study. Further industrial nurses should play their roles actively to help shift workers increase their capability of self-management of health.

  • PDF

SURFACE CHANCE OF EXTERNAL HEXAGON OF IMPLANT FIXTURE AND INTERNAL HEXAGON OF ABUTMENT AFTER REPEATED DELIVERY AND REMOVAL OF ABUTMENT (지대주의 반복적인 착탈에 따른 임플랜트 고정체의 external hexagon과 지대주 internal hexagon의 변화에 관한 연구)

  • Jung Seok-Won;Kim Hee-Jung;Chung Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.4
    • /
    • pp.528-543
    • /
    • 2005
  • Statement of problem: Repeated delivery and removal of abutment cause some changes such as wear, scratch or defect of hexagonal structure. It may increase the value of rotational freedom(RF) between hexagonal structures. Purpose: The purpose of this study was to evaluate surface changes and rotational freedom between the external hexagon of the implant fixture and internal hexagon of abutment after repeated delivery and removal under SEM and toolmaker's microscope. Materials and methods: Implant systems used for this study were 3i and Avana. Seven pail's of implant fixture, abutment and abutment screws for each system were selected and all fixtures were perpendicularly mounted in liquid unsaturated polyesther with dental surveyor. Each one was embedded beneath the platform of fixture. Surfaces of hexagonal structure before repeated closing and opening of abutment were observed using SEM and rotational freedom was measured by using toolmaker's microscope. Each abutment was secured to the implant future by each abutment screw with recommended torque value using a digital torque controller and was repeatedly delivered and removed by 20 times respectively. After experiment, evaluation for the change of hexagonal structures and measurement of rotational freedom were performed. Result : The results were as follows; 1. Wear of contact area between implant fixture and abutment was considerable in both 3i and Avana system. Scratches and defects were frequently observed at the line-angle of hexagonal structures of implant fixture and abutment. 2. In the SEM view of the external hexagon of implant fixture, the point-angle areas at the corner edge of hexagon were severely worn out in both systems. It was more notable in the case of 3i systems than in that of Avana systems. 3. In the SEM view of the internal hexagon of abutment, Gingi-Hue abutment of 3i systems showed severe wear in micro-stop contacts that were machined into the corners to prevent rotation and cemented abutment of Avana systems showed wear in both surface area adjacent to the corner mating with external hexagon of implant fixture. 4 The mean values of rotational freedom between the external hexagon of the implant fixture and internal hexagon of abutment were 0.48$\pm$0.04$^{\circ}$ in pre-tested 3i systems and 1.18$\pm$0.25$^{\circ}$ after test, and 1.80$\pm$0.04$^{\circ}$ in pre-tested Avana systems and 2.61$\pm$0.16$^{\circ}$ after test. 5. Changes of rotational freedom after test shouted statistical)y a significant increase in both 3i and Avana systems(P<0.05, paired t-test). 6. Statistically, there was no significant difference between amount of increase in the rotational freedom of 3i systems and amount of increase in that of Avana ones(P>0.05, unpaired t-test). Conclusion: Conclusively, it was considered that repeated delivery and remove of abutment by 20 times would not have influence on screw joint stability. However, it caused statistically the significant change of rotational freedom in tested systems. Therefore, it is suggested that repeated delivery and remove of abutment should be minimal as possible as it could be and be done carefully Additionally, it is suggested that the means or treatment to prevent the wear of mating components should be devised.

A QUALITATIVE AND QUANTITATIVE STUDY ON OCCLUSAL CONDITIONS IN HEALTH VOLUNTEERS AND ATHLETES WITH NORMAL OCCLUSION (정상인과 체육인의 교합상태에 대한 정상적.정량적 비교 연구)

  • Jang, Jung-Mi;Lee, Sung-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.2
    • /
    • pp.302-322
    • /
    • 1998
  • This study was accompolished to analyze and compare the number and area of the occlusal contact points in healthy volunteers and athletes with normal occlusion. For this study, 15 athletes(13 amles and 2 females with average age 20) and 21 healthy volunteers(14 mles and 7 females with average age 20.09) were selected. The visual display acquired by scanning of occlusal record in maximal intercuspation was converted into 16 gray value image. Then, using computer program(J & Lee Occlusal Analyser), the pixel which was in definite range of the gray value was recognized, and the numbers of recognized pixel were calculated to area. The results were as follows ; 1. The average numbers of total occlusal contact feints were 31.05 in control group, and 34.67 in athlete group. The average area of total occlusal contacts was $100.25mm^2$ in control group, and $127.78mm^2$ in athlete group. 2. In control group, the average numbers of occlusal contact points were revealed in order as follows ; the first molar(8.48), the second molar(8.24), the second premolar(4.71), the lateral incisor(2.90), the first premor(2.43), the central incisor(2.19), and the canine(2.1). The least average in canine(2.1) was similar to the average(2.19) in central incisor and (2.09) in lateral incisor. In athlete group, the average numbers of occlusal contact points were revealed in order as follows ; the first molar(8.97), the second molar(8.47), the second premolar(5.60), the canine(3.80), the lateral incisor(3.33), the first premolar(2.67), and the central incisor(1.93). 3. In control group, the average areas of occlusal contact surface were revealed in order as follows ; the first molar($39.47mm^3$), the second molar($37.54mm^3$), the second premolar($9.54mm^3$) the first premolar($6.18mm^3$), canine($3.49mm^3$), the central incisor($2.76mm^3$), and the lateral incisor($1.28mm^3$). In athlete group, the average areas of occlusal contact surface were revealed in order as follows ; the first molar($44.11mm^3$), the second molar($40.69mm^3$), the second premolar($16.50mm^3$), the first premolar($9.39mm^3$), the canine($5.08mm^3$), the lateral incisor($3.7mm^3$), and the central incisor($2.25mm^3$). 4. With aging in both control and athlete group, there was a decreasing tendancy in average number of occlusal contact point, and was an increasing tendancy in average area of occlusal contact surface. In comparison at each age, both the numbers and area of occlusal contact were greater in athlete group than in control group. It was not significant in the numbers of occlusal contact points beween athlete and control group(p>0.1), but significant in the area of occlusal contact surface(p<0.03). 5. In comparision as to the kind of sports(Gymnastics : 2, Rugby : 3, Soccor : 5, Ice hocky : 5), the numbers of occlusal contact points were the most in ice hocky, and the area of occlusal contact surface was the greatest in gymnastics. With increasing a career in athlete group, there was a decreasing tendancy in average numbers of occlusal contact points and was an increasing tendancy in average area of occlusal contact surface. 6. By T-scan analyzing, the contact numbers on the anterior teeth were greater in control group than in athlete group, and on the posterior teeth were greater in athlete group than in control group. And the results acquired by T-scan were lesser than that caquired by the silicone bite records. It was not significant in the posterior teeth, but significant in the anterior teeth. In T-scan records, the numbers of occlusal contact points on second molar were the greatest, but in the silicone records, the numbers on first molar were the greatest.

  • PDF