• 제목/요약/키워드: pneumatic total artificial heart

검색결과 2건 처리시간 0.019초

송아지에 이식한 공기구동형 인공심장의 혈역학적 연구 (Hemodynamic study of Pneumatic Artificial Heart Implanted in Calves)

  • 박표원
    • Journal of Chest Surgery
    • /
    • 제23권3호
    • /
    • pp.438-451
    • /
    • 1990
  • Pneumatic total artificial heart[TAH] has been clinically applied for the purpose of permanent or temporary use followed by cardiac transplantation in the patients with end stage heart diseases. In spite of the good durability of the pneumatic TAH, thrombus formation, bleeding and infection resulted in death. The Tomasu heart, which is a type of pneumatic TAH, was used in this study. This model is a modified Jarvik heart and consists of atrial cuffs, outflow vascular grafts and thin-layer seamless diaphragm type of ventricles. Cardiac outputs of the left artificial heart were measured by Donovan`s mock circulation under variable conditions of driving parameters, and an experimental artificial heart implantation was performed in 4 calves to observe the changes of hemodynamic parameters in early postoperative period and hematologic and bio-chemical changes in a long-term survival case. In the mock circulation test, cardiac output of the heart was increased with the increase of the left atrial pressure and left driving pressure. Maximum cardiac output was obtained at the heart rate of 120 to 130/min and percent systole of 40 to 45Zo under the condition of a constant left driving pressure of 180mmHg and left atrial pressure of 10mmHg. During the first 24 hours of TAH pumping, driving pressure ranged from 178$\pm$5mmHg to 187$\pm$8mmHg for the left heart and from 58$\pm$6mmHg to 78$\pm$28mmHg for the right heart. The Mean arterial pressure significantly increased between 2 and 8 hours after the start of pumping. The survival time ranged from 27 hours to 46 days. The causes of death were respiratory failure in 2 cases, mechanical valve failure in one, and left ventricular outflow obstruction due to thrombus in a 46-day survival case. This study demonstrated that Tomasu artificial heart operated effectively during the first 24 hours of artificial heart pumping, but thrombus formation around the valve holding area was the main problem in long-term survival case.

  • PDF

송아지를 이용한 한국형 인공심장의 동물실험에 관한 보고 (Experimental Study of the "Korean Artificial Heart" in Calf)

  • 서경필
    • Journal of Chest Surgery
    • /
    • 제22권2호
    • /
    • pp.202-211
    • /
    • 1989
  • We experienced a series of animal experimental studies of the total artificial heart in 1988. So called, "Korean Heart* was used in this study, which is developed and fabricated in the Department of Biomedical Engineering, College of Med., S.N.U.. "Korean Heart" is a Rolling-Cylinder Motor-Driven type which is a newly developed electromechanical heart over the shortcomes of the previous artificial hearts, especially pneumatic type. The advantages of the "Korean Heart" are total implantability, quiet and smooth movement, small size fittable in oriental people, etc. The animal experiments were performed two times, as an assist device in sheep and total artificial heart implant experiment in calf weighing 100 kg. After total implantation, the artificial heart was well functioned in movement and hemodynamic control. So that, the calf was recovered excellently, which was able to stand up by herself and take an oral intake. Total survival time was 100 hours and the cause of death was a sudden pumping failure [electrical connection problem]. Several postoperative laboratory results almost within normal limits and no hemolysis, but in autopsy, the multiple thromboembolic findings were seen at the lung and kidney.n at the lung and kidney.

  • PDF